Technical data
Tool data
CP8849 CP8849-2
Recommended am- 10to 38°C 10 to 38°C
bient charging tem-
perature
ah = impact tightening of fasteners of the maximum capacity
of the tool.
Wear hearing protection.
Recommended bat- CP20XP CP20XP The vibration emission given in this information sheet has
tery types CP20XP60 CP20XP60 been measured in accordance with a standardized test given
Recommended
charger CP20CHE 20V EU CP20CHE 20V EU
CP20CHU 20V US CP20CHU 20V US in EN 60745 and may be used to compare one tool with an-
other. It may be used for a preliminary assessment of expo-
CP20CHA 20V
AUS
CP20CHK 20V
UK
CP20CHKC 20V
KC
Declarations
CP20CHA 20V
AUS
CP20CHK 20V
UK
CP20CHKC 20V
KC
sure.
The declared vibration emission level represents the main ap-
plications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained,
the vibration emission may differ. This may significantly in-
crease the exposure level over the total working period.
An estimation of the level of exposure to vibration should
also take account the times when the tool is switched off or
when it is running but not actually doing the job. This may
significantly reduce the exposure level over the total working
EU DECLARATION OF CONFORMITY
We, CHICAGO PNEUMATIC Tool Co. LLC, 1815 Club-
house Road, Rock Hill, SC 29730, declare under our sole re-
sponsibility that the product (with name, type and serial
number, see front page) is in conformity with the following
Directive(s):
Machinery (2006/42/EC), EMC(2014/30/EU), RoHs
(2011/65/EU)
Harmonized standards applied:
EN 62841-1:2015, EN 62841-2-2:2014, EN 55014-1:2017,
EN 55014-2:2015, EN50581-1:2012
period.
Identify additional safety measures to protect the operator
from the effects of vibration such as : maintain the tool and
the accessories, keep the hands warm, organization of work
patterns.
These declared values were obtained by laboratory type test-
ing in accordance with the stated standards and are suitable
for comparison with the declared values of other tools tested
in accordance with the same standards. These declared val-
ues are not adequate for use in risk assessments and values
measured in individual work places may be higher. The ac-
tual exposure values and risk of harm experienced by an indi-
vidual user are unique and depend upon the way the user
works, the workpiece and the workstation design, as well
upon the exposure time and the physical condition of the
user.
Authorities can request relevant technical information from:
Pascal Roussy, R&D Manager, Ets Georges Renault, 38 rue
Bobby Sands
Saint-Herblain,
Pascal ROUSSY
Signature of issuer
- 100% mode (re- 0 - 1800
Square drive (mm) 13 13 Noise and vibration
Sound pressure level Lp (dB(A)) 101.5
Sound power level Lw (dB(A)) 112.5
Noise uncertainty (dB(A)) 3
Vibration value (m/s²) (ah) 16.1
Vibration uncertainty (K) (m/s²) 1.5
Vibration standard ISO-28927-2