
WS1”, 1.5” & 2” Series NRU
Installation Operation Maintenance Manual
Simplex Clack NRU rev 1 Page 2 of 27
1.0 PARTS LIST
..................................................................................................................................3
1.1 BASIC PARTS LIST.....................................................................................................................3
1.2 MISSING OR DAMAGED GOODS..............................................................................................3
2.0 TEMPORARY STORAGE
..............................................................................................................3
3.0 REGENERATION
..........................................................................................................................3
3.1 The Regeneration Process....................................................................................................3
3.2 METER CONTROL OF REGENERATION.....................................................................................4
3.3 TIME CLOCK CONTROL OF REGENERATION INITIATION..........................................................4
4.0 PRE-INSTALLATION CHECKS
......................................................................................................4
4.1 MECHANICAL...........................................................................................................................4
4.1.1 Foundation/Drainage .......................................................................................................4
4.1.2 Operating Space ...............................................................................................................5
4.1.3 Incoming Water................................................................................................................5
4.1.4 Pipework...........................................................................................................................5
4.1.5 Water Supply Company Requirements ............................................................................5
4.2 ELECTRICAL ..............................................................................................................................6
5.0 ASSEMBLY/INSTALLATION
........................................................................................................6
5.1 MECHANICAL...........................................................................................................................6
5.1.1 Pipework...........................................................................................................................6
5.1.2 Assembly...........................................................................................................................6
6.0 PROGRAMMING
.........................................................................................................................7
6.1 INTRODUCTION .......................................................................................................................7
6.2 CONTROLLER SETTING.............................................................................................................7
6.2.1 Setting the Time of Day ....................................................................................................8
6.3 Factory Programming
............................................................................................................9
7.0 COMMISIONING ....................................................................................................................12
8.0 ROUTINE MONITORING.............................................................................................................13
9.0 FAULT FINDING AND RECTIFICATION ........................................................................................14
9.1 NO FLOW TO SERVICE ...........................................................................................................14
9.2 POOR TREATED WATER QUALITY..........................................................................................14
9.3 NO REGENERATION ...............................................................................................................15
9.4 UNSATISFACTORY CAPACITY BETWEEN REGENERATIONS....................................................15
10.0 WARRANTY AND SERVICE ...................................................................................................15
10.1 AFTER SALE WARRANTY ......................................................................................................15
11.0 Technical Data
........................................................................................................................16
11.1 Process and Operating Data
........................................................................................16
11.1.1 WS1 20-80 L...........................................................................................................16
11.1.2 WS1 100-350 L.......................................................................................................17
11.1.3 WS1.5 100-500 L....................................................................................................18
11.1.4 WS2 150-750 L.......................................................................................................19
11.2 ENGINEERING DATA
.....................................................................................................20
11.2.1 WS1 20-80 L...........................................................................................................20
11.2.2 WS1 100-350 L.......................................................................................................21
11.2.3 WS1.5 100-500 L....................................................................................................22
11.2.4 WS2 150-750 L.......................................................................................................23
12.0 FACTORY PROGRAM................................................................................................................24
13.0 CE Certificate
..........................................................................................................................27