Plura PIPM-R-7-Type C User manual

Re-imagine Beyond Technology sales@plurainc.com
Operating Instructions
PIPM-R-7-Type C
"Plura IP Module" for SFP-H-7 Series
SFP-317-H-7
SFP-321-H-7
SFP-324-H-7
SFP-332-H-7
SFP-347-H-7
SFP-355-H-7
SFP-324-H-7
SFP-Modules
Operating Instructions
SFP-H-7 SERIES with PIPM-R-7-TypeC

Re-imagine Beyond Technology sales@plurainc.com
REVISION HISTORY
VERSION DATE CHANGES
1.00 2022-01-06 1st official release
6
6
7
7
9
10
10
10
12
12
12
14
16
17
19
19
19
21
21
21
22
1. OVERVIEW
2. GENERAL FEATURES
3. PRODUCTION WORKFLOW AND I/O CONNECTIONS
1) PRODUCTION WORKFLOW
2) I/O & CONNECTIVITY
4. INSTALLATION OVERVIEW
1) INITIAL SETUP BY WEB BROWSER
2) CONNECTING TO THE CONTROL LAN USER INTERFACE “UI”
5. WEB CONFIGURATION & INTERFACE
1) OVERVIEW
2) EMBER+ CONTROL UPDATE
3) MONITOR FPGA AND FIRMWARE
4) EMBER+/TSL LICENSE UPDATE
5) WEB UI UPDATE
6. MEDIA LAN 2110 CONTROL (OUT-BAND)
1) OVERVIEW
2) MANAGEMENT VIA CONTROL LAN UI
3) 10G/25G SWITCH CONFIGURATION REQUIREMENTS
4) 2022-7 HITLESS SWITCHING TOGGLE ON - CONFIGURING FLOWS FOR
REDUNDANCY
5) 2022-7 HITLESS SWITCHING TOGGLE OFF - CLEAN SWITCH MODE
6) IMPORTING SDP FILES
7) SPECIFIC CONFIGURING USING REST URLS VIA REST API CLIENT 24
Operating Instructions2
SFP-H-7 SERIES with PIPM-R-7-TypeC
2

Re-imagine Beyond Technology sales@plurainc.com
•PRECAUTION
Before operating this unit, please read this manual carefully.
WARNING:
To reduce the risk of any electric shock, please do not remove the back cover. No user serviceable parts inside. Refer any service matters to
qualified service personnel. To prevent fire or shock hazard, do not expose the rear of the set to rain or moisture. Do not rub, clean or hit the
Active Matrix LCD with object that may scratch, mark, or damage the Active Matrix LCD permanently.
CAUTION:
Unauthorized tampering with the inside of the monitor invalidates the warranty.
The manufacturer shall not warrant for any damage caused by improper maintenance and/or repair or work by third parties.
Important safeguards for you and your new product:
Your product has been manufactured and tested with your safety in mind. However, improper use can result in potential electrical shock or
fire hazards. Please read and observe the following safety points when installing and using your new product and save them for future
reference.
1. Read Instructions
2. Follow Instructions
All operating and use instructions should be followed.
3. Retain Instructions
The safety and operating instructions should be retained for future reference.
4. Notice Warnings
All warnings on the product and in the operating instructions should be adhered to.
5. Cleaning
Disconnect the unit from the mains before cleaning the unit. Do not use abrasive cleaners. Use a damp
cloth ONLY for cleaning.
6. Water and Moisture
Operating Instructions3
SFP-H-7 SERIES with PIPM-R-7-TypeC
3

Re-imagine Beyond Technology sales@plurainc.com
Do not use this product near water surface.
7. Transporting Product
This product should be moved with care. Quick stops, excessive force and uneven surfaces may cause the
product damages.
8. Accessories
Do not use accessories not recommended by PLURA Inc. as they may cause hazards.
9. Ventilation
Do not block any of the ventilation openings.
Install in accordance with the manufacturer’s instructions.
10. Power Sources
This product should be operated only from the type of power source indicated on the marking label. If you
are not sure of the type of power supply, consult your power supply company.
11. Power Lead Polarization
This product is equipped with a three-wire grounding-type cord. This is a safety feature. Do not use any
other type power cord.
12. Power Cord Protection
Power-supply cords should be dressed so that they are not likely to be pulled or pinched by items placed
upon or against them.
13. Lightning
For added protection for this product during a lightning storm, or when it is left unattended and unused
for long periods of time, unplug it from the wall outlet. This will prevent possible damage to the product
due to lightning and power-line surges.
14. Grounding the product
This product must be grounded properly to comply with the safety regulations in the country of use. If you
are unsure of these regulations, please consult a qualified electrician.
15. Servicing
Do not attempt to service this product by yourself as opening or removing covers may expose you to
dangerous voltages or other hazards. Refer all servicing to qualified service personnel.
16. Damage Service Required
Isolate this product from the mains and refer to qualified service personnel under the following conditions:
A. If the power-supply cord or plug is damaged.
B. If the front LCD front has been damaged.
C. If the product does not operate correctly by following the operating instructions. Use only the user
control buttons any improper adjustment of other controls may result in damage and will often require
extensive work by a qualified technician to restore the product to its normal operation.
D. If the product has been dropped.
Operating Instructions4
SFP-H-7 SERIES with PIPM-R-7-TypeC
4

Re-imagine Beyond Technology sales@plurainc.com
E. If the product exhibits a distinct change in performance.
17. Safety Check
Upon completion of any service or repairs to this product, ask the service technician to perform safety
checks to determine that the product is in proper operating condition and the warranty seal is provided.
18. Mounting
The product should be mounted on a wall as recommended in the instructions.
19. Power
This set operates on an AC supply; the voltage is as indicated on the label on the Manual. This appliance
must be earthed at all times through the chassis as well as through the power lead.
Operating Instructions5
SFP-H-7 SERIES with PIPM-R-7-TypeC
5

Re-imagine Beyond Technology sales@plurainc.com
1. OVERVIEW
Plura SFP-H-7 series with Type C Plura IP platform is the industry’s trusted TRUE-IP 10GbE
broadcast & media monitor solution, supporting uncompressed FHD based on SMPTE ST 2110,
ST 2022-6Ŧ & ST 2022-7 and supports up to 1920 x 1080 resolutions.
The flexibility and robustness of the SFP-H-7 platform is the ultimate solution for a wide range
of broadcast and professional media SDI to IP transition projects. The SFP-H-7 platform is a
powerful hybrid solution supporting SFP+ 10G (ST 2110, ST 2022-6Ŧ, ST 2022-7), 3G & 1.5G &
HDM I 1.4 connectivity.
2. GENERAL FEATURES
●Dual 10 GbE SFP+ interfaces as
MEDIALAN1 and MEDIALAN2
●Two generic compatible 10G-SR SFP+
850nm digital optical monitoring
LC MMF optical transceiver modules
included
●Dual 10GbE De-Encapsulation channels
are fully compatible with many MM and
SM SFP modules manufactures
●1 x 3G/1.5G loop output for MEDIALAN1
main ST 2110Ŧ support
●1 x 3G/1.5G Aux/2nd channel ST 2110Ŧ
support
●Supports ST 2110, ST 2022-6Ŧ, ST
2022-7 & PTP/ST 2059 V2
●ST 2110-10, System architecture and
synchronization: essences, RTP, SIP and
PT P
●ST 2110-20, Uncompressed video
transport, Wide / Narrow types
●ST 2110-21, Traffic shaping and network
delivery timing
●ST 2110-30, Audio transport profile level
C, 16CH, 48Khz sample rate, 1ms/.125µs
●ST 2110-40, Transport of ancillary data
●ST 2022-7 seamless protection
switching providing data loss protection
●SMPTE ST 2022-6Ŧ supported with
optional license
●Ember+, NMOS, JT-NM Interoperability
support
●Management Interface support (NMOS
& REST API In-band)
●Web UI / Ember+ Out-band control
support
●NMOS IS-04 discovery and registration
●NMOS IS-05 device connection
management
●JT-NM NMOS certification support
●JSON snippet for NMOS control support
●Ember+ monitor control support with
extensive Ember+ tree control
●Session Description Protocol “SDP” file
support
●IGMP V2 & V3 support
●Plura web user interface “UI” support
●Supports Coaxial 3G/1.5G BNC I/O
connectivity
●Supports Coaxial SFP I/O connectivity
●2xSFP+ cage supporting 10G/3G/1.5G
SDI
●1 x HDMI 1.4 input port
●Supports up to 1920 x 1080 resolutions
●RGB 12 bit Digital Signal Processing
●178 degree Viewing Angle Display
●Gamma Selectable ( 0.8 – 3.0)
●Color Temperature – User, VAR,
Adjustable (11000K TO 3200K)
●(ICAC) – Plura Intelligent Connection for
Alignment & Calibration
●Display Advanced Waveform & Vector
Scope simultaneously with line select
●Various and User defined Markers
Display & Safe Area
●Programmable 6 User Front Pushbutton
Controls & GPI
●Closed Caption (608/708) N. American
Market
●Cutting edge De-interlacing and scaling
Technology
●Fast Response Time for high motion
video
●Internal Monitor Display (IMD)
●Ethernet & RS232 Remote Control
●Ember+ compliant control system
capabilities
●Underscan / Overscan / Normal / Zoom
●Pixel to Pixel Mode, Tally, DC operation
●False Color and Peaking Filter / Focus
Assist
●Video Range test with adjustable Y & C
values
●Display LTC & DIVTC time code with line
select
●Embedded Audio input, Digital Audio
Decoding
●Internal Pattern Generator and Wall
Control System
Operating Instructions6
SFP-H-7 SERIES with PIPM-R-7-TypeC
6
佧
optional

Re-imagine Beyond Technology sales@plurainc.com
The SFP-H-7 provides comprehensive interoperability capabilities with wide range of third-party IP-FHD media platforms with a seamless end-
to-end production workflow. It can decode multiple SMPTE 2110 & 2022-7 media streams within any broadcast and professional media SDI &
IP 2110 infrastructures.
1026 ,1
Band PHGLD
Control MEDIALAN
Server
10 GigE BACKUP
MAIN Switch 10 GigE
Plura PTP Generator
IEEE 1588-2008 PTPv2 BACKUP Switch 10 GigE
10 GigE MAIN
I36WUHDP3*
IP-Stream-3G
Plura SFP-H-7 monitors are equipped with two generic compatible 10G-
SR SFP+ 850nm digital optical monitoring LC MMF optical transceiver
modules. Dual 10GbE De-Encapsulation channels are fully compatible
with MM and SM SFP modules manufactures. For further details, please
contact Plura tech support.
(PEHU Out-
Band PRQLWRU
Control
CONTROL
LAN
PLURA Out-Band
8VHUInterface Control
SFP-324-H-7 displaying
MEDIALAN Stream Main
SFP-324-H-7 Interface I/O
M(',$/$1 Main
Loop Output 3G
PBM-317-3G Monitor
displaying MEDIALAN
VWUHDP$0DLQLoop out
3G SD,from 6)3324H-7
3. Production Workflow and I/O Connections
1) Production Workflow
Operating Instructions7
SFP-H-7 SERIES with PIPM-R-7-TypeC
7
佧
optional

Re-imagine Beyond Technology sales@plurainc.com
●SFP-324-H-7 / Front Keypad
Figure 1. SFP-324-H-7 Monitor
Figure 2. Front Keypad - Select and Display the PIPM-R-7 IP Stream
(When PIPM-R-7 is installed inside SFP-H or SFP-H-7 unit)
►Select PIPM as Input channel and then select Main or SUB as Output channel.
●Front Keypad Operations
Key Name Operation
STANDBY ►Power ON/OFF Button. This button is operated after being pressed about
3 seconds.
INPUT
SFP1/SFP2/SDI/PIPM
►SFP Modules Input CH selected.
►Channels in the input signal, the key led light.
►Select PIPM as Input channel when PIPM-R-7 is installed
OUTPUT
SFP1/SFP2/SDI/AUX/
MAIN/SUB ►SFP Modules Output CH selected.
ALL ►SFP Modules ALL Output CH selected.
FUNCTION
F1/F2/F3
►Executes functions of user selected.
UNDEF, Aspect, Mono/Blue only, Audio Channel, Safety area marker, Time
code, Analog Caption, Audio mute, Still image, Zoom, Flip, Gamma select,
PIP func & Input, Sub win full, Sub win part
SEL/INPUT
►Activates OSD menu of input source selecting.
►Changes input source by selecting.
►Executes functions (by OSD help commands) in main OSD menu.
►Activates child menu.
MENU
►Activates main OSD menu.
►Navigates higher menu in main OSD menu.
►Exits OSD menu.
Adjust
►Adjust Picture Menu(Brightness -> Contrast -> Color -> Sharpness->Phase
& Tint)
►Turn Right (with „UP' button is same)
►Turn Left (with „DOWN' button is same)
Table 1. Front Keypad Operations
Operating Instructions8
SFP-H-7 SERIES with PIPM-R-7-TypeC
8

Re-imagine Beyond Technology sales@plurainc.com
2) I/O & Connectivity
Figure 3. I/O & Connectivity
PIPM-R-7 I/O Description
Ethernet Port ►Control LAN out-band
Dual SFP+ GigE Ports ►2x 10 GigE SFP+ cages for media LAN
SDI AUX O/P ►1EA Serial Digital , 3Gb/s, 1.485Gb/s, 270Mb/s, BNC Jack
Table 2: SFP-H-7 (PIPM-R-7) I/O
Operating Instructions9
SFP-H-7 SERIES with PIPM-R-7-TypeC
9

Re-imagine Beyond Technology sales@plurainc.com
4. INSTALLATION OVERVIEW
1) Initial Setup by Web Browser
All Plura monitors should be shipped with the latest versions of firmware/software at the time
of production, but in the case where an update is available, follow the appropriate steps below,
Each update is applied using the Control LAN UI. The Media LAN 2110 Control (out-band) is
also accessed via the Control LAN UI. Follow the instructions below to access this interface.
Chrome and Firefox browsers are recommended for control on Windows.
2) Connecting to the Control LAN User Interface “UI”
●Plug in the Ethernet cable to the Control LAN on the back of the monitor.
●Power on the unit and wait for the “PLEASE WAIT EMBER+ BOARD IS BOOTING”
message to go away (Figure 4)
Figure 4. Ember+ Board Booting
●On your Plura monitor, press the “Menu” button.
Select “Setup” →“Advanced” →“Network Config” to find the IP address of the Ember+
board (Figure 5).
Figure 5.
Plura Monitor
Network Config
Menu
Operating Instructions10
SFP-H-7 SERIES with PIPM-R-7-TypeC
10

Re-imagine Beyond Technology sales@plurainc.com
●On your computer, open your web browser and go to the IP address of the monitor
(eg. 192.168.0.97 from the image above). You should see a landing page similar to that
shown in Figure 6 below.
Note: If the unit fails to establish a connection, add a port override to 8086 (suffix ':808
6/home' on the Control LAN IP address in the browser address line). If this connects
properly, please contact Plura Support to get and install the latest web update.
From the Control LAN UI landing page, the “Monitor Update” button is used to update
Ember+ Control, Ember+/TSL License, Monitor FPGA (some models), Monitor
Firmware (some models), and the Web UI itself. The “Media LAN 2110 Control
(out-band)” button is used to access out-band control of the 2110 module.
Figure 6. Plura Control LAN UI
Operating Instructions11
SFP-H-7 SERIES with PIPM-R-7-TypeC
11

Re-imagine Beyond Technology sales@plurainc.com
5. WEB CONFIGURATION & INTERFACE
1) Overview
Once you have established network connectivity with the monitor, you can further configure
and update the monitor and the IP 2110 module through its web interface.
2) Ember+ Control Update
●Download the Ember+ Update software to your computer.
●Open the Control LAN UI Monitor Update page. Refer to section 'Connecting to the
Control LAN UI.
Figure 7. Monitor Update
●Click the “Ember+ Control Update” button.
Figure 8. Ember+ Control Update
Operating Instructions12
SFP-H-7 SERIES with PIPM-R-7-TypeC
12

Re-imagine Beyond Technology sales@plurainc.com
Figure 9. Click inside the box to load a file
●Navigate to the folder with the Software and select the file.
●Once the file is selected, it will show up in the white text box and the Upload button
will now be clickable (no longer grayed out).
●Click the Upload button.
Figure 10. Upload the file
●Once the file is uploaded, the browser will go to a white page with a Reboot button.
●Click the reboot button then wait approximately 30 to 40 seconds before trying to
reconnect to the Control LAN UI.
●The Ember+ Control Update is now complete.
●To check if the Software was updated properly on your Plura monitor, press the “Menu”
button. Select “Setup” →“Advanced” →“Network Config” the F/W version is shown at
the bottom (Figure 11 below, “v.126” in this case).
Operating Instructions13
SFP-H-7 SERIES with PIPM-R-7-TypeC
13
●Click inside of the white box “Select your Ember+ Control Update file”.

Re-imagine Beyond Technology sales@plurainc.com
Figure 11. Network Config
3) Monitor FPGA and Firmware
●Download Firmware and FPGA update files to your computer.
●Open the Control LAN UI. Refer to section 'Connecting to the Control LAN UI'.
●Click on the Left Monitor labeled “Monitor Updates” to access the UI monitor update.
●Click the “FPGA Update” button.
●Click inside of the white box “Select your FPGA File”.
●Navigate to the folder with the FPGA and select all.
●Click on the “Upload” button.
Figure 12. FPGA File Update
●Once the file is uploaded, the browser will go to a white screen with a “reboot” button.
●Click reboot.
●After 30 seconds to a minute, the screen will go black and the standby light may flash
to show that the unit is updating. Wait until the unit resets itself, this may take a few
minutes.
●Click the “Firmware Update” button.
●Click inside of the white box “Select your Firmware File”.
Operating Instructions14
SFP-H-7 SERIES with PIPM-R-7-TypeC
14

Re-imagine Beyond Technology sales@plurainc.com
●Navigate to the folder with the Firmware file and select it.
●Click on the “Upload” button.
Figure 13. Firmware Update
●Once the file is uploaded, the browser will go to a white screen with a “reboot” button.
●Click reboot.
●After 30 seconds to a minute, the screen will go black and the standby light may flash
to show that the unit is updating. Wait until the unit resets itself, this may take a few
minutes.
●On your Plura monitor, press the “Menu” button.
Select “Setup” →“Advanced” →“Information” to check the information page and
ensure that both FPGA and Firmware have been successfully updated (Figure 14).
Figure 14. FPGA and Firmware information menu
Operating Instructions15
SFP-H-7 SERIES with PIPM-R-7-TypeC
15

Re-imagine Beyond Technology sales@plurainc.com
4) Ember+/TSL License Update
To update the license please contact Plura Support. Have the MAC address for your monitor
available prior to contacting the support team. The MAC address can be found on the UI’s top
right corner of the page (shown in Figure 9 below).
●Download the Ember+/TSL License Update file to your computer.
●Open the Control LAN UI Monitor Update page. Refer to section 'Connecting to the
Control LAN UI'.
●Click the “Ember+/TSL License Update” button.
Figure 15. Ember+/TSL License Update
●Click inside of the white box “Select your Ember+/TSL License files”.
Figure 16. Ember+/TSL License File Upload
Operating Instructions16
SFP-H-7 SERIES with PIPM-R-7-TypeC
16

Re-imagine Beyond Technology sales@plurainc.com
●Once the file is uploaded, the browser will go to a white page with a Reboot button.
●Click the reboot button then wait approximately 30 to 40 seconds before trying to
reconnect to the Control LAN UI.
●The Ember+/TSL License Update is now complete.
5) Web UI Update
●Download the Web Update file to your computer
●Open the Control LAN UI Monitor Update page. Refer to section 'Connecting to the
Control LAN UI'.
Figure 17. Plura UI
●Click on the Left Monitor labeled “Monitor Updates” to access the UI monitor update.
●Click the “Web UI Update” button.
●Click inside of the white box “Select your Web UI Update File”.
Figure 18. Web Update and File Selection
Operating Instructions17
SFP-H-7 SERIES with PIPM-R-7-TypeC
17

Re-imagine Beyond Technology sales@plurainc.com
●Navigate to the folder where you saved the Web UI update file and select all.
●Once the file is selected, it will show up in the white text box and the Upload button
will now be clickable (no longer grayed out).
●Click the Upload button.
Figure 19. Upload the Web UI Update File
●Once the file is uploaded, the browser will go to a white screen with a “reboot” button.
●Click reboot.
●The web UI is now upgraded to the latest version. To check the version of your UI,
reconnect to the Control LAN UI. Once the UI is loaded, the version number will be
located on the top right of the page (Figure 20 - it is Version 1.2.2 in this example).
Figure 20. Web UI Version Location
Operating Instructions18
SFP-H-7 SERIES with PIPM-R-7-TypeC
18

Re-imagine Beyond Technology sales@plurainc.com
6. MEDIA LAN 2110 CONTROL (out-band)
1) Overview
Each SFP-H-7 Series Type C Plura monitor defaults to the PIPM input source which is set
to display an internally generated 'blue screen' test signal from the 2110 module. The video
format defaults to 1080i59.94
2) Management via Control LAN UI
●Open the Control LAN UI Media LAN 2110 Control (out-band) page. Refer to section
'Connecting to the Control LAN UI'.
●The Media LAN 2110 Control has two-tab options for out-band control:
Main and Management. Figure 21 below shows the UI Main Tab.
●In the Main tab there are fields to set the Video, Audio, and the Ancillary flows’
configuration. Each flow allows configuration of both its Primary and Secondary fields
and has an Enable check box. Adjustable fields include the destination IP address, the
destination port, and video format (for primary video only, secondary video format is
always the same as the primary video format).
Figure 21. Main Tab
●The management tab offers both DHCP and Static IP configuration. To choose a Static
IP uncheck the DHCP check box (Figure 22). Once the Static IP values are entered click
on the submit button.
Operating Instructions19
SFP-H-7 SERIES with PIPM-R-7-TypeC
19

Re-imagine Beyond Technology sales@plurainc.com
Figure 22. Management Tab
●The management tab also provides the primary and secondary transceiver information
(Figures 23 & 24 below)
Figure 23. Primary Transceiver Information
Figure 24. Secondary Transceiver Information
Operating Instructions20
SFP-H-7 SERIES with PIPM-R-7-TypeC
20
Table of contents
Other Plura Control Unit manuals
Popular Control Unit manuals by other brands

Advantech
Advantech PCM-3347 Series user manual

Sonifex
Sonifex CM-TB8 User handbook

Delta Electronics
Delta Electronics Ethernet Communication Module IFD9507 Applications manual

FAAC
FAAC 596/615 BPR manual

RAKwireless
RAKwireless WisLink-LoRa RAK2245 Pi HAT user manual

Cooper Security
Cooper Security Scantronic 9853 Update guide