Clas Ohlson OXP-3B User manual

English
GREAT BRITAIN • CUSTOMER SERVICE
tel: 0845 300 9799 internet: www.clasohlson.com/uk
e-mail [email protected]
Ver. 20140203
8/18 m Wall Mountable CableReel
Art.no 36-5570 Model OXP-3B
36-5571 OXP-28B
Please read theentire instruction manual before using theproduct and then save it for future reference.
We reserve theright for any errors in text or images and any necessary changes made to technical data.
In theevent of technical problems or other queries, please contact our customer services.
Safety
• The cable reel needs to be mounted close to awall socket and with enough room for it to swivel round.
• Mount thecable reel out of children’sreach.
• If theclicking sound stops when you are unwinding thecable, it means that you have unwound it to
themaximum length. Letalittle of thecable reel wind back onto thereel until it locks inplace.
• Do not overload thecablereel.
• Hold onto thecable whilst it is winding back onto thereel to prevent any injuries.
• If thethermal protection has triggered, let thecable cool before resetting it.
• If thecable does not reel in completely, pull it all theway out and tryagain.
• Do not use thecable reel if thecable or any other part of theproduct is damaged.
Repairs must be carried out by aqualified tradesman or workshop.
Installation
The cable reel should be mounted onto a wall using appropriate screws for the material and bearing
capacity of the wall.
Operating instructions
1. Plug thecable reel into awall socket. TheLED will comeon.
2. Unwind thedesired length of cable; there is aclicking sound when thecable is being unwound.
3. Release thecable to fix thedesired length.
4. After use, pull thecable lightly and let it rewind automatically onto thereel.
If thethermal protection has triggered:
1. Unplug thecable reel from thewall socket.
2. Allow theproduct to cool to room temperature.
3. Push thered button to resetit.
4. Plug thecable reel back into awall socket – theLED should come onagain.
Disposal
This product should be disposed of in accordance with local regulations.
Ifyou are unsure how to proceed, contact your local council.
Specifications
36-5570
Max load Wound 1400W, unwound 2000W
Cable H05VV-F 3G1.5 mm²
Total
cable length 10 m (8 + 2 m)
250V. IP20.
36-5571
Max load Wound 1000W, unwound 3500W
Cable H07RN-F 3G1.5 mm²
Total
cable length 20m (18 + 2 m)
230 V. IP44.

Svenska
SVERIGE • KUNDTJÄNST
tel. 0247/445 00 internet www.clasohlson.se
Ver. 20140203
Kabelvinda för vägg 8/18m
Art.nr 36-5570 Modell OXP-3B
36-5571 OXP-28B
Läs igenom hela bruksanvisningen före användning och spara den sedan för framtida bruk.
Vi reserverar oss för ev. text- och bildfel samt ändringar av tekniska data.
Vid tekniska problem eller andra frågor, kontakta vår kundtjänst.
Säkerhet
• Kabelvindan måste monteras inärheten av ettvägguttag och med tillräcklig svängradie.
• Montera kabelvindan där den inte kan nås avbarn.
• Om inte ettklickljud hörs när du drar ut kabeln beror det på att du har dragit utden
till maxläge, släpp tillbaka den enaning för att fixera.
• Överbelasta inte kabelvindan.
• Håll ikabeln när den automatiskt lindas tillbaka för att undvika att någon blir skadad.
• Om det termiska skyddet har löst ut, låt produkten svalna innan återställning sker.
• Om inte kablen kan rullas tillbaka helt, dra ut den helt och provaigen.
• Om kabeln eller någon annan del av produkten är skadad får den inte användas.
Reparation måste ske av kvalificerad serviceman eller verkstad.
Montering
Kabelvindan monteras på vägg med skruvar lämpliga för väggens material och bärighet.
Användning
1. Anslut stickproppen till ettvägguttag. Lysdioden lyser.
2. Dra ut önskad längd av kabeln, ettklickljud hörs när kabeln drasut.
3. Släpp tillbaka kabeln försiktigt för att fixera den önskade längden.
4. Efter användning, dra lätt ikabeln och låt den automatisk lindas tillbaka på kabelvindan.
Om det termiska skyddet utlösts, gör följande:
1. Dra ut kabelvindans stickpropp ur vägguttaget.
2. Låt produkten svalna till rumstemperatur.
3. Tryck på den röda knappen för att återställa.
4. Sätt istickproppen ivägguttaget igen, lysdioden lyser.
Avfallshantering
När du ska göra dig av med produkten ska detta ske enligt lokala föreskrifter.
Ärdu osäker på hur du ska gå tillväga, kontakta din kommun.
Specifikationer
36-5570
Maxbelastning Inrullad 1400 W, utrullad 2000W
Kabel H05VV-F 3G1,5 mm²
Total kabellängd 10 m (8 + 2 m)
250 V. IP20.
36-5571
Maxbelastning Inrullad 1000 W, utrullad 3500W
Kabel H07RN-F 3G1,5 mm²
Total kabellängd 20 m (18 + 2 m)
230 V. IP44.

Norsk
NORGE • KUNDESENTER
tel. 23 21 40 00 internett www.clasohlson.no
Ver. 20140203
Kabelvinde for vegg 8/18m
Art. nr. 36-5570 Modell OXP-3B
36-5571 OXP-28B
Les brukerveiledningen grundig før produktet tas ibruk og ta vare på den for framtidig bruk.
Vi reserverer oss mot ev. feil itekst og bilde, samt forandringer av tekniske data.
Ved tekniske problemer eller spørsmål, ta kontakt med vårt kundesenter.
Sikkerhet
• Kabelvinden må monteres nær etstrømuttak og med tilstrekkelig svingradius.
• Monter kabelvinden på enplass utenfor barns rekkevidde.
• Hvis man ikke hører et klikk når kabelen dras ut, er den trukket forlangt ut.
Slippden tilbake litt slik at den fester seg.
• Overbelast ikke produktet.
• Hold ikabelen når den vikles inn på vinden igjen. Dettefor åunngå skader.
• Hvis det termiske vernet blir utløst, la produktet avkjøles før produktet stilles tilbake.
• Hvis kabelen ikke vindes helt tilbake, trekk den ut og prøvigjen.
• Hvis noen av delene på produktet skades må man ikke bruke kabelen. Reparasjoner må utføres av
kyndig servicepersonell eller på verksted.
Montering
Kabelvinden monteres på vegg med skruer som er beregnet for veggens materiale og bæreevne.
Bruk
1. Støpselet kobles til etstrømuttak. Lysdioden lyser.
2. Trekk kabelen ut til ønsket lengde. Et klikk høres når kabelen drasut.
3. Slipp kabelen forsiktig for åfå den festet iønsket lengde.
4. Etter bruk trekker man lett ikabelen og den rulles tilbake på kabelvinden.
Hvis det termiske vernet utløses, gjør følgende:
1. Trekk støpselet ut fra strømuttaket.
2. La produktet avkjøles til romtemperatur.
3. Trykk på den røde knappen for åstille produktet tilbake.
4. Sett støpselet istrømuttaket igjen og lysdioden lyser.
Avfallshåndtering
Når produktet skal kasseres, må det skje ihenhold til lokale forskrifter.
Hvisdu er usikker, ta kontakt med kommunen din.
Spesifikasjoner
36-5570
Maksimumsbelastning Oppkveilet 1400 W
Trukket ut 2000W
Kabel HO5VV-F 3G 1,5mm²
Total kabellengde 10 m (8 + 2 m)
250 V. IP20.
36-5571
Maksimumsbelastning Oppkveilet 1000 W
Trukket ut 3500W
Kabel H07RN-F 3G1,5 mm²
Total kabellengde 20 m (18 + 2 m)
230 V. IP44.

Suomi
SUOMI •
ASIAKASPALVELU
puh. 020 111 2222 kotisivu www.clasohlson.fi
sähköposti [email protected]
Ver. 20140203
Kaapelikela seinälle 8/18m
Tuotenumero 36-5570 Malli OXP-3B
36-5571 OXP-28B
Lue käyttöohje ennen tuotteen käyttöönottoa ja säilytä se tulevaa tarvetta varten.
Pidätämme oikeuden teknisten tietojen muutoksiin. Emmevastaa mahdollisista teksti- tai kuvavirheistä.
Jos tuotteeseen tulee teknisiä ongelmia, ota yhteys myymälään tai asiakaspalveluun.
Turvallisuus
• Asenna kaapelikela pistorasian läheisyyteen sellaiseen paikkaan, jossa on riittävästi tilaa kelan pyörimiselle.
• Asenna kaapelikela sellaiseen paikkaan, jossa se on lasten ulottumattomissa.
• Jos kaapelikelasta ei kuulu naksahdusta, kun vedät kaapelia, kaapeli on vedetty enimmäispituuteen.
Päästäkaapelia hieman takaisin kelalle.
• Älä ylikuormita kaapelikelaa.
• Henkilövahinkojen välttämiseksi pidä kiinni kaapelista sen kelautuessa automaattisesti takaisin kelalle.
• Jos ylikuumenemissuoja on lauennut, anna kelan jäähtyä ennen ylikuumenemissuojan palauttamista.
• Jos kaapeli ei kelaudu kokonaan takaisin kelalle, vedä kaapeli kokonaan ulos ja yritä uudelleen.
• Älä käytä kaapelikelaa, jos kaapeli tai muu kelan osa on vioittunut. Ainoastaan ammattilainen saa
korjata kaapelikelan.
Asennus
Kaapelikela asennetaan seinälle ruuveilla, jotka sopivat seinän materiaaliin ja kantokykyyn.
Käyttö
1. Liitä pistoke pistorasiaan. Merkkivalo palaa.
2. Vedä kaapelia kelalta tarvittava määrä. Kaapelikelasta kuuluu naksahdus, kun kaapelia vedetään ulos.
3. Lukitse kaapeli haluttuun pituuteen vapauttamalla kaapeli varovasti.
4. Vedä käytön jälkeen kevyesti kaapelista, jolloin kaapeli kelautuu automaattisesti takaisin kaapelikelalle.
Jos ylikuumenemissuoja on lauennut, teenäin:
1. Irrota kaapelikelan pistoke pistorasiasta.
2. Anna kaapelikelan jäähtyä.
3. Palauta asetukset painamalla punaista painiketta.
4. Aseta pistoke takaisin pistorasiaan. Merkkivalo syttyy.
Kierrättäminen
Kierrätä tuote asianmukaisesti, kun poistat sen käytöstä.
Tarkempia kierrätysohjeita saat kuntasi jäteneuvonnasta.
Tekniset tiedot
36-5570
Suurin kuormitus Kelalle kelattuna 1400 W,
auki kelattuna 2000W
Kaapeli H05VV-F 3G1,5 mm²
Kaapelin kokonaispituus 10 m (8 + 2 m)
250 V. IP20.
36-5571
Suurin kuormitus Kelalle kelattuna 1000 W,
auki kelattuna 3500W
Kaapeli H07RN-F 3G1,5 mm²
Kaapelin kokonaispituus 20 m (18 + 2 m)
230 V. IP44.

DEUTSCHLAND •
KUNDENSERVICE
Unsere Homepage www.clasohlson.de besuchen und
auf Kundenservice klicken.
Deutsch
Ver. 20140203
Kabelaufroller für Wandmontage 8/18m
Art.Nr. 36-5570 Modell OXP-3B
36-5571 OXP-28B
Vor Inbetriebnahme diekomplette Bedienungsanleitung durchlesen und aufbewahren.
Irrtümer, Abweichungen und Änderungen behalten wir unsvor. Bei technischen Problemen oder anderen
Fragen freut sich unser Kundenservice über eine Kontaktaufnahme.
Sicherheitshinweise
• Den Kabelaufroller in der Nähe einer Wandsteckdose und mit ausreichendem Schwenkradius montieren.
• Den Kabelaufroller so montieren, dass er von Kindern nicht erreicht werden kann.
• Ist beim Herausziehen des Kabels kein Klicken zu hören, ist es bereits komplett ausgezogen.
ZumFeststellen etwas nachgeben.
• Den Kabelaufroller nicht überbeanspruchen.
• Um zu verhindern, dass Personen verletzt werden, dasKabel beim automatischen Aufrollen festhalten.
• Sollte der thermische Schutz ausgelöst haben, dasProdukt vor der Rücksetzung abkühlen lassen.
• Falls dasKabel nicht vollständig aufgerollt wird kann es vollständig herausgezogen werden um den
Aufrollvorgang erneut zu starten.
• Wenn dasKabel oder andere Teile des Produkts beschädigt sind, dasProdukt nicht verwenden.
Reparaturen nur von einem qualifizierten Servicetechniker oder einer Werkstatt durchführen lassen.
Montage
Der Kabelaufroller wird mit Schrauben an der Wand befestigt, die dem Wandmaterial und dessen
Tragfähigkeit angepasst sind.
Benutzung
1. Den Netzstecker in eine Steckdose stecken. DieLED leuchtet.
2. Das Kabel bis zur gewünschten Länge herausziehen. BeimHerausziehen ist ein Klicken zuhören.
3. Zum Feststellen der gewünschten Länge etwas nachgeben.
4. Nach der Benutzung leicht am Kabel ziehen um es automatisch zurück auf den Kabelaufroller rollen
zu lassen.
Sollte der thermische Schutz ausgelöst haben, wie folgt vorgehen:
1. Den Netzstecker des Kabelaufrollers aus der Steckdose ziehen.
2. Das Produkt auf Zimmertemperatur abkühlen lassen.
3. Zur Wiederherstellung auf dierote Taste drücken.
4. Den Netzstecker wieder in dieSteckdose stecken, dieLED leuchtet.
Hinweise zur Entsorgung
Bitte dasProdukt entsprechend den lokalen Bestimmungen entsorgen. Weitere Informationen sind von
der Gemeinde oder den kommunalen Entsorgungsbetrieben erhältlich.
Technische Daten
36-5570
Max. Belastung Eingerollt 1400 W,
ausgerollt 2000W
Kabel H05VV-F 3G1,5 mm²
Gesamtkabellänge 10 m (8 + 2 m)
250 V. IP20.
36-5571
Max. Belastung Eingerollt 1000 W,
ausgerollt 3500W
Kabel H05RN-F 3G1,5 mm²
Gesamtkabellänge 20 m (18 + 2 m)
230 V. IP44.
This manual suits for next models
3
Table of contents
Languages:
Other Clas Ohlson Cables And Connectors manuals

Clas Ohlson
Clas Ohlson CEHSP0102-UK User manual

Clas Ohlson
Clas Ohlson OXP-3B User manual

Clas Ohlson
Clas Ohlson KT-5153 User manual

Clas Ohlson
Clas Ohlson LCH1312.68-3P User manual

Clas Ohlson
Clas Ohlson LCH1312.68-3P User manual

Clas Ohlson
Clas Ohlson 2180-4313 User manual

Clas Ohlson
Clas Ohlson LCH1312.68-3P User manual

Clas Ohlson
Clas Ohlson PL-ASAO-B User manual