manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cleveland
  6. •
  7. Iron
  8. •
  9. Cleveland 24-SM User manual

Cleveland 24-SM User manual

Other Cleveland Iron manuals

Cleveland 42CKSM Series User manual

Cleveland

Cleveland 42CKSM Series User manual

Cleveland 24-GM-K10-200 User manual

Cleveland

Cleveland 24-GM-K10-200 User manual

Cleveland 36-EM-K36 User manual

Cleveland

Cleveland 36-EM-K36 User manual

Cleveland SteamPro XVI 36-PCSM User manual

Cleveland

Cleveland SteamPro XVI 36-PCSM User manual

Cleveland SteamPro XVI 36-PCEM-48 User manual

Cleveland

Cleveland SteamPro XVI 36-PCEM-48 User manual

Cleveland 24-GM-K6-200 User manual

Cleveland

Cleveland 24-GM-K6-200 User manual

Cleveland 24CGA6.2S Instruction Manual

Cleveland

Cleveland 24CGA6.2S Instruction Manual

Cleveland 36-CEM-24 User manual

Cleveland

Cleveland 36-CEM-24 User manual

Cleveland 24-EM-24 User manual

Cleveland

Cleveland 24-EM-24 User manual

Cleveland 24-GM-200 User manual

Cleveland

Cleveland 24-GM-200 User manual

Cleveland 24-GM-K6-200 User manual

Cleveland

Cleveland 24-GM-K6-200 User manual

Cleveland SteamPro XVI 36-PCGM-300 User manual

Cleveland

Cleveland SteamPro XVI 36-PCGM-300 User manual

Cleveland 36-EM-K11-24 User manual

Cleveland

Cleveland 36-EM-K11-24 User manual

Popular Iron manuals by other brands

Lelit PG024N manual

Lelit

Lelit PG024N manual

Imetec INTELLIVAPOR K1 operating instructions

Imetec

Imetec INTELLIVAPOR K1 operating instructions

Hoyer DB 1750 C3 operating instructions

Hoyer

Hoyer DB 1750 C3 operating instructions

Singer SteamLogic instruction manual

Singer

Singer SteamLogic instruction manual

Russell Hobbs RHI007 Instructions and warranty

Russell Hobbs

Russell Hobbs RHI007 Instructions and warranty

Philips GC2900 series user manual

Philips

Philips GC2900 series user manual

Clatronic DB 3703 instruction manual

Clatronic

Clatronic DB 3703 instruction manual

TEFAL FV4093Z0 manual

TEFAL

TEFAL FV4093Z0 manual

Gorenje SIH 2200 BS instruction manual

Gorenje

Gorenje SIH 2200 BS instruction manual

Maxwell MW-3010 Manual instruction

Maxwell

Maxwell MW-3010 Manual instruction

Primula Vapormat instruction manual

Primula

Primula Vapormat instruction manual

Magio MG-541 manual

Magio

Magio MG-541 manual

Bosch Sensixx B22L manual

Bosch

Bosch Sensixx B22L manual

Philips GC651 Specifications

Philips

Philips GC651 Specifications

Vitek VT-1247 VT Manual instruction

Vitek

Vitek VT-1247 VT Manual instruction

Cleanmaxx 3397 instruction manual

Cleanmaxx

Cleanmaxx 3397 instruction manual

Philips GC800 user manual

Philips

Philips GC800 user manual

dyras ESI-2400AC instruction manual

dyras

dyras ESI-2400AC instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Cleveland
™
Project ________________________________
Item __________________________________
Quantity_______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
1333 East 179 St.,
Cleveland, Ohio,U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site:www.ClevelandRange.com
Email: Steam@ClevelandRange.com
MODULAR BASES
MODEL:c24-SM
Cleveland Standard Features
nType 430 Stainless Steel exterior enclosure and Table Top
n6" Stainless Steel Legs with level adjustment with flanged
feet
nSolid State steam generator Water Level Controls
nLow Water Power Cut-off
nPressure Limit Controls with 15 psi Safety Valve
nMajor Components serviceable from the front of unit
nSteam Generator empties under pressure (blowdown)
automatically upon each Shut-Down. Automatic Water
Refill on Start-Up
nSeparate "Start/Reset" Illuminated switch controls, plus
Pressure Gauge
nSteam Generator Drain incorporates Water Cooling and
"Jet/Rinsing"
nSteam Generator is complete with Access Hole/Cover Plate
and Sight Glass Gauge
nSecondaryLowWater Cut-Off, factory installed (CALS)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI.
MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY,
Wash. DC)
nStandard voltage is 115 volt, 60 Hz, single phase
nSingle cold water connection (no hot water required)
Options & Accessories
pVoltages for controls other than standard
pStainless Steel Base Frame (FSS)
Shall be CLEVELAND, Modular Cabinet Base with Steam Coil Steam
Generator Model _____ -SM. Type 430 Stainless Steel exterior enclosure,
Table Top and four Level Adjustable Legs. Console mounted controls,
Pressure Gauge and "Start/Reset" control switches.Solid State Water Level
Steam Generator Controls. Steam Generator drains under pressure (blow-
down) after each Shut-Down, Automatic Water Fill on Start-Up. 15 psi Safety
Valve.
Short Form Specifications
SECT. VII PAGE 5
0707
MODULAR CABINET BASE
STEAM COIL STEAM GENERATOR
24" (600 MM) or 36" (900 MM) WIDE BASE
3/4” IPS. Do not connect
to common drain.
Do not use PVC pipe for drain.
100 watts
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, NSF and UL.
(NOT TO SCALE)
SECT
.VII P
AGE 6
0707
Litho in U.S.A.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it
will be suitable for the generator.
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if
adjoining wall or equipment
is over 30” high for service
access)
Contact factory for
variances to clearances.