manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CMP
  6. •
  7. Water Filtration System
  8. •
  9. CMP Powerclean Ultra VS User manual

CMP Powerclean Ultra VS User manual

®
TM
ULTRA VS
CUSTOM MOLDED PRODUCTS | 36 HERRING ROAD, NEWNAN, GA 30265 | WWW.C-M-P.COMsb0316
CHLORINE FEEDER ENGINEERED FOR VARIABLE SPEED PUMPS
CMP# 25280-15X-000, 25280-16X, 25280-17X, 25280-45X, 25280-46X
READ ALL INFORMATION BEFORE PROCEEDING WITH ANY INSTALLATION. THE INFORMATION WILL HELP YOU INSTALL YOUR FEEDER PROPERLY AND AVOID PROBLEMS.
The Powerclean Ultra VS feeder comes with the Powerclean VS Low Flow Inlet, Cone and Outlet pre-installed. These are for systems with 2-speed or variable speed pumps
where the system ow is less than 50 gpm at the lower speed. If the system uses only a single speed pump, or the low speed is over 50 gpm, remove the inserts.
INSTALLATION GUIDELINES
• Make sure all pumps and timer switches are OFF. The feeder is designed for permanent installation in the return line of the pool or spa and must always be installed
after the heater, pool cleaner, valves, lter and all other equipment. Feeder should be installed above the water level. IMPORTANT: Heaters and other equipment may
be damaged by highly chlorinated water.
•If the pool/spa is plumbed with 2" PVC pipe make sure the pump, heater and lter all have 2" inlet and outlet ttings. Glue 2" PVC pipe into feeder inlet and outlet.
When using 1.5” PVC pipe, follow instructions above but glue into 1.5" unions
•When plumbing a pool/spa combo where the plumbing and equipment is 2" PVC and the feeder is installed on the pool return line after the diverter valve with a
portion of the water going to the spa, install a minimum section of 6" × 1.5" PVC pipe directly into the inlet side of the feeder using the 1.5" unions. Continue with 2"
PVC pipe on the outlet side of the feeder. This will compensate for the water being diverted.
• When plumbing 90 degree elbows directly into the feeder inlet it may cause turbulence inside the elbow which prevents water from entering the feeder. A minimum
of 6" PVC pipe should be installed between the elbow and the inlet of the feeder.
•The arrows on feeder inlet and outlets should point in the direction of the water ow returning to the pool/spa.
• Use only PVC cement. Follow the directions on the cement label. Allow time for the PVC cement to completely dry.
This feeder is designed to use only Trichlor-s-triazinetrione OR Bromine tablets- slow dissolving type. UNDER NO CIRCUMSTANCES MIX Trichlor
or Bromine with Calcium Hydrochlorite, with other forms of concentrated chlorine or with other chemicals. FIRE AND/OR EXPLOSION MAY
RESULT. NEVER use oilsor grease to lubricate o-ring. Oil in contact with Trichlor OR Bromine may result in FIRE. Lubricate o-ring with approved
silicone o-ring lubricant only. If you are not the original owner of this feeder, or not sure which chemical was used, be SAFE and ush thoroughly
with fresh water. CAUTION SHOULD BE USED WHEN REMOVING CAP. DO NOT INHALE FUMES. IF YOUR POOL OR SPA HAS COPPER PLUMBING
DO NOT INSTALL. This will damage the feeder. NOTE: If heaters are used, a Fireman’s Switch or equivalent must be installed to prevent possible
damage and improper operation of check valve and other equipment subject to heat damage.
WARNING
OPERATING INSTRUCTIONS
Fill the feeder with water making sure to bleed out any entrapped air in any of the lines. To ensure maximum
eectiveness, before starting the feeder the pool should be properly conditioned and the residual should be 1.0
to 1.5 ppm. Consult your local dealer for water conditioning information in your area.
1. Remove cap of feeder and ll with proper size tablets. For pools use 1" or 3" diameter tablets. For spas use
1" tablets.
2. If more chemical and a faster dissolve rate is desired, install the included chemical feeder tube at this time.
The elbow of the feeder tube will t into the outlet hole near the inside bottom of unit. If less chemical is
desired, remove the chemical feeder tube.
3. Completely ll the chlorinator with water. Replace cap making sure o-ring is clean, lubricated and in place.
4. Turn on pump and timer switches for a minimum of 6 to 8 hours. The water level inside chlorinator will be
3 – 5 inches under normal running conditions.
5. Adjust the control valve clockwise for more chemical or counter clockwise for less chemical according to
the size of the pool/spa. Use a test kit to determine the chemical residual. Check the chemical residual be
checked daily for the rst ve days. NOTE: Hot weather, high water temperature and increased use will
cause the pool/spa to use more chemical. Increase the feed rate a few days in advance when possible. The
valve settings may require adjustment depending on the conditions.
RECHARGING THE FEEDER
1. Turn control valve to the closed position (counter clockwise). SHUT OFF PUMP.
2. Wait one minute allowing the water and fumes to drain from the feeder.
3. Leave the control valve closed and turn on the pump. (The check valve will prevent water from entering the
feeder).
4. Remove cap and ll with tablets.
5. Replace cap making sure o-ring is clean, lubricated, and in place.(Hand tighten only).
6. Open control valve (clockwise) to original setting.
WINTERIZING THE FEEDER
This chlorinator has a drain plug located on the
bottom for easy draining of the unit for winter. Follow
other normal procedures for your system to winterize.
SPECIAL INSTRUCTIONS:
1. If the feeder does not provide enough chemical
residual when using 3” tablets, switch to 1” tablets
for faster erosion and increased residual.
2. If the glass lid becomes cloudy, turn o the
feeder using the shut o instructions above
(RECHARGING FEEDER). Remove the lid and wipe
clean. If it remains cloudy, it will clear itself if left
exposed to sunlight and fresh air. DO NOT leave
chlorinator open without the lid installed. If the lid
must be left o to clear up, a replacement must
be installed temporarily
3. The bottom grate (#1 in diagram on page 2) is
designed to be removed easily when chlorine
is gummed up inside the unit. The chlorine
residue must be dislodged or it may eect feeder
performance. The grate helps keep pieces of the
tablets from clogging the outlet. Be sure to check
its position after each recharging as the grate
may come out of its resting place when tablets
are added to the chlorinator.
CUSTOM MOLDED PRODUCTS | 36 HERRING ROAD, NEWNAN, GA 30265 | WWW.C-M-P.COM1113sb
CMP P/N DESCRIPTION
1 25280-100-005 GRATE
2 25280-000-920 CHECK VALVE ASSY
3 21023-000-000 2” UNION
4 25280-100-955 FLOW INDICATOR ASSY
5 25280-000-910 NUT
6 26100-100-330 O-RING, DIAL
7 25280-100-001 COVER NUT
7-8 25280-109-200 CLEAR GLASS COVER ASSY
7-8 25280-100-200 WHITE COVER ASSY
7-8 25280-100-002 CLEAR PLASTIC COVER ASSY
9 26101-060-530 O-RING, COVER
10 21023-030-000 UNION GASKET
11 25376-900-500 DRAIN PLUG W/ O-RING
12-14 25280-100-100 VS INSERT KIT
1
24
5
6
7
8
9
12
13
14
3
10
REPLACEMENT PARTS DIAGRAM
0.2
0.0
20 30 40 50 60 70
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
MAX RECOMMENDED
LOW SPEED SYSTEM GPM
CHLORINATOR GPM
SYSTEM GPM
POWERCLEAN ULTRA VS PERFORMANCE
TYPICAL CHLORINATOR PERFORMANCE
POWERCLEAN ULTRA VS PERFORMANCE CHART
Use only Trichlor-s-triazinetrione OR
Bromine tablets - slow dissolving type.
UNDER NO CIRCUMSTANCES MIX
Trichlor or Bromine with Calcium
Hydrochlorite, with other forms of
concentrated chlorine or with other
chemicals. FIRE AND/OR EXPLOSION
MAY RESULT.
NEVER use oils or grease to lubricate
o-ring. Oil in contact with Trichlor OR
Bromine may result in FIRE.
WARNING

This manual suits for next models

5

Other CMP Water Filtration System manuals

CMP DEL Ozone 25 Operating instructions

CMP

CMP DEL Ozone 25 Operating instructions

CMP 25504-600-00 User manual

CMP

CMP 25504-600-00 User manual

CMP DEL AOP PRO 200 User manual

CMP

CMP DEL AOP PRO 200 User manual

Popular Water Filtration System manuals by other brands

Lutz Jesco Easychlorgen 4250 Installation, operation & maintenance instructions

Lutz

Lutz Jesco Easychlorgen 4250 Installation, operation & maintenance instructions

Omnifilter US2000 installation instructions

Omnifilter

Omnifilter US2000 installation instructions

Hayward XStream Manuel du propriétaire

Hayward

Hayward XStream Manuel du propriétaire

Sharp FZ-S63MF Operation manual

Sharp

Sharp FZ-S63MF Operation manual

Beko CLEARPOINT S040 Installation & operation instructions

Beko

Beko CLEARPOINT S040 Installation & operation instructions

Teesa TSA0102 owner's manual

Teesa

Teesa TSA0102 owner's manual

Propur ProMax PMC-4000 instructions

Propur

Propur ProMax PMC-4000 instructions

Watts Pure H2O Series Installation, operation and maintenance manual

Watts

Watts Pure H2O Series Installation, operation and maintenance manual

Pentair EVERPURE EZ-RO 200/2G Installation & operation guide

Pentair

Pentair EVERPURE EZ-RO 200/2G Installation & operation guide

Aqua Medic Systemfilter Skim Operation manual

Aqua Medic

Aqua Medic Systemfilter Skim Operation manual

Grunbeck ultraliQ:SB500 Operation manual

Grunbeck

Grunbeck ultraliQ:SB500 Operation manual

AQUA SZUT AQUA 2 instruction manual

AQUA SZUT

AQUA SZUT AQUA 2 instruction manual

Miltenyi Biotec autoMACS Pro user manual

Miltenyi Biotec

Miltenyi Biotec autoMACS Pro user manual

MEMON memonizerFLATWATER quick start guide

MEMON

MEMON memonizerFLATWATER quick start guide

Jandy SFTM22-1.5 Installation and operation

Jandy

Jandy SFTM22-1.5 Installation and operation

Bauer FAN Separator Green Bedding Service manual

Bauer

Bauer FAN Separator Green Bedding Service manual

Flocell XFM 900 Installation & operating manual

Flocell

Flocell XFM 900 Installation & operating manual

resideo Braukmann MiniPlus FF06 installation instructions

resideo

resideo Braukmann MiniPlus FF06 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.