Cobra GLOBE 3100 User manual

MANUALE INSTALLAZIONE GLOBE 3100
GLOBE 3100 FITTING INSTRUCTION
DELTA ELETTRONICA s.p.a.
via Astico 41 - 21100 VARESE - ITALY
www.cobra.it
01/0206DE1467B

TOGLIERE
LA
PARTE
CENTRALE
CONTENENTE
GLI
SCHEMI
ELETTRICI
DI
MONTAGGIO
.
PULL
OUT
THE
CENTRAL
SECTION
WITH
THE
INSTALLATION
CIRCUIT
DIAGRAMS
.
GLOBE3100
2
Notes

GLOBE3100 MANUALE INSTALLAZIONE 3
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓✓
✓✓✓✓ ✓✓✓✓
✓✓✓✓ ✓✓✓✓
✓✓✓✓ ✓✓✓✓
✓✓
✓✓
✓✓
✓✓✓✓ ✓✓✓✓
✓✓✓✓ ✓✓✓✓
✓✓✓✓ ✓✓✓✓
✓✓✓✓ ✓✓✓✓
✓✓✓✓ ✓✓✓✓
✓✓
✓✓✓✓
✓ ✓ ✓✓✓✓
✓✓✓✓ ✓✓✓✓
✓✓
✓
✓
✓
THATCHAM APPROVED
FITTING INSTRUCTION GLOBE3100
26
CARATTERISTICHETECNICHEDELSISTEMA
Tensione di alimentazione nominale 12VDC
Tensione di esercizio 9/16VDC
Consumo per configurazione standard
(allarme con sensore ultrasuoni, arresto motore e LED) a 12 VDC
- disinserito < 9 mA
- inserito < 16 mA
Temperatura d’esercizio centrale -40/+85 °C
Temperatura d’esercizio sirena -40/+105 °C
Potenza acustica >115 dB(A) a 1 m
SYSTEM TECHNICAL SPECIFICATIONSSYSTEM TECHNICAL SPECIFICATIONS
SYSTEM TECHNICAL SPECIFICATIONSSYSTEM TECHNICAL SPECIFICATIONS
SYSTEM TECHNICAL SPECIFICATIONS
Ratedsupplyvoltage 12VDC
Operation supply voltage 9/16VDC
Consumption by standard configuration
(alarm with ultrasonic sensor, engine cut-off and LED) at 12 VDC
-disarmed < 9 mA
- armed < 16 mA
Alarm unit operating temperature -40/+85 °C
Siren operating temperature -40/+105 °C
Acoustic power >115 dB(A) a 1 m
Il sistema é conforme alle seguenti regolamentazioni /
The system conforms to the following
regulations:
DIRETTIVE EUROPEE /
EUROPEAN DIRECTIVES
Commission Directive 95/56/EC of 8 November 1995
Commission Directive 95/54/EC of 31 October 1995
Commission Directive 89/336 /EEC of 3 May 1989

MANUALE INSTALLAZIONE GLOBE3100
4
INTRODUZIONE
Questomanuale contienetutte leinformazionirelativealleoperazioni chesono richiesteper installare
il sistema di allarme e per configurarlo come richiesto dal cliente e/o dalle disposizioni normative
del Vostro Paese. Per la descrizione delle singole funzioni fare riferimento al manuale utente.
Dovrà essere Vostra cura indicare sul manuale utente la programmazione eseguita.
Ribadiamo che la descrizione delle singole funzioni è riportata nel manuale utente, mentre in
questo manuale sono riportate alcune note cui fare riferimento durante l’installazione.
Elencodellefunzionistandard(nonprogrammabili)
Di seguito sono elencate le caratteristiche funzionali principali dell’allarme, che non è
possibile attivare/disattivare e personalizzare.
• Inserimento/disinserimento per mezzo di radiocomandi a codice dinamico.
• Protezione volumetrica dell’abitacolo con sensore ad ultrasuoni che non necessita di
regolazioni della sensibilità.
• Protezione perimetrica. Ad allarme inserito, dopo 40 s., la sirena suona se una porta, il
cofano o il baule viene aperto.
• Protezione da tentativi di avviamento. Ad allarme inserito il motore è bloccato ed il tentativo
di avviamento genera allarme.
• Quando si verifica un allarme la sirena suona per 30 s. ad una potenza maggiore di 115 dB
(@ 1 m). Gli indicatori di direzione lampeggiano.
• Comando del sistema originale di chiusura centralizzata di porte e baule.
• LED di indicazione dello stato del sistema con funzione di memoria avvenuti allarmi
• Segnalazione batteria del radiocomando scarica
• Un circuito di sicurezza impedisce l’inserimento del sistema a motore in moto.
• Allarme panico
• Esclusione ultrasuoni e/o di un eventuale sensore esterno da radiocomando
• Autoapprendimento di radiocomandi
• Disinserimento di emergenza con pin-code
• Protezione taglio cavi
• Funzione garage
Elencodellefunzionibase(programmabili)
Sono le funzioni che richiedono di essere programmate in funzione del modello di vettura e
delle modalità di funzionamento dell’allarme desiderate.
Fate riferimento alla TABELLA FUNZIONI BASE delle tavole di programmazione.
• Tempo chiusure centralizzate
• Chiusura vetri confort controllata
• Segnalazione porte/cofano/baule aperti
• Blinker inserimento/disinserimento
• Inserimento automatico allarme
• Inserimento automatico antiavviamento
• Allarme antiavviamento
GLOBE 3100 FITTING INSTRUCTION 25
mod. 7777
A
B
Carry out the test operations in the indicated
sequence.
FUNCTIONAL TEST OF THE
PERIMETRIC PROTECTION
Insert a hand into the passenger
compartment and wave it about,
in the areas you want to test, if
the sensor is working correctly
the LED will stop flashing while
it detects movement.
Arm the system pressing "A" button
of the radio control. Verify that in the
passengers compartment there is no
moving obiect. Close doors, bonnet
and boot leaving two windows
opened by around 10 cm..
Rearm the alarm and slap the
windows with the palm of your
hand. The LED must continue to
flash, uninterupted.
Disarm the alarm pressing "A"
button and close the windows.
Wait 40 s..
Open a door with the key.
The siren will sound and the turn
indicators will flash.
Close the door.
Arm the alarm by pressing button
A button of the radio control. The
turn indicators will flash twice, the
buzzer will beep twice (if
activated).
The doors will lock.
The LED will flash.
Disarm the alarm by pressing
button A on the radio control.
The turn indicators will flash four
times (alarm memory).
The doors will unlock and the LED
will switch to flashing the alarm
memory display.
FUNCTIONAL TEST FOR THE
VOLUMETRIC ULTRASONIC SENSOR
(IF FORESEEN)
mod. 7779
A
B
Repeat the test for the other
doors, bonnet and boot.
Carry out the test operations in the indicated
sequence. An alarm status will be generated
(siren and blinker) once this time has elapsed.

GLOBE3100 MANUALE INSTALLAZIONE 5
Elencodellefunzioniavanzate(programmabili)
Sono funzioni particolari che richiedono di essere programmate secondo le modalità di
funzionamento dell’allarme desiderate.
Fate riferimento alla TABELLA FUNZIONI AVANZATE delle tavole di programmazione.
• Antidistrazione immobilizzatore
• Antidistrazione allarme
• Chiusura porte da antidistrazione allarme
• Autolock - blocco automatico porte
• Autolock - selezione modalità blocco automatico porte
• Antirapina automatica
• Antirapina volontaria
• Blocco motore antirapina controllato da sensore di movimento
Elencodellefunzionidiselezioneavvisatoreacustico
Si può configurare l’uscita di comando dell’ avvisatore acustico in modo tale da poter collegare
un clacson (uscita intermittente) oppure selezionare uno dei quattro suoni sirena:
•Monotonale fissa
•Monotonale alternata
•Bitonale
•Con segnale modulato in frequenza
Fate riferimento alla TABELLA SIRENE delle tavole di programmazione.
FUNZIONALITA’DEIPULSANTIDELRADIOCOMANDO
Pulsante APulsante A
Pulsante APulsante A
Pulsante A Inserisce/disinserisce l’allarme e l’immobilizzatore, consente l’accesso alla
programmazione, seleziona la linea e aumenta il volume del buzzer nelle
tabelle di programmazione
Pulsante BPulsante B
Pulsante BPulsante B
Pulsante B Panico, attiva disattiva antirapina volontaria, disattiva l’immobilizzatore,
esclude l’ingresso volumetrico e l’ingresso sensori supplementari, attiva/
disattiva la funzione e diminuisce il volume del buzzer nelle tabelle di
programmazione.
ATTENZIONE!ATTENZIONE!
ATTENZIONE!ATTENZIONE!
ATTENZIONE!
Questo prodotto é configurato per soddisfare i requisiti della Direttiva Europea per i sistemi di
allarme. L’utilizzazione della funzione buzzer é consentita solo per i mercati extra CE.
L’attivazione invalida l’omologazione.
Prima di iniziare l’installazione scollegare il cavo negativo dalla batteria e ricollegarloPrima di iniziare l’installazione scollegare il cavo negativo dalla batteria e ricollegarlo
Prima di iniziare l’installazione scollegare il cavo negativo dalla batteria e ricollegarloPrima di iniziare l’installazione scollegare il cavo negativo dalla batteria e ricollegarlo
Prima di iniziare l’installazione scollegare il cavo negativo dalla batteria e ricollegarlo
solo ad installazione ultimata.solo ad installazione ultimata.
solo ad installazione ultimata.solo ad installazione ultimata.
solo ad installazione ultimata.
Questosistemaé compatibileconveicolia motorecheabbianobatteria a12Vcon negativoamassa.
FITTING INSTRUCTION GLOBE3100
24
VEHICLESPEED SENSOR(VSS)
The VSS is a signal which frequency is proportional to the speed of the vehicle (normally is
a square signal f max = 4 KHz).
If the activated function requires it, the VSS signal must be connected to the PINK/BLACK
wire of the alarm.
In some vehicles this signal must be taken directly on the tachymeter. The signal should not
be taken on ABS control system or on control circuits to prevent any vehicle malfunctions.
CENTRALDOORLOCKING CONNECTION
The central door locking control wires can be connected in different way to control the
various CDL systems. Refer to the center pages for the different application diagrams.

MANUALE INSTALLAZIONE GLOBE3100
6
POSIZIONAMENTODEGLIELEMENTIDELSISTEMA
Tutti gli elementi del sistema devono essere posti in posizioni difficilmente accessibili e lontane
da fonti di calore.
Centraled’allarme
Dafissare all’internodell’abitacolo utilizzando ilbi-adesivo fornitonel kited avendocuradi orientare
il connettore principale verso il basso.
Sirena autoalimentata
Da fissare all’interno del
vano motore avendo cura
diorientarla comeindicato.
Sirenanonautoalimentata
Da fissare all’interno del vano motore avendo cura di fissarla
mediantele apposite vitiad unasuperficie metallica chefavorisca la
dissipazione termica del magnete.
Sensorevolumetricoad ultrasuoni(seprevisto)
Le testine possono essere installate sulla parte alta dei montanti del parabrezza anteriore o
del lunotto posteriore, avendo cura che non vengano coperte quando le alette parasole sono
abbassate. Nel caso la vettura sia dotata di tetto apribile non è consigliabile installare le testine
sul piano del cruscotto.
Determinareil correttoorientamentodelle testinedurante l’esecuzionedeltest funzionaledel sistema.
Questo allarme incorpora un sensore che non richiede alcuna regolazione. Si adatta ad ogni tipo
di vettura indipendentemente dalla volumetria dell’abitacolo.
Sensoredirotturavetri(seprevisto)
Si raccomanda di posizionare il relativo microfono in posizione centrale della vettura, meglio se sul
cruscottoorientatoversoil lunottoposteriore.Questoposizionamento consentediottenereuna sensibilità
uniforme.Ilsensore puòessereutilizzato ancheincombinazionecon ilsensorevolumetrico adultrasuoni.
Perle diversemodalitàdi collegamentoriferirsi aidisegniinseriti alcentro delmanuale.
1
2
3
4
Ø 3 mm.
NO
O.K.
GLOBE 3100 FITTING INSTRUCTION 23
AUTO-LEARNINGPROCEDUREFORNEWREMOTE CONTROLS
If a remote control is lost or fails, it is possible to replace it in a secure way as the procedure
is only possible according special conditions.
If you have at least one working remote control, proceed as follow:
1. Disarm the system
2. Open a door and the bonnet
3. Turn the ignition key ON
4. Keep button ‘A’ of the remote control pressed: the turn indicators will flash once
5. Enter the PIN code
6. The turn indicators will come on for 2 s and the LED will illuminate permanently, indicating
that you have entered the auto-learning procedure.
7.
Press both buttons of the new radio control to be added to the system. The transmitter
led will flash.
Keep the buttons pressed until the led goes off.
8. Release the buttons and the led will illuminate permanently.
9. Press button ‘A’ of the remote control, make sure that its led blinks and that the led of the
emergency panel goes out for 1 s; the direction lights should also blink to confirm that the
new remote has been stored in the system
10. Repeat steps 7-8-9 for all the radio controls for the system. All existing radio controls
must be retaught at this point.
11. If no more operations are done within 30 s, the system automatically goes out of the
auto-learning procedure giving a long blink of the turn indicators.
12. To exit of the auto-learning procedure at any time, just turn the ignition OFF.
ATTENTION!
If you don’t have any working remote control proceed as follows:
A. Disarm the system entering the PIN code.
B. Disconnect the unit power supply (disconnect the connector)
C. Open a door and the bonnet
D. Turn the ignition ON
E. Reconnect power supply
F. Enter the PIN code
G. The system confirms the correct code: the led comes on for 2 s.
H. After 5 s. the led will start blinking showing that the system has gone into the self-
learning procedure.
I. Repeat steps 7-8-9 of the main self-learning procedure for all remotes you want to add.
Note: When a new radio control is added to the system it will automatically delete all old
radio controls. If you want to keep them working you must reteach the old radio controls. A
maximum of 4 radio controls can be programmed.

GLOBE3100 MANUALE INSTALLAZIONE 7
Pulsantecofano
L’installazione del pulsante è indispensabile per consentire l’accesso alle procedure di
programmazione dell’allarme e autoapprendimento dei radiocomandi.
Ad installazione ultimata controllare che il pulsante sia premuto dal cofano per almeno 5 mm.
Controllare che il pulsante non vada a premere su pannelli fonoassorbenti o sulla lamiera
esterna della carrozzeria, poiché questi materiali potrebbero deformarsi nel tempo.
Antenna
Il posizionamento dell’antenna è fondamentale ai fini del buon funzionamento del sistema di
radiocomando.
Il cavo non deve essere tagliato, arrotolato, collegato ad altro cavo o alla carrozzeria e deve
essere mantenuto separato dal cablaggio. Posizionare l’antenna in modo che sia distante
almeno 20 mm. da parti metalliche.
Pannellodiemergenza
Da installare sul cruscotto in modo tale che il pulsante sia raggiungibile ed il LED visibile anche
dall’utente. Infatti oltre ad avere una funzione deterrente il pannello (LED + pulsante) viene
utilizzato durante le operazioni di programmazione e per quelle di riconoscimento dell’utente.
COLLEGAMENTIELETTRICI
Fare riferimento agli schemi allegati tenendo presente quanto segue:
• Posizionare il cablaggio dell’allarme insieme al cablaggio originale del veicolo.
• La massa deve essere derivata da un punto di massa originale del veicolo.
• Prima di ricollegare la batteria accertarsi che il positivo e il negativo del sistema di allarme
siano stati collegati.
• Tutti i cavi collegati a positivo devono essere protetti da un fusibile opportunamente
dimensionato e posto vicino al punto di collegamento a positivo (vedi schema principale).
FITTING INSTRUCTION GLOBE3100
22
FACTORY SET-UP
1 NOT USED
--
3 FIXED MONOTONAL SIREN
4 ALTERNATING MONOTONAL SIREN
5 BITONAL SIREN
6 SWEEP SIREN TYPE
activated
activated
activated
activated
deactivated
deactivated
deactivated
deactivated
horn siren
1 NOT USED
2 NOT USED
1 NOT USED
2 ALARM EMISSION DEVICE
-
horn
-
siren
KITKIT
System with siren
3
HORN ALARM EMISSION MODE
continous
intermittent
System without siren
Slow flashing
Quick flashing
Slow flashing
Quick flashing
SIRENS TABLE
Quick flashing
Slow flashing

MANUALE INSTALLAZIONE GLOBE3100
8
Alcune caratteristiche di funzionamento di questo allarme sono programmabili.
Abbiamosuddivisolefunzioniprogrammabilinelleseguenti tabelle: buzzer,funzionibase,funzioniavanzate,
sirene.Lostesso criteriodisuddivisionedelle funzionièstatoutilizzato nelmanualeutente.
Regolazionedelvolumedelbuzzer
Per regolare il volume del buzzer è necessario entrare in programmazione: il sistema deve
essere disinserito, la porta ed il cofano devono essere aperti e il quadro deve essere acceso
(+15 presente). Mantenete premuto il tasto ‘A’ del radiocomando. Se tutte le condizioni sono
verificate il LED del pannello di emergenza si accende e dopo 3 s. circa il sistema risponderà
con un lampeggio delle frecce per segnalarVi che siete entrati in programmazione nella
tabella buzzer. Premendo il tasto ‘A’ del radiocomando il volume del buzzer aumenta, premendo
il tasto ‘B’ diminuisce.
Chiudendo il cofano si esce dalla programmazione.
COMEPROGRAMMAREILSISTEMA
Per entrare in programmazione è necessario che il sistema sia disinserito, che la porta ed il
cofano siano aperti e che il quadro sia acceso (+15 presente). Mantenete premuto il tasto ‘A’
del radiocomando. Se tutte le condizioni sono verificate il LED del pannello di emergenza si
accende e dopo 3 s. circa il sistema risponderà con un lampeggio delle frecce per segnalarVi
che siete entrati in programmazione nella tabella buzzer (regolazione volume buzzer). Premete
il tasto ‘A’ del radiocomando per alzare il volume, premete il tasto ‘B’ del radiocomando per
diminuire il volume.
Per passare alla tabella successiva ruotate la chiave quadro in posizione OFF e poi ON.
Il sistema risponderà con due lampeggi delle frecce per segnalarVi che siete nella tabella funzioni
base; questa segnalazione verrà emessa ogni 10 s. circa per rammentarVi il numero di
pagina in cui siete posizionati.
Per passare alle funzioni avanzate ruotate la chiave quadro in posizione OFF e poi ON. Il sistema
conferma sempre il cambio di tabella tramite il blinker, che lampeggerà tre volte.
Con quattro lampeggi indicherà che siete nella tabella sirene.
Comeattivare/disattivareunafunzione
Dopo essere entrati nelle tabelle funzioni base o funzioni avanzate, premete il tasto ‘A’ del
radiocomandoe posizionatevi sul numerodi linea corrispondentealla funzione chevolete attivare/
disattivare.Il lampeggio veloceindicherà che lafunzione è disattiva,il lampeggio lentoche èattiva,
il numero di lampeggi corrisponde al numero di riga della tabella funzioni che avete selezionato.
Per attivare/disattivare una funzione premete il tasto ‘B’ del radiocomando.
Nella stessa pagina possono essere attivate più funzioni contemporaneamente. L’attivazione
di una funzione non disattiva automaticamente le altre.
Chiudendo il cofano il sistema segnala con un lampeggio di 3 s. delle frecce che siete usciti
dalla procedura di programmazione.
Fate riferimento a pag. 9 dove troverete una guida rapida per la programmazione.
GLOBE 3100 FITTING INSTRUCTION 21
1 IMMOBILISER AUTO-REARM
2 ALARM AUTO-REARM
3 ALARM AUTO-REARM WITH DOOR LOCKING
4 AUTOLOCK - AUTOMATIC DOORS LOCKING
5 AUTOLOCK - AUTOMATIC DOORS LOCKING SELECTION MODE
6 AUTOMATIC ANTI HI-JACK
7 VOLUNTARY ANTI HI-JACK
8
ANTI HI-JACK IMMOBILISER CONTROLLED BY MOVEMENT SENSOR
1 CENTRAL DOOR LOCKING TIME SELECTION 1 See diagrams
3 CONTROLLED WINDOWS LIFT (CONFORT)
4 SIGNAL OF OPENED DOORS/BONNET/BOOT
5 ARM/DISARM BLINKER
6 AUTOMATIC ARMING
7 IMMOBILISER AUTOMATIC ARMING
8 IMMOBILISER ALARM
BUZZER VOLUME
2 CENTRAL DOOR LOCKING TIME SELECTION 2 See diagrams
deactivated
deactivated
deactivated
activated
activated
activated
deactivated
deactivated
deactivated
activated
activated
activated
activated
time
activated
activated
activated
deactivated
speed
deactivated
deactivated
deactivated
deactivated
deactivated
deactivated
Vol + Vol -
activated
activated
activated
BUZZER TABLE
deactivated
deactivated
activated
activated
BASIC FUNCTIONS TABLE
ADVANCED FUNCTIONS TABLE
FACTORY SET-UP
Slow flashing
Quick flashing

GLOBE3100 MANUALE INSTALLAZIONE 9
A
A
ON
ON
OFF
OFF
IGN +15
ALLARME
DISINSERITO
PER ENTRARE IN PROGRAMMAZIONE
A
D
OK
PER CAMBIARE TABELLA
ON
ON
OFF
OFF
PER CAMBIARE LINEA
PER USCIRE
PER ATTIVARE / DISATTIVARE UNA FUNZIONE
A
A
3"
EF
B
B
C
B
FITTING INSTRUCTION GLOBE3100
20
A
A
A
A
3"
B
B
ON
ON
OFF
OFF
IGN +15
ALARM
DISARMED
HOW TO START PROGRAMMING
C
B
A
D
OK
HOW TO CHANGE TABLE
ON
ON
OFF
OFF
HOW TO CHANGE LINE
HOW TO GO OUT
HOW TO ACTIVATE/DEACTIVATE A FUNCTION
EF

MANUALE INSTALLAZIONE GLOBE3100
10
1 ANTIDISTRAZIONE IMMOBILIZZATORE
2 ANTIDISTRAZIONE ALLARME
3 CHIUSURA PORTE DA ANTIDISTRAZIONE ALLARME
4 AUTOLOCK - BLOCCO AUTOMATICO PORTE
5 AUTOLOCK - SELEZIONE MODALITA' BLOCCO AUTOMATICO PORTE
6 ANTIRAPINA AUTOMATICA
7 ANTIRAPINA VOLONTARIA
8 BLOCCO MOTORE ANTIRAPINA CONTROLLATO DA SENSORE DI MOVIMENTO
1 TEMPO CHIUSURE CENTRALIZZATE SELEZIONE 1 Vedi schemi
3 CHIUSURA VETRI CONFORT CONTROLLATA
4 SEGNALAZIONE PORTE / COFANO / BAULE APERTI
5 BLINKER INSERIMENTO / DISINSERIMENTO
6 INSERIMENTO AUTOMATICO ALLARME
7 INSERIMENTO AUTOMATICO ANTIAVVIAMENTO
8 ALLARME ANTIAVVIAMENTO
VOLUME BUZZER
2 TEMPO CHIUSURE CENTRALIZZATE SELEZIONE 2 Vedi schemi
disattiva
disattiva
disattiva
attiva
attiva
attiva
disattiva
disattiva
disattiva
attiva
attiva
attiva
attiva
tempo
attiva
attiva
attiva
disattiva
velocità
disattiva
disattiva
disattiva
disattiva
disattiva
disattiva
Vol + Vol -
attiva
attiva
attiva
TABELLA BUZZER
disattiva
disattiva
attiva
attiva
TABELLA FUNZIONI BASE
TABELLA FUNZIONI AVANZATE
PROGRAMMAZIONE DI FABBRICA
Lampeggio lungo
Lampeggio corto
GLOBE 3100 FITTING INSTRUCTION 19
PROGRAMMINGTHESYSTEM
Many functions of this alarm are programmable. The programmable functions are divided in
the following tables: buzzer, basic functions, advanced functions and sirens. Refer to the
user manual for their working description.
Buzzer volume adjustment
To adjust the buzzer volume enter in the programming procedure: disarm the system, open
a door and the bonnet and turn the ignition key ON.
Keep pressed button “A” of the remote control. The turn indicators will come on for 2 s and
the LED will blink indicating that you have entered the programming procedure (buzzer
table).
Pressing button “A” the buzzer volume increases, pressing button “B” it decreases.
To exit the procedure just close the bonnet.
This product is reset to comply with EC Directives for alarm systems. The buzzer
function may only be activated in non EC or the Homologation will be invalidated.
How to program the system
Disarm the system, open a door and the bonnet and turn the ignition key ON.
Keep pressed button “A” of the remote control. The turn indicators will come on for 2 s and
the LED will blink indicating that you have entered the programming procedure (buzzer
table).
Pressing button “A” the buzzer volume increases, pressing button “B” it decreases.
Turn the ignition key OFF and then ON to go to the next table. The turn indicators will flash
twice to indicate that you are in the basic functions table. This signal is repeated every 10
s to indicate which table you are in. Turn again the ignition key OFF and then ON to go to the
advanced functions table. The system will confirm the new table with 3 turn indicator
flashes. 4 flashes will indicate that you are in sirene table.
How to activate/deactivate a function
Press button “A” of the radio control to change from one line of the same table to the next
until you reach the number of LED blink corresponding to the required line.
Press button “B” of the radio control to active the function. The blinks will become slow to
indicate that the chooser function has been activated.
More than one functions can be activated in the same table.
The activation of a function will not automatically deactivate the others.
To exit the procedure just close the bonnet.
As a “programming quick reference” please refer to page 20.

GLOBE3100 MANUALE INSTALLAZIONE 11
PROGRAMMAZIONE DI FABBRICA
1 NON USARE
--
3 SIRENA MONOTONALE FISSA
4 SIRENA MONOTONALE ALTERNATA
5 SIRENA BITONALE
6 SIRENA TIPO SWEEP
attiva
attiva
attiva
attiva
disattiva
disattiva
disattiva
disattiva
clacson sirena
1 NON USARE
2 NON USARE
1 NON USARE
2 DISPOSITIVO EMISSIONE ALLARME
-
clacson
-
sirena
KITKIT
Sistema con sirena
Lampeggio corto
Lampeggio lungo
3 MODALITA' EMISSIONE ALLARME CLACSON
continua
alternata
Sistema senza sirena
Lampeggio lungo
Lampeggio corto
Lampeggio lungo
Lampeggio corto
TABELLA SIRENE
FITTING INSTRUCTION GLOBE3100
18
Bonnet switch
The bonnet switch must be installed to facilitate programming of the alarm and of the radio
control auto-learning. Check that the switch is depressed by at least 5 mm. when the bonnet
is closed. Ensure that the switch is not acting against sound proofing as these materials
could deform over time.
Antenna
The position of the antenna is of fundamental importance to the operation of the radio
controls.
The wire must not be cut, wound, connected to other wires or to the bodywork and must be
kept separate from the wiring harness. Position the antenna at least 20 mm. far from metallic
parts.
Emergency Button Panel / LED
Install on the dashboard in an accessable position. The LED should be visable from outside
the vehicle. In addition to its deterrent function, the panel (LED + push button) is used for
programming and for emergency override.
ELECTRICALCONNECTIONS
ATTENTION!
Disconnect the negative terminal from the battery before starting the installation
of the system. This system is compatible with 12 Volt negative ground vehicles
Refer to the enclosed wiring diagrams, and take note of the following:
• Route the alarm wires along side the original vehicle harness.
• The system ground must be connected to an original vehicle ground point.
• Connect the alarm unit negative and positive feed before reconnecting the car battery.
• The positive supply to the system, must be protected by an adequate fuse located close
to the point of connection (see main diagram).

MANUALE INSTALLAZIONE GLOBE3100
12
PROCEDURADIABBINAMENTONUOVIRADIOCOMANDI(AUTOAPPRENDIMENTO)
In caso di smarrimento o di malfunzionamento dei radiocomandi è possibile sostituirli in
condizioni di sicurezza poichè tale operazione è permessa solo in particolari circostanze.
Se siete in possesso di almeno uno dei radiocomandi e questo funziona correttamente,
procedere come segue:
1.1.
1.1.
1. Disinserire il sistema
2.2.
2.2.
2. Aprire una porta ed il cofano
3.3.
3.3.
3. Accendere il quadro
4.4.
4.4.
4. Tenere premuto il tasto ‘A’ del radiocomando fino a che non si ottiene un lampeggio degli
indicatori di direzione
5.5.
5.5.
5. Digitare il PIN code
6.6.
6.6.
6. Il sistema conferma che si è entrati in procedura di autoapprendimento con un altro
lampeggio lungo degli indicatori di direzione e con l’accensione del LED del sistema in
modo fisso.
7.7.
7.7.
7. Premere entrambi i tasti del nuovo radiocomando fino a quando il led di quest’ultimo
diventa da lampeggiante a spento.
8.8.
8.8.
8. Rilasciare i tasti e verificare che il led del radiocomando si accenda in modo fisso
9.9.
9.9.
9. Premere il tasto ‘A’ del radiocomando, verificare che il led del radiocomando lampeggi e che
il led del pannello di emergenza si spenga per circa 1 s.; anche gli indicatori di direzione
emetterannoun brevelampeggio perconfermarel’avvenutamemorizzazionedel radiocomando.
10.10.
10.10.
10. Ripetere i passi 7-8-9 per tutti i radiocomandi che si vogliono abbinare (anche il
radiocomando che era già funzionante dovrà essere rimemorizzato)
11.11.
11.11.
11. Se non si esegue nessuna operazione per un tempo maggiore di 30 s. il sistema esce
automaticamente dalla modalità di autoapprendimento segnalandone l’abbandono con un
lampeggio lungo degli indicatori di direzione.
12.12.
12.12.
12. Per uscire volontariamente dalla procedura è necessario spegnere il quadro. Tale operazione
può essere effettuata in qualsiasi momento.
ATTENZIONE!ATTENZIONE!
ATTENZIONE!ATTENZIONE!
ATTENZIONE!
Nel caso siano stati smarriti entrambi i radiocomandi procedere come segue:
A.A.
A.A.
A. Disinserire il sistema inserendo il PIN code
B.B.
B.B.
B. Togliere alimentazione al sistema (scollegare il connettore dalla centralina)
C.C.
C.C.
C. Aprire una porta ed il cofano.
D.D.
D.D.
D. Accendere il quadro
E.E.
E.E.
E. Ricollegarel’alimentazione.
F.F.
F.F.
F. Digitare il PIN code
G.G.
G.G.
G. Con un lampeggio lungo il led conferma che il codice inserito è corretto.
H.H.
H.H.
H. Dopo circa 5 s. il led inizia a lampeggiare segnalando che si è entrati nella procedura di
autoapprendimento.
I.I.
I.I.
I. Ripetere i passi 7-8-9 della procedura di abbinamento nuovi radiocomandi per tutti i
trasmettitori da abbinare.
Nota:Nota:
Nota:Nota:
Nota: Quando si abbina un nuovo radiocomando il sistema mette automaticamente fuori uso
quelli precedentemente utilizzati. Per mantenerne la funzionalità dovranno essere abbinati
nuovamente. Il sistema può memorizzare fino ad un massimo di 4 radiocomandi.
GLOBE 3100 FITTING INSTRUCTION 17
1
2
3
4
Ø 3 mm.
ATTENTION!
This product is preset to comply with EC Directives for alarm systems. The buzzer function
may only be activated in non EC or the homologation will be invalidated.
Disconnect the negative terminal from the battery before starting the installation
of the system.
This system is compatible with 12 volt negative ground vehicles.
POSITIONINGTHE COMPONENTSOF THESYSTEM
All the parts of the system should be installed in hidden locations which are difficult to
access and away from heat sources.
Alarm unit
Fit in the passenger compartment using the adhesive pad provided. The alarm unit main
connector should exit downwards.
Siren with back up battery
Locate in the engine bay
taking care to position it
as indicated.
Siren without back up
battery
Fix in the engine compartment,
using the screws provided, to a
metal surface to increase heat
dissipation.
Volumetric ultrasonic sensor (if applicable)
Fit the transducers at the top of the ‘A’ pillars each side of the windscreen, taking care that
they are not covered when the sunvisors are down. If the car is equipped with sliding
sunroof, do not fit the transducers on the dashboard. Check the right position of the
transducers during the functional test of the system. No adjustment is required for the
volumetric ultrasonic sensor.
Glass break sensor (if applicable)
Fit the microphone in a central position in the passenger compartment. Eg. in the dashboard,
pointing towards the rear window. This position achieves uniform sensitivity. The sensor
can be used in conjunction with the ultrasonic volumetric sensor. Drawings in the central
part of this manual show different connection methods.
NO
O.K.

GLOBE3100 MANUALE INSTALLAZIONE 13
COLLEGAMENTODELSENSOREDIMOVIMENTO/SEGNALEDITACHIGRAFO
Il segnale di tachigrafo è un segnale la cui frequenza è proporzionale alla velocità di marcia
(normalmente segnale con forma rettangolare e f max = 4 KHz)
Se la funzione attivata lo richiede il segnale di tachigrafo deve essere collegato al filo ROSA/
NERO dell’allarme. In alcune vetture il segnale deve essere prelevato direttamente dallo
strumento combinato. Il segnale non deve essere prelevato da apparecchi di comando del
sistema ABS o da circuiti di controllo affinchè non vengano pregiudicate la funzionalità e la
sicurezza del veicolo.
COLLEGAMENTO DELLE CHIUSURE CENTRALIZZATE
Gliallarmi sonoforniti condiverse configurazionidi uscitaperilcontrollodelle chiusurecentralizzate:
2 fili, 3 fili, 6 fili. Gli schemi applicativi sono riportati nelle pagine centrali.
FITTING INSTRUCTION GLOBE3100
16
• Self-learning radio controls.
• Emergency override (PIN code).
• Battery back up protection.
• Garage function.
Basic functions list (programmable)
Thesearethefunctionsthatrequiretobeprogrammedasperthemodelofthevehicleandofthe
requiredfunctionsof thealarm.Pleaserefertothebasicfunctionsoftheprogrammingtables.
• Central door locking pulse width selection.
• Controlled windows lift (comfort).
• Warning opened doors/bonnet/boot.
• Arm/disarm blinker.
• Automatic arming.
• Immobiliserautomatic arming.
• Immobiliseralarm.
Advanced functions list (programmable)
Theseareparticularfunctionsthatcanbeprogrammedaspertherequiredmodalitesoffunction
ofthealarm.Pleaserefertotheadvancedfunctionsoftheprogrammingtables.
• Immobiliserauto-rearm.
• Alarm auto-rearm.
• Auto-rearm with doors locking.
• Autolock - automatic doors locking.
• Autolock - automatic doors locking mode.
• Automatic anti hi-jack.
• Voluntary anti hi-jack.
• Anti hi-jack immobilisation controlled by movement sensor (VSS input).
Horn/siren functions (Only for 3193/3191/3192)
It is possible to select an intermittent alarm horn output or the following siren sounds.
- Fixed monotonal siren.
- Intermittent monotonal siren.
- Bitonal siren.
- Sweep siren type.
Please refer to the sirens table of the programming tables.
RADIOCONTROLSFUNCTIONS
Button A Arm/disarm the alarm and the immobiliser, allows entry into programming,
selects the line and increases the volume of the buzzer in the
programming tables.
Button B Panic, arm/disarmvoluntaryantihi-jackmode,activates thegaragefunction,
excluses the volumetric and additional sensor protection, activates/
deactivates the buzzer and reduce its volume in the programming tables.

MANUALE INSTALLAZIONE GLOBE3100
14
mod. 7777
A
B
Inserire lallarme premendo il
pulsante 'A' del radiocomando.
Verificare che nellabitacolo non vi
sia alcun oggetto in movimento.
Chiudere porte, cofano e bagagliaio
tenendo abbassati di 10 centimetri
i due vetri dello stesso lato.
Introdurre la mano e muoverla
allaltezza del poggiatesta del
sedile anteriore.
Se il LED si spegne ad ogni
movimento rilevato vuol dire che
il sensore sta funzionando
correttamente.
Inserire lallarme premendo il
pulsante 'A' e con il palmo della
mano dare dei colpi su ogni vetro.
Il LED deve restare acceso fisso.
Disinserire lallarme premendo il
pulsante 'A' del radiocomando e
chiudere i vetri.
Attendere 40 s..
Aprire una porta con la chiave.
La sirena suona e gli indicatori di
direzione lampeggiano.
Chiudere la porta.
Spegnere la sirena con il pulsante
"A" del radiocomando.
Ripetere la prova per le altre porte
collegate, il cofano ed il bagagliaio.
Inserire lallarme premendo il
pulsante 'A' del radiocomando. Gli
indicatori di direzione lampeggiano
due volte, mentre il buzzer genera
due segnali acustici (se attivato).
Le porte si bloccano.
Il LED si accende.
Disinserire lallarme premendo il
pulsante 'A' del radiocomando.
Gli indicatori di direzione
lampeggiano 4 volte (memoria di
allarme). Le porte si sbloccano e il
led lampeggia indicando la causa
dell'allarme.
Effettuare i controlli nella sequenza indicata.
Le operazioni di prova devono essere
effettuate entro i 40 s. di inibizione. Scaduto
questo tempo si originerà una situazione
di allarme (sirena e blinker).
CONTROLLO FUNZIONALE DEL
SENSORE AD ULTRASUONI
(SE PREVISTO)
Effettuare i controlli nella sequenza indicata.
CONTROLLO FUNZIONALE
PROTEZIONE PERIMETRICA
mod. 7779
A
B
GLOBE 3100 FITTING INSTRUCTION 15
INTRODUCTION
This manual contains all the information necessary to install the alarm system and to set it
up as required by the customer and/or by the local / insurance directive. Refer to the user
manual for a description of each function. You should indicate the program you have set in
the user manual. Each function is described in the user manual, while in this manual you will
find some suggestions to follow during the installation.
IMPORTANT
1- The Cobra 3198 alarm system MUST be fitted with a previously installed Category 2
M.I.R.R.C. listed immobiliser to obtain Category 1 status for the vehicles security
systems. If there is no Category 2 Thatcham listed immobiliser fitted along with
associated VSIB installation certificate, Category 1 status cannot be claimed on
fitment of alarm.
2- The Cobra 3198 is a stand-alone system and MUST NOT be connected in any way
to an existing immobiliser.
3- The Cobra 3198 must not take it’s power supply from the same circuit as the existing
immobiliser and not interfere in any way with the immobiliser cut circuitry.
4- Where the existing immobiliser is connected to visual indicators Cobra 3198 MUST
NOT be connected to visual indicators at all. Therefore the 2 Yellow wires are not
used and must be insulated.
Standard functions list (not programmable)
Here following are listed the main functions of the alarm. It is not possible to
activate / deactivate and personalize them.
• Remote arm and disarm via dynamic code radio control.
• Volumetric protection of the passenger compartment by self adjusting ultrasonic sensor.
• Perimetric protection. An alarm condition is triggered if a door, boot or bonnet is opened.
There is a 40 s set up delay, after arming the system, before the sensors are active.
• Hotwire protection. When armed, the immobiliser is active and any attempt at starting
triggers an alarm condition.
• When the alarm is triggered the electronic siren sounds for 30 s at more than 115 dB (@
1m) and the turn indicators flash.
• Electric central door locking and boot remote control.
• Alarm status LED which displays also alarm status history.
• Signal of low radio control battery.
• Safety circuit that ensures that the alarm cannot be armed while the vehicle’s engine is
running.
• Panicalarm.
• Volumetric ultrasonic sensor and/or external sensor excludable by remote control.
Table of contents
Other Cobra Car Alarm manuals

Cobra
Cobra 1046 User manual

Cobra
Cobra 8185 User manual

Cobra
Cobra G100 User manual

Cobra
Cobra GLOBE 4800 CAN User manual

Cobra
Cobra 1046 User manual

Cobra
Cobra 4625 User manual

Cobra
Cobra SPYBALL 6808-9 User manual

Cobra
Cobra G100 User manual

Cobra
Cobra 8165 User manual

Cobra
Cobra Bridge compact alarm User manual

Cobra
Cobra Connex ICD31 User manual

Cobra
Cobra AK4169 User manual

Cobra
Cobra Connex Guardian 222X User manual

Cobra
Cobra 3800 GLOBE User manual

Cobra
Cobra 4625 User manual

Cobra
Cobra 4600 CAN/PLIP User manual

Cobra
Cobra G100 User manual

Cobra
Cobra GLOBE 3900 Installation instructions

Cobra
Cobra BRIDGE User manual

Cobra
Cobra 4600 CAN User manual