Code CR1000 User manual

USER MANUAL
NORTH AMERICA: ENGLISH
MANUAL VERSION 06
RELEASE DATE: JUNE 2014
Configuration Guidewww.codecorp.com YouTube.com/codecorporation
CR1000

2
C005905_06_CR1000_UserManual
Statement of Agency Compliance
Code Reader™1000 User Manual
The Code Reader™ 1000 (CR1000) has been tested for compliance with FCC regulations and was found to be compliant
with all applicable FCC Rules and Regulations.
IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements, this device must not be co-located or
operate in conjunction with any other antenna or transmitter
CAUTION: Changes or modications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
The CR1000 has been tested for compliance to CE standards and guidelines and was found to conform to applicable CE
standards, specically the EMC requirements EN 55024, ESD EN 61000-4-2, Radiated RF Immunity
EN 61000-4-3, ENV 50204, EFT EN 61000-4-4, Conducted RF Immunity EN 61000-4-6, EN 55022, Class B Radiated
Emissions, and Class B Conducted Emissions.
Code voids product warranty if the hard case has been opened or tampered with in any way.
In addition, a CB Test Certicate has been issued by the National Certication Board (NCB) indicating CR1000 meets all
safety and quality standards in accordance to IEC 60950-1:2001, First Edition.
Copyright © 2014 Code Corporation.
All Rights Reserved.
The software described in this manual may only be used in accordance with the terms of its license agreement.
No part of this publication may be reproduced in any form or by any means without written permission from Code Corporation. This includes
electronic or mechanical means such as photocopying or recording in information storage and retrieval systems.
NO WARRANTY. This technical documentation is provided AS-IS. Further, the documentation does not represent a commitment on the part
of Code Corporation. Code Corporation does not warrant that it is accurate, complete or error free. Any use of the technical documentation
is at the risk of the user. Code Corporation reserves the right to make changes in specications and other information contained in this
document without prior notice, and the reader should in all cases consult Code Corporation to determine whether any such changes
have been made. Code Corporation shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or
consequential damages resulting from the furnishing, performance, or use of this material. Code Corporation does not assume any product
liability arising out of or in connection with the application or use of any product or application described herein.
NO LICENSE. No license is granted, either by implication, estoppel, or otherwise under any intellectual property rights of Code Corporation.
Any use of hardware, software and/or technology of Code Corporation is governed by its own agreement.
The following are trademarks or registered trademarks of Code Corporation:
CodeXML®, Maker, QuickMaker, CodeXML® Maker, CodeXML® Maker Pro, CodeXML® Router, CodeXML® Client SDK, CodeXML®Filter,
HyperPage, CodeTrack, GoCard, GoWeb, ShortCode, GoCode®, Code Router, QuickConnect Codes, Rule Runner®, Cortex®, CortexRM,
CortexMobile, Code, Code Reader, CortexAG, CortexStudio, CortexTools, Afnity®, and CortexDecoder.
All other product names mentioned in this manual may be trademarks of their respective companies and are hereby acknowledged.
The software and/or products of Code Corporation include inventions that are patented or that are the subject of patents pending. U.S.
Patents: 6997387, 6957769, 7428981, 6619547, 6736320, 7392933, 7014113, 7240831, 7353999, 7519239, 7204417,
6942152, 7070091, 7097099, 7621453, 8001550, 8011584
The Code Reader software uses the Mozilla SpiderMonkey JavaScript engine, which is distributed under the terms of the Mozilla Public
License Version 1.1.
The Code Reader software is based in part on the work of the Independent JPEG Group.
Code Corporation, 12393 S. Gateway Park Place, Ste. 600, Draper, Utah 84020
www.codecorp.com

3
C005905_06_CR1000_UserManual
Table of Contents
1.0 - Included Items ........................................................................................... 4
2.0 - Attaching and Detaching a Cable.................................................................. 5
3.0 - Set Up....................................................................................................... 5
4.0 - Using a CR1000 Out of a Stand................................................................... 6
5.0 - Using a CR1000 In a Stand ........................................................................ 6
6.0 - Reading Ranges.......................................................................................... 6
7.0 - Reader Feedback ........................................................................................ 7
8.0 - Symbologies Defaulted On ........................................................................... 7
9.0 - Symbologies Defaulted Off........................................................................... 7
10.0 - Reader ID & Firmware Version.................................................................... 8
11.0 - CR1000 Hole Mounting Pattern ................................................................. 8
12.0 - CR1000 Overall Dimensions ...................................................................... 9
13.0 - USB Cable Example with Pinouts ............................................................... 9
14.0 - RS232 Cable Example with Pinouts............................................................ 9
15.0 - Reader Pinouts....................................................................................... 10
16.0 - CR1000 Maintenance ............................................................................. 10
17.0 - Warranty ................................................................................................ 11

4
C005905_06_CR1000_UserManual
1.0 - Included if Ordered
CR1000
(Model #: CR1011 or CR1021)
USB 2.0 Cable RS232 Cable 5VDC
Power Supply

5
C005905_06_CR1000_UserManual
2.0 - Attaching and Detaching a Cable
3.0 - Set Up
1
Plug in
Wait 10 seconds
LED will ash
Reader will beep
2
3
4
USB
RS232
10 Sec.
2x
1

6
C005905_06_CR1000_UserManual
6.0 - Reading Ranges
Note: Working ranges are a combination of both the wide and high density elds. All samples were high quality barcodes and were read along a
physical center line at a 10° angle. Default AGC settings were used. Accuracy= +/- 10%.
4.0 - Using a CR1000
Out of a Stand
5.0 - Using a CR1000
In a Stand
CR1000 Performance
Test Barcode Min Inches (mm) Max Inches (mm)
3 mil Code 39 3.1” (80 mm) 4.0” (102 mm)
7.5 mil Code 39 1.3” (33 mm) 7.2” (182 mm)
10.5 mil GS1 DataBar 0.8” (20 mm) 8.7” (220 mm)
13 mil UPC 1.1” (28 mm) 11.0” (280 mm)
5 mil DM 1.7” (43 mm) 4.5” (115 mm)
6.3 mil DM 1.3” (33 mm) 5.9” (150 mm)
10 mil DM 0.8” (20 mm) 7.1” (180 mm)
20.8 mil DM 1.1” (28 mm) 13.5” (343 mm)
10 cm
10 cm

7
C005905_06_CR1000_UserManual
7.0 - Reader Feedback
8.0 - Symbologies Defaulted On 9.0 - Symbologies Defaulted Off
Scenario Top LED Light Sound
CR1000 Successfully Powers Up Green LED Flashes 1 beep
CR1000 Successfully Enumerates with Host (via cable) Once Enumerated, the Green LED turns Off 1 beep
Attempting to Decode Green LED Light is Off None
Successful Decode and Data Transfer Green LED Flashes 1 beep
Conguration Barcode Successfully Decoded and Processed Green LED Flashes 2 beeps
Conguration Barcode Successfully Decoded but Wasn’t
Successfully Processed
Green LED Flashes 4 beeps
The following are symbologies that have a default of ON.
To turn symbologies on or off, scan the symbology barcodes
located in the CR1000 Conguration Guide located on our
website at www.codecorp.com/les.php.
Aztec
Codabar
Code 39
Code 93
Code 128
Data Matrix
Data Matrix Inverse
Data Matrix Rectangle
All GS1 DataBar
Interleaved 2 of 5
PDF417
QR Code
UPC/EAN/UPC-E
Micro PDF417
MSI Plessey
NEC 2 of 5
Pharmacode
Plessey
Standard 2 of 5
Telepen
Trioptic
Postal Codes
Code barcode readers can read a number of barcode
symbologies that are not enabled by default. To turn
symbologies on or off, scan the symbology barcodes located in
the CR1000 Conguration Guide located on our website at
www.codecorp.com/les.php.
Codablock F
Code 11
Code 32
Composite
Han Xin Code
Hong Kong 2 of 5
IATA 2 of 5
Maxicode
Matrix 2 of 5

8
C005905_06_CR1000_UserManual
11.0 - CR1000 Hole Mounting Pattern
10.0 - Reader ID and Firmware Version
A text string indicating the rmware version and CR1000 ID number will be displayed.
example: Xap/i06760456none0020094903A06000000700070016006200 02cd(13.2.18) (see below):
To nd out the Reader ID and Firmware version, open a text editor program
(i.e., Notepad, Microsoft Word, etc.) and read the Reader ID and Firmware
conguration barcode.
Reader ID and Firmware
Note: Code will periodically release new rmware for CR1000 readers. For information on latest rmware visit our website at
www.codecorp.com/codesupport.php.
Display
type
Flash file system
version number
Hardware
revision
Hardware type
identifier
Boot
application
version
Operating
system kernel
version
Root file
system
version
Decoder version
ASCII TAB
character
Xap/i08080808none 0020094903A0600000 07000700160062 0002 cd(13.2.18)
○
Firmware
version
Boot firmware
version
Radio firmware
version
Reader serial
number (ten digits)
Current
execution state
String
output
OEM
identifier
○
NOTE 1:
Locating holes are 2 mm in
diameter, hole depth is 1.5 mm.
NOTE 2:
Mounting inserts are M3-.5 internal
thread, 3.8 mm length.
10.36 mm
15.53 mm
34.08 mm
31.12 mm
30.20 mm
27.01 mm

9
C005905_06_CR1000_UserManual
12.0 - CR1000 Overall Dimensions
13.0 - USB Cable Example with Pinouts
14.0 - RS232 Cable Example with Pinouts
NOTES:
1. Part to be ROHS and Reach compliant.
2. Maximum Voltage Tolerance = 5V +/- 10%.
3. Caution: Exceeding the maximum voltage will void
manufacturer warranty.
CONNECTOR A CONNECTOR B
NOTES:
1. Part to be ROHS and Reach compliant.
2. Maximum Voltage Tolerance = 5V +/- 10%.
3. Caution: Exceeding the maximum voltage will void
manufacturer warranty.
CONNECTOR A NAME WIRE COLOR CONNECTOR B
1VIN 24A WG RED 1
2DM 28A WG WHITE 2
3 DP 28A WG GREEN 3
4 GND 24A WG BLACK 10
SHELL -SHIELD BARE SHELL
CONN A NAME WIRE COLOR CONN B WIRE COLOR CONN C
1VIN 24A WG RED 124A WG RED TIP
4TX 28A WG BROWN 2
5RTS 28A WG ORANGE 8
6RX 28A WG YELLOW 3
7 CTS 28A WG GREEN 7
10 GND 24A WG BLACK 5 24A WG BLACK RING
SHIELD -SHIELD SHIELD
2.6"
(67 mm)
1.7"
(30 mm)
2.2"
(52 mm)

10
C005905_06_CR1000_UserManual
15.0 - Reader Pinouts
The connector on the CR1000 is an RJ-50
(10P-10C). The pinouts are as follows: Pin 1 +VIN (5v)
Pin 2 USB_DM
Pin 3 USB_DP
Pin 4 RS232 TX (output from reader)
Pin 5 RS232 RTS (output from reader)
Pin 6 RS232 RX (input to reader)
Pin 7 RS232 CTS (input to reader)
Pin 8 External Trigger (active low input to reader)
Pin 9 N/C
Pin 10 Ground
16.0 - CR1000 Maintenance
The CR1000 device needs only a minimum of maintenance to operate. A few tips are given below for maintenance suggestions.
Cleaning the CR1000 Window
CR1000 window should be clean to allow the best performance of the device. The window is the clear plastic piece inside the head of
the reader. Do not touch the window. Your CR1000 uses CMOS technology that is much like a digital camera. A dirty window may stop
the CR1000 from reading barcodes.
If the window becomes dirty, clean it with a soft, non-abrasive cloth or a facial tissue (no lotions or additives) that has been moistened
with water. A mild detergent may be used to clean the window, but the window should be wiped with a water moistened cloth or tissue
after using the detergent.
Technical Support and Returns
For returns or technical support call Code Technical Support at (801) 495-2200. For all returns Code will issue an RMA number which
must be placed on the packing slip when the reader is returned. Visit www.codecorp.com/codesupport.php for more information.

11
C005905_06_CR1000_UserManual *Warranty periods are North America specic.
17.0 - Warranty*
The CR1000 carries a standard two year limited warranty as described herein. Extended warranty periods may be available with a CodeOne Service
Plan. Stand and Cables have a 30 day warranty period.
Limited Warranty. Code warrants each Code product against defects in materials and workmanship under normal use for the Warranty Coverage Term
applicable to the product as described at www.codecorp.com/legal/warranty/term.php. If a hardware defect arises and a valid warranty claim is
received by Code during the Warranty Coverage Term, Code will either: i) repair a hardware defect at no charge, using new parts or parts equivalent
to new in performance and reliability; ii) replace the Code product with a product that is new or refurbished product with equivalent functionality
and performance, which may include replacing a product that is no longer available with a newer model product; or ii) in the case of failure with any
software, including embedded software included in any Code product, provide a patch, update, or other work around. All replaced products become the
property of Code. All warranty claims must be made using Code’s RMA process.
Exclusions. This warranty does not apply to: i) cosmetic damage, including but not limited to scratches, dents, and broken plastic; ii) damage resulting
from use with non-Code products or peripherals, including batteries, power supplies, cables, and docking station/cradles; iii) damage resulting from
accident, abuse, misuse, ood, re or other external causes, including damage caused by unusual physical or electrical stress, immersion in uids or
exposure to cleaning products not approved by Code, puncture, crushing, and incorrect voltage or polarity; iv) damage resulting from services performed
by anyone other than a Code authorized repair facility; v) any product that has been modied or altered; vi) any product on which the Code serial
number has been removed or defaced. If a Code Product is returned under a warranty claim and Code determines, in Code’s sole discretion, that the
warranty remedies do not apply, Code will contact Customer to arrange either: i) repair or replace the Product; or ii) return the Product to Customer, in
each case at Customer’s expense.
Non Warranty Repairs. Code warrants its repair/replacement services for ninety (90) days from the date of shipment of the repaired/replacement product
to the Customer. This warranty applies to repairs and replacements for: i) damage excluded from the limited warranty described above; and ii) Code
Products on which the limited warranty described above has expired (or will expire within such ninety (90) day warranty period). For repaired product
this warranty covers only the parts that were replaced during the repair and the labor associated with such parts.
No Extension of Term of Coverage. Product that is repaired or replaced, or for which a software patch, update, or other work around is provided, assumes
the remaining warranty of the original Code Product and does not extend the duration of the original warranty period.
Software and Data. Code is not responsible for backing up or restoring any of software, data, or conguration settings, or reinstalling any of the foregoing
on products repaired or replaced under this limited warranty.
Shipping and Turn Around Time. The estimated RMA turn-around time from receipt at Code’s facility to shipment of the repaired or replaced product
to Customer is ten (10) business days. An expedited turn-around time may apply to products covered under certain CodeOne Service Plans. Customer
is responsible for shipping and insurance charges for shipping Code Product to Code’s designated RMA facility and repaired or replaced product is
returned with shipping and insurance paid by Code. Customer is responsible for all applicable taxes, duties, and similar charges.
Transfer. If a customer sells a covered Code Product during the Warranty Coverage Term, then that coverage may be transferred to the new owner by
written notication from the original owner to Code Corporation at:
CodeOne Service Center
12393 South Gateway Park Place, Suite 600
Draper, UT 84020
Limitation on Liability. Code’s performance as described herein shall be Code’s entire liability, and the Customer’s sole remedy, resulting from any
defective Code product. Any claim that Code has failed to perform its warranty obligations as described herein must be made within six (6) months of
the alleged failure. Code’s maximum liability related to its performance, or failure to perform, as described herein shall be limited to the amount paid
by Customer for the Code product that is subject to the claim. In no event will either party be liable for any lost prots, lost savings, incidental damage,
or other economic consequential damages. This is true even if the other party is advised of the possibility of such damages.
EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THE LIMITED WARRANTIES DESCRIBE HEREIN REPRESENT THE ONLY
WARRANTIES CODE MAKES WITH RESPECT TO ANY PRODUCT. CODE DISCLAIMS ALL OTHER WARRANTIES, WHETHER EXPRESSED OR
IMPLIED, ORAL OR WRITTEN, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE AND NON-INFRINGEMENT.
THE REMEDIES DESCRIBED HEREIN REPRESENT CUSTOMER’S EXCLUSIVE REMEDY, AND CODE’S ENTIRE RESPONSIBILITY, RESULTING FROM
ANY DEFECTIVE CODE PRODUCT.
CODE SHALL NOT BE LIABLE TO CUSTOMER (OR TO ANY PERSON OR ENTITY CLAIMING THROUGH CUSTOMER) FOR LOST PROFITS, LOSS OF
DATA, DAMAGE TO ANY EQUIPMENT WITH WHICH THE CODE PRODUCT INTERFACES (INCLUDING ANY MOBILE TELEPHONE, PDA, OR OTHER
COMPUTING DEVICES), OR FOR ANY SPECIAL, INCIDENTAL, INDIRECT, CONSEQUENTIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR IN
ANY MANNER CONNECTED WITH THE PRODUCT, REGARDLESS OF THE FORM OF ACTION AND WHETHER OR NOT CODE HAS BEEN INFORMED
OF, OR OTHERWISE MIGHT HAVE ANTICIPATED, THE POSSIBILITY OF SUCH DAMAGES.
Other manuals for CR1000
4
This manual suits for next models
2
Table of contents
Other Code Barcode Reader manuals

Code
Code Reader 1200 Installation and operation manual

Code
Code CR1400 User manual

Code
Code 2600 Quick setup guide

Code
Code CR8200 User manual

Code
Code CR2 User manual

Code
Code Code Reader CR8000 Quick setup guide

Code
Code 2600 User manual

Code
Code 2600 Quick setup guide

Code
Code 2600 User manual

Code
Code CR1400 User manual

Code
Code CR950 User manual

Code
Code Reader 2500 CR2500) User manual

Code
Code CR3 User manual

Code
Code CR900FD User manual

Code
Code CR3 User manual

Code
Code CORTEXJPOS CR6000 User manual

Code
Code Reader 2300 User manual

Code
Code CR4405 User manual

Code
Code CR900FD User manual

Code
Code CORTEXJPOS CR5000 User manual