CommScope C9500 User manual

Model C9500
10G OLT
(Optical Line Terminal)

Model C9500 10G OLT

i
CommScope C9500 10G OLT Installation Guide
Preface
The CommScope C9500 10G OLT is a full-featured optical line terminal, designed for use in today’s high speed,
high demand passive optimal networks. This guide provides clear and easy-to-follow instructions on installing,
connecting and troubleshooting your CommScope C9500 10G OLT.
This Installation Guide has been written to help guide the installer:
become familiar with the features and components of the C9500 OLT
properly site and prepare the unit for a rack-mounted installation
understand the specific electrical and grounding requirements of the system
quickly identify the operating status of the C9500 OLT by referencing LED status lights
troubleshoot some of the most commonly occurring issues
This Installation Guide should be made available to all installers, system integrators and enterprise engineers who
are involved with the installation and commissioning of the PON network in which this OLT will be deployed.
Related documents
In addition, the manual set for this product also includes the following documents. Should you have questions
regarding the installation or use of the C95000, please consult these other documents before contacting your
CommScope representative.
NOTICE You can download or request the latest documents and information
on CommScope Inc. from the website http://www.CommScope.com
Manual
Contents
C9500 OLT User Guide Operating configuration for services.
System operation, administration and maintenance.
Troubleshooting.

ii
CommScope C9500 10G OLT Installation Guide
Symbols used in this guide
The Installation Guide uses the following icons and fonts to indicate special messages for the reader.
NOTE
Presents useful information related to Installation Guide contents, the references and data
related to the product’s use, etc.
CAUTION Describes situations where data loss and incorrect product operation may occur, and
provides proper actions to take in these situations.
WARNING Describes a situation where product damage and user injury may occur, and provides
proper actions to take in these situations.
WARNING Warning: optical terminal
Do not look at the optical terminal directly. It could cause serious damage to your eyes.
WARNING
Do not disassemble or assemble the product. The user must not remove or attach the
product cover or disassemble or assemble the product when the power is on. Doing so
may cause personal injury or property loss.
Document History
Version Issue Date Author Comments
1.0 07/09/13 Sam Choi Initial Release
2.0 17/09/ 14 Ben Bond

iii
CommScope C9500 10G OLT Installation Guide
Table of contents
Preface...................................................................................................i
Related documents..........................................................................................................i
Symbols used in this guide.............................................................................................ii
Document History................................................................................ii
Table of contents ................................................................................iii
List of Tables ...............................................................................................vi
List of Figures.............................................................................................vii
Introduction and System Overview.............................................................1
Main functions and features ...............................................................1
System components............................................................................2
Overview........................................................................ Error! Bookmark not defined.
C9500 Component Descriptions ....................................................................................4
Fan Ventilation................................................................................................................9
Power Supply ...............................................................................................................11
Ground Terminal...........................................................................................................12
Installation Preparation.....................................................................14
Notes to consider before installation ............................................................................14
Do not disassemble the product...................................................................................14
Installation site condition ..............................................................................................14
Satisfying operational environment conditions.............................................................15
Prevent static electricity................................................................................................15
Power precautions........................................................................................................15
Grounding.....................................................................................................................16
Lightning.......................................................................................................................16
Checking a rack before installation ..............................................................................16
Preventing overheating.................................................................................................17
Cleaning the product ....................................................................................................17
Other notes...................................................................................................................17
Checking the installation environment..........................................................................17
Working with Lasers .....................................................................................................18
Heat Dissipation ...........................................................................................................18

iv
CommScope C9500 10G OLT Installation Guide
Necessary Items for Installation.......................................................19
Package Contents..............................................................................20
Installation ..................................................................................................21
InstallationPlace................................................................................22
Mounting on Rack.........................................................................................................22
Grounding the OLTs............................................................................25
Grounding the OLT on the rack....................................................................................25
Bonding Network for Grounding ...................................................................................26
Installing a LINE Card ........................................................................30
Removing the LINE Card....................................................................32
Connector and Cable Connection .....................................................32
PONNetwork Configuration...............................................................33
ConnectingPower..............................................................................34
Connecting the Console Terminal.................................................................................35
Connecting the Management Port.....................................................36
OperationChecking ...........................................................................37
Checking the LEDs.......................................................................................................37
Checking Console.........................................................................................................38
Setting IPAddress ........................................................................................................38
Troubleshooting.........................................................................................40
TroubleshootingCases......................................................................41
FMU Change ................................................................................................................42
Removing a FMU..........................................................................................................43
Installing a FMU............................................................................................................43
Installing or Removing Dust Filter.................................................................................44
AppendixA. Product Specification...........................................................46
Appendix B. Connector and Cable Specification ....................................48
ConnectorsSpecification...................................................................49
RJ-45 Connector ..........................................................................................................49
LC Connector ...............................................................................................................50

v
CommScope C9500 10G OLT Installation Guide
SC Connector...............................................................................................................50
CablesSpecification ..........................................................................51
Optical Cable................................................................................................................51
Console Cable..............................................................................................................52

vi
CommScope C9500 10G OLT Installation Guide
List of Tables
Table 2 LED status description................................................................................6
Table 3 Heat Dissipation per Height ......................................................................18
Table 4 Package Contents.....................................................................................20
Table 5 FMU LED Status .......................................................................................42
Table 6 Specification ..............................................................................................46
Table 7 Pin Configuration of 10/100/1000Base-T Port...........................................49
Table 8 Pin Configuration of Console Port .............................................................50
Table 9 Console Cable Pin Signal..........................................................................52

vii
CommScope C9500 10G OLT Installation Guide
List of Figures
Figure 1. Front Panel...............................................................................................3
Figure 2. Slot Layout................................................................................................ 4
Figure 3. Switching and control Unit........................................................................5
Figure 4. DC-Power Supply Unit..............................................................................5
Figure 5. Fan Module Unit .......................................................................................5
Figure 6. PON Interface Unit-8EB ...........................................................................6
Figure 7. PON Interface Unit-8XE...........................................................................6
Figure 8. Line Interface Unit-8MP.........................................................................6
Figure 9. Line Interface Unit IU-8X+....................................................................6
Figure 10. Rear View...............................................................................................9
Figure 11. Top and Side View..................................................................................9
Figure 12. Side, Rear and Botttom View ...............................................................10
Figure 13. Air flow in case air baffle is not used .................................................... 11
Figure 14. DC Power Supply Unit..........................................................................12
Figure 15. Ground terminal....................................................................................13
Figure 4. Electrostatic Sensitive Devices Label.....................................................15
Figure 16. Warning Label According to IEC 60825/EN 60825 ..............................18
Figure 17. Package Contents.................................................................................20
Figure 18. Mounting on the Rack ...........................................................................23
Figure 19. Grounding on the Rack.........................................................................26
Figure 20. Bonding Network...................................................................................29
Figure 21. Installing a LINE Card with Ejectors......................................................31
Figure 22. Installing a LINE Card without Ejectors.................................................31
Figure 23. Removing LINE Card which has Ejectors .............................................32
Figure 24. Removing LINE Card which does not have Ejectors.............................33
Figure 25. PON Optic Port .....................................................................................32
Figure 26. Ethernet Optic Port................................................................................32
Figure 27. PON Network Configuration..................................................................33
Figure 28. C9500 DC Power feeding .....................................................................34
Figure 29. Connecting ConsoleTerminal ...............................................................35
Figure 30. Connecting Management Port...............................................................37
Figure 31. FMU Fail Status....................................................................................42
Figure 32. Removing a FMU..................................................................................43
Figure 33. Installing a FMU....................................................................................44
Figure 34. Installing or Removing the Dust Filter ...................................................45

1
Introduction and System Overview
Main functions and features
The CommScope C9500 10G OLT is a full-featured optical line terminal for use in today’s demanding Ethernet-
based PON networks. Designed with state-of-the-art PON technology, it supports downstream and upstream 1.25G
optical line service.
C9500 supports various functions above and beyond those found in existing Ethernet switches. The functions
include but are not limited to:
•Quality of Service (QoS) management
•Advanced system management which allows the operator to address system and subscriber issues quickly and
thoroughly
•Security protocols that safeguard system and subscriber information
•Subscriber management to ensure only approved users are able to access the system
Structure and function
The C9500 OLT connects to the Internet core network in the Central Office. It performs IP routing
and Ethernet switching, and provides a passive optical subscriber line.
The C9500 OLT can support an optical line split ratio up to 32:1 without the need for electric
power feed and management.
As a core part of the passive optical network, the C9500 OLT is part of a larger PON ecosystem
that includes:
Remote nodes (RN), typically consisting of an optical distribution network that uses passive
splitters instead of active switches to distribute traffic.
Optical network units (ONUs) that provide an interface between the PON network and its
authorized users and/or terminal devices.

2
System components
Main function and features
The C9500 delivers 10 gigabits per second (10 Gb/s) of downstream bandwidth and 10 (10 Gb/s)
or 1 gigabits per second (1 Gb/s) of upstream bandwidth over a single fiber.
The C9500 OLT platform consists of five major constituents:
•Switching & Control Unit (SCU)PON Interface Unit (PIM)
•Line Interface Unit (LIM)
•Clock Interface Unit (CIU)
•Platform Chassis
SCU
SCU is a module for packet switching and system management and up to two modules can be
installed in the platform based on active-standby redundant architecture to support fast failover
time(less than 1 second). The selective PON line redundancy is implemented as well.
PIM
PIM is a downlink interface module which supports either eight GEPON (i.e. PIM-8EB card) or
10GEPON (i.e. PIM-8XE card) interface slots. Up to ten PIM modules can be installed per
chassis as UNI (User-to-Network Interface). Two PON ports can be configured as active
standbyredundant combination to increase the availability of service so that C9500 can utilize
‘2:N’ split ratio rather than ‘1:N’ which can enhance the PON line interface availability and
reliability.
LIM
LIM provides service interface to upper layer network equipment that is typically connected to
the Backbone network. The LIM supports either 8-port 1000Base-X (i.e. LIM-8MP card) or 8-
port 10GBase-R (i.e. LIM-8X+ card) per module.Up to two modules can be accommodated in a
C9500 platform as NNI (Network-to-Network Interface).
CIU
CIM is a clock interface module to handle clock information from other clock source to

3
synchronize the time based on IEEE1588 or SyncE. It is an optional module and is not included
in this version of the installation guide. C9500 Installation Guide 13
5. Platform Chassis
Platform Chassis is a set of basic components including system shelf, fan modules and power
supply modules.
A. System Shelf
System Shelf consists of chassis and backplane board and provides slots to hold the above
major constituent modules such as SCU, LIM and PIM. Backplane is designed based on a single
bus architecture.
B. PSU
PSU is the power module for the C9500 and up to two modules can be installed in one platform
chassis. The Power modules ensure continuous operation without suffering system halt in case
of a power module failure.
C. FMU
Platform chassis is equipped with three fan modules (FMUs) to ventilate hot air from inside the
enclosure. Three FMU modules are used in a platform chassis.
Figure 1: Front Panel

4
Figure 2. Slot Layout
Caution You must install Interface cards in the relevant slots. A LIM card (LIM-
8M or LIM 4X) must install in the #5 or 6 slot and a PIM card (PIM-8G)
must install in the PIM slots.
C9500 Component Descriptions
Table 1. C9500 Component Descriptions
Unit Description Remarks
SCU
SCU (Switching and Control Unit)
- System Switching and Controller Processor Module Card
- Active-Standby Redundant Configuration
Common
PSU-DC DC -48V Power Module: Supporting redundancy. Common
CIM Time Synchronization interface Module (1588v2, SyncE)
FMU FMU (FAN Module Unit, 3 FMUs per Chassis) Common
PIM-8EB
8-port 1.25G EPON Line Card
The applicable EPON optical module is SFP type. - Note
(1)
PON Interface
PIM-8XE 8-port 10G EPON Line Card PON Interface
LIM-8MP 1000Base-X 8port Line Card The applicable optical module Line Card

5
is SFP type - Note (2)
LIM-8X+ 10GBase-xR 2-port Line Card Line Card
Note (1) – Use only approved supported SFP modules for the Line Card.
Caution
Observe precautions for handling electrostatic sensitive devices.
Caution Risk of explosion if battery is replaced with an incorrect type. Dispose of used batteries
according to the instructions.
Figure 3. Switching and control Unit
Note
You can check the position of the PSU cards by the direction. Looking at the
front of the system, The left side of chassis is the left PSU and the right side of
chassis is the right PSU. You can also verify via the CLI (Command Line
Interface).
Figure 4. DC-Power Supply Unit
Figure 5. Fan Module Unit
Warning
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do
not stare at the beams or gaze into the optical instruments.

6
Caution
Observe precautions for handling electrostatic sensitive devices.
Figure 6. PON Interface Unit-8EB
Figure 7. PON Interface Unit-8XE
Figure 8. Line Interface Unit-8MP
Figure 9. Line Interface Unit IU-8X+
Table 2. LED status description
Unit LED Status Description
SCM
PWR Green On Power on
Off Power Off
Orange On Reset or power fail
CR Red On System critical alarm on
OFF System critical alarm off
MJ Orange On System major alarm on
OFF System major alarm off
MN Orange On System minor alarm on

7
OFF System minor alarm off
FAN Green On FAN normal status
Orange On FAN alarm status
ACT/ST Green Blink SCU active operation mode
Orange On SCU standby operation mode
USB/BUSY Green On USB memory busy status
OFF USB memory run status
LNK/ACT Green On Management Ethernet link up
PSU Power Green On Power ON
Off Power OFF
FMU
Run Green On Fan ACT
Off Fan STOP
Fail Red On Fan Fail
Off Fan Normal
PIM-
8XE
Power Green On Power On
Off Power Off
Orange On Reset
P1~P8
Green
Off 10G PON Link On
On 10G PON Link Off
Blink 10G PON Tx/Rx data is present
Blue
On 10G PON Link On
Off 10G PON Link Off
Blink 10G PON Tx/Rx data is present
Orange On Traffic amount exceeds the threshold which has been set by
CPU for that specific port
PIM-
8EB
Power Green On Power On
Off Power Off
Orange On Reset
P1~P8 Green On 1G PON Link On
Off 1G PON Link Off

8
The SCU provides packet switching and system management for the C9500 OLT. Up to two SCU modules can be
installed based on active-standby redundant architecture to support fast failover time(less than 1 second). The
selective PON line redundancy is implemented as well.
Blink 1G PON Tx/Rx data is present
Orange On Traffic amount exceeds the threshold which has been set by
CPU for that specific port
LIM-
8X+
Power Green On Power On
Off Power Off
Orange On Reset
P1~P8
Green
On 10G PON Link On
Off 10G PON Link Off
Blink 10G PON Tx/Rx data is present
Orange On Traffic amount exceeds the threshold which has been set by
CPU for that specific port
CIU Power Green On Power On
Off Power Off

9
Figure 10. Rear View
Figure 11. Top and Side View
Fan Ventilation
The C9500 chassis incorporates three fan modules at the top of the chassis which drive the
heated air in the direction of ‘from bottom/front to top/rear’ flow. If air baffle is not applied, then
the air flow would be ‘from bottom to top/rear’. Please see Figures 12 and 13.
For your information, the heat dissipation value (the heat release in Watts per foot of frame
vertical height used) is 90W/ft2/ft.

10
Figure 12. Side, Rear and Botttom View

11
Figure 13. Air flow in case air baffle is not used
Caution
The C9500 locates the Fan Module (FMU) on the top of the device.
Cooling is accomplished by making the hot air rise from the bottom
(convection cooling). Thus, if the top and the bottom of the device are
blocked, the internal warm air and the external cold air cannot be
circulated properly and the product could overheat.
Power Supply
C9500 uses a DC power source to supply power to the system. On the front side of the PSU
card there are two GND terminals as shown below.
Caution
Observe precautions for handling electrostatic sensitive devices.
Table of contents
Other CommScope Touch Terminal manuals

CommScope
CommScope FST-T User manual

CommScope
CommScope MST-4 User manual

CommScope
CommScope FST-R User manual

CommScope
CommScope Mini-OTE 400 User manual

CommScope
CommScope OmniReach RLX User manual

CommScope
CommScope NOVUX Small User manual

CommScope
CommScope TC-1511-IP User manual

CommScope
CommScope FACT User manual

CommScope
CommScope CS6204W User manual

CommScope
CommScope OmniReach FTTX Solutions User manual