, Keyless Locking 6
Part Number Descriptions
Example: REG-AT-S-L-3-BK
REG-AT = RegulatoR Standard Knob w/audit trail
REGS-AT = RegulatoR Short Knob w/audit trail
Version:
S= Self-locking; featuring SlamCAM
M= Manual locking, standard CompX National cams
Mounting:
L= Left hand mount, door application - hinge on left side when facing cabinet
R= Right hand mount door application - hinge on right side when facing cabinet
V= Vertical mount door application (keypad located above locking point)
T= Top vertical mount door application (keypad located below locking point)
Cylinder Length:
1= 7/16" cylinder length
3= 1-3/16" cylinder length
5= 1-3/4" cylinder length
Color:
BK = Matte black housing & knob
No suffix = Standard silver housing & knob
-------------------------------------------------------------------------------------------------
Replacement Parts
REG-KIT-KNOB - replacement knob kit
REG-KIT-KNOBS - replacement short knob kit
213005000000J - replacement battery door
, Keyless Locking 3
Packaged Components cont.
Contents – Self-Lock Version:
•Self-locking Lock assembly featuring
SlamCAM
•(2) AAA alkaline batteries
•SlamCAM spacer discs
•Mounting hardware
Powering Up and Battery Installation
CompX
®
is shipped with two installed AAA batteries. While
features a low battery indicator, scheduled battery replacement is
recommended. Mixing batteries of different chemistries could damage the
resulting in lock failure.
To power up , pull the red tag. The lock is now ready for use.
Note: In the event the batteries should die, they can be replaced via the external
battery compartment.
If equipped, a tamper resistant T-15 pin-in Torx
®
(6-lobe) bit or driver (not
included) will be required to remove the battery cover.
Restoring Factory Codes
The RegulatoR -AT features a factory reset code which will restore the default
1-2-3-4 & 1-2-3-4-5 codes. The was shipped with reset stickers;
one attached to the back of the and an extra sticker that should
be kept in a safe and secure location for future reference if needed.
To restore the factory default codes, type the Factory Reset Code assigned to the
and press and hold ENTER for 3 seconds.
Care and Cleaning
To clean the surface, apply non-acid based cleaner to a clean
cotton cloth; do not spray cleaner directly on the . Wipe down
keypad and its respective housing surfaces of excess cleaner.