Cordex LM3000 User manual

USER
MANUAL
LM3000
EXPLOSION PROOF
LASER DISTANCE METER
RUGGED AUTHORITY www.cord-ex.com

Congratulations – You are the
owner of the next generation
explosion proof laser distance
meter designed and certified
specifically for use in hazardous
(explosive) atmospheres.
CONTENTS
Getting To Know Your 3000XP 4-5
Overview 7
Preparation 8
Settings 9
Basic Operation 10-11
Advanced Functions 12-15
Troubleshooting 16
Specification 17
WARNING! LASER HAZARD!
This device is a Class II laser
product (< 1mW, 635nm,
EN60825-1:2002). Never look
directly at the laser beam, aim
it at people or shine it at highly
reflective surfaces: it may cause
eye damage.
3000XP is certified CSA as follows:
• Class 1 Div.I hazardous (explosive) area
!

On / measure distance
Cancel last action / Off (hold
button for 2s)
Change reference (front/back)
/ turn backlight on/off (hold
down for 2s)
Addition (one press),
subtraction (two presses) /
change units (hold key for 2s)
Advanced mode: Area (one
press) / Volume (two presses)
Pythagorean - calculate
hypotenuse (three presses)
Pythagorean - calculate
opposite side (four presses)
Reference indicator
Area/volume/Pythagorean
mode
Battery charge indicator
Secondary display
Laser activity indicator
Addition/subtraction mode
Units
Main display area
REF/
LIGHT
A / V / P
OFF/
CLEAR
UNITS
ON / DIST ftim
ftim
19
19
18
18
GETTING TO KNOW
YOUR 3000XP
1
6
8
5
7
5
2
3
4
Keypad Display
5 6
4
4
5
7
8
1 1
2 2
3 3
31 42
RUGGED AUTHORITY
LaserMETER 3000XP - Explosion-proof Laser Distance Meter
5

Focus Ring 135˚ Swivel Lens
OVERVIEW
PACKAGE CONTENTS
Congratulations on your purchase of the
LaserMETER 3000XP.
The LaserMETER 3000XP is an explosion-
proof laser distance meter, CSA-certified
for use within a Class 1 Div.I hazardous
(explosive) area. The robust IP65 design
incorporates a shock resistant, anti-static
overmold, interchangeable battery pack and
backlit LCD display.
The LaserMETER 3000XP is capable of
measuring distances of 30m (100ft) with
an accuracy of 3mm (0.1in) - accuracy may
vary depending on reflectivity and ambient
conditions. It allows Pythagoras, Area and
Volume calculations.
Carefully unpack your LaserMETER 3000XP
and ensure that you have the following items:
• LaserMETER 3000XP
• Removable/rechargeable battery pack
• Safe area charging station
• Wrist strap
• Power pack
• Battery removal tool
RUGGED AUTHORITY
LaserMETER 3000XP - Explosion-proof Laser Distance Meter
7

2
Load the battery pack paying careful attention
to its orientation.
3
Close the battery cover, replace the screws
and make sure the cover is locked securely.
Switching On and Off
To switch the meter on, press the ON/DIST
To switch the unit off, press and hold down
the CLEAR/OFF button. The device also
switches off automatically if no key is pressed
within 3 minutes. button.
Never open the battery
compartment in a hazardous
environment. Only use cordex
approved battery packs.
!
Battery Pack and Charging
Place the CorDEX Approved Battery Pack
in the supplied Charging Station. Plug
the charger into a suitable mains supply.
The green LED flashes during charging,
and remains on when the battery is fully
charged (approximately 2 hours). Do not
leave batteries in the charger longer than
is necessary - this may lead to shortened
battery life.
WARNING! Only use CorDEX Approved Battery
Packs Only (CDX2341-007). There could be a
risk of explosion if other types of batteries are
charged.
Please note that batteries can become warm
during the charge cycle.
Do not attempt to open the charger.
Keep the charger in a dry place (indoor use
only).
Do not use the charger if there are any signs of
damage to the housing, mains, pins, cables or
connectors. In case of a defect, please return
to an authorized service center.
Loading the battery:
1
Open the LaserMETER’s battery compartment.
Remove the six retaining screws using the
supplied battery removal tool.
Connecting the Reference Mode
When you make a measurement using the
LaserMETER, the distance is measured from
either the front or back of the device (default).
The reference point is indicated by an icon on
the left of the screen.
If you want to change the reference point,
press the Reference button until the required
mode is displayed.
Choosing The Units
Distances
The LaserMETER can display measurements
in metres, feet, feet & inches, or inches. To
cycle through the seven display formats,
shown opposite, press the UNITS button.
Areas
You can display areas in three formats:
0.000m², 0.00m² or 0.00ft².
Press the UNITS button to cycle through these
options.
Volumes
You can display volumes in three formats:
0.000m³, 0.00m³ or 0.00ft³.
Press the UNITS button to cycle through these
options.
PREPARATION
BACK
FRONT
ftim
19
18
ftim
19
18
ftim
ftim
19
18
ftin
13
16
ftin
13
16
ftin
13
16
ftin
13
16
SETTINGS
RUGGED AUTHORITY
LaserMETER 3000XP - Explosion-proof Laser Distance Meter
9

BASIC OPERATION
Single Measurements
1. Press the ON/DIST button to switch on the
meter. The laser is activated. Place the meter
against a stable surface and aim the laser at
the far end of the range to be measured.
2. Press the ON/DIST button again to take the
measurement. The laser is deactivated.
3. To take another measurement, press the
ON/DIST button again. The laser is activated.
Your previous measurement is transferred
to the secondary display area. Aim the laser
as before.
4. Press the ON/DIST button again. The new
measurement is shown in the main display
area.
Continuous Measurement
Hold down the ON/DIST button for about
2 seconds to start continuous measuring.
The meter beeps with each updated
measurement. During continuous measuring,
the latest measured value is displayed in
the main display area. The previous value is
displayed in the secondary display area.
Addition/Subtraction
1. Press the ON/DIST button to switch on the
meter and activate the laser.
2. Press the ON/DIST button again to take your
first measurement as described previously.
3. Press the +/- button once for an addition
or twice for a subtraction operation,
as required. The first measurement is
transferred to the secondary display area.
4. Press the ON/DIST button again to take the
next measurement. Its value is displayed in
the secondary display area; the result of the
addition/subtraction operation is shown in
the main display area.
5. Repeat these steps to carry out further
addition/subtraction operations.
ftim
ftim
M
19
19
18
18
ftim
ftim
M
19
19
18
18
ftim
ftim
M
19
19
18
18
ftim
ftim
M
19
19
18
18
ftim
ftim
M
19
19
18
18
ftim
ftim
M
19
19
18
18
ftim
ftim
M
19
19
18
18
RUGGED AUTHORITY
LaserMETER 3000XP - Explosion-proof Laser Distance Meter
11

ADVANCED
FUNCTIONS
Area
1. Position yourself at one corner of the area to
be measured (X - see diagram).
2. Press the ON/DIST button to switch on the
LaserMETER.
3. Press the A/V/P button once. The area
symbol is displayed.
4. Point the laser at one of the adjacent
corners in the area (A). Press the ON/DIST
button. The length A-X is measured and
displayed in the secondary display area.
5. Point the laser at the other adjacent corner
(B). Press the ON/DIST button again.
The meter displays the length X-B in the
secondary display area. It calculates
and displays the area based on the two
measurements (XA x XB) and displays it in
the main display area.
Volume
1. Position yourself at one corner of the volume
to be measured (X - see diagram).
2. Press the ON/DIST button to switch on the
meter.
3. Press the A/V/P button twice. The volume
symbol is displayed and the laser is
activated.
4. Point the laser at one of the adjacent
corners in the area (A). Press the ON/DIST
button. The length A-X is measured and
displayed in the secondary display area.
5. Point the laser at another adjacent corner
(B). Press the ON/DIST button again.
The meter displays the length X-B in the
secondary display area.
6. Point the laser at another adjacent corner
(C). Press the ON/DIST button again.
The meter displays the length X-C in
the secondary display area. The meter
calculates the volume (XA x XB x XC) and
displays it in the main display area.
RUGGED AUTHORITY
LaserMETER 3000XP - Explosion-proof Laser Distance Meter
13

PYTHAGOREAN (hypotenuse mode)
The Pythagorean mode allows you to measure
distances accurately when it is not possible
to gain access to an area, or when there is an
obstacle preventing a direct line of sight. The
first mode calculates the hypotenuse from two
measurements taken at right angles.
1. Position yourself so that:
You can see both measurement points (A
and B) and the lines (X-A) and (X-B) are at
right angles (see diagram).
2. Press the ON/DIST button to switch on the
meter.
3. Press the A/V/P button until the symbol is
displayed.
4. Aim the laser at the first measurement point
(A) and press the ON/DIST button. The meter
measures the distance: X-A, and displays it
in the secondary display area.
5. Moving the meter as little as possible, rotate
it through 90°and point it at the second
measurement point (B).
6. Press the ON/DIST button again. The meter
measures the distance: X-B and displays it
in the secondary display area.
The meter calculates the distance A-B and
displays it in the main display area.
PYTHAGOREAN (baseline mode)
The second Pythagorean mode calculates a
baseline length from the measurements of the
hypotenuse and the adjacent side.
• Position yourself so that:
You can see both measurement points (A
and B) and the lines (X-A) and (A-B) are at
right angles (see diagram).
• Press the ON/DIST button to switch on the
meter.
• Press the A/V/P button until the symbol is
displayed. Press the mode button again (the
hypotenuse of the symbol flashes).
• Aim the laser at the first measurement point
(A) and press the ON/DIST button. The meter
measures the distance: X-A, and displays it
in the secondary display area.
• Moving the meter as little as possible, rotate
it to aim at the second measurement point
(B).
• Press the ON/DIST button again. The meter
measures the distance: X-B and displays it
in the secondary display area.
The meter calculates the distance A-B and
displays it in the main display area.
ADVANCED
FUNCTIONS (CONT)
RUGGED AUTHORITY
LaserMETER 3000XP - Explosion-proof Laser Distance Meter
15

TROUBLESHOOTING SPECIFICATION
Error Message
204 Data overflow Repeat the measurement steps.
205 Measurement
range exceeded
The meter has a maximum range of 30m (100ft). If you need to
measure a greater distance, try to break it down into smaller steps.
252 Temperature too
high
Allow the meter to cool down and then repeat the measurement.
253 Temperature too
low
Warm the meter and then repeat the measurement.
255 Received signal
too weak
Select another target point with higher reflectivity.
256 Received signal
too strong
Select another target point with lower reflectivity.
257 Pythagorean
measurement
violation
Repeat the measurement and ensure the hypotenuse is greater than
the right angle edge.
258 Initialization
error
Turn the meter off, wait a few seconds and then turn it back on.
Hardware error Turn the meter off, wait a few seconds and then turn it back on.
Certification information
Certificate No 2379424
Certificate Type: Class I Div.1 Groups B, C, D
Ambient Temperature: Tamb -20°C to +50°C
General Information
Range 0.5m (1.6ft) to 30m (100ft)
Measuring Accuracy Typically: 3mm (0.1in)
Measurement Unit Displayed m, ft, ftin, in
Laser Type/ Class 635mm, <1 mW, II
Acc IEC 60825-1 : 2001
Body/ Lens and LCD Cast Aluminium chassis with anti-static over-mould/Toughened safety
glass
Emited Wavelength 620-690nm
IP 54
Detailed Information
Weight <1kg (<2.2lb)
Dimensions Length 140mm (5.5in), height 130mm (5.1in) width 75mm (3.0in)
Functions Pythagoras, Volume, Area
Electrical Information
Battery type Rechargeable
Capacity 1100mAh
Cell type NiMH
Cause Correction
If any of these problems persist,
please contact your dealer.
!
RUGGED AUTHORITY
LaserMETER 3000XP - Explosion-proof Laser Distance Meter
17

Copyright © 2014, CorDEX Instruments Limited.
All other brand and product names are
trademarks of CorDEX Instruments Limited. Ref. ID 2102, Rev. B
Table of contents