BEFORE USE
• To retain wrench accuracy, DO NOT
LOOSEN nuts, bolts, etc. USE ONLY
FOR TIGHTENING.
• Apply a small amount of oil between
handle and wrench body.
Note: If wrench is not used for an extended
time, turn handle to lowest torque setting
on wrench body. Rotate handle in both
directions while making a few “clicks”. This
re-lubricates the wrench.
INSTRUCTIONS
1. Select Wrench from case.
2. Insert END into socket. Wrench size
and arrow must be same side.
Fig. 1
3. Loosen Locking Knob
counterclockwise to unlock handle.
4. Select FOOT-Pound Scale Fig. 2 or
INCH-Pound scale Fig. 3
5. Determine Proper Torque Setting
For Equipment Being Serviced
(use setting specified by equipment
manufacturer).
6. To obtain torque values ending
in ‘0’, align (0) and Handle Edge
with Torque Value On Vertical
Scale See Fig. 2 and Fig. 4 .
7. For torque values NOT ending
in ‘0’, twist handle and align
appropriate handle mark at handle
edge with Torque Value On
Vertical Scale.
8. Tighten Locking Knob clockwise
to lock in your torque setting.
9. Tighten Equipment Fitting, Bolt,
Nut Until Clicks Are Felt/Heard
From Pivot Point Note: To prevent
tool damage, avoid further pressure on
wrench after torque (clicks) achieved.
Removable
Wrench End
Socket
Pivot Point
Torque
Values on
Vertical
Scale
Handle
Scale (0 to 5)
Arrow
Indicates
Tightening
Direction
Wrench
Body
Handle
Locking
Knob
Wrench Size
and Arrow
Must Be
Same Side
Handle
Edge
Fig. 1