SO
L
U
TI
O
N
S
TM
A Roscoe Medical Company
CURRENT
The purpose of this guide is to assist you in correctly operating your Intensity™ 5000 Hybrid unit.
This device should only be used under the continued supervision of a licensed physician. This
guide is not intended to replace or substitute the Intensity™ 5000 Hybrid Instruction Manual.
PLEASE READ THE INSTRUCTION MANUAL COMPLETELY BEFORE USING THIS DEVICE. Read,
understand and practice the warnings, cautions and operating instructions. Always follow the
operating instructions prescribed by your healthcare provider.
QUICK REFERENCE GUIDE PAGE 1
1 2
Top
SideFront Back
3
4
5
67
8
9
10
11
INTENSITY™
5000 HYBRID
UNIT
ELECTRODES
2 SETS
LEAD WIRES
2 SETS
For more information about your Intensity™ 5000 Hybrid unit, visit us at currentsolutionsnow.com or call 1-800-871-7858.
12 13
14
18
16
17
19
15
Channel 1 Intensity output indicator
Channel 2 Intensity output indicator
Channel 1 intensity increase button
Channel 1 intensity decrease button
Channel 2 intensity increase button
Channel 2 intensity decrease button
Key-press cover
Therapy mode LED indicator
Therapy mode button
Therapy time button
Therapy time LED indicator
Pulse width button
Pulse rate button
On/O button
Channel 1 output socket
Channel 2 output socket
Belt clip
Battery compartment cover
Adapter receptacle
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
2CONNECT ELECTRODES
TO LEAD WIRES
Firmly insert
the lead wire
connectors into
the electrode
connectors.
Make sure the bare metal of the pins is not exposed.
3CONNECT LEAD WIRES
TO TOP OF DEVICE
This unit operates
with one or two sets
of electrodes. When
using one set, plug
lead wire into Channel
1 on top of the unit.
Use Channel 2 to
operate a second set
if directed to do so
by your healthcare
provider.
4PLACE ELECTRODES
ON SKIN 6SELECT
THERAPY MODE
Remove electrodes from
protective backing. Keep
backing to properly store
electrodes after use.
Apply electrodes to the
exact site indicated by
your doctor or therapist.
Make sure the skin at the
application site is clean
and dry.
7ADJUST PULSE WIDTH
AND PULSE RATE
Turn the PW knob clockwise to select pulse width.
The pulse width is adjustable from 30 uS to 260 uS.
Turn the PR knob clockwise to select pulse rate.
The pulse rate is adjustable from 2 Hz to 150 Hz.
8SELECT
THERAPY TIME
5TURN DEVICE ON
Please see pages 24 and 25 of your Intensity™ 5000 Hybrid Instruction Manual for troubleshooting tips.
PROBLEMS WITH YOUR DEVICE?
Steps 1–4 should be performed with the device turned OFF.
Once the unit has been turned ON, do not remove electrodes
without rst turning OFF the device.
IMPORTANT!
SO
L
U
TI
O
N
S
TM
A Roscoe Medical Company
CURRENT
QUICK REFERENCE GUIDE PAGE 2
Press the ON/OFF button located out the
bottom of the control panel.The mode LED indicator
and timer LED indicator will light up.
See Electrode Placement Guide for more information.
1INSERT BATTERY
Press arrow and slide battery compartment
cover open. Insert 9V battery, matching the
+ and – ends to those in unit.
The included AC adapter may
also be used as a power source.
ON/OFF
There are 5 therapeutic modes available:
B(burst), N(normal), M1 (pulse width
modulation), M2 (pulse rate modulation) and
SD (strength duration).
Press the MODE button and continue to press to
select desired mode.
P.R. (Hz)
P.W. (uS)
There are 4 therapy times available: 15 minutes, 30
minutes, 60 minutes and Cfor continuous.
Press theTIMER button and the appropriate time LED
indicator will illuminate. Continue to press to select
desired time.
9ADJUST CHANNEL
INTENSITY
Press the intensity control button
sand t to control the intensity
output.You will hear a“beep”sound.
Slowly press the intensity button
control until you reach the setting
recommended by your physician or
therapist. Repeat for other channel if
both channels are being used.
The Safety Lock Feature automatically locks the
settings if no changes have been made in the panel for
20 seconds.This feature prevents accidental changes to
your settings. Press the tbutton to unlock the device.
MODE TIMER
B N M1 M2 SD
15 30 60 C
MODE TIMER
B N M1 M2 SD
15 30 60 C

Other manuals for InTENSity 5000 Hybrid

1

Popular Timer manuals by other brands

claber Cometa user manual

claber

claber Cometa user manual

MULTISPAN UTR-4244 manual

MULTISPAN

MULTISPAN UTR-4244 manual

Störk-Tronic ST710-PCA.07 Wiring diagram

Störk-Tronic

Störk-Tronic ST710-PCA.07 Wiring diagram

TechGrow Seconds Interval Timer user manual

TechGrow

TechGrow Seconds Interval Timer user manual

CARLO GAVAZZI DAA01 installation instructions

CARLO GAVAZZI

CARLO GAVAZZI DAA01 installation instructions

NOMA 52-8867-6 Operation manual

NOMA

NOMA 52-8867-6 Operation manual

Prince Castle Merlin II 740-T Series operating instructions

Prince Castle

Prince Castle Merlin II 740-T Series operating instructions

Orbit B-hyve user manual

Orbit

Orbit B-hyve user manual

Ascon tecnologic T82N user manual

Ascon tecnologic

Ascon tecnologic T82N user manual

Theben SELEKTA 171 Top3 RC quick start guide

Theben

Theben SELEKTA 171 Top3 RC quick start guide

Novus TM-619 user guide

Novus

Novus TM-619 user guide

Defiant 1000-003-074 user manual

Defiant

Defiant 1000-003-074 user manual

Siemens 7LF5 3001 quick start guide

Siemens

Siemens 7LF5 3001 quick start guide

Orbit Watermaster 57004 Installation and user manual

Orbit

Orbit Watermaster 57004 Installation and user manual

Inepro MicroTimer 2400 Technical manual

Inepro

Inepro MicroTimer 2400 Technical manual

Fogmaster 2239 quick start guide

Fogmaster

Fogmaster 2239 quick start guide

Toro ECXTRA Installation and operation

Toro

Toro ECXTRA Installation and operation

Tork DGS100A instruction manual

Tork

Tork DGS100A instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.