CyberPower BU600E User manual

BU600E/1000E
User’s Manual
K01-C000046-00
IMPORTANT SAFETY INSTRUCTIONS
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or
operate your UPS.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor
area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity
range.)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing
the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment,
microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other
liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC
power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries
and the required precautions. Keep unauthorized personnel away from batteries.
CAUTION! The battery supply should be therefore disconnected in the plus and minus pole at the quick
connectors of the battery when maintenance or service work inside the UPS is necessary.
CAUTION! Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or
batteries. Released electrolyte is harmful to the skin and eyes.
INSTALLING YOUR UPS SYSTEM
UNPACKING
The box should contain the following: (1) UPS Unit x1; (2) User Manual x1
OVERVIEW
The BU600E/1000E provides automatic voltage regulation for inconsistent utility power, and provides battery
backup during power outages. The BU600E/1000E ensures consistent power to your computer system.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours
is recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss may occur
during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The
unit will charge in both the on and off position.
2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data
storage device (Zip drive, Jazz drive, Tape drive, etc. into the battery power supplied outlets. DO NOT plug
a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into
the battery power supplied outlets. The power demands of these devices will overload and possibly
damage the unit.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air
conditioner, refrigerator, copier, etc. Avoid using extension cords.
4. Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit will
"beep".
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this,
turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait
10 seconds. Make sure the circuit breaker / fuse is normal and then turns the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the
battery every three months to ensure battery life.
BASIC OPERATION
1. Power Switch
Press the switch for 2 seconds to turn the UPS ON or OFF.
Alarm setting: The audible alarm can be turned OFF or ON by quickly pressing the POWER
button twice. The default setting is for the Alarm On. To turn the Alarm Off, quickly press
the power button twice. You will hear two short beeps when the Alarm is turned off. To
turn the Alarm back on, quickly press the power button twice. You will hear a single short
beep when the Alarm is turned on.
2. Led Indicators
This LED is illuminated when the UPS is working.
3. Input Fuse/Breaker
The fuse/breaker provides optimal overload protection.
4. Input Power Cord
Connect to utility power.
5. AC outlet
The UPS provides outlets for connected equipment to insure temporary uninterrupted operation during a
power failure and against surges and spikes.
TECHNICAL SPECIFICATIONS
DEFINITIONS FOR ILLUMINATED LED INDICATORS
LED
Alarm
Condition
On Off Normal
Flash Beep Twice Utility Failure - The UPS is providing battery power to outlets.
Flash Rapid Beeping
Utility Failure - The UPS is providing battery power. The rapid beeps indicate the battery will
run out of power shortly.
On/Flash Constant Tone
Overload - Occurs when connected equipment exceeds the rating of the unit. Turn the UPS off
and unplug at least one piece of equipment from the UPS.
TROUBLESHOOTING
Problem Possible Cause Solution
The UPS does not perform expected
runtime.
Batteries are not fully charged.
Recharge the battery by leaving the UPS
plugged in.
Battery is slightly worn out.
Contact CyberPower Systems Technical
Support.
The UPS will not turn on.
The unit is not connected to an AC outlet.
The unit must be connected to a 220-240V
outlet.
The battery is worn out.
Contact CyberPower Systems Technical
Support.
Mechanical problem.
Contact CyberPower Systems Technical
Support.
Outlets do not provide power to
equipment
Fuse is blown or breaker is tripped due to
overload.
Turn the UPS off and unplug at least one
piece connected equipment. Unplug the
power cord of the UPS then replace the blown
fuse with a spare one or press the circuit
breaker knob. Connect power cord then turn
the UPS on. Make sure that your spare fuse
meets the specification.
Batteries are discharged Allow the unit to recharge for at least 4 hours.
Unit has been damaged by a surge or spike.
Contact CyberPower Systems Technical
Support.
For more information, visit www.cpsww.com
All rights reserved. Reproduction without permission is prohibited.
Model BU600E-IN BU1000E-IN
Capacity (VA) 600 1000
Input
Voltage Range 140~300Vac
Nominal Frequency 50 Hz
Output
On Battery Output Voltage Simulated Sine Wave at 220Vac +/-5%
On Battery Output Frequency 50 Hz +/-1%
Overload Protection Breaker / Fuse
Physical
Total # of UPS Receptacles 3 4
Maximum Dimensions (L*W*H) 240*158*91.5mm 290*190*110.5mm
Weight 3.8 kg 6.9 kg
Battery
Sealed Maintenance Free Lead Acid
Battery RBP0043 x1 RBP0046 x2
Typical Recharge Time 8 Hours
Warning Diagnostics
Indicators Power On / Using Battery
Audible Alarms On Battery, Low Battery, Overload, Fault
Environmental
Operating Temperature 0C to 40C
Operating Relative Humidity 0 to 90%
Management
Auto-Charger Yes
Auto-Restart Yes

This manual suits for next models

1

Other CyberPower UPS manuals

CyberPower CP750LCD User manual

CyberPower

CyberPower CP750LCD User manual

CyberPower AVR CP850PFCLCD User manual

CyberPower

CyberPower AVR CP850PFCLCD User manual

CyberPower Professional Tower UPS PP1500E User manual

CyberPower

CyberPower Professional Tower UPS PP1500E User manual

CyberPower Paragon OL3000RMXL2U User manual

CyberPower

CyberPower Paragon OL3000RMXL2U User manual

CyberPower PR750ELCD User manual

CyberPower

CyberPower PR750ELCD User manual

CyberPower OR1000LCDRM1Ua User manual

CyberPower

CyberPower OR1000LCDRM1Ua User manual

CyberPower OLS3S15KE User manual

CyberPower

CyberPower OLS3S15KE User manual

CyberPower PR750LCDN User manual

CyberPower

CyberPower PR750LCDN User manual

CyberPower CP1300EPFCLCD User manual

CyberPower

CyberPower CP1300EPFCLCD User manual

CyberPower Value 600E-GP User manual

CyberPower

CyberPower Value 600E-GP User manual

CyberPower AVRG750LCD User manual

CyberPower

CyberPower AVRG750LCD User manual

CyberPower MBP60AHVIEC82U User manual

CyberPower

CyberPower MBP60AHVIEC82U User manual

CyberPower CyberShield CSN75A12V3 User manual

CyberPower

CyberPower CyberShield CSN75A12V3 User manual

CyberPower PowerPanel Cloud User manual

CyberPower

CyberPower PowerPanel Cloud User manual

CyberPower 3000 VA User manual

CyberPower

CyberPower 3000 VA User manual

CyberPower AVRG750U User manual

CyberPower

CyberPower AVRG750U User manual

CyberPower UT400EG User manual

CyberPower

CyberPower UT400EG User manual

CyberPower 649532715046 User manual

CyberPower

CyberPower 649532715046 User manual

CyberPower PR1000ELCDRTXL2U User manual

CyberPower

CyberPower PR1000ELCDRTXL2U User manual

CyberPower Pro VP1000ELCD User manual

CyberPower

CyberPower Pro VP1000ELCD User manual

CyberPower PR5000LCDRTXL5U User manual

CyberPower

CyberPower PR5000LCDRTXL5U User manual

CyberPower AVR Series User manual

CyberPower

CyberPower AVR Series User manual

CyberPower 649532830022 User manual

CyberPower

CyberPower 649532830022 User manual

CyberPower CP1350PFCLCD User manual

CyberPower

CyberPower CP1350PFCLCD User manual

Popular UPS manuals by other brands

Eaton 5000 VA user manual

Eaton

Eaton 5000 VA user manual

Energenie EG-UPS-H650 user manual

Energenie

Energenie EG-UPS-H650 user manual

rocpower MAGNUS user manual

rocpower

rocpower MAGNUS user manual

Sven Power Pro+ 500 user manual

Sven Power

Sven Power Pro+ 500 user manual

DKC INFO400 user manual

DKC

DKC INFO400 user manual

SynQor 3-Phase UPS-1500 Series Operator's guide

SynQor

SynQor 3-Phase UPS-1500 Series Operator's guide

GMP GM 110 PRO user manual

GMP

GMP GM 110 PRO user manual

Tripp Lite OmniPro 675 owner's manual

Tripp Lite

Tripp Lite OmniPro 675 owner's manual

Tripp Lite SMART3000RM2UL owner's manual

Tripp Lite

Tripp Lite SMART3000RM2UL owner's manual

Xtreme Power Conversion XVT 600VA User & installation manual

Xtreme Power Conversion

Xtreme Power Conversion XVT 600VA User & installation manual

Sy-G Challenger Series user manual

Sy-G

Sy-G Challenger Series user manual

Ablerex KRONOS Installation and operation manual

Ablerex

Ablerex KRONOS Installation and operation manual

Huawei UPS5000-S Series user manual

Huawei

Huawei UPS5000-S Series user manual

Always “On” UPS DC UPS Systems user manual

Always “On” UPS

Always “On” UPS DC UPS Systems user manual

Riello UPS Sentryum S3T installation manual

Riello UPS

Riello UPS Sentryum S3T installation manual

Sonnen 22320 installation instructions

Sonnen

Sonnen 22320 installation instructions

Riello MULTI SENTRY MST 60 manual

Riello

Riello MULTI SENTRY MST 60 manual

PowerShield PSDCMin12 quick guide

PowerShield

PowerShield PSDCMin12 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.