Cybertek CP9000S Series User manual

Shenzhen Zhiyong Electronics Co., Ltd.
www.cybertek.cn
Flexible Current Probe
CP9000(S/L)
Shenzhen Zhiyong Electronic Co., Ltd
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd.
1
Contents
Summary…………………………………………………………………………….………...…2
Application…………………………………………………………………………………….…2
Electrical Specifications………………………………………………………………….............3
Products and Accessories……………………………………………………………………...…4
Products…………………………………………………………………………..…….…..4
Accessories…………………………………………………………………….….…..……5
Typical Mechanical Specifications ………………..…………………………..………..……….6
Environment Specifications……………………………..………………………………...……..6
Measurement Procedure………………………….………..…………………………. …..….…6
Attentions..……………………………………………………………………………….…..….6
Care and Maintenance …………………………………………..………………….….….….....7
Service Strategy……………………………………………………………..……….….…….…7
Packing List…………………………………………………………………….…...….….…….7
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd.
2
1. Summary
CP9000(S/L)Series are AC Flexible Current Probe .It has the advantages of
high bandwidth, high precision (typically 1%) characteristics. The frequency can be from
several Hz to tens of MHz, current ranges from mA level to kA level, which solves the
problem of current test.
The main features include:
easy to measure with thin ,flexible ,clip-around coil; Non-intrusive-loading the circuit under
test by only a few pH;
BNC Output: easy to plug directly in scope, data acquisition equipment, DVM or power
recorders;
USB interface Power Supply ,ease and flexibility to use;
Sound and LED alarm function, the design is more humanized;
Can be customized according to customer requirements, meet the test requirements
of special applications.
CP9000S Series: Has an extremely thin, clip-around Rogowski coil of typically 1.6mm
cross-section. Such a thin coil enables currents to be measured in the most difficult to
reach parts of a power Electronic converter with negligible disruption to the circuit
under test. It can be used in MOSFET or IGBT devices as small as TO-220 or TO-47. Cross
section only 4mm for 2kV isolation. Accuracy is ±2% of reading.
CP9000 Series probe: Cross section only 3.8mm typically, Safe Coil Voltage Isolation
2kVpk,Accuracy of ±2% of reading. It is ideal for monitoring currents in even the most
difficult to reach parts of a circuit.
CP900L Series probe: Cross section only 8mm typically, Safe Coil Voltage Isolation
10kVpk,Accuracy of ±1% of reading. It is ideal for power electronics development work
because it combines an easy to use thin, flexible, clip-around coil with an ability to
accurately replicate fast switching current waveforms be they sinusoidal, quasi-sinusoidal or
pulsed.
2. Application
MeasuringAC currents superimposed on large DC currents
Measuring capacitor ripple current
Monitoring current waveforms for semiconductor switches
Development and servicing of power electronic equipment
Monitoring currents in restricted places
Measuring fault currents or circuit breaker interruption currents
Measuring harmonic current components
Monitoring high frequency sinusoidal , pulsed or transient currents
Measuring signal or earth leakage currents in 3-phase supply systems
Switching current waveforms in MOSFET or IGBT devices as small as TO-220 or TO-47
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd.
3
3. Electrical Specifications
Measuring conditions:23℃;60%RH;with conductor central in the loop.
3.1 CP9000S Series
Model
Sensitivity
(mV/A)
Peak
Noise max
(mV Vpp)
Droop
typ.
(%/ms)
LF
bandwidth
-3dB(Hz)
HF
bandwidth
-3dB(MHz)
Accuracy
typ.
Insulation
voltage
Current
(kA)
di/dt
(kA/µS)
CP9003S
200
0.03
2
20
80
116
30
2%
1kV
CP9006S
100
0.06
4
20
65
67
30
CP9012S
50
0.12
8
15
35
34
30
CP9030S
20
0.3
20
15
9
9.2
30
CP9060S
10
0.6
40
10
6
6.2
30
CP9120S
5
1.2
70
10
3
3.2
30
CP9300S
2
3.0
70
5
2
2
30
CP9600S
1
6.0
70
5
2
2
30
3.2 CP9000 Series
Model
Sensitivity
(mV/A)
Peak
Noise
max
(mV Vpp)
Droop
typ.
(%/ms)
LF
bandwidth
-3dB(Hz)
HF
bandwidth
-3dB(MHz)
Accuracy
typ.
Insulation
voltage
Current
(kA)
di/dt
(kA/µS)
CP9012
50
0.12
0.8
3
70
80
12
2%
2kV
CP9030
20
0.3
2.0
5
40
50
12
CP9060
10
0.6
4.0
8
3
3.5
12
CP9120
5
1.2
8.0
14
0.9
1.0
12
CP9300
2
3.0
20
7
0.7
0.8
12
CP9600
1
6.0
25
5
0.5
0.6
12
CP9121
0.5
12
25
3.5
0.35
0.4
12
CP9301
0.2
30
25
3
0.2
0.2
12
CP9601
0.1
60
25
3
0.1
0.1
12
CP9122
0.05
120
25
3
0.06
0.05
12
3.3 CP9000L Series
Model
Sensitivity
(mV/A)
Peak
Noise
max
(mV Vpp)
Droop
typ.
(%/ms)
LF
bandwidth
-3dB(Hz)
HF
bandwidth
-3dB(MHz)
Accuracy
typ.
Insulation
voltage
Current
(kA)
di/dt
(kA/µS)
CP9012L
50
0.12
0.8
3
70
80
10
1%
10kV
CP9030L
20
0.3
2.0
2.5
40
50
10
CP9060L
10
0.6
4.0
8
3
3.5
10
CP9120L
5
1.2
8.0
14
0.9
1.0
10
CP9300L
2
3.0
20
7
0.7
0.8
10
CP9600L
1
6.0
40
5
0.5
0.6
10
CP9121L
0.5
12
40
3.5
0.35
0.4
10
CP9301L
0.2
30
40
3
0.2
0.2
10
CP9601L
0.1
60
40
3
0.1
0.1
10
CP9122L
0.05
120
40
3
0.06
0.05
10
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd.
4
3.4 CP9000(S/L) Series
Max. output voltage
±6Vpk
Terminal load
≥100kΩ
Power supply
USB 5V
Safety standard
EN61010-1:2010
EMC standard
EN61326-1:2013;EN61000-3-2:2014;EN61000-3-3:2013
4. Products and Accessories
4.1.1 CP9000S Products
Output Interface: standard BNC interface, connect to any manufacturer oscilloscope
with the BNC Cable.
Power indicator LED: When the power adapter is plugged ,the green LED lights.
Overload indicator LED: When the current measured exceed the range,the red LED
lights and the buzzer alarms.
Power plug: Standard USB (B) interface.
Cable : Standard 1m,Customized according to user needs.
Current probe direction: the current to the direction shown through, output is
positive, otherwise the output is negative.
Coil Diameter: 25mm typically.
Coil Cross Section: 1.6mm typically.
Coil Circumference:80mm typically
4.1.2 CP9000 Products
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd.
5
Output Interface: standard BNC interface, connect to any manufacturer oscilloscope
with the BNC Cable.Power indicator LED: When the power adapter is plugged ,the
green LED lights.
Overload indicator LED: When the current measured exceed the range, the red LED
lights and the buzzer alarms.
Power plug: Standard USB (B) interface.
Cable : Standard 1m,Customized according to user needs.
Current probe direction: the current to the direction shown through, output is
positive, otherwise the output is negative.
Coil Diameter:55mm typically.
Coil Cross Section: 3.8mm typically.
Coil Circumference:200mm typically.
4.1.3 CP9000L Products
Output BNC port : can connect to any brand oscilloscope with the BNC port.
Power indicator LED
Overload indicator LED: When the current measured exceed the range, the red LED
lights and the buzzer alarms.
Power plug: Standard USB (B) interface.
Cable : Standard 1m,Customized according to user needs.
Current probe direction: the current to the direction shown through, output is
positive, otherwise the output is negative.
Coil Diameter:150mm typically.
Coil Cross Section: 8mm typically.
Coil Circumference:600mm typically
4.2 Accessories
BNC Cable (CK-310:1m) USB Power Cable(AM-BM,1.5m)
Standard Accessory:USB Adaptor(USB Output:DC5V/1000mA)
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd.
6
5. Typical Mechanical Specifications
Type
CP9000S
CP9000
CP9000L
Coil circumference
80mm
200mm
600mm
Coil cross Section
1.6mm
3.8mm
8mm
Coil diameter
25mm
55mm
150mm
Cable length
1m
2m
4m
BNC cable
1m(standard accessory) ,2m(optional accessory)
Integrator box dimension
119*49*28mm
USB power cable(AM-BM)
1.5m
USB adaptor
59mm*30mm*20mm
Probe weight
153g
195g
377g
6. Environment Specifications
Operating temperature
Coil and cable
-20℃~100℃
Integrator box
0℃~50℃
Storage temperature
-30℃~70℃
Operating humidity
≤85%RH
Storage humidity
≤90%RH
7. Measurement Procedure
Have the power supply and oscilloscope ready for waveform measurement ready. The
oscilloscope set 1MΩ,and attenuation coefficient. According to the probe type. For
example ,CP9012:20X,CP9060:100X,CP9120:200X,CP9600:1000X.
Connect the USB Adaptor to the probe, the green power indicator light.
Connect the Coil Cross Section. Ensure the Coil Cross Section inserted in the
end part, or affect the measuring accuracy.
After measurement, disconnect the measured signal and Coil Cross Section.
Disconnect the power supply and preserve the probe.
8. Attentions
To ensure the measurement accurate, the measured wire should be through the center
of the probe loop.
The measurement has maximum error when the wire has put in the junction shadow
area of loop. Please avoid the area.
Ensure the Coil Cross tip has been inserted in the end part for high measuring
accuracy.
The shadow region has the maximum measurement error
CYBERTEK

Shenzhen Zhiyong Electronics Co., Ltd.
7
9. Care and Maintenance
Keep product surfaces clean and dry.
Be careful to avoid damaging the insulation surface while taking measurements.
Never attach the clamp to a circuit that operates at more than the maximum rated
voltage to earth.
Do not use it in a wet or dusty environment.
Do not use the probe, please put in the packaging, placed in a cool, clean and dry place.
Do not pulling the input lines and output lines ,avoid excessive twisting ,bending or
knot.
10. Service Strategy
According to the warranty card.
12. Packing List
List of goods
Name
Quantity
PROBE
1
USB Adapter( 5V/1A)
1
USB Cable(AM-BM)
1
BNC Cable(CK-310)
1
Tool Bag
1
Instruction Manual
1
Warranty Card
1
Test Report
1
BNC Cable(CK-320)
1 (optional accessory)
USB 5V Mobile Power
1 (optional accessory)
CYBERTEK
SHENZHEN ZHIYONG ELECTRONICS CO., LTD
Addr:RoomA1702, Building 4, TianAn Cyber Park, HuangGe North Road, LongGang
District, ShenZhen City, China
Tel: +86-400 852 0005
+86-755-86628000
Q Q: 400 852 0005
Fax: +86)0755-8662 0008
Email: cybertek@cybertek.cn ©Zhiyong Electronics, 2016
Url: http://www.cybertek.cn Published in China, May 16, 2016
CYBERTEK
This manual suits for next models
31
Table of contents
Other Cybertek Test Equipment manuals