Shenzhen Zhiyong Electronics Co., Ltd.
1. Summary
CP9000(S/L)Series are AC Flexible Current Probe .It has the advantages of
high bandwidth, high precision (typically 1%) characteristics. The frequency can be from
several Hz to tens of MHz, current ranges from mA level to kA level, which solves the
problem of current test.
The main features include:
easy to measure with thin ,flexible ,clip-around coil; Non-intrusive-loading the circuit under
test by only a few pH;
BNC Output: easy to plug directly in scope, data acquisition equipment, DVM or power
recorders;
USB interface Power Supply ,ease and flexibility to use;
Sound and LED alarm function, the design is more humanized;
Can be customized according to customer requirements, meet the test requirements
of special applications.
CP9000S Series: Has an extremely thin, clip-around Rogowski coil of typically 1.6mm
cross-section. Such a thin coil enables currents to be measured in the most difficult to
reach parts of a power Electronic converter with negligible disruption to the circuit
under test. It can be used in MOSFET or IGBT devices as small as TO-220 or TO-47. Cross
section only 4mm for 2kV isolation. Accuracy is ±2% of reading.
CP9000 Series probe: Cross section only 3.8mm typically, Safe Coil Voltage Isolation
2kVpk,Accuracy of ±2% of reading. It is ideal for monitoring currents in even the most
difficult to reach parts of a circuit.
CP900L Series probe: Cross section only 8mm typically, Safe Coil Voltage Isolation
10kVpk,Accuracy of ±1% of reading. It is ideal for power electronics development work
because it combines an easy to use thin, flexible, clip-around coil with an ability to
accurately replicate fast switching current waveforms be they sinusoidal, quasi-sinusoidal or
pulsed.
2. Application
MeasuringAC currents superimposed on large DC currents
Measuring capacitor ripple current
Monitoring current waveforms for semiconductor switches
Development and servicing of power electronic equipment
Monitoring currents in restricted places
Measuring fault currents or circuit breaker interruption currents
Measuring harmonic current components
Monitoring high frequency sinusoidal , pulsed or transient currents
Measuring signal or earth leakage currents in 3-phase supply systems
Switching current waveforms in MOSFET or IGBT devices as small as TO-220 or TO-47