PRODUCT IDENTIFICATION
3
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
D C C 240 60 3 B * * * A*
1 2 3 4, 5, 6 7, 8, 9 10 11 12 13 14 15 16
Brand
DDaikin Major & Minor
Configuration
C Co mmercial Package X No Options
A Non-powered convenience outlet
Application B Powered convenience outlet
CCooling C L ow Ambient Kit
GGasHeat D Return air smoke detector
HHeatPump E Supply air smoke detector
F Non-powered convenience outlet;
Low Ambient Kit
Nominal Gross Cooling Capacity G Non-powered convenience outlet;
036 3 Tons 102 8½ Tons Return air smoke detector
048 4 Tons 120 10 T ons H Non-powered convenience outlet;
060 5 Tons 150 12½ Ton s Supp ly air smoke detector
072 6 Tons 180 15 T ons J Non-powered convenience outlet;
090 7½ Ton s 24 0 20 T ons Return & Supply air smoke detectors
K Non-powered convenience outlet;
Nominal Heating Capacity Low-ambient kit; Su pply air smo ke detector
DCG DCC/DC
(Factory-Installed Electric Heat) L Non-powered convenience outlet;
045 45,000 BTU/h XXX No Heat Low Ambient Kit;
090 90,000 BTU/h 010 10 kW 030 30 kW Return & Supply air smoke detectors
115 115,000 BTU/h 015 15 kW 031 30 kW M Powered convenience outlet;
140 140,000 BTU/h 016 15 kW 045 45 kW Low Ambient Kit
210 210,000 BTU/h 018 18 kW 046 46 kW N Powered convenience outlet;
350 350,000 BTU/h 020 20 kW 060 60 kW Return air smoke detector
400 400,000 BTU/h 025 25 kW O Powered convenience outlet;
Return & Supply air smoke detectors
See product spe cifications for heat size(s) available for each capacity. P Powered convenience outlet;
Supp ly air smoke detector
Vol ta ge Q Powered convenience outlet;
1 208V 1-Phase 4 460V 3-Phase Low Ambient Kit;
3 208v 3-Phase 7 575V 3-Phaze Return air smoke dete ctor
R Powered convenience outlet;
Low Ambient Kit; Supp ly air smoke detector
T Powered convenience outlet;
Supply Fan/Drive Type/Motors Low Ambient Kit;
B Belt Drive V 2-Speed Belt Drive Return & Supply air smoke de tectors
DDirectDrive U Non-powered convenience outlet;
Low-ambient kit; Return air smoke detector
V Low Ambient Kit;
Factory-Installed Options Return air smoke detector
XNoOptions W Low A mbient Kit;
A Downflow Econ omizer Return & Supply air smoke detectors
H Disconnect Switch (non-fused) Y Low Ambient Kit;
J Do wn flow Economizer ; Disconnect Switch (non-fused) Return & Supply air smoke detectors
Z Return & Supply air smoke detectors
Factory-Installed Options
Note: Not all options available for all products. X Standard Aluminized Heat Exchanger
S S tainless Steel He at Exchanger
Factory-Installed Options
• Stainless-Steel Heat Exchanger (DCG units only): A tubular heat exchanger made of 409-type
stainless steel is installed in the unit.
• Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3-6 ton units, cooling operation is extended for 60ºF
ambient temperature to 35ºF outside air temperature. On 7½ to 20 ton units, cooling operation is extended from 35ºF ambient tem perature to 0ºF
outside air temperature.
• Economizers (Downflow): Based on air conditions, can provide outside air to cool the space.
• Electric Heat Kits (DCC and DCH units only): Available in all voltage options.
• Non-powered Convenience Outlet: A 120V,15A,GFCI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet.
• Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit; for use when unit is not running.
• Disconnect Switch (non-fused): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note
that for air conditioning (DCC units) and heat pump models (DCH units), the appropriate electric heat kit must be ordered to be factory-installed along
with the disc onnect switch (non-fused) when it is ordered. Please note that for models with a powered convenienc e outlet option and a disconnect switch
(non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position.
• Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit.
Factor y-Installed Options
Revi sion Leve ls