BD Controller
101N07xx Series
24 V DC
13
DEHC.PS.100.I1.02
4. Parameters
Parameter Group Parameter Description Default Max value Min value Step Unit Type
Main functions Main switch On/Off regulation of power supply to
controller OFF ON OFF 1
Battery
protection Battery cutout level Battery protection cut-out voltage
level 21.3 27 19 0.1 Volt Setting
Battery cutin diff. Voltage difference between battery
cut-in and cut-out 3.9 10 0.5 0.1 Volt Setting
Cutout delay Time to cut-out when non-critical
battery protection implemented 3 60 0 1 Seconds Setting
Cut-in level Calculated value.
Cutin=Cutout+Di. 0.1 Volt Measurement
Supply voltage Real-time voltage measured
on+&-terminals 0.1 Volt Measurement
Compressor Requested speed Compressor speed and therefore
capacity definition 4000 4000 2500 100 rpm Setting
Start delay Time to start after
compressor is switched ON 4 240 2 1 Seconds Setting
Start speed
Optional startup speed lower than
Requestedspeed,duringtheperiod
Start time.
2500 4000 2500 100 rpm Setting
Start time
Period of time elapsing after startup
of compressor until Requested speed
is reached
30 600 0 1 Seconds Setting
Compressor speed Real-time speed (+/- 10%) 1 rpm Measurement
Condenser fan Cond. Fan voltage Supply voltage to the
condenser fan. 24 31 12 1 Volt Setting
Fan speed Condenserfanspeedsynchronized
with compressor operation 100 100 40 10 % Setting
Fan start delay Time to start as a function of
Thermostat 0 240 0 1 Seconds Setting
Fan stop delay Time to stop as a function of
Thermostat 0 240 0 1 Seconds Setting
Fan forced ON Force condenser fan continuously
ON or OFF OFF ON OFF 1 Setting
Detect missing fan Detect whether condenser fan is
connected OFF ON OFF 1 Setting
Fan speed Real-time condenser fan speed 1 % Measurement
Evaporator fan Evap. Fan voltage Supply voltage to the evaporator fan. 24 31 12 1 Volt Setting
Fan speed
Evaporator fan speed
synchronizedwith
compressor operation.
100 100 40 10 % Setting
Fan start delay Time to fan start as a
function of Thermostat 0 240 0 1 Seconds Setting
Fan stop delay Time to fan stop as a
function of Thermostat 0 240 0 1 Seconds Setting
Fan forced ON Force evaporator fan
continuously ON or OFF OFF ON OFF 1 Setting
Detect missing fan Detect whether evaporator fan is
connected OFF ON OFF 1 Setting
Fan speed Real-time evaporator fan speed 1 % Measurement
The user can change settings and observe real-time measurements (read-only)
in the following parameters.
The table in 4.1 Parameter Overview is intended for easy reference.
For more detail, please refer to 4.2 Description of Parameter Groups.
4.1 Parameter
Overview