manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Danfoss
  6. •
  7. DC Drive
  8. •
  9. Danfoss VLT AutomationDrive FC 302 with Connectors User manual

Danfoss VLT AutomationDrive FC 302 with Connectors User manual

Other Danfoss DC Drive manuals

Danfoss VLT OneGearDrive User manual

Danfoss

Danfoss VLT OneGearDrive User manual

Danfoss VLT CDS 803 Guide

Danfoss

Danfoss VLT CDS 803 Guide

Danfoss VLT Midi Drive FC 280 Guide

Danfoss

Danfoss VLT Midi Drive FC 280 Guide

Danfoss VLT HVAC Drive Metasys N2 User manual

Danfoss

Danfoss VLT HVAC Drive Metasys N2 User manual

Danfoss VLT AQUA Drive FC 202 User manual

Danfoss

Danfoss VLT AQUA Drive FC 202 User manual

Danfoss VLT Micro Drive FC 51 Series Owner's manual

Danfoss

Danfoss VLT Micro Drive FC 51 Series Owner's manual

Danfoss VLT Decentral FCD 300 User manual

Danfoss

Danfoss VLT Decentral FCD 300 User manual

Danfoss VLT AutomationDrive FC 360 User manual

Danfoss

Danfoss VLT AutomationDrive FC 360 User manual

Danfoss VLT FC 300 User manual

Danfoss

Danfoss VLT FC 300 User manual

Danfoss VLT DriveMotor FCP 106 User manual

Danfoss

Danfoss VLT DriveMotor FCP 106 User manual

Danfoss VLT 4000 User manual

Danfoss

Danfoss VLT 4000 User manual

Danfoss ADAP-KOOL AKD 102 User manual

Danfoss

Danfoss ADAP-KOOL AKD 102 User manual

Danfoss VLT AQUA Drive FC 202 Guide

Danfoss

Danfoss VLT AQUA Drive FC 202 Guide

Danfoss vlt aqua User manual

Danfoss

Danfoss vlt aqua User manual

Danfoss VLT 6000 HVAC Series Guide

Danfoss

Danfoss VLT 6000 HVAC Series Guide

Danfoss VLT AutomationDrive FC 301 User manual

Danfoss

Danfoss VLT AutomationDrive FC 301 User manual

Danfoss VLT AQUA Drive FC 200 User manual

Danfoss

Danfoss VLT AQUA Drive FC 200 User manual

Danfoss 73691290 User manual

Danfoss

Danfoss 73691290 User manual

Danfoss VLT FC51 Guide

Danfoss

Danfoss VLT FC51 Guide

Danfoss VLT 2800 User manual

Danfoss

Danfoss VLT 2800 User manual

Danfoss CDS 803 User manual

Danfoss

Danfoss CDS 803 User manual

Danfoss VLT Active Front End AFE 302 User manual

Danfoss

Danfoss VLT Active Front End AFE 302 User manual

Danfoss vlt aqua User manual

Danfoss

Danfoss vlt aqua User manual

Danfoss vlt aqua User manual

Danfoss

Danfoss vlt aqua User manual

Popular DC Drive manuals by other brands

National Instruments NI MID-7604 user guide

National Instruments

National Instruments NI MID-7604 user guide

SOMFY Maestria WT Series instructions

SOMFY

SOMFY Maestria WT Series instructions

Trane TR150 Service manual

Trane

Trane TR150 Service manual

Chamberlain Garog D Series operating manual

Chamberlain Garog

Chamberlain Garog D Series operating manual

Parker PDS Series user guide

Parker

Parker PDS Series user guide

Binks QS-5012-1-CE Service manual

Binks

Binks QS-5012-1-CE Service manual

YASKAWA CANopen SI-S3 Technical manual

YASKAWA

YASKAWA CANopen SI-S3 Technical manual

GE D20A6 instructions

GE

GE D20A6 instructions

Lenze PositionServo 940 user manual

Lenze

Lenze PositionServo 940 user manual

Unex MC-D-250-1000-050W-TW operating manual

Unex

Unex MC-D-250-1000-050W-TW operating manual

Geckodrive G213V manual

Geckodrive

Geckodrive G213V manual

ABB RSYC-01 user manual

ABB

ABB RSYC-01 user manual

Rockwell Automation PowerFlex 700S Programming manual

Rockwell Automation

Rockwell Automation PowerFlex 700S Programming manual

WEG DeviceNet CFW500 user manual

WEG

WEG DeviceNet CFW500 user manual

Siemens SINAMICS G List manual

Siemens

Siemens SINAMICS G List manual

Siemens SINAMICS SM150 6SL3815-7NP41-0AA1 Operating instructions & installation instructions

Siemens

Siemens SINAMICS SM150 6SL3815-7NP41-0AA1 Operating instructions & installation instructions

SOMFY JR RU 30 instructions

SOMFY

SOMFY JR RU 30 instructions

Beckhoff AX8911 Documentation

Beckhoff

Beckhoff AX8911 Documentation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

NOTICE
VLT
®
AutomationDrive FC 302 with connectors is
NOT UL approved.
The ETR functionality is not guaranteed.
General rating: Enclosure IP55.
2 Safety Instructions
WARNING
DISCHARGE TIME
The frequency converter contains DC-link capacitors, which
can remain charged even when the frequency converter is
not powered. Failure to wait the specified time after power
has been removed before performing service or repair work,
could result in death or serious injury.
1. Stop the motor.
2. Disconnect AC mains, permanent magnet type
motors and remote DC-link power supplies,
including battery back-ups, UPS, and DC-link
connections to other frequency converters.
3. Wait for the capacitors to discharge fully, before
performing any service or repair work. The duration
of waiting time is specified in Table 2.1.
Voltage
[V]
Power range
[kW]
Minimum waiting
time (minutes)
3x400 0.55–7.5 4
High voltage can be present even when the warning LED indicator
lights are off.
Table 2.1 Discharge Time
3ItemsSupplied
Depending on the ordering number, the following is supplied:
FC 302 with connectors - 2 motor connectors (134N3195)
Illustration 3.1 2 Motor Connectors
Installation Instructions
VLT® AutomationDrive FC 302 with Connectors
Danfoss A/S © Rev. 06/2014 All rights reserved. MI04G102
FC 302 with connectors - 4 motor connectors (134N3196)
Illustration 3.2 4 Motor Connectors
FC 302 with connectors - side view
Illustration 3.3 Side View
For overall dimensions, refer to the VLT
®
AutomationDrive FC
302 Design Guide.
NOTICE
See the VLT
®
AutomationDrive FC 302 Design Guide for
further information.
4 Connectors
4.1 Overview
The frequency converter has 7 connectors plus 2 or 4 motor
connectors
Label Connector Description
X1 Mains Mains in M23 (in M25) Male
X2.1-X2.4 Motor Motor connection M23 Female
X51 PROFIBUS - Male PROFIBUS M12
X52
PROFIBUS -
Female PROFIBUS M12
X11-X14 I/O box connector Phoenix I/O box
Table 4.1 Connectors
4.2 X1- Mains M23 (in M25) Male
General ratings
•
Pins 1, 2, 3 and 4: 480 V AC, maximum 15 A
•
Pins C and D: 30 V DC, maximum 3 A
•
Tightening torque: 1.5–2.0 Nm
Pin Label Connected to frequency
converter wiring schematic
Min. wire
[mm
2
]
1L1 91(T1) 2.5
4L2 92(T2) 2.5
3L3 93(T3) 2.5
2PE 95(PE) 2.5
D 0 V DC 35 2.75
C 24 V DC 36 2.75
Table 4.2 Wire/Connector Assignment for Plug X1
Mating part: Mains X1 (female)
Phoenix order number.: KK-0885/XX,XX
Installation Instructions VLT® AutomationDrive FC 302 with Connectors
2
Danfoss A/S © Rev. 06/2014 All rights reserved. MI04G102
4.3 X2.1-X2.4 Motor Connectors M23 (in M25)
Female
General ratings
•
Pins 1, 2, 3 and 4: 480 V AC, maximum 15 A
•
Pins C and D: 30 V DC, maximum 3 A
•
Tightening torque: 1.5–2.0 Nm
Pin Label Connected to frequency
converter wiring schematic
Min. wire
[mm
2
]
1U 96(U) 2.5
3V 97(V) 2.5
4W 98(W) 2.5
2PE 95 2.5
Table 4.3 Wire/Connector Assignment for Plug X2
Mating part: Motor X2 (male)
Phoenix order number.: KCX-K0341/XX,XX
Max. cable length 7.0 m
4.4 2 Motor Connection Variant (134N3195)
Keep blind plugs installed at all times to keep the enclosure
tight.
Label Connected to frequency converter wiring schematic
X2.1-B 53
X2.2-A 50
X2.1-A and
X2.2-B Connected to a common terminal
X2.1-C and
X2.2-C
Connected to an open terminal available in the
frequency converter
X2.1-D and
X2.2-D
Connected to an open terminal available in the
frequency converter
Table 4.4 2 Motor Connection
4.5 4 Motor Connection Variant (134N3196)
Label Connected to frequency converter wiring schematic
X2.1-B 53
X2.4-A 50
X2.1-A and
X2.2-B Connected via an internal terminal
X2.2-A and
X2.3-B Connected via an internal terminal
X2.3-A and
X2.4-B Connected via an internal terminal
Table 4.5 4 Motor Connection
4.6 X51 PROFIBUS M12 Male, X52 PROFIBUS
M12 Female
General ratings
•
30 V DC, maximum 1 A
•
Tightening torque: 0.2–0.3 Nm
Label Connected to frequency converter PROFIBUS
connector
15VDC 67
2 63
30VDC 66
4 62
Table 4.6 PROFIBUS Connection
Mating part: PROFIBUS X52 and X51 (female/male)
Phoenix order number.: SAC-2P-MSB/ XX,XX-910/FSB SCO CT
4.7 X11-X14 I/O Connector Box
Phoenix sensor/actuator box - SACB-4/4-L-0,57HPUR CDA -
1531426
Tightening torque slot sensor/actuator cable 0.4 Nm
Label Wire Connected to frequency
converter wiring schematic
X11-X14 1 Brown 12 +24 V Out
X11-X14 2
X11-X14 3 Blue 20 COM D IN
X14-4 Grey 33 D IN
X13-4 Yellow 29 D IN/OUT
X12-4 Green 19 D IN
X11-4 White 18 D IN
Table 4.7 Connector Box
5 Installation
NOTICE
For installation, refer to the VLT
®
AutomationDrive FC 302
Operating Instructions.
Installation Instructions VLT® AutomationDrive FC 302 with Connectors
MI04G102 Danfoss A/S © Rev. 06/2014 All rights reserved.
3
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on
order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss
and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss A/S
Ulsnaes 1
DK-6300 Graasten
www.danfoss.com/drives
*MI04G102*
MI04G102130R0611 Rev. 06/2014