4
+ 1 HR
+ 2 HR
+ 3 HR
SETTING THE CLOCK
PressPROGtodisplay the timeofday(thedisplayblinks).PressDAY
(the display stops blinking) to select today (1 = Monday, 6 = Saturday
etc).Press and hold down the + or - button to change the time quickly
in ten minute steps, or press and release to change the time by one
minute.
When the day and time are correct, press and release PROG once to
start the clock and further press and release as necessary until the
colon starts blinking, (RUN mode.) The intermediate stages are
explained in the Setting Instructions.
WINTER TIME / SUMMER TIME CLOCK
When the clocks are changed from Summer Time to Winter Time (or
vicaversa) thereisnoneedtoalter theclockbyenteringprogramming
mode (i.e. pressing the PROG button). Instead just press and hold
down the - button to change from Summer Time to Winter Time or the
+ button to change from Winter Time to Summer Time. The first time
this is done (after a RESET) the clock is set and can only be changed
by one hour as appropriate.
Ifa mistakeismade,e.g.pressing the+buttonintheautumnwhenthe
-buttonshouldhavebeenpressed,rectifytheproblembypressingthe
correctbuttonandthenre-settingtheclockbyonehourasappropriate.
(Refer to SETTING THE CLOCK above).
TIME OR TEMPERATURE DISPLAY
The default display in RUN mode shows the time of day. This may be
changed to display the actual temperature being sensed by pressing
both COPY and NEXT buttons together. Return to time display by
pressing them together again.
THERMOSTAT MODE
The TP75 may be converted to control at a constant, user selected,
temperature by pressing and holding down the sand tbuttons until
thedisplaychangestothatshowninFig.6withthedefaulttemperature
of 8°C (or 46°F), which may be changed as required using the sor t
button. The unit will stay in thermostat mode until the sand tare
pressed together again.
FROST THERMOSTAT MODE
Whilst in thermostat mode the TP75 may be set to guard against
possiblefrost damagein areaswhere the unit (or its remote sensor) is
fitted. The control temperature may be set to a suitable level using the
sor tbuttons. The unit will stay in frost thermostat mode until the s
and tare pressed together again.
HOLIDAY MODE
Whilst in thermostat mode pressing the DAY button will activate the
holiday mode. The display will change to that shown in Fig. 7 with a
number indicating the default holiday period of 00 days. Use the sor
tbuttons to adjust the control temperature as required, and use the
+ or - buttons to set the number of days required, in the range 1-99
days. Ifthenumberofdaysisleftat00thentheunitwillreturntonormal
at event 1 the following day. When the selected number of days have
elapsed the unit will automatically return to normal, controlling
temperatures to the set programme.
Fig. 4. Clock time ready for
changing. (Colon steady,
digits blinking).
+ 1 HR
+ 2 HR
+ 3 HR
Fig. 5.
Temperature Display.
(Room temperature is
below the set temperature,
so the boiler is firing)
+ 1 HR
+ 2 HR
+ 3 HR
Fig. 6. Thermostat mode.
+ 1 HR
+ 2 HR
+ 3 HR Fig. 7.
Holiday mode.
HOLIDAY MODE Continued.
Control may also be restored to normal by pressing the sand t
together.
USER OVERRIDES
Whilst the unit is operating normally in RUN mode the following
overrides are available:
TEMPERATURE SETTING OVERRIDE
Press sto increase or t to decrease the current set temperature.
Each press will change the temperature setting by 0.5°C (or 1°F). To
make larger changes press the button and hold it down.
/ OVERRIDE
With (profiled)selectedtemperaturecontrolwillfollowthe
programme.
With (allday)selected the temperatureset for Event 1 will
be maintained until Event 6. During this "ALLDAY" period the
programmed temperature may be overriden as above.
+1 HR/+2 HR/+3 HR OVERRIDE
Pressing this button once causes the current control temperature to
last for an extra hour. Press it twice for an extra 2 hours, and three
times for 3 hours. Pressing a fourth time will remove the override.
For example, a comfort temperature of 21°C programmed to end at
22:30 could be extended passed midnight. Alternatively, a morning
set-back temperature of 15°C could be extended to effectively cancel
a midday comfort setting.
BATTERY MAINTENANCE
Only good quality alkaline batteries should be used.
New batteries will provide the power for switching the outputs on and
off for approximately 2 years. When the batteries volts fall to the
minimumlevelneededtomaintainoperationabatterysymbolwillblink
in the display. When this symbol appears both batteries should be
replaced with high quality alkaline cells. Operation will continue
normally until the 15th midnight after the symbol started blinking and
thentheunitwill switch off alloutputs,andshut down with justthetime
and the blinking battery displayed. Whilst the battery symbol is still
blinking, the old batteries may be removed and new batteries placed
in the sleeve provided and inserted within one minute. Internal
circuitry will maintain the user set programme memory during this
period.
+ 1 HR
+ 2 HR
+ 3 HR Fig. 8 Temperature
overridden - boiler firing.
+ 1 HR
+ 2 HR
+ 3 HR Fig. 9.
Allday selected - event 1
temperature active.
+ 1 HR
+ 2 HR
+ 3 HR Fig. 10.
Current temperature
extended by 2 hours.
+ 1 HR
+ 2 HR
+ 3 HR Fig. 11.
Blinking battery symbol,
change batteries.
Danfoss Randall Ltd. continually strives to improve its
productsandreserves the right to change designs and
specifications without notice.
Part No: 8953 Iss 9 12/01
Danfoss Randall Limited
Ampthill Road
Bedford, MK42 9ER
Tel: (01234) 364621
Fax: (01234) 219705