Operating instruction Cawi lock 7205
Even though using this lock system is very easy, please read
these operang instrucons carefully and completely before
using the lock; this will help to avoid operang errors. These
instrucons refer to an electronic lock installed in a high-
security container such as a safe. The green LED will blink to
conrm each keypad entry. The me period between any two
entries may not exceed 20 seconds as otherwise all previous
entries will be cleared. The keypad could be supplied with two
dierend keypad prints.
1. Input of numerical acces code
for example: 3 2 7 9 6 1
2. Input of alpha-numeric acces code e.g. ROLF12
For example: 8 7 5 3 1 2
Cawi electronic
lock 7205
General Closing the electronic lock
Opening the electronic lock
Enter the six-digit combinaon set at the factory by pressing
buons 1 – 2 – 3 – 4 – 5 – 6 or enter your own six-digit
combinaon.
Please note: Press the C buon to correct your entry; in this case
the enre combinaon will have to be entered again. The green
LED will light for about 6 seconds to indicate that the lock has
been cleared for opening. At the same me, the electronic lock
will clear the mechanism for opening. The door to the safe can
now be unlocked with the keypad lever and opened using the
ngerp grip. The electronic locking element is then locked again
automacally aer about 6 seconds; this is indicated by the red
and green LEDs blinking once. The electronic lock is only secured
when the keypad lever is moved manually into its locked
posion.
Close the door to the safe and return the keypad lever to its locked
posion, moving it all the way to the mechanical stop. The red cap
must be completely concealed by the keypad lever. The green LED
goes out at the same me to indicate that the electronic lock has
been mechanically secured in this posion.
Please note: Try to operate the keypad lever to verify that the
container is closed correctly and securely.
Response to erroneous entries
If you press the C buon during the entry sequence, then the
enre series of digits previously entered will be cancelled. If a
programming phase has been iniated, then the lock will exit the
programming mode; you must re-start programming from the
very beginning by pressing the * buon.
Excepon: The me-out period following erroneous entries and
the low-baery warning period cannot be interrupted by
pressing the C buon.
The red LED lights for about 3 seconds whenever an invalid
combinaon is entered. The combinaon may now be entered
again. Aer the third consecuve incorrect entry, however, a 10-
second me-out period starts; the keypad will accept no entries
during this period. This me-out period will be extended by 10
seconds following each subsequent incorrect entry. The me-out
periods cannot be interrupted with the ”C” buon.
Correction with the C button