Deif MDR-2 User manual

QUICK START GUIDE
QUICK START GUIDE
•What’s in the delivery?
•Getting started
•The first steps
•PC utility software
Document no.: 4189340624B
SW version 3.0X.X or later
Multi Differential Relay, MDR-2

MDR-2 Quick Start Guide
DEIF A/S Page 2 of 16
Table of contents
1. ABOUT THIS DOCUMENT ................................................................................................... 3
GENERAL PURPOSE...................................................................................................................... 3
INTENDED USERS ......................................................................................................................... 3
CONTENTS/OVERALL STRUCTURE..................................................................................................3
2. WARNINGS AND LEGAL INFORMATION........................................................................... 4
LEGAL INFORMATION AND RESPONSIBILITY.....................................................................................4
ELECTROSTATIC DISCHARGE AWARENESS .....................................................................................4
SAFETY ISSUES............................................................................................................................4
DEFINITIONS ................................................................................................................................4
3. WHAT’S IN THE DELIVERY?............................................................................................... 5
STANDARD DELIVERY....................................................................................................................5
OPTIONAL DELIVERY..................................................................................................................... 6
4. GETTING STARTED ............................................................................................................. 7
CONNECTING THE DEVICES...........................................................................................................7
BASIC WIRING............................................................................................................................... 8
5. THE FIRST STEPS..............................................................................................................11
BASIC AC VALUES......................................................................................................................11
6. PC UTILITY SOFTWARE....................................................................................................13
INSTALLATION ............................................................................................................................ 13
GETTING CONNECTED TO THE UNIT .............................................................................................14
READ PARAMETERS FROM THE DEVICE ........................................................................................15
BASIC CONFIGURATION OF A DEVICE USING THE UTILITY SOFTWARE ..............................................16

MDR-2 Quick Start Guide
DEIF A/S Page 3 of 16
1. About this document
General purpose
This document is the Quick Start Guide for the Multi-line 2 product MDR-2. The general purpose
of the document is to help the user with the first steps of installing and using the unit.
Intended users
This Quick Start Guide is mainly intended for the panel builder in charge. On the basis of this
document, the panel builder designer will give the electrician the information he needs in order
to get started to install the unit. For detailed electrical drawings, the Designer’s Reference
Handbook must be used.
Contents/overall structure
This document is divided into chapters, and in order to make the structure simple and easy to
use, each chapter will begin from the top of a new page.
Please make sure that you also read the Designer’s Reference Handbook
before starting to work with the Multi-line 2 controller and the gen-set to be
controlled. Failure to do this could result in human injury or damage to the
equipment.

MDR-2 Quick Start Guide
DEIF A/S Page 4 of 16
2. Warnings and legal information
This chapter includes important information about general legal issues relevant in the handling
of DEIF products. Furthermore, some overall safety precautions will be introduced and
recommended. Finally, the highlighted notes and warnings, which will be used throughout this
document, are presented.
Legal information and responsibility
DEIF takes no responsibility for installation or operation of the generator set. If there is any
doubt about how to install or operate the generator controlled by the unit, the company
responsible for the installation or the operation of the set must be contacted.
Electrostatic discharge awareness
Sufficient care must be taken to protect the terminals against static discharges during the
installation. Once the unit is installed and connected, these precautions are no longer
necessary.
Safety issues
Installing the unit implies work with dangerous currents and voltages. Therefore, the installation
of the unit should only be carried out by authorised personnel who understand the risks involved
in the working with live electrical equipment.
Definitions
Throughout this document a number of notes with helpful user information will be presented. To
ensure that these are noticed, they will be highlighted in order to separate them from the
general text.
Note symbol
Warnings
Be aware of the hazardous live currents and voltages. Do not touch any AC
measurement inputs as this could lead to injury or death.
The notes provide general information which will be helpful for the reader to
bear in mind.
The warnings indicate a potentially dangerous situation which could result in
death, personal injury or damaged equipment if certain guidelines are not
followed.
The units are not to be opened by unauthorised personnel. If opened anyway, the
warranty will be lost.

MDR-2 Quick Start Guide
DEIF A/S Page 5 of 16
3. What’s in the delivery?
Standard delivery
The main unit
Standard display unit, DU-2

MDR-2 Quick Start Guide
DEIF A/S Page 6 of 16
Optional delivery
Display cable, 3 m (option J1)
Display cable, 6 m (option J2)
Display cable, 1 m (option J6)

MDR-2 Quick Start Guide
DEIF A/S Page 7 of 16
4. Getting started
Connecting the devices
Connecting the display to the main unit
Connect the SUB-D display cable to the main unit and the display unit as shown in the below
picture.

MDR-2 Quick Start Guide
DEIF A/S Page 8 of 16
Basic wiring
AC wiring

MDR-2 Quick Start Guide
DEIF A/S Page 9 of 16
AC wiring – option C4
Only -/1A CTs can be used with option C4.

MDR-2 Quick Start Guide
DEIF A/S Page 10 of 16
DC wiring

MDR-2 Quick Start Guide
DEIF A/S Page 11 of 16
5. The first steps
Basic AC values
This chapter guides you through the most essential parameters which have to be adjusted
before you can start using the unit.
The setpoints can either be adjusted from the display unit or by using the DEIF utility software.
The following examples will show how to adjust the parameters from the display unit.
All settings are reached by placing the cursor under SETUP (in the main page) and pressing
ENTER .
Place the cursor under SYST and press ENTER .

MDR-2 Quick Start Guide
DEIF A/S Page 12 of 16
Place the cursor under the setting you require and press ENTER .
Nominal settings
No.
Setting
Min.
Max.
Factory
setting
Notes
Ref.
Description
4010 Nominal settings
4011 Nom. settings Frequency
48.0 Hz
62.0 Hz
50.0 Hz
Designer’s
Reference
Handbook
4012 Nom. settings Current
1 A
10000 A
787 A
To adjust the transformer settings, use the or push-button to get to the transformer
page.
VT and CT settings
No.
Setting
Min.
Max.
Factory
setting
Notes
Ref.
Description
4020 Transformer
6041 Transformer
Current
primary
5 A
10000 A
1000 A
Designer’s
Reference
Handbook
6043 Transformer
Current
secondary
1 A
5 A
1 A

MDR-2 Quick Start Guide
DEIF A/S Page 13 of 16
6. PC utility software
Installation
1. Go to www.deif.com
2. Select “Download centre”
3. Select “Software download”
4. Select “Multi-line 2 Utility Software v.1.x” in the dropdown list
5. Fill in your e-mail address and click “Submit”.
Subsequently, you will receive an e-mail containing a link. Click the link and follow the
instructions to install the programme.

MDR-2 Quick Start Guide
DEIF A/S Page 14 of 16
Getting connected to the unit
Connect the service port to the RS232 serial port on the computer (option J3 required).
Click the “Utility Software 1” icon on the desktop or in the Windows Start menu.
Desktop icon: Quick launch and Start menu icon:
The below window appears.
Check the COM-port
used for communication,
and make sure the
settings correspond to
the application settings.
Open the application
settings by clicking this
icon:
To start communica-
ting with the device,
click the “Connect
icon”:

MDR-2 Quick Start Guide
DEIF A/S Page 15 of 16
Read parameters from the device
The following screen will appear:
Select “Yes”’ to start the parameter transfer.
After retrieving all the parameters, the device is ready to be configured.
Open the Parameter list
Click the “Upload
parameters” icon

MDR-2 Quick Start Guide
DEIF A/S Page 16 of 16
Basic configuration of a device using the utility software
When the parameters have been uploaded, the screen will look like below:
Nominal frequency
Double-click menu 4011 “Nom. Frequency” and the below pop-up will appear:
The nominal frequency has now been changed and downloaded to the device.
Use the same procedure to adjust nominal current (menu 4012) and CT ratio (menu 4021 and
4022).
DEIF A/S reserves the right to change any of the above.
Click this or use the
slide bar to adjust the
nominal frequency.
After adjusting the fre-
quency, click “Write”
and “OK”.
For information about additional settings, please refer to the “Designer´s
Reference Handbook”, document no. 4189340300.
Table of contents
Other Deif Relay manuals