4Information Update
LCD Status Messages Update
Table 1-2 lists updates to the LCD status messages that can occur and the probable cause for each
message. The LCD messages refer to events recorded in the system event log (SEL). For information on
the SEL and configuring system management settings, see your systems management software
documentation.
NOTE: Each diagnostic LCD message is assigned a priority. The highest priority messages will supersede
any group of messages with a lower priority.
Table 1-1. System Messages
Message Causes Corrective Actions
The FBD link to the
following DIMM failed
to train: DIMM x
FBD training error -
The following memory
branch has been disabled:
Branch x
An error has occurred on the
FBD channel that contains the
specified DIMM. A fault is
indicated on the link adjacent
to the DIMM caused by a faulty
condition in either the specified
DIMM, the next DIMM in the
channel, or possibly the system
board. When this error occurs,
the other FBD branch in the
memory pair is disabled,
resulting in the second error
message.
Reseat all of the DIMMs on the
indicated FBD channel. See
"Memory" in the Hardware Owner’s
Manual for information about the
FBD branches and channels. See
"Troubleshooting System Memory" in
the Hardware Owner’s Manual. If the
problem persists, see "Getting Help"
in the Hardware Owner’s Manual.
Table 1-2. LCD Status Messages
Code Text Causes Corrective Actions
E1118 CPU Temp Interface The BMC is unable to determine
the CPU(s) temperature status.
Consequently, the BMC increases
the CPU fan speed to maximum
as a precautionary measure.
Turn off power to the system
and restart the system. If the
problem persists, see "Getting
Help" in the Hardware Owner’s
Manual.
E122B 0.9 V Over Voltage 0.9 V regulator voltage has exceeded
the allowable voltage range.
See "Getting Help" in the
Hardware Owner’s Manual.
E122C CPU Power Fault A voltage regulator failure was detected
when the processor regulator(s) was
enabled.
See "Getting Help" in the
Hardware Owner’s Manual.