MODEL:
GBR80LED
Page 1.
Part name
Appearance
Quantity
Grille
1
Fan
1
Housing
1
Duct
Connector
(4”)
1
4
INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN/LED LIGHT
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
1.
Make sure that the electric service supply
voltage is AC 120V, 60Hz.
2.
Follow all local electrical and safety codes, as
well as the National Electrical Code (NEC) and
the Occupational Safety and Health Act (OSH
Act).
3.
Always disconnect the power source before
working on or near the ventilating fan, motor or
junction box.
4.
Protect the power cord from sharp edges, oil,
grease, hot surfaces, chemicals or other objects.
5.
Do not kink the power cord.
6.
Do not install the unit where ducts are
configured as shown in Fig. A.
7.
Provide suction parts with proper ventilation.
8.
This unit is UL listed for use over a bathtub or
shower when installed in a GFCI protected
branch circuit.
9.
These ventilating fans are intended for
residential usage only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
1.
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
2.
Before servicing or cleaning unit, switch power
off at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
securely fasten a prominent warning device,
such as a tag, to the service panel.
3.
Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.
4.
Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the
American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE) and the
local code authorities.
5.
When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
6.
Ducted fans must always be vented to the
outdoors.
7.
If this unit is to be installed over a tub or shower,
it must be marked as appropriate for the
10. Not to be installed in a ceiling thermally insulated
to a value greater than R40. (This is required for
installation in Canada only).
Fig. A
CAUTION
1.
For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
2.
Not for use in cooking areas. (Fig. B)
3.
This product must properly connect to the
grounding conductor of the supply circuit.
4.
To reduce the risk of injury to persons, install the
fan at least 7 feet (2.1m) above the floor.
Fig. B
SUPPLIED ACCESSORIES
1. INSTALLATIONS
MOUNT HOUSING W ITH FLANGE:
1-1. To bend the housing tabs out to 90 degrees and
make housing tabs contact the bottom of the
joist.
1-2. The housing mounts with 4 screws (ø4×25).
Screw housing to joist through lowest holes in
each mounting flange, then through the other
holes.
USING SUSPENSION BRACKETS (SOLD
SEPARATELY)
1-3. Sliding suspension brackets available to allow
for your specific positioning of housing
anywhere between joists and span up to 24”.
1-4. Insert suspension brackets into the channels on
housing. Make sure tabs face “up” shown.
1-5. Extend suspension brackets to the width of the
joists. Hold fan in place with the suspension
brackets tabs wrapping around the bottom of
joist.
1-6. Fasten suspension brackets to joists with nails
or screws through holes near nails.
1-7. Secure suspension brackets together with
screws.
application and be connected to a GFCI (Ground
Fault Circuit Interrupter) – protected branch
circuit.
8.
Do not use this unit with any other solid-state
control devices. Solid-state control devices may
cause harmonic distortion, which can cause a
motor humming noise.
9.
NEVER place a switch where it can be reached
from a tub or shower.
Screw
(ø4×25)
Turning angle too large Duct shrink
Too many elbows Elbow near the body
Body
45°
Cooking area
45°
Do not install above or
inside this area
Cooking
Equipment oor
Screw
Joist
Ø4×25
Channel
Suspension Bracket
Sold separately)
Tab Face
Joist
Joist
Bottom of Joist
Screw
Tabs
Joist
MODEL:
GBR80LED
Page 2.
Model No.
Voltage
(V)
Frequen
cy
(Hz) Power
@ 0.1SP
(W )
Air Flow
@ 0.1SP
(CFM)
Weight
(lb.)
Power
@
0.0SP
(W )
GBR80LED
120
60
11.6
80
6.1
10.0
2. DUCT CONNECTION
2-1. Insert the duct(not provided) into the duct
connector and tape all ductworks connection to
make them secure and air tight.
2-2. Install the duct with a gradient 1°~2° to the
outside.
Inside
Outside
Duct Connector
Tape
3. Do not soak resin parts in water over 60°C.
CLEANING:
1.
Pull down the spring to remove grille.
2.
Clean grille. (Use non-abrasive kitchen
detergent, wipe dry with new cloth.)
3.
Use a cloth dampened with non-abrasive
kitchen detergent, remove dust and dirt from
ventilating fan. W ipe dry with new cloth.
4.
Replace grille.
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED
WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants
to the original consumer purchaser in the USA that
the Breez ventilation fan products will be free from
defects in material or workmanship. This warranty
is limited to three (3) years from the original date of
purchase.
Ceiling
Body
Grille
Duct
Gradient
1°~2°
DIMENSIONS
Limitations and Exclusions
1.
During the warranty period, a replacement for
any defective product will be supplied free of
charge for installation by the consumer. The
warranty provided herein does not cover charges
for labor or other costs incurred in the
troubleshooting, repair, removal, and installation
service.
3. CONNECT WIRING
3-1. Follow all local electrical and ANSI/NFPA70.
3-2. NEVER place a switch where it can be reached
from a tub or shower.
2.
All returns of defective parts or products must
include the product model number, and must be
made through an authorized Delta Electronics
distributor. Authorized returns must be shipped
prepaid. Repaired or replacement products will
be shipped by Delta Electronics F.O.B. shipping
point.
3.
Delta Electronics shall not be liable for any
indirect, incidental, consequential, punitive, or
special damages arising out of or in connection
with products use or performance, regardless of
the form of action whether in contract, tort
(including negligence), strict product liability or
otherwise.
4.
This warranty does not extend to fluorescent
lamp starters and tubes.
3-3. Connect wires as shown in wiring diagrams.
3-4. Use wire nuts (not provided) and connect house
power cable to ventilating fan.
3-5. 14 AWG (2.1 mm2) is the smallest conductor that
shall be used for branch-circuit wiring.
4. TEST RUN & GRILLE ATTACHMENT
4-1. Insert the LED lighting connecting into the power
socket of main body as below shown.
4-2. When the power on, check for abnormal
vibration or sound.
4-3. Insert the mounting springs into the slots and
mount the grille to the fan unit.
Lighting Connector
SPECIFICATIONS-FAN
Note: Design and specifications subject to change without notice.
SPECIFICATIONS-LED LIGHT ENGINE
ITEM SPEC.
DIMENSION(INCH)8L×4.4W×1.4H
POWER CONSUMPTION(W)11
CORRELATED COLOR
TEMPERATURE (K) 2700
LIGHT SOURCE LIFE(HOURS)30000(MIN.)
TRANSIENT PROTECTION CLASS A
OPERATING FREQUENCY(HZ)120
FCC QUALIFIED YES
ENERGY QUALIFIED YES
5.
The warranty does not cover if user does not
comply with manufacture’s installation manual.
6.
To qualify for warranty service, you must notify
Delta Electronics at the address or telephone
number below.
7.
Delta Electronics shall have no liability to the
original owner-user with respect to any defect
caused by abuse, misuse, neglect, improper
transportation or storage, improper testing,
improper installation, improper operation,
improper use, improper maintenance, improper
repair, improper alteration, improper
modification, tampering or accident of products
or parts thereof, or unusual deterioration or
degradation of products or parts thereof due to a
physical environment beyond the requirements
of products’ specifications.
Address: 4405 Cushing Parkway,
Fremont, CA
94538
US Toll Free Number: 1-888-979-9889
ROHS QUALIFIED YES
SAFETY REQUIREMENTS UL/cUL
5. OPERATION
5-1. Turn on the power switch to operate ON or OFF,
and LED indicator is green.
6. MAINTENANCE
WARNING:
Disconnect power source before working on unit.
Routine maintenance must be done every year.
CAUTION:
1.
Never use gasoline, benzene, thinner or any
other such chemicals for cleaning the ventilating
fan.
2.
Do not allow water to enter motor.
(BLK)
FANWHTBLK
FAN
SWITCH
BLK
WHT
GRD
LIGHT/FAN ELECTRICAL BOX
LINE
IN
HOUSE ELECTRICAL BOX
(BLUE)
LIGHT WHTBLU
LIGHT
SWITCH
Spring
Slots
Grille
8"
8.25"
5 .7 5 "
10.75"
10.75"
4" DUCT
10.75"
10.75" 8.25"
5.75"
0.84”

Other Delta Fan manuals

Delta AirEye Ion User manual

Delta

Delta AirEye Ion User manual

Delta VFA15ADTH2 User manual

Delta

Delta VFA15ADTH2 User manual

Delta BreezSlim SLM70-LVDC User manual

Delta

Delta BreezSlim SLM70-LVDC User manual

Delta breez VFB25ACH User manual

Delta

Delta breez VFB25ACH User manual

Delta VFB080C4A1 User manual

Delta

Delta VFB080C4A1 User manual

Delta Breez Slim SLM70ELED User manual

Delta

Delta Breez Slim SLM70ELED User manual

Delta BreezRadiance RAD110LED User manual

Delta

Delta BreezRadiance RAD110LED User manual

Delta BreezIntegrity ITG80 User manual

Delta

Delta BreezIntegrity ITG80 User manual

Delta BreezGreenBuilder GBR80LED User manual

Delta

Delta BreezGreenBuilder GBR80LED User manual

Delta Breez VFB70F User manual

Delta

Delta Breez VFB70F User manual

Delta Breez Integrity ITG50LED User manual

Delta

Delta Breez Integrity ITG50LED User manual

Delta VFB32AGTH User manual

Delta

Delta VFB32AGTH User manual

Delta 110HLEDNL User manual

Delta

Delta 110HLEDNL User manual

Delta HEF070A Series User manual

Delta

Delta HEF070A Series User manual

Delta VFB080D4H1 User manual

Delta

Delta VFB080D4H1 User manual

Delta breez SMT130 User manual

Delta

Delta breez SMT130 User manual

Delta ITG70BT User manual

Delta

Delta ITG70BT User manual

Delta breez Smart SMT150-200 User manual

Delta

Delta breez Smart SMT150-200 User manual

Delta VFB17AXTH User manual

Delta

Delta VFB17AXTH User manual

Delta Breez GreenBuilder GBR100LED-DECOR User manual

Delta

Delta Breez GreenBuilder GBR100LED-DECOR User manual

Delta breez Integrity ITG80 User manual

Delta

Delta breez Integrity ITG80 User manual

Delta Breez GreenBuilder GBR50 User manual

Delta

Delta Breez GreenBuilder GBR50 User manual

Delta GBR80HL User manual

Delta

Delta GBR80HL User manual

Delta SH-FT02 User manual

Delta

Delta SH-FT02 User manual

Popular Fan manuals by other brands

Ebmpapst W4E300-ZB02-01 operating instructions

Ebmpapst

Ebmpapst W4E300-ZB02-01 operating instructions

Water-Loo LCS-F Operating and maintenance

Water-Loo

Water-Loo LCS-F Operating and maintenance

EWT OSCILLOR 40 CHROME user manual

EWT

EWT OSCILLOR 40 CHROME user manual

Ebmpapst W2E250-CB05-51 operating instructions

Ebmpapst

Ebmpapst W2E250-CB05-51 operating instructions

System air SAVE VSR 150/B Installation and service

System air

System air SAVE VSR 150/B Installation and service

Oriental motor MF Series operating manual

Oriental motor

Oriental motor MF Series operating manual

Ebmpapst W2G115-AG71-12 operating instructions

Ebmpapst

Ebmpapst W2G115-AG71-12 operating instructions

Suntec Wellness Klimatronic CoolBreeze 9.500 Tri-Vario TV+ user manual

Suntec Wellness

Suntec Wellness Klimatronic CoolBreeze 9.500 Tri-Vario TV+ user manual

Ebmpapst A2D210-AB10-05 operating instructions

Ebmpapst

Ebmpapst A2D210-AB10-05 operating instructions

ZIEHL-ABEGG ECBLUE MODBUS Assembly instructions

ZIEHL-ABEGG

ZIEHL-ABEGG ECBLUE MODBUS Assembly instructions

Beko EFW5000WS user manual

Beko

Beko EFW5000WS user manual

Nicotra EC FAN FDP operating manual

Nicotra

Nicotra EC FAN FDP operating manual

Mitsubishi Electric LGF-100GX-E installation instructions

Mitsubishi Electric

Mitsubishi Electric LGF-100GX-E installation instructions

Greenheck SP110 Installation, operation and maintanance manual

Greenheck

Greenheck SP110 Installation, operation and maintanance manual

Hunter Ventura 81004 Parts guide

Hunter

Hunter Ventura 81004 Parts guide

Honeywell HYF1101E4 User instructions

Honeywell

Honeywell HYF1101E4 User instructions

Monte Carlo Fan Company 5HLR54 Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 5HLR54 Series Owner's guide and installation manual

Kendal Lighting AC-23960 installation instructions

Kendal Lighting

Kendal Lighting AC-23960 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.