manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Delta
  6. •
  7. Fan
  8. •
  9. Delta breez Integrity ITG80 User manual

Delta breez Integrity ITG80 User manual

INSTALLATION AND OPERATING INSTRUCTIONS
CEILING/WALL VENTILATION FAN –
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Make sure that the electric service supply voltage is AC
120V, 60Hz.
2. Follow all local electrical and safety codes, as well as
the National Electrical Code (NEC) and the Occupation
al Safety and Healthy Act (OSHAct).
3. Always disconnect the power source before working
on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease,
hot surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are congured as
shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit. 1. For General Ventilating Use Only. Do Not Use To
Exhaust Hazardous Or Explosive Materials And Vapors.
2. Not for use in cooking area. (Fig. B)
3. This product must properly connect to the grounding
conductor of the supply circuit.
4. To reduce the risk of injury to persons, install the fan at
least 8.2 feet (2.5m) above the oor.
1. Single Speed Model: ITG80
Single speed control mode: Turn the power switch to
operate ON/OFF.
1. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
2. Before servicing or cleaning the unit, switch power o
at service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualied person(s) in accordance with all applicable
codes and standards, including re-rated construction.
4. Sucient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of fuel
burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guideline and
safety standards such as those published by the National
Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application and
be connected to a GFCI (Ground Fault Circuit
Interrupter) – protected branch circuit.
8. Do not use this unit with any other solid-state control
device. Solid-state controls devices may cause harmonic
distortion, which can cause a motor humming noise.
9. NEVER place a switch where it can be reached from a
tub or shower.
10. Not to be installed in a ceiling thermally insulated to a
value greater than R40. (This is required for installation
in Canada only).
CAUTION
SUPPLIED ACCESSORIES
Part name
Appearance Quantity
Grille
1
Fan
1
Housing
1
4” Duct
1
Screw
(M4x12)
3
45
o
Cooking area
45
o
Do not install above or
inside this area
Cooking
Equipmentfloor
Fig. B
DIMENSIONS
SPECIFICATIONS
Note: Design and specications are subject to change
without notice.
Operation
MAINTENANCE WARNING:
Disconnect the power source before working on the
unit. Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any
other such chemicals for cleaning the
ventilating fan.
2. Do not allow water to enter the motor.
3. Do not soak resin parts in water over 60°C (140oF).
CLEANING
1. Pull down the spring to remove the grille.
2. Wash and clean the grille. (Use non-abrasive
kitchen detergent and wipe dry with a new
cloth.)
3. Remove dust and dirt from the ventilating fan
using a vacuum cleaner.
4. Using a cloth dampened with kitchen detergent,
remove any dirt from the ventilating fan. Wipe
dry with a new cloth.
5. Replace the grille.
Model No. Voltage
(V)
Frequency
(Hz)
Power
(W)
Air Flow
@ 0.1SP
(CFM)
Weight
(lb.) Note
ITG80 120
60 12
80
4.0
Single
Speed
Turning angle too large Duct shrink
Too many elbows Elbow near the body
Body
Fig. A
Page 1.
MODEL: ITG80
5.75
1. Remove motor plate from housing by removing three
screws. (Fig. C)
2. Remove wiring cover from housing by pulling straight
out. Choose a hole and use a slotted screwdriver to
remove it. (Fig. D)
3. Follow all local electrical and safety codes. NEVER place
a switch where it can be reached from a tub or shower.
Connect wires as shown in wiring diagrams. (Fig. E)
4. Using wire nuts(not provided), connect house power
cable to ventilating fan wires. 14 AWG (2.1 mm2) is the
smallest conductor that shall be used for branch-cir
cuit wiring. (Fig. F)
5. Insert the duct into the duct connector and tape all
ductworks connection to make them secure and
airtight. Install the duct with a gradient 1°~2°to the
outside. (Fig. G)
6. New installation prior to nishing the ceiling: Insert the
fan between joists. Make sure the fan body is level and
perpendicular with the joist. (Fig. H)
7. Replacement installation: After making electrical and
ductwork connections (see steps 2~5), nail housing in
place. Drive nails through the housing where
indicated by arrows. (Fig. I)
8. New installation in an existing ceiling : Bend tabs
outward 90°(Use a screw driver if desired) and position
housing so that tabs rest against bottom edge of joists
(or front of stud). Nail housing to joist or stud using
four nails to ensure a solid, quiet installation. Ceiling
installations: Tabs on opposite side of housing can be
bent outward to rest on top of 1/2" ceiling material
and provide extra stability. (Fig. J)
9. Plug in the motor and locking the fan body back by
using three screws. (Fig. C)
10. Squeeze grille springs together and insert springs into
slots in motor plate. Push grille up against ceiling.
When the power on, check for abnormal vibration or
sound. Insert the mounting springs into the slots and
mount the grille to the body. (Fig. K)
WARRANTY
Page 2.
Proper insulation around the fan to minimize building heat
loss and gain. 4” circular duct is recommended for installation.
The ducting from this fan to the outside of building has a
strong eect on the air ow, noise and energy use of the
fan. Use the shortest, straightest duct routing possible for
best performance, and avoid installing the fan with smaller
ducts than recommended. Insulation around the ducts can
reduce energy loss and inhibit mold growth. Fans installed
with existing ducts may not achieve their rated air ow.
INSTALLATIONS
Install with wood frame
Model No. ITG80
Install Dim.
(Inch) 7.5X7.25
Fig. C
Fig. C
Fig. D
Fig. E
Fig. F
Fig. G
Fig. H
Fig. H
Fig. H
Fig. I
Fig. J
Fig. K
MODEL: ITG80
DELTA ELECTRONICS THREE YEARS
LIMITTED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the
original consumer purchaser in the USA and Canada that
the Breez ventilation fan products will be free from defects
in material or workmanship. This warranty is limited to
three (3) years from the original date of purchase.
Limitations and Exclusions
During the warranty period, a replacement for any
defective product will be supplied free of charge for
installation by the consumer. The warranty provided
herein does not cover charges for labor or other costs
incurred in the troubleshooting, repair, removal, and
installation service.
All returns of defective parts or products must include
the product model number, and must be made through
an authorized Delta Electronics distributor. Authorized
returns must be shipped prepaid. Repaired or
replacement products will be shipped by Delta
Electronics F.O.B. shipping point.
Delta Electronics shall not be liable for any indirect,
incidental, consequential, punitive, or special damages
arising out of or in connection with products use or
performance, regardless of the form of action whether in
contract, tort (including negligence), strict product
liability or otherwise.
This warranty does not extend to uorescent lamp
starters and tubes.
The warranty does not cover if user does not comply with
manufacture’s installation manual.
To qualify for warranty service, you must notify Delta
Electronics at the address or telephone number below.
Delta Electronics shall have no liability to the original
owner-user with respect to any defect caused by abuse,
misuse, neglect, improper transportation or storage,
improper testing, improper installation, improper
operation, improper use, improper maintenance,
improper repair, improper alteration, improper
modication, tampering or accident of products or parts
thereof, or unusual deterioration or degradation of
products or parts thereof due to a physical environment
beyond the requirements of products’ specications.
Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889

Other Delta Fan manuals

Delta KHB1248GHS User manual

Delta

Delta KHB1248GHS User manual

Delta KHB1748HHT User manual

Delta

Delta KHB1748HHT User manual

Delta BreezSlim SLM70-LVDC User manual

Delta

Delta BreezSlim SLM70-LVDC User manual

Delta Breez GreenBuilder GBR50 User manual

Delta

Delta Breez GreenBuilder GBR50 User manual

Delta VFB080D4LED1 User manual

Delta

Delta VFB080D4LED1 User manual

Delta breez 110LED-ADJ User manual

Delta

Delta breez 110LED-ADJ User manual

Delta VFB080D4H1 User manual

Delta

Delta VFB080D4H1 User manual

Delta VFB32AGTH User manual

Delta

Delta VFB32AGTH User manual

Delta BFB0305HA Manual

Delta

Delta BFB0305HA Manual

Delta NFB1212H User manual

Delta

Delta NFB1212H User manual

Delta breez GreenBuilder GBR80LED User manual

Delta

Delta breez GreenBuilder GBR80LED User manual

Delta breez integrity ITG80RLED-ADJ User manual

Delta

Delta breez integrity ITG80RLED-ADJ User manual

Delta VFB24ACTH User manual

Delta

Delta VFB24ACTH User manual

Delta breez VFB25ACH User manual

Delta

Delta breez VFB25ACH User manual

Delta FT-740 User manual

Delta

Delta FT-740 User manual

Delta breez SMT150LED User manual

Delta

Delta breez SMT150LED User manual

Delta Breez GreenBuilder GBR50 User manual

Delta

Delta Breez GreenBuilder GBR50 User manual

Delta RAD80L User manual

Delta

Delta RAD80L User manual

Delta Breez 50F-LED User manual

Delta

Delta Breez 50F-LED User manual

Delta SFB0212H User manual

Delta

Delta SFB0212H User manual

Delta GBR100 User manual

Delta

Delta GBR100 User manual

Delta Breez GreenBuilder GBR80 User manual

Delta

Delta Breez GreenBuilder GBR80 User manual

Delta VFB080C4A1 User manual

Delta

Delta VFB080C4A1 User manual

Delta breez RAD80-DGL User manual

Delta

Delta breez RAD80-DGL User manual

Popular Fan manuals by other brands

Eurolux F17 quick start guide

Eurolux

Eurolux F17 quick start guide

SMAY iSWAY Operation and maintenance manual

SMAY

SMAY iSWAY Operation and maintenance manual

Insignia NS-F4T6-WH Quick setup guide

Insignia

Insignia NS-F4T6-WH Quick setup guide

Natural Light Gable Solar Fan installation instructions

Natural Light

Natural Light Gable Solar Fan installation instructions

Hunter 20345 Owner's guide and installation manual

Hunter

Hunter 20345 Owner's guide and installation manual

Envirovent SILENT 100 Instruction leaflet

Envirovent

Envirovent SILENT 100 Instruction leaflet

Lakeland 24771 quick start guide

Lakeland

Lakeland 24771 quick start guide

Heylo PowerVent 4000-e user manual

Heylo

Heylo PowerVent 4000-e user manual

Helios KWL-Center 1200 Operation and installation instructions

Helios

Helios KWL-Center 1200 Operation and installation instructions

Siegenia AEROMAT VT RS1 Original operating instructions

Siegenia

Siegenia AEROMAT VT RS1 Original operating instructions

Harbor Breeze CLASSIC STYLE 00819 installation guide

Harbor Breeze

Harbor Breeze CLASSIC STYLE 00819 installation guide

Vivax TF-62 instruction manual

Vivax

Vivax TF-62 instruction manual

Awenta SILENCE Series operating manual

Awenta

Awenta SILENCE Series operating manual

Kendal Lighting AC-19752 installation instructions

Kendal Lighting

Kendal Lighting AC-19752 installation instructions

Hunter Anisten installation manual

Hunter

Hunter Anisten installation manual

Qazqa Kolm 102718 instruction manual

Qazqa

Qazqa Kolm 102718 instruction manual

Bionaire BAFE1407 instruction manual

Bionaire

Bionaire BAFE1407 instruction manual

Livington Smart Air Instructions for use

Livington

Livington Smart Air Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.