MODEL
:
ITG100
INSTALLATION AND OPERATING INSTRUCTIONS
CEILING / WALL VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
General Safety Information
1. Make sure that the electric service supply
voltage is AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as
well as the National Electrical Code (NEC) and
the Occupational Safety and Healthy Act
(OSHAct).
3. Always disconnect the power source before
working on or near the ventilating fan, motor or
junction box.
4. Protect the power cord from sharp edges, oil,
grease, hot surfaces, chemicals or other
objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are
configured as shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or
shower when installed in a GFCI protected
branch circuit.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have any questions,
contact the manufacturer.
2. Before servicing or cleaning the unit, switch
power off at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.
4. Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the
American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the
local code authorities.
5. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the
outdoors.
7. If this unit is to be installed over a tub or shower,
it must be marked as appropriate for the
application and be connected to a GFCI
(Ground Fault Circuit Interrupter) – protected
branch circuit.
8. Do not use this unit with any other solid-state
control device. Solid-state controls devices may
cause harmonic distortion, which can cause a
motor humming noise.
9. NEVER place a switch where it can be reached
from a tub or shower.
10. Not to be installed in a ceiling thermally
insulated to a value greater than R50. (This is
required for installation in Canada only).
Turning angle too large Duct shrink
Too many elbows Elbow near the body
Body
Minimum 18 in.
CAUTION
1. For General Ventilating Use Only. Do Not Use
To Exhaust Hazardous Or Explosive Materials
And Vapors.
2. Not for use in cooking area. (Fig. B)
3. This product must properly connect to the
grounding conductor of the supply circuit.
4. To reduce the risk of injury to persons, install
the fan at least 8.2 feet (2.5m) above the floor.
Cooking area
SUPPLIED ACCESSORIES
Part name
Appearance Quantity
Grille
1
Fan &
Housing
1
4” Duct
1
Screw
(M4x12)
3
INSTALLATIONS
Proper insulation around the fan to minimize building
heat loss and gain. 4” circular duct is recommended
for installation. The ducting from this fan to the
outside of building has a strong effect on the air flow,
noise and energy use of the fan. Use the shortest,
straightest duct routing possible for best performance,
and avoid installing the fan with smaller ducts than
recommended. Insulation around the ducts can
reduce energy loss and inhibit mold growth. Fans
installed with existing ducts may not achieve their
rated air flow.
Install with wood frame
Model No. ITG100
Install Dim.
(Inch) 7-1/2 x 7-1/4
1. Remove motor plate from housing by
removing three screws. (Fig. C)
2. Remove wiring cover from housing by pulling
straight out. Choose a hole and use a slotted
screwdriver to remove it. (Fig. D)
3. Follow all local electrical and safety codes.
NEVER place a switch where it can be
reached from a tub or shower. Connect wires
as shown in wiring diagrams. (Fig. E)
4. Using wire nuts(not provided), connect house
power cable to ventilating fan wires. 14 AWG
(2.1 mm2) is the smallest conductor that shall
be used for branch-circuit wiring. (Fig. F)
5. Insert the duct into the duct connector and
tape all ductworks connection to make them
secure and airtight. Install the duct with a
gradient 1°~2°to the outside. (Fig. G)
6. New installation prior to finishing the
ceiling or wall: Insert the fan between joists.
Make sure the fan body is level and
perpendicular with the joist. (Fig. H)
7. Replacement installation: After making
electrical and ductwork connections (see steps
2~5), nail housing in place. Drive nails through
the housing where indicated by arrows. (Fig. I)
8. New installation in an existing ceiling or
wall:
Bend tabs outward 90°(Use a screw
driver if desired) and position housing so that
tabs rest against bottom edge of joists (or front
of stud). Nail housing to joist or stud using four
nails to ensure a solid, quiet installation.
Ceiling installations: Tabs on opposite side of
housing can be bent outward to rest on top of
1/2" ceiling material and provide extra stability.
(Fig. J)
9. Plug in the motor and locking the fan body
back by using three screws. (Fig. C)
10. Squeeze grille springs together and insert
springs into slots in motor plate. Push grille up
against ceiling or wall. When the power on,
Fig. A
Fig. B
MODEL
:
ITG100
check for abnormal vibration or sound. Insert
the mounting springs into the slots and mount
the grille to the body. (Fig. K)
Fig. C
Fig. C
Fig. D
Fig. E
Fig. F
Fig. G
Fig. H
Fig. H
Fig. H
Fig. I
OPERATION
Single speed control mode: Turn the power switch
to operate ON/OFF.
MAINTENANCE:
Disconnect the power source before working on the
unit. Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any
other such chemicals for cleaning the
ventilating fan.
2. Do not allow water to enter the motor.
3. Do not soak resin parts in water over 140oF
(60°C).
CLEANING:
1. Pull down the spring to remove the grille.
2. Wash and clean the grille. (Use non-abrasive
kitchen detergent and wipe dry with a new
cloth.)
3. Remove dust and dirt from the ventilating fan
using a vacuum cleaner.
4. Using a cloth dampened with kitchen detergent,
remove any dirt from the ventilating fan. Wipe
dry with a new cloth.
5. Replace the grille.
SPECIFICATIONS
Note: Design and specifications are subject to change without
notice.
DIMENSIONS
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED
WARRANTY
Delta Electronics Inc.(“Delta Electronics”)
warrants to the original consumer purchaser in the
USA that the Breez ventilation fan products will be
free from defects in material or workmanship. This
war
ranty is limited to three (3) years from the original
date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for
any defective product will be supplied free of
charge for installation by the consumer. The
warranty provided herein does not cover charges
for labor or other costs incurred in the
troubleshooting, repair, removal, and installation
service.
2. All returns of defective parts or products must
include the product model number, and must be
made through an authorized Delta Electronics
distributor. Authorized returns must be shipped
prepaid. Repaired or replacement products will
be shipped by Delta Electronics F.O.B. shipping
point.
3. Delta Electronics shall not be liable for any
indirect, incidental, consequential, punitive, or
special damages arising out of or in connection
with products use or performance, regardless of
the form of action whether in contract, tort
(including negligence), strict product liability or
otherwise.
4. This warranty does not extend to fluorescent
lamp starters and tubes.
5. The warranty does not cover if user does not
comply with manufacture’s installation manual.
6. To qualify for warranty service, you must notify
Delta Electronics at the address or telephone
number below.
7. Delta Electronics shall have no liability to the
original owner-user with respect to any defect
caused by abuse, misuse, neglect, improper
transportation or storage, improper testing,
improper installation, improper operation,
improper use, improper maintenance, improper
repair, improper alteration, improper modification,
tampering or accident of products or parts
thereof, or unusual deterioration or degradation of
products or parts thereof due to a physical
environment beyond the requirements of
products’ specifications.
Address: 46101 Fremont Boulevard, Fremont,
CA 94538
US Toll Free Number: 1-888-979-9889
Model No.
Voltage
(V)
Frequency
(Hz)
Air Flow
@ 0.1”SP
(CFM)
Power
@0.1”SP
(W)
Max
Current
(Amps)
Weight
(lb.) Note
ITG100
120 60 100 17.0 0.33 6.61

Other Delta Fan manuals

Delta AirEye Ion User manual

Delta

Delta AirEye Ion User manual

Delta breez GreenBuilder GBR80LED User manual

Delta

Delta breez GreenBuilder GBR80LED User manual

Delta BreezGreenBuilder GBR80LED User manual

Delta

Delta BreezGreenBuilder GBR80LED User manual

Delta Breez GreenBuilder GBR50 User manual

Delta

Delta Breez GreenBuilder GBR50 User manual

Delta 110HLEDNL User manual

Delta

Delta 110HLEDNL User manual

Delta SIG80L User manual

Delta

Delta SIG80L User manual

Delta VFB080C4L1 User manual

Delta

Delta VFB080C4L1 User manual

Delta breez VFB160D6A3-DGL User manual

Delta

Delta breez VFB160D6A3-DGL User manual

Delta Breez 150F User manual

Delta

Delta Breez 150F User manual

Delta breez VFB25ADH User manual

Delta

Delta breez VFB25ADH User manual

Delta breez VFB25ACH User manual

Delta

Delta breez VFB25ACH User manual

Delta Breez 50F-LED User manual

Delta

Delta Breez 50F-LED User manual

Delta BreezIntegrity ITG80 User manual

Delta

Delta BreezIntegrity ITG80 User manual

Delta VFB080D4H1 User manual

Delta

Delta VFB080D4H1 User manual

Delta FRS200/VDB200F6D1 User manual

Delta

Delta FRS200/VDB200F6D1 User manual

Delta EFB0405HA Manual

Delta

Delta EFB0405HA Manual

Delta Breez Integrity ITG50LED User manual

Delta

Delta Breez Integrity ITG50LED User manual

Delta BFB0305HA Manual

Delta

Delta BFB0305HA Manual

Delta FT-740 User manual

Delta

Delta FT-740 User manual

Delta AirEye 007180 User manual

Delta

Delta AirEye 007180 User manual

Delta VFB080D4LED1 User manual

Delta

Delta VFB080D4LED1 User manual

Delta breez integrity ITG80RLED-ADJ User manual

Delta

Delta breez integrity ITG80RLED-ADJ User manual

Delta Powerfoil D User manual

Delta

Delta Powerfoil D User manual

Delta GBR100L User manual

Delta

Delta GBR100L User manual

Popular Fan manuals by other brands

Vent-Axia HR100R Installation and servicing instructions

Vent-Axia

Vent-Axia HR100R Installation and servicing instructions

Dietz DN Operating and assembly instructions

Dietz

Dietz DN Operating and assembly instructions

BorMann Elite BFN9015 manual

BorMann

BorMann Elite BFN9015 manual

Hinkley FINNIGAN instruction manual

Hinkley

Hinkley FINNIGAN instruction manual

Canarm Tri-Lite HVLS SERIES Design & engineering guide

Canarm

Canarm Tri-Lite HVLS SERIES Design & engineering guide

Trane VUV 1500 CFM Installation and owner's guide

Trane

Trane VUV 1500 CFM Installation and owner's guide

NuTone Heat-A-Vent 605RP installation instructions

NuTone

NuTone Heat-A-Vent 605RP installation instructions

CFM SEF Installation & maintenance instructions

CFM

CFM SEF Installation & maintenance instructions

Arbonia Sabiana Carisma CRSL Instructions for installation, use and maintenance manual

Arbonia

Arbonia Sabiana Carisma CRSL Instructions for installation, use and maintenance manual

Craftmade Log Cabin LC52 Specifications

Craftmade

Craftmade Log Cabin LC52 Specifications

NuTone inVent AE80SL Installation and Use & Care Instructions

NuTone

NuTone inVent AE80SL Installation and Use & Care Instructions

Bayside LAGOON CTC Installation, operation, maintenance & warranty information

Bayside

Bayside LAGOON CTC Installation, operation, maintenance & warranty information

Nederman SYSTEM 920 user manual

Nederman

Nederman SYSTEM 920 user manual

Monte Carlo Fan Company 3TTHR44 D Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3TTHR44 D Series Owner's guide and installation manual

Regency Cabana owner's manual

Regency

Regency Cabana owner's manual

Hunter 21705 Manual de Installatión y Operatión

Hunter

Hunter 21705 Manual de Installatión y Operatión

Monte Carlo Fan Company 3MNLR56 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3MNLR56 Owner's guide and installation manual

Marley CLASSIC C11 Operating & assembly instructions

Marley

Marley CLASSIC C11 Operating & assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.