Detex EAX-500 User manual

9V Battery
P/N: PP-5567 (or equivalent)
Battery retainer
P/N: 102606
Circuit board kit
P/N: 102656-1 (Standard)
Cam assembly kit
P/N: 102655
Magnet locator
P/N: 102607
Switch guard
P/N: 102613
03 Rim cylinder plate
P/N: 102638
#8-32 Truss HD screw
P/N: 102627-15
Cover lock,
nut, and 2 keys
P/N: PP-5572
Cylinder nut
P/N: 100783
Parts breakdown depiction
(Mortise cylinder required)
Locate this component for Step 6
DETEX 101321
INSTALLATION INSTRUCTIONS FOR THE EAX-500 EXIT ALARM
Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045
(830)629-2900 / 1-800-729-3839 / Fax (830)620-6711
E-MAIL: [email protected] INTERNET: www.detex.com
101321 September 15, 2008
U.S. PATENT NUMBERS:
20050257389
20050231363
20050223764
Magnet Kit
P/N: 102665
Hardware Kit
P/N: 102633
Backplate
P/N: 102603
Mortise cylinder required (standard yale cam)
Detex P/N: 102281-X
CORRECT
"ON" position
(Key can be removed)
position
shown in "OFF"
Key and cams
"OFF" position
(Key cannot be removed)
.050" Hex Wrench
(NOT PROVIDED)
position
stop "ON"
shown in 90°
Key and cams
"ON"
position
(If Key
Stop
installed)
EAX-500 Operations
Key orientation
Figure 1
"OFF"
position
"ON"
position
NOTE: Key Stop will prevent key
removal in "OFF" position
(Key stop included in hardware kit)
Rotate key to this
position before reinstalling
cam assembly
Mortise cam orientation
as shown
Key stop
installed
Ins No: 101321
NOTE: Depending on models ordered, delay times may vary
WRONG
Back View
Front View
Cam orientation
for Key Stop option
KEY STOP POSITIONS
Figure 2: KEY STOP INSTALLATION
Top surface of Key Stop should
NOT protrude beyond highest
point on plastic cam
Install key stop
P/N: 102688
SPECIAL NOTES and DEFINITIONS:
1. The door needs to be closed to test the unit.
2. When operating the ON/OFF switch, there is a slight delay.
3. The key is inserted and removed only in the vertical position (home position).
4. Key function: counter clockwise (CCW) = Armed; clockwise (CW) = Disarmed
5. The battery needs to be disconnected to register changes in the slide switches.
a. Status Indicator (This will affect battery life)
b. Disable Auto Rearm
6. The bottom left switch is only used when the outside key control function is used.
7. If re-handing is necessary remove battery and place magnet on left or right side and reconnect the battery.
OPERATIONS:
To arm the system, close the door and turn the key counter clockwise (CCW) to the 8 o'clock position or until you
feel and/or hear a click. The switch on the bottom right side of the board should be engaged by the plastic
actuator and maintained. This is the 'ON' position. The red light should blink twice and the green light will come
on solid for the arming time sequence (default 15 seconds). After the arming time, the green light will turn off and
the unit will beep three times. At this time, the alarm is armed and if the door is opened the alarm will sound and
the red light will turn on.
DISARMING:
To turn off the alarm or disarm the system, turn the key clockwise (CW) to the 2 o'clock position.
The bottom right switch should be released.
TROUBLESHOOTING:
If the unit does not arm, the magnet may need to be re-aligned or shimmed closer to the EAX-500. If the unit fails
to operate, confirm the slide switches are in the default condition (see step 4) and disconnect and reconnect the
battery. If re-handing is necessary remove battery and place magnet on left or right side and reconnect the battery.
LOW BATTERY ALERT:
1. Siren will beep and red LED will blink at approximately 45 second intervals when battery is low
STATUS INDICATOR:
1. Slide the switch to ON and then, install battery.
2. If the unit is armed, the red LED will blink every 3 seconds.
3. If the unit is disarmed, the green LED will blink every 3 seconds.
Disable AUTO REARM:
1. Slide switch to OFF and then, install battery.
2. Unit arms as described above.
3. Once the unit is in full alarm and the door closes, the alarm will shut off after 2 minutes.
Table A: Selector Switch Functions
STATUS
INDICATOR
STATUS DESCRIPTION
OFF* No indication that device is armed or disarmed.
ON
DISABLE AUTO
REARM STATUS DESCRIPTION
OFF
DEFAULT: Alarm will automatically rearm 2 minutes after alarm
has been activated and door closed.
Custom settings can be programmed by DETEX.
ON* Alarm will not automatically rearm after alarm has been
activated.
STEP 6: PREP DOOR STEP 7: INSTALL DEVICE
STEPS 1-5: PREP DEVICE
Mark/drill backplate and magnet holes on door
and frame/mullion
*Default settings; **Will shorten battery life
DOOR
ASSEMBLE
6
Install magnet, backplate and cover
Install magnet with (2)
#4-40 or #4 screws
Install backplate with (2)
#1/4-20 or #14 screws
7
FRAME/MULLION
LHR installation shown
for reference only
DOOR
NOTE: Remove locator and backplate prior to drilling mounting holes
Set cam position
as shown
Re-install cam assembly
3
CORRECT WRONG
Connect 9-volt battery and
install as shown
5
Remove cam assembly from
cover
Unfasten (2) screws
1
Install mortise cylinder with cylinder nut provided
Cam orientation
as shown
2 4
DISABLE AUTO
REARM
STATUS
Turn key CW
to lock cover
OKC
ARMED - red LED blinks approximately every 3 seconds.**
DISARMED - green LED blinks approximately every 3 seconds.**
Hook at bottom, then tilt
cover over backplate
Mortise cylinder
NOT provided
Backplate
Drill #7 for #1/4-20
machine screws
Drill 7/32" or 3/16" for
#14 sheetmetal screws
Magnet
Drill #43 for #4-40
machine screws
Drill #44 for
#4 sheetmetal
screws
Backplate
Drill #7 for #1/4-20
machine screws
Drill 7/32" or 3/16" for #14 sheetmetal screws
INDICATOR
1-1/2
Fitting or nut NOT included
Cut (JP1) jumper
Flex walls outward to remove guard & board
1"
Drill 7/8 dia
(1) place
Screw wires to (P1) terminal block
MULTI-DOOR FUNCTION
Recommended hole size
(Recommended installation)
White
Black
Terminal
P/N: PP-5107
White
Black
Mag
Switch 1
Switch 2
Mag
(18ga Max wire dia)
3/4"
1-3/8"
Dia
DOOR
TAILPIECE PROVIDED
NOTE: For "Key Stop", See Figure 2
Where applicable,
mark TOP hole center & drill
1/4" dia. pilot hole through door
See OKC INSTALLATION
Drill 1-1/4" hole
through outside
door face
Drill 1-3/8" hole
through inside
door face
Cylinder Side:
Device Side:
1-1/4"
Dia
IMPORTANT!
Ins No: 101321
Collar required if distance
is greater than 5/16".
7-pin cylinders ONLY
Install mortise cylinder with cylinder nut provided
Optional collar can be ordered
from Detex (p/n: ECL-1595)
Diagram shown typical for two door magnetic
switches:
MS-1039S & MS-1059S wire in series.
MS-2049 SHOWN (Red wire not used)
Outside Key Control Installation
Rim cylinder - Detex P/N: ECL-445K-X
Set selector switch functions (See Table A)
Default settings
Closed contact when door is closed
NOTES:
1. If wire runs longer than 10 feet,
must use twisted pair
2. 1/16" slotted jeweler screw driver required.
3. If internal contact is used DO NOT
cut jumper (JP1)

Other Detex Door Lock manuals

Detex ADVANTEX 87 Series User manual

Detex

Detex ADVANTEX 87 Series User manual

Detex ADVANTEX 62 Series User manual

Detex

Detex ADVANTEX 62 Series User manual

Detex ADVANTEX 82 Series User manual

Detex

Detex ADVANTEX 82 Series User manual

Detex ADVANTEX 80 Series User manual

Detex

Detex ADVANTEX 80 Series User manual

Detex ADVANTEX 70 Series User manual

Detex

Detex ADVANTEX 70 Series User manual

Detex ADVANTEX 30 Series User manual

Detex

Detex ADVANTEX 30 Series User manual

Detex ECL-620 User manual

Detex

Detex ECL-620 User manual

Detex Advantex 10 Series Instruction Manual

Detex

Detex Advantex 10 Series Instruction Manual

Detex ADVANTEX 60 Series User manual

Detex

Detex ADVANTEX 60 Series User manual

Popular Door Lock manuals by other brands

Schlage BE468 series manual

Schlage

Schlage BE468 series manual

clare Kwikset 916 Z-Wave Integration Release Notes

clare

clare Kwikset 916 Z-Wave Integration Release Notes

Signature Hardware Traeger 946282-DU manual

Signature Hardware

Signature Hardware Traeger 946282-DU manual

Yale 5400 Series installation instructions

Yale

Yale 5400 Series installation instructions

Weiser 26924 instructions

Weiser

Weiser 26924 instructions

PS ONE quick start guide

PS

PS ONE quick start guide

Spectrum Brands SD004: SD005 Assembly instructions

Spectrum Brands

Spectrum Brands SD004: SD005 Assembly instructions

Supra TRAC-Lock BT installation instructions

Supra

Supra TRAC-Lock BT installation instructions

SMART H2-TBW user manual

SMART

SMART H2-TBW user manual

Hyundai Telecom HDL-5290SK user manual

Hyundai Telecom

Hyundai Telecom HDL-5290SK user manual

Water Street Mortise Passage Set installation instructions

Water Street

Water Street Mortise Passage Set installation instructions

Dr. Hahn VL-Band installation instructions

Dr. Hahn

Dr. Hahn VL-Band installation instructions

Kaba Solitaire 710-II Series installation guide

Kaba

Kaba Solitaire 710-II Series installation guide

JNF Q System IN.81.121 quick start guide

JNF

JNF Q System IN.81.121 quick start guide

Anker eufy Security T8510 user manual

Anker

Anker eufy Security T8510 user manual

Nice LN-5000 UL3 BT Instructions and warnings for installation and use

Nice

Nice LN-5000 UL3 BT Instructions and warnings for installation and use

NORMBAU EST 40 PZ Fixing instructions

NORMBAU

NORMBAU EST 40 PZ Fixing instructions

Water Street Brass 41015 manual

Water Street Brass

Water Street Brass 41015 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.