BD4
Occ pancy Detector
For 4 Detection Sections
For se with DS64 or SE8
Series Stationary Decoders
Features
nOccupancy Detection or 4 detection sections lets you know when rolling
stock is in a detection section on your layout
nOutputs fo LEDs to indicate local detection section occupancy and zone
power status on a panel mounted display
n3 Amp capacity per detection section
nConnect to LocoNet via your DS64 or SE8 series decoder to transmit occu-
pancy in ormation to your LocoNet system (works with the older DS54 too)
nDetects any powe ed locomotive
nDetects un-powe ed olling stock equipped with esisto wheel sets
nAnti-Chatte Filte For Reliable Occupancy Detection
Parts List
1 BD4 1 Instruction Manual
1 Block Monitor
The BD4 requires a DS64 or SE8 Series Stationary Decoder (sold separately) or
LocoNet reporting.
NOTE: The BD4 operates up to a maximum resistance across the tracks o
10Kohms or positive occupancy detection. Do not connect any other devices or
loads across the detection section track or proper operation.
Digit ax Manuals and Inst uctions a e updated pe iodically.
Please visit www.digit ax.com fo the latest ve sion of all manuals.
Digitrax, LocoNet, Super Empire Builder, Super Chief, Zephyr and others included in this man-
ual are trademarks of various manufacturers including Digitrax. Digitrax products are covered
y multiple U.S. & International Patents and Patent applications.
Digitrax, Inc. is not responsi le for unintentional errors or omissions in this document.
©2010 Digitrax, Inc. www.digitrax.com 1
Com lete Train Control
Run Your Trains, Not Your Track!
All Scales
Occ pancy Detection
5 Amps Peak, 3 Amps Contin o s
Made in U.S.A.
307-7007-0000
2443 Transmitter Road
Panama City, FL 32404
www.digitrax.com
T850-872-9890
F850-872-9557
BD4
Occ pancy Detector for 4 Detection Sections
1
2
3
4
Detection Section 1
Detection Section 2
Detection Section 3
Detection Section 4
To Booster Rail A Connection
To Booster Rail B Connection
Rail A
Rail B (Detection Common)
*10 Pin Ribbon Cable
Connector From LED 1 Header
To Panel Mounted LEDs for
Occupancy Indication
Pin 1
Pin To LEDs
1 DS 1 Indicator LED+
2 Ground on LED
3 DS 2 Indicator LED+
4 Ground on LED
5 DS 3 Indicator LED+
6 Ground on LED
7 DS 4 Indicator LED+
8 Ground on LED
9 Track Status LED+
10 Ground for Track Status LED
DS1 Plug
Use 10 pin ribbon
cable to DS54
or SE8C
DS1
Pin 1
LED1
Pin 1
LED1 Plug with
Block Monitor plugged in
remove Block Monitor
& plug in 10 pin ribbon
cable to wire remote
occupancy indication LEDs.
Note: Block Monitor should
be plugged in with LEDs
facing away from screw
terminal connector
* A 10 Pin Ribbon Cable is the most
convenient way to wire the BD4. You
can build your own ribbon cables or you
can use the Digitrax Signal Driver Cable
Kit (Part # SDCK). Alternately, you can
wire directly to the pins on either or both
of the headers. The header pin arrangement is:
Pin 1
Pin 3
Pin 5
Pin 7
Pin 9
Pin 2
Pin 4
Pin 6
Pin 8
Pin 10
Pin Out for LED1
*10 Pin Ribbon Cable
Connector From DS1 Header
To DS54 Input Plug or SE8
Card Edge Connector
Pin 1
Pin To DS54 or SE8
1 DS 1 on DS54 or SE8
2 Ground on DS54 or SE8
3 DS 2 on DS54 or SE8
4 Ground on DS54 or SE8
5 DS 3 on DS54 or SE8
6 Ground on DS54 or SE8
7 DS 4 on DS54 or SE8
8 Ground on DS54 or SE8
9 Not Used
10 Not Used
Pin Out for DS1
Note: All detection sections from each
BD4 must be powered by the same
booster. (They must all be in the same
power district.)
Pin 10 must bemust be connected to system
ground such as the AX1 terminal of
the DS64, Ground on the
booster terminal, etc.
Pin 10
BD4 Wiring Diagram
See www.digitrax.com for additional information a out BD4, DS64 and SE8 series decoders.
The BD4’s sensitivity can e decreased y connecting a 1/4 watt resistor in the range of
47ohms to1 Kohm from the DS (detection section) screw terminal to the Rail A screw terminal
on the screw connector on the BD4. Each DS 1-4 can e adjusted separately.