manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Dimplex
  6. •
  7. Timer
  8. •
  9. Dimplex PX01001 User manual

Dimplex PX01001 User manual

Other Dimplex Timer manuals

Dimplex DCU-2T User manual

Dimplex

Dimplex DCU-2T User manual

Dimplex RXPW1 User manual

Dimplex

Dimplex RXPW1 User manual

Popular Timer manuals by other brands

SATO TM-29 instruction manual

SATO

SATO TM-29 instruction manual

Full Gauge Controls ICEMATIC quick start guide

Full Gauge Controls

Full Gauge Controls ICEMATIC quick start guide

CEI Ultrak T-3 instructions

CEI

CEI Ultrak T-3 instructions

Raindrip R675CT Installation & programming

Raindrip

Raindrip R675CT Installation & programming

Intermatic P1131 owner's manual

Intermatic

Intermatic P1131 owner's manual

Profile 010200280 instruction manual

Profile

Profile 010200280 instruction manual

Gizmo T4 instructions

Gizmo

Gizmo T4 instructions

Tekmar Timer 031 Data brochure

Tekmar

Tekmar Timer 031 Data brochure

Daikin DST301B61 Operation manual

Daikin

Daikin DST301B61 Operation manual

sisel ENDA ETM2432 manual

sisel

sisel ENDA ETM2432 manual

B&Q TE103 Installation and use instructions

B&Q

B&Q TE103 Installation and use instructions

Hozelock AC Plus 2700 instructions

Hozelock

Hozelock AC Plus 2700 instructions

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

GIC

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

Emos EMT400F quick start guide

Emos

Emos EMT400F quick start guide

FarmTek Polaris operating instructions

FarmTek

FarmTek Polaris operating instructions

Citizen ME2 series instruction manual

Citizen

Citizen ME2 series instruction manual

Primex OneVue Sync B100 install guide

Primex

Primex OneVue Sync B100 install guide

Rain Bird Optima PRT-4 owner's manual

Rain Bird

Rain Bird Optima PRT-4 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

2. The location of the control is important, it will not function
correctly if above or within 500mm of a heat source or
draught. Care must also be taken not to obscure the slots at
the top or bottom of the control and that it is not exposed to
direct bright sunlight or close to a lamp fitting. Best
temperature accuracy will be achieved by mounting on an
internal wall or partition.
3. The pattress boxes (not provided) should have a depth of at
least 25mm. Plastic pattress boxes with vertical pillars are not
suitable.
Vertical tabs in metal pattress boxes should be removed.
Ensure all entries into the pattress boxes are sealed to
prevent draughts.
4. Before fitting to the mounting box setback temperature,
comfort temperature and comfort period must be selected. To
do this, adjust the appropriate dial on the reverse of the PCB.
5. The supply cable is not provided and should therefore be
selected to suit the appliance.
Warning: Although the control does not need an earth, the
appliance probably does. Ensure that the mounting box is
fitted with an earth terminal for earth continuity to the
appliance.
6. To connect the control in circuit wire in to the clearly marked
terminal block on the rear of the controller. The control must
only be connected via fixed wiring.
7. Secure the control to the pattress box such that there are no
gaps between the controller and wall or pattress box.
Note: If tamperproof screws are required they should be M3 x 40mm
long, counter sunk with a head diameter of no more than 6.5mm.
Installation and
Operating Instructions
Press Button Delay Timer - Model No. PX01001
Safety Warnings
1. WARNING: DO NOT USE THIS APPLIANCE IN THE
IMMEDIATE SURROUNDINGS OF A BATH, A SHOWER
OR SWIMMING POOL
2. WARNING: DO NOT USE WHERE EXCESSIVE DUST OR
MOISTURE IS PRESENT
3. WARNING: FOR USE IN NORMAL POLLUTION
SITUATIONS ONLY
General Description
The PX01001 timer/thermostat can be used in conjunction with
heating appliances. They may be flush or surface mounted using a
standard 25mm box. The control is rated at 16A (250VAC) and can
be used in conjunction with heating appliances with a maximum total
input of 13 A resistive L.C. 230V - 50Hz. The controller cannot be
used with a Quartz heater without a suitable in-line contactor.
Control action: Type 1B
Operating Instructions
The PX01001 controls the room temperature by interrupting the
power supply to the appliance, therefore the appliance should
always be switched on and its thermostat set to maximum
temperature. Note this will not be reached if the pre-determined
maximum level is below that of the appliance thermostat setting.
When the comfort mode is activated by pressing the
centre of the control face, the green light illuminates.
The comfort mode allows the room to be heated to a pre-
determined temperature for a pre-determined time
period.
The red light indicates that the heater is operating.
Note that the heater will remain on for a minimum of 1
minute.
The red light may also be illuminated in the set back
mode when the PX01001 switches the heater on to
maintain the predetermined background temperature.
Installation
Before undertaking installation work, ensure the electricity supply is
disconnected from any relevant fixed wiring.
1. The control and heater should be installed in compliance with
the IEE Wiring Regulations
comfort
control
Dimplex
TOUCH
85mm
85mm
25mm
boost
Main Dimensions
boost
Ensure 500mm clearance from any heat source or draught.
T0105/004/A
General Cleaning
WARNING
BEFORE UNDERTAKING CLEANING WORK ON THE
CONTROLLER OR APPLIANCE IMMEDIATELY DISCONNECT
THE ELECTRICITY SUPPLY BY SWITCHING OFF AT THE
ADJACENT DOUBLE POLE SWITCH.
The outside of the appliance should be wiped over with a soft damp
cloth and then dried. Do not use detergents or abrasives.
After Sales Service
Your Dimplex Comfort Control is guaranteed for one year from date
of purchase. We undertaketo exchange or repair free of charge
within this period, any part found to be defective.
Should you require after sales service, please get in touch with the
supplier through whom you purchased the appliance, or your
nearest Service Agent.
Please do not initially return a faulty appliance or part of an appliance
to us as this may result in transit damage and/or delay in providing
service. Let us know your difficulty quoting the model number and
series of the appliance. We will then take the appropriate action.
L
Live
Output
Live
Neu- N
Setback
temp.
Comfort
temp. Timing
16ºC 25ºC 5ºC 19ºC
Comfort Temperature Setback Temperature
Glen Dimplex UK Ltd
MillbrookHouse
Grange Drive
Hedge End
Southampton
Hampshire SO30 2DF
Customer Services: Tel. 0870 7270101
Fax. 0870 7270102
email customer.services@glendimplex
Republic of Ireland Tel. 01 8424833
HEATER
OUT
IN
IN
OUT
L
N
Control SWITCHED
FUSED
SPUR
Minimum 500mm 230VAC MAINS
FROM FUSED or
BREAKERED
SOURCE
Ensure the heater is properly
earthed with the Fused Spur
Wiring Diagram
HEATER
OUT
IN
IN
OUT
L
N
Control SWITCHED
FUSED
SPUR
Minimum 500mm 230VAC MAINS
FROM FUSED or
BREAKERED
SOURCE
Ensure the heater is properly
earthed with the Fused Spur
Alternative
0240
Timing (Mins)
Installation contd..