Dinex DuraTherm 2011208 Installation and operation manual

DuraTherm™
Operating & Maintenance Manual
For Service Information, call 1-888-673-4639
Please provide the following information:
• Model number
• Serial number (from bottom of unit)
Table of Contents
Introduction ....................................................... 2
Freight Damage Claims..................................... 2
Applications and Use ........................................ 2
Safety ................................................................. 2
Installation ......................................................... 3
Operation Instructions ...................................... 4
User Interface .................................................... 4
Manager Options............................................... 5
Informational Warning ....................................... 6
Troubleshooting................................................. 6
Error Conditions ................................................ 7
Maintenance ...................................................... 8
Dinex Warranty .................................................. 9
Model: 2011208 (208V, 3-Phase)

2
INTRODUCTION
Congratulations! You have purchased the new
Dinex®DuraTherm™Induction Charger. Your
Dinex®DuraTherm induction heated base
system, when used within a controlled hot
food trayline process and covered with Dinex®
insulated domes, will keep hot plated food
satisfying for one hour or more from plating.
Please read this manual for helpful guidelines
on how to use your new equipment. Should you
have any questions concerning the equipment,
please call Dinex®Service at 1-888-673-4639.
! Important: For your safety, read and follow
all cautions, information, and warnings.
FREIGHT DAMAGE
CLAIMS
Your DuraTherm™Induction Charger was
carefully inspected and packed before leaving
our factory. The transportation company assumes
full responsibility for the safe delivery of this
equipment. Dinex®cannot assume responsibility
for damage or loss incurred in transit. Visible
damage or loss should be noted on the freight bill
and signed by the person making the delivery.
A freight claim should be filed immediately with the
transportation company. If damage is unnoticed or
concealed until the equipment is unpacked, notify
the transportation company immediately and tell
them you want to file a concealed damage claim.
This must be done within fifteen (15) days after
delivery was made. Be sure to retain all packing
materials and cartons.
! ATTENTION: Use of this symbol identifies
a potentially hazardous situation which, if
not avoided, may result in damage to the
machine or injury to the operator.
! CAUTION: If the product is used without
observing the information given under this
symbol, minor personal injury, or damage to
equipment may result.
! ATTENTION: Installation of this equipment
should be performed only by persons
qualified or licensed to install electrical
equipment.
• Adjustments and service work should
be performed only by qualified service
technicians.
• This equipment is intended for commercial
use only. Not for household use.
• Use of other than genuine Dinex®
replacement parts or service work
performed by other than authorized Dinex
service agents will void the warranty.
• Do not use corrosive cleaners on the
equipment. Use only mild detergents.
APPLICATION & USE
The equipment is for commercial use in the
foodservice industry. It provides maximum
induction heating compatible with Dinex®
bases. Use with Dinex®DuraTherm and
SmartTherm bases only.
SAFETY
The instructions contained in this manual
provide important guidelines for the
equipment user regarding correct and safe
installation. Particular attention should be
paid to the precautions given in various parts
of this manual. Do not attempt to repair this
equipment. Repairs must be performed by
authorized personnel only.
DuraTherm™

DuraTherm™
3
• Never use the equipment as a work surface
or cutting board.
• Do not attempt to heat anything other than
a Dinex base.
! IMPORTANT: Never place a DuraTherm base
or a SmartTherm base in a microwave oven!
! INFORMATION: This appliance is for
commercial use only and must be used
exclusively for the purposes prescribed.
! IMPORTANT: The following instructions
reduce the risk of fire, electrical shock, or
injury.
INSTALLATION
SET UP
1. Carefully remove any packing material
from the induction charger and check
loose packing material for small parts
or accessories. Inspect the charger for
concealed damage before placing packing
material aside. Keep the packaging until
you are confident with the equipment
performance.
2. The DuraTherm™ induction charger is
equipped with a locking plug. This plug
is part of a system that will protect you
from injury in the event of an electrical
malfunction inside the unit. Be sure the plug
is fully plugged into a matching socket that
is properly grounded.
! ATTENTION: DO NOT cut or break off the
larger angled prong on this plug, or change the
plug or power in any way. Doing so will create
a safety hazard and also void the warranty.
3. MAKE SURE THAT INCOMING
VOLTAGES MATCHES THE CHARGER
REQUIREMENTS. A product identification
label on the bottom of the unit specifies
the operating voltage, current, frequency,
phase, and maximum wattage of the
charger. Plugging or wiring the charger into
less voltage than the charger is rated may
significantly decrease the performance
of the unit or damage internal electrical
components.
4. Do not place foreign objects on the charger,
or between the Dinex base and the charger
surface. Foreign objects may heat within
the induction field and cause damage to the
charger surface and/or base.
5. Do not use any DuraTherm™charger that has
a damaged cord or plug. Consult the warranty
and follow the instructions for service.
6. Do not let the power cord touch hot surfaces.
7. The center of the charger may get hot to the
touch after hours of continuous use. Use
caution when loading and unloading bases.
8. The charger requires ample air flow to cool
the internal electronic components. Air is
pulled in from the bottom of the unit from
the front and sides, and exhausted towards
the rear of the unit. Assure that nothing
obstructs the airflow about all four sides of
the unit. Allow at least two inches from a
wall or partition.
9. A dedicated electrical outlet is recommended
for EACH DuraTherm™charger.
! IMPORTANT: Every installation site has
different electrical wiring requirement. Because
many different local codes exist, it is the owner
and installer’s responsibility to comply with all
federal, state, and local codes. Dinex®is not
responsible for any consequential damages,
either expressed or implied, as a result of

DuraTherm™
4
failure to comply with installation requirements.
! CAUTION: Please do not attempt to open
the charger or perform service of any
kind. This product can only be serviced
by a Dinex®Authorized Service Agent or
designated Dinex®personnel. Contact
Dinex®at 1-888-673-4639 for service
information.
! CAUTION: Any installation not matching the
requirements discussed in this manual will
automatically void the product’s warranty.
INSTALLATION
1. The DuraTherm™Charger can be installed
on top of a flat, level countertop or shelving,
being careful to maintain at least two
inches of clearance on all sides of the
charger for cooling. Do not place over
paper or loose material that may inhibit air
flow into the bottom air intakes. Consider
the Dinex®Induction Stand (Accessory
product) DXICTABLEM (Mobile with casters)
DXICTABLE (Not mobile).
2. The charger must be plugged into a
grounded 208V 3-phase, 20A receptacle.
Check rating plate on the charger to verify
correct voltage.
! IMPORTANT: Each charger should be
connected to its own dedicated circuit.
They should not be connected to circuits
sharing compressors or other heavy current
draw devices (i.e. plate heaters, steam
tables, etc.)
3. Do not move the DuraTherm™Charger when
it is electrically connected.
4. Two grease filters are mounted to the
bottom of the unit. Assure each is seated
and free of excessive debris or grease.
OPERATION
INSTRUCTIONS
DuraTherm Induction System
1. Make sure that your DuraTherm™Charger
is plugged into an energized circuit
as described in the previous section.
This should be a dedicated circuit, not
shared with any devices utilizing motors,
compressors, or components requiring a
heavy current draw.
USER INTERFACE:
POWER key will turn the unit on and off.
SELECT key will be used to reset error
conditions, clear informational messages, and
select or set options.
UP/DOWN arrow keys (these are not
embossed – just right of the SELECT key) are
used to move among Manager Options in the
OPTIONS menu.
LCD Info Center provides feedback on the
status of bases charging and equipment
operation.
2. The DuraTherm™Charger is turned on by
pressing the POWER button on the left front
of the switch panel. The LCD Info Center
will display “Waiting for base…” indicating
the DuraTherm™Charger is turned on and
ready for use.
LCD
Info Center

DuraTherm™
5
3. Place a Dinex®DuraTherm or SmartTherm
base on the charger within the positioning
rails. Assure the base is seated flat on
the top. The charger will beep once as it
recognizes the base.
4. The LCD Info Center will display “Heating
Base” once it has begun charging. A status
bar at the bottom of the screen will continue
to fill in to show the progression of charge.
If the base is removed prior to the status
bar being completely filled the base will not
be fully charged and may result in a lower
delivery temperature.
! INFORMATION: You will hear three loud
“BEEPS” if you remove the base before it is
fully charged.
! INFORMATION: To prevent overheating
a base, the charger will not reheat a base
until sufficient cooling time has elapsed –
even if the base was removed before the
initial charge completed. “Reheat Later”
will appear in the LCD if insufficient time
has elapsed between charges.
5. If the phrase “Waiting for base…” still
appears after placing a base on the charger,
remove the base and reposition – assuring
the base is seated flat to the top, and within
the positioning rails.
6. After the status bar is completely filled the
charger will display “Base Ready” and will
beep indicating that base is at full charge.
A DuraTherm base will usually charge
completely in 15 seconds. A SmartTherm
base will usually charge in 10 seconds. Only
a DuraTherm base will provide maximum
performance. Low incoming voltage may
increase change time.
INFO: Fluctuations in voltage may affect
heating time.
7. If the charger sees no activity for an
extended period of time, it will beep 2 times
and go into “Sleep” mode to conserve
power. This will be indicated by the display
reading “Power Save. Press any key to
return to previous mode”. Press any key to
exit “Sleep” mode.
8. Power off the DuraTherm™Charger by
depressing the POWER button.
MANAGER OPTIONS
Your DuraTherm™ charger can be set
to display in English, Spanish, or French
languages. You may also choose to disable
information alerts (see below). These options
may be changed through the OPTIONS menu.
1. The unit must be powered down with
DINEX®in the display. Press and hold the
SELECT key for 7 seconds.
2. Release the SELECT key, and within two
seconds, press the POWER key once. The
OPTIONS menu should now be displayed.
3. Use the UP/DOWN arrow keys to move the
caret symbol (>) to the desired option, and
press SELECT.
2 1
SET OPTIONS
> Set Language
Ignore Warnings
Set LCD Contrast
Reset Defaults
Exit

DuraTherm™
6
4. The “Set Language”, “Ignore Warnings”,
and “Set LCD Contrast” options will bring
up sub-menus where you may select the
desired mode. “Set Languages” allows
you to choose between displaying English,
Spanish, or French. “Ignore Warnings”
allows you to suppress the display of
certain informational warning messages
(for example, you may suppress the display
of “Low Voltage” warnings during times of
heavy electrical demand where voltage on
power lines may sag).
5. Choose “Exit” to back out of the displayed
menu.
6. At any time, you may also press the POWER
key to cycle the unit back into normal
operation.
INFORMATIONAL
WARNING
An informational warning messages may
appear in the course of operation. Make note
of and correct the condition as soon as is
practical. Press the SELECT key to continue
normal operation.
1. Warning! Low voltage condition exists.
Performance may suffer. Press SELECT to
continue.
This indicates that the unit senses the line
voltage has dropped where charge times
may be adversely affected. The unit will
pause operation until SELECT is pressed.
No harm will result if you continue to
operate the unit. If these warnings become
excessive (for example, during periods
of high electrical demand), they may be
suppressed from the OPTIONS menu.
TROUBLESHOOTING
! IMPORTANT: Safety-relevant parts should be
replaced with original factory parts only. Any
defective parts must be removed and replaced
by a qualified service technician authorized by
Dinex®. Should you require service please call
the Dinex®Hotline at 1-888-673-4639. In order
for the warranty to remain valid, work must be
authorized by Dinex®prior to being performed.
The Dinex®DuraTherm™Charger is a very
intelligent device. Built in diagnostics can
help you to determine the cause of most
problems. The following section explains how
to determine if you are experiencing a problem
and what can be done to correct the problem.
This information can be very helpful if you are
calling our Customer Service department to
report any operational difficulties.
1. Errors are displayed in easy to understand
text on the LCD Screen.
2. If an error occurs, press SELECT to clear
the error and try again. Or remove the base
from the charger and turn the charger OFF
and back ON again.
3. If an error persists, remove the base from
the charger, turn the power off and unplug
the charger, wait 5 seconds and then plug
the charger back in and turn the charger on
by pressing the “POWER” button.
4. When the display reads “Waiting For
Base”, put the base back on the charger to
continue charging. Make sure that the base
is properly positioned on the charger.
5. If the base still doesn’t heat, set it aside and
take it out of service. If other bases exhibit
similar conditions note the error code and
call Dinex®Service.

DuraTherm™
7
ERROR CONDITIONS
Error Codes will be indicated by a message
on the LCD Info Center. If there is more
than one error condition, the display will
alternate between the error messages. It will
continuously repeat this cycle until the errors
are reset. Error messages may be reset by
pressing SELECT.
If the error persists, turn the charger off, unplug
the power cord, wait 5 seconds, and plug it in
again. If the error still persists, turn the charger
off and call the Dinex®Service Department at
1-888-673-4639.
Message: Error! RFID Communications
problem. Possible bad base. 1/2
Condition: RFID read/write problem.
Check: Possible bad electronics chip on
the base, or RF antenna/reader
problems. If isolated to one or
more bases, set them aside and
call service about those bases. If
error issued with many bases, call
service about the charger.
Message: Error! Incompatible base. 3
Condition: Base draws too much current.
Check: Object being heated is not a
Dinex®base or internal charger
problem.
Message: Error! Unit overheat! Check fan
operation. Allow to cool. 4
Condition: Internal unit temperature too hot.
Check: Fan stalled, restricted air flow, or
ambient operating temperature too
hot. Possible internal electronics
fault. Verify grease filters are not
blocked and unrestricted airflow
about the bottom of the unit. Listen
for fan operation. If error persists,
call Dinex®service.
Message: Error! Incoming voltage too high. 6
Condition: Line voltage measures greater
than 110% of unit rated voltage.
Check: Line voltage spikes, possible
voltage sensing electronics
fault. Have maintenance verify
line voltage. Recalibrate to
your line conditions (for trained
maintenance personnel only):
1. Measure voltage across two phases of
power with a voltmeter (typically about
208V)
2. Set unit to OFF position – with DINEX in the
display.
3. Press and hold the DOWN arrow for 7
seconds.
4. Release, and within 2 seconds, press
POWER once. The CALIBRATION screen
should display.
5. Using arrow keys, move caret to Set V
Offset. Press SELECT.
6. Using UP/DOWN arrow keys, dial in the
measured phase voltage. Press SELECT.
7. Please do not use the reset logs selections,
this will clear valuable stored information
should your unit require additional service.
8. Select EXIT or cycle the POWER button.
Message: Critical Error! Unit requires service.
Call Dinex (888) 673-4639. 7
Condition: Inverter drawing power when
commanded off.
Check: Possible internal electronics fault.
Unplug, wait 5 seconds, and
replug unit. If error persists, call
Dinex®service.
Message: Error! Check incoming voltage!
If problem persists, Call Dinex
Service (888) 673-4639. 8
Condition: Poor power quality.
Check: Major line voltage sags (severe
brown out) or internal electronics
fault. Have maintenance verify line

DuraTherm™
8
voltage. Unplug, wait 5 seconds,
and replug unit. If error persists,
call Dinex®service.
Message: Critical Error! Time corrupted. Call
Dinex Service (888) 673-4639. 9
Condition: Internal system clock time
incorrect.
Check: System clock backup battery
dead, system clock electronics
fault, or electronic noise spike.
Cycle POWER button. Unplug,
wait 5 seconds, and replug unit. If
error persists, call Dinex®service.
Message: Critical Error! RFID failure. Call
Dinex Service (888) 673-4639. 15
Condition: RFID reader-to-host
communications failure
Check: RFID reader fault, internal power
supply electronics fault, CPU
electronics fault, bad internal
interconnect. Call Dinex®service.
Message: Critical Error! Electronics platform
fault. Call Dinex Service
(888) 673-4639. 16
Condition: CPU memory corrupt.
Check: Internal CPU fault or electrical
noise spike. Cycle power. If error
persists, call Dinex®service.
Message: Reheat later. (Clears when base is
removed).
Condition: 1) Insufficient base cooling
time or 2) Base time stamp has
corrupted information – but the
unit automatically repaired it.
Check: Set base aside for reuse after one
or two hours.
MAINTENANCE
DURATHERM™ CHARGER CLEANING
INSTRUCTIONS
1. Unplug the charger before cleaning. Do
not submerge the charger in water. Do not
splash or pour water onto the charger’s
control panel or into intake/outlet vents.
Possible shock hazard may result and the
charger may be damaged.
2. The heating surface is a high strength
composite material. Please use appropriate
care in handling and cleaning
3. Do not use steel wool or abrasive cleaners
or chlorinated cleaners on the charger.
4. Wipe the entire charger off with a damp
cloth and mild detergent. Dry the charger
before connecting it to its electrical source.
GREASE AND AIR FILTERS
1. Weekly, inspect the two bottom-mounted
grease filters for build-up of debris.
2. Slide filters out or their holders and run
under faucet or in dishwasher to clear of
debris and grease. FILTERS MUST BE
DRY BEFORE SLIDING BACK INTO THEIR
HOLDERS. DO NOT OPERATE YOUR
DURATHERM™ WITHOUT PROPERLY
FITTED, DRY FILTERS.
3. Replacement filters may be obtained by
calling Dinex®service.
WARNING: Never spray, wash or use excessive
water on the charger. Before cleaning it is
absolutely necessary to unplug power plug.
• Do not use the charger if the top is broken
or cracked.

DuraTherm™
9
• Never use the charger as a work surface or
cutting board.
• Never attempt to heat anything other than a
Dinex®8x1-Series Smart base.
DURATHERM BASES
• DX1411003- Onyx
• DX1411061 – Cranberry
• DX1411050 - Midnight Blue
• DX1411084 – Sage
• DX1411031 – Latte
• DX1411044 – Steel Grey
AFTER WASHING BASES, STORE IN DINEX®
DRYING RACK.
• DXIBDRS/90 - HOLDS 90 INDUCTION
BASES
• DXIBDRS/180 - HOLDS 180 INDUCTION
BASES
• DXIBDRS/270 - HOLDS 270 INDUCTION
BASES
DINEX®WARRANTY
These Warranties cover the following Dinex
International, Inc. (“Dinex”) equipment products
(the “Warranted Products”):
• Rethermalization Equipment Products
• Induction Heating System Products
(excluding Induction Bases covered under
separate warranty )
• Milk Cooler Products
• Ice Cream Freezer Products
• Air Curtain Refrigerator Products
• Blast Chiller Products
• Hot/Cold Food Counter Products
• Plate, Rack and Tray Dispenser Products
• Plate Heater Products
• Base Heater Products
• Drying and Storage Rack Products
• Starter Station Products
• Conveyor Products
• Tray and Other Cart Products
Warranted Products also includes any other
Equipment System Products identified on Dinex’s
website (www.dinex.com) from time to time.
Standard Warranty. Except as indicated
otherwise below, Dinex warrants that the
Warranted Products will be free from defects in
title, material and workmanship under normal
use and service and will perform substantially
in accordance with Dinex’s written technical
specifications for the Warranted Products
(as such specifications exist on the date the
Warranted Products are shipped) (the “Product
Specifications” ) . This warranty covers
both parts and labor and is available only to
end-users (the “Customers”) that purchase
the Warranted Products from Dinex or its
authorized distributors. For the purpose of
these warranties, a defect is determined by
Dinex after its good faith investigation.
Dinex Software. In addition to the other
warranties set forth herein, with respect to
Dinex’s licensed software, Dinex warrants that
it has the right to license or sublicense the
software to Customer for the purposes and
subject to the terms and conditions set forth in
Dinex’s standard terms and conditions.
Supplies and Accessories. Dinex’s warranty
for its supplies and accessories that are
shipped with Warranted Products is covered
by a separate warranty statement, which is
available at www.dinex.com.
Services. Dinex warrants that any service it
provides to Customer will be performed by
trained individuals in a workmanlike manner.
DURATION
Dinex provides a one year warranty for the
Warranted Products. The warranty period
begins on the date the Warranted Products

DuraTherm™
10
are shipped to Customer. The warranty period
for any Warranted Product or part furnished to
correct a warranty failure will be the unexpired
term of the warranty applicable to the repaired
or replaced Warranted Product .
REMEDIES
If Customer promptly notifies Dinex of
Customer’s warranty claim and makes the
Warranted Product available for service, Dinex
will, at its option, either repair or replace (with
new or exchange replacement parts) the non-
conforming Warranted Product or parts of the
Warranted Product. With respect to Dinex’s
licensed software, Dinex will, at its option,
either correct the non-conformity or replace
the applicable licensed software. Warranty
service will be performed without charge from
8:00 a.m. to 5:00 p.m . E S T, Monday - Friday,
excluding Dinex holidays, and outside those
hours at Dinex’s then prevailing service rates
and subject to the availability of personnel.
With respect to Dinex’s warranty for the
services it provides to Customer, Customer’s
exclusive remedy shall be the re-performance
of the services by Dinex. The foregoing
remedies are Customer’s exclusive remedies
and Dinex’s sole liability for warranty claims
under this warranty statement. This exclusive
remedy shall not have failed of its essential
purpose (as that term is used in the Uniform
Commercial Code) as long as Dinex remains
willing to repair or replace defective Warranted
Products within a commercially reasonable
time after being notified of Customer’s warranty
claim.
LIMITATIONS
THESE WARRANTIES ARE EXCLUSIVE AND IN
LIEU OF ALL OTHER WARRANTIES, WHETHER
WRITTEN, ORAL, EXPRESSED, IMPLIED OR
STATUTORY. EXCEPT AS PROVIDED HEREIN,
NO EXPRESS OR IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO IMPLIED
WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE,
QUIET ENJOYMENT, SYSTEM INTEGRATION
AND DATA ACCURACY, WILL APPLY. THERE
ARE NO WARRANTIES THAT EXTEND BEYOND
THOSE DESCRIBED IN THIS DOCUMENT
AND NO PRIOR STATEMENTS BY ANY OF
DINEX’S REPRESENTATIVES SHALL MODIFY
OR EXPAND THESE WARRANTIES. DINEX AND
DINEX’S AFFILIATES AND REPRESENTATIVES
SHALL HAVE NO LIABILITY TO CUSTOMER
FOR (1) ANY SPECIAL, PUNITIVE, INCIDENTAL,
INDIRECT OR CONSEQUENTIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH
THE WARRANTED PRODUCTS, REGARDLESS
OF WHETHER SUCH LIABILITY SHALL BE
CLAIMED IN CONTRACT, TORT, EQUITY
OR OTHERWISE, (2) ANY ASSISTANCE NOT
REQUIRED UNDER DINEX’S QUOTATION
OR (3) ANYTHING OCCURRING AFTER THE
WARRANTY PERIOD ENDS.
DINEX’S STANDARD WARRANTIES ONLY
APPLY TO END-USER-PURCHASERS
LOCATED IN THE UNITED STATES AND
CANADA. ANY SALE TO END-USER-
PURCHASERS OUTSIDE THE UNITED
STATES AND CANADA WILL BE SUBJECT
TO COMMERCIAL TERMS SPECIFICALLY
AGREED BY DINEX AND THE END-USER
PURCHASER. DINEX MAKES NO WARRANTY,
EXPRESS OR IMPLIED, TO END-USER-
PURCHASERS OUTSIDE THE UNITED
STATES OR CANADA UNLESS OTHERWISE
EXPRESSLY AGREED IN WRITING.
These warranties do not apply to, and Dinex
shall not have any obligation to Customer
hereunder with respect to, any warranty claim
resulting from or arising out of: (i) normal wear
and tear; (ii) damage caused by shipping or
accident; (iii) damage caused by improper
installation, repair or alteration not performed
by Dinex; (iv) the use of the Warranted Product
in combination with any software, tools,
hardware, equipment, supplies, accessories or

DuraTherm™
11
any other materials or services, not furnished
by Dinex or recommended in writing by Dinex;
(v) the use of the Warranted Product in a
manner or environment, or for any purpose,
for which Dinex did not design or license it, or
inconsistent with Dinex’s recommendations or
instructions on use including, but not limited
to, power supply requirements identified in
Product Specifications; (vi) any alteration,
modification or enhancement of the Warranted
Product by Customer or any third party not
authorized or approved in writing by Dinex;
(vii) Warranted Product manufactured to meet
customer specifications or designs; or (viii) any
accessories or supplies or other equipment
or products that may be delivered with the
Warranted Product.
In addition, these warranties do not cover: (i) Any
defect or deficiency (including failure to conform
to Product Specifications) that results, in whole
or in part, from any improper storage or handling,
failure to maintain the Warranted Products in the
manner described in any applicable instructions
or specifications, inadequate backup or virus
protection or any cause external to the Warranted
Products or beyond Dinex’s reasonable control,
including, but not limited to, power failure and
failure to keep Customer’s site clean and free
of dust, sand and other particles or debris; (ii)
the payment or reimbursement of any facility
costs arising from repair or replacement of
the Warranted Products; (iii) any adjustment,
such as alignment, calibration, or other normal
preventative maintenance required of Customer;
and (iv) expendable supply items.
Notes:

DuraTherm™
1212

DuraTherm™
©2016 Carlisle FoodService Products | Oklahoma City, OK 73131 | www.carlislefsp.com | 800.654.8210
Table of contents
Other Dinex Batteries Charger manuals
Popular Batteries Charger manuals by other brands

Pro Charging Systems
Pro Charging Systems 1250OB Safety, installation and operating instructions

Anslut
Anslut 006249 operating instructions

Texas Instruments
Texas Instruments BQ25120A manual

E-FLITE
E-FLITE Celectra EFLUC1007 instruction manual

ENEL
ENEL JuiceBox Next Gen install guide

Kärcher
Kärcher BC 1/2 manual