DKS 1838 Access Plus Operating instructions

UL Listed
Copyright 2009 DoorKing, Inc.All rights reserved.
Copyright 2016 DoorKing, Inc.All rights reserved.
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
Circuit Board
Serial Number
and Revision Letter:
Installation/Owner’s Manual
1838 Access Plus
1838 Access Plus
1838 Access Plus
Use this manual for circuit board 1970-010 Revision U or higher.
Control a main door, gate and six additional RS-485 entry points.
PC Programmable Access Control System
Download ACCESS PLUS ACCOUNT MANAGER Software FREE at:
http://www.doorking.com/accessories/access-plus-software
1838-066-E-12-16

1838-066-E-12-16
2Quick Guide - 1
J1 1
2
3
4
5
6
7
8
J4
1970-010
Relay 1
(Access Control Device)
Relay 2
(Access Control Device)
Input Power
(Transformer)
DO NOT
use 24V.
Optional Back-Up
Battery Power
Emergency
and/or Postal
Entry Switch
1. Phone In (Negative - Ring)
2. Phone In (Positive - Tip)
3. Ground (Required)
4. Not Used
5. Not Used
6. Not Used.
7. Switch Input Relay 1. A switch closure across terminals 7 & 9
will activate relay 1 for its programmed strike time.
8. Switch Input Relay 2. A switch closure across terminals 8& 9
will activate relay 2 for its programmed strike time.
9. - 12 VDC Battery Negative. Also Common for terminals 7 & 8.
10. + 12 VDC Battery Positive.
11. Relay 1 Normally Open
12. Relay 1 Normally Closed
13. Relay 1 Common
14. Relay 2 Normally Open
15. Relay 2 Normally Closed
16. Relay 2 Common
17. 16.5 VAC Input Power
18. 16.5 VAC Input Power
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
WARNING
Maximum
input voltage to terminals
9 and 10 is 14.5 Volts DC.
BATT
CHARGE
BATT CHARGE LED: When
battery is connected to 9
and 10, Green LED will
light when charging and
turn OFF when charged.
Over Voltage Power Note: OV LED will light up if too much power is applied to circuit board.
OV
QUICK GUIDE: Terminals & LED Descriptions
SPEAKER
VOL
MIC VOL
KEYPAD
MASTER
CODE
1970-010
1112345678910
J2
J1
J3
1970-010
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Microphone
Gain Adjust
MODEM / TCP ENB
RJ-45
Connector
(Cat5)
LAN CONNECTION DATA TRANSMIT
LAN DOWN
RS-485 RX
PHONE LINE
IN USE
ON
ON
1972-010
SW1
SW2
MODEM / TCP ENB
1
2
3
4
5
6
7
8
J1
J4
Speaker
Volume
Adjust
RS-485 RX - Green LED indicates that the system is on-line and scanning the RS-485 devices.
BAD DNS - Yellow LED indicates an email server problem, rejecting the mail server.
LAN DOWN - Red LED indicates a problem with the LAN. IP or Gateway (router) down or wrong gateway IP address.
PHONE LINE IN USE - Yellow LED indicates that the phone line is being used (dial-out, call forwarding, etc.).
LAN CONNECTION - Green LED indicates that the wire connection from the unit to the computer or router is good.
DATA TRANSMIT - Yellow LED indicates that the TCP / IP connection is transmitting data or sending an email.
SW1 - Modem/TCP Enable - Turning SW1 Off disables the modem and TCP / IP, but will speed up programming from the keypad.
SW2 - Termination Switch - Only used when RS-485 access control devices are being used (See section 1.9.1).
Interface Board
18-PIN Terminal
8-PIN
Terminal
J1
J1
J1
J1
J1
J1
J1
J1
J1
RS-485 RX
TERMINATION
LAN DOWN
BAD DNS
LAN
CONNECTION
DATA
TRANSMIT PHONE LINE
IN USE
OV
RS-485 DATA A (+)
RS-485 DATA B (-)
RS-485 Common
RJ-45
Jack
(Cat5)
Terminals 4-8
are not used
with the 1838.
(Optional - Phone modem
programming or remote
touch-tone phone control only)
Phone In
(Twisted Pair)
Wireless
Adapter
OR

1838-066-E-12-16 3
Quick Guide - 2
NOT Programmable from Software.
Program from System Keypad ONLY.
NO Master Code
Programmed
Program a Master Code
Section 2.1 Programming Master Code
2.117 Press Master
Code Button
N / A
N / A
Restore Factory Settings
Erase Transaction Log
Section 2.8 Miscellaneous
2.8.1
2.8.2
26
26
*9 0
*9 1
Empty
Empty
Empty
Time and Date Calendar Chip Programming
Automatic Relay Activation Time Zone Programming (Up to 4 zones)
Access Code Time Zone Programming (Up to 4 zones)
Section 2.7 Time Functions
2.7.1
2.7.5
2.7.6
25
25
26
*3 3
*3 5
*3 6
192.168.001.030
255.255.255.000
192.168.001.001
01030
0
Set the Unit’s IP Address (reboot required)
Sub-Net Mask (reboot required)
Set the Gateway (Router) IP Address (reboot required)
Set the Port Number (reboot required)
Enable / Disable TCP / IP Support - System Reboot
Section 2.3 Programming Network Setup for a Computer
2.3.1
2.3.2
2.3.3
2.3.4
2.3.5
19
19
20
20
20
*5 1
*5 2
*5 3
*5 6
*5 0
Section 2.6 Access Codes for Access Control Devices
Empty
N / A
N / A
2.6.4
2.6.5
2.6.6
24
24
24
*7 0
*7 1
*7 2
Device Access Code Programming “Time Zone Restricted”
Delete a Device Access Code
Delete All Device Access Codes for Same Type of Device
Relay Strike Time
Tone Open Numbers
Answer Incoming Call on X Rings (Phone Line Required)
1 Sec
Relay 1: 9 87 6
Relay 2: 5 4 3 2
Relays 3-8Not Set
06 (6 Rings)
Section 2.4 System Parameters Programming
2.4.7
2.4.8
2.4.9
23
23
23
* 0 3
*0 5
* 1 8
Page # Factory SettingsSection Command
Note: Program section numbers have been intentionally skipped that DO NOT apply to the 1838Access Plus system in this manual. This allows ALL of the
Access Plus manuals to remain in sync with each other when referencing programming numbers.
Quick Reference Table

1838-066-E-12-16
4
SPECIFICATIONS
Features
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such
revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this
manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc.
•IP Addressable – the 1838Access Plus can be programmed from your PC using the DoorKing programming software via a
LAN or WAN connection. It can also be programmed via the built-in modem (Central Office phone line required).
•The 1838is an access controller that can control up to six (6) entry points via card, keypad or RF devices using RS-485
communication protocol. In addition, two (2) additional auxiliary relays are built into the system and are time zone controlled.
These relays can be utilized to unlock or open a door or gate at preprogrammed times.
•100 card / transmitter / keypad codes.
•Holiday schedule.
•500 event transaction buffer.
•Built-in clock / calendar.
•Four hold-open time zones.
•Entry code time zones.
For 1838 Access Plus with circuit board
1970-010 Rev U or higher ONLY.
Both Boards Together - 1970-010
Included with the system is an extra random keyed cabinet lock. If desired, for added security against
unauthorized entry into the system, the standard lock may be replaced with the random lock.
Note: DoorKing cannot replace this specific lock or keys if lost.
SPEAKER
VOL
MIC VOL
KEYPAD
OV
MASTER
CODE
1970-010
18
11
12345678910
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
J2
J1
MODEM
1972-010
SW1
1
2
3
4
5
6
7
8
BAD
DNS
LAN
DOWN
RS-485
RX
J4
ON
J1
SW2
ON
0
123
456
789
Interface Board
Control Board
DOORKING
Inglewood, Ca 90301
Model # 1800 Series
Serial#
Complies F.C.C. Part 68
F.C.C. Registration #
DUF6VT-12874-OT-T
Ringer Equiv. 0.0A
Jack USOC RJ11C orW
ACCESS CONTROL
SYSTEM UNITS
CONFORMS TO ULSTD 294
OUTDOOR USE/ WET
DOO
RKI
N
G
®
,
I
NC
.
MADE
IN
USA
PARTNUMBERREVSERIALNO.
DOO
RKI
N
G
®
,
I
NC
.
Mfg. in U.S.A.
Access Control Solutions
Since 1948
This productis manufactured under one
or more of the followingU. S. Patents.
OTHERPATENTS PENDING
DOORKINGINC.,INGLEWOOD CA
PatentNo.DatePatent No.Date

1838-066-E-12-16 1
SECTION 1 - INSTALLATION
1.1 Remove the Control Board
1.2 Install Enclosure
1.3 Mounting Dimensions
1.4 16.5 VAC Power Wiring ONLY!
1.5 Grounding and Surge Suppression
1.6 “OPTIONAL” Telephone Line Wire
1.7 Wire 1838 to “OPTIONAL” Telco Line
1.8 Main Terminal Description
1.9 1838 Interface Board
1.9.1 RS-485 8-Pin Connector Description
RS-485 Daisy Chain Wiring
RS-485 Configurations
1.9.2 Network Connections
1.9.3 Phone Modem Connection
SECTION 2 - PROGRAMMING
2.1 Programming the Master Code
2.2 Programming Methods
2.3 Programming the Network Setup for a Computer
2.3.1 Set the 1838IP Address (reboot required)
2.3.2 Sub-Net Mask (reboot required)
2.3.3 Set the Gateway (Router) IP Address (reboot required)
2.3.4 Set the Port Number (reboot required)
2.3.5 Enable / Disable TCP / IP Support - System Reboot
2.4 System Parameters Programming
Programming from the System Keypad
Programming from a Touch-Tone Telephone
Quick Reference Table
2.4.7 Relay Strike Time
2.4.8Tone Open Numbers
2.4.9 Answer Incoming Call on X Rings
2.6 Access Codes to Operate Access Control Devices
2.6.4 Device Access Code Programming “Time Zone Restricted”
2.6.5 Delete a Device Access Code
2.6.6 Delete All Device Access Codes for the Same Type of Device
Quick Guide: Terminals and LED Descriptions
Quick Reference Table
SPECIFICATIONS
Important Notices FCC - United States, DOC - Canada
General Information Installation Guidelines and Safety Information
5
5
6
7
8
8
9
10
11
11
11
12
13
14-15
16
17
17
18
19
19
19
20
20
20
21
21
21
22
23
23
23
24
24
24
24
Quick Guide - 1
Quick Guide - 2
Previous Page
3
4
TABLE OF CONTENTS

1838-066-E-12-16
2
TABLE OF CONTENTS
25
25
25
26
26
26
26
27
27
27
28
28
28
28
28
29
30
31
32-34
2.7 Time Functions
2.7.1 Time and Date Calendar Chip Programming
2.7.5 Automatic Relay Activation Time Zone Programming (Up to 4)
2.7.6 Access Code Time Zone Programming (Up to 4)
2.8 Miscellaneous
2.8.1 Restore Factory Settings
2.8.2 Erase Transaction Log
SECTION 3 - USER CONTROLS
Interface Board LED Status
System Keypad
3.1 Remote Touch-Tone Phone Operation
3.2.1 Remote Programming
3.2.2 Remote Relay Activation
SECTION 4 - MAINTENANCE
4.1 Troubleshooting
4.2 Troubleshooting Table
4.3 1838 Access Plus Wiring Schematic
4.4 Accessories
4.5 Programmed Information Log Sheets
Master Code, Relays, Access Codes and Time Zone Log Sheets; Access Code Log Sheets

1838-066-E-12-16 3
FCC – United States
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC
Rules and Regulations. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communica-
tions. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
FCC Registration Number: DUF6VT-12874-OT-T
DOC - Canada
The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment
meets certain telecommunications network protective, operational, and safety requirements. The Department does not guaran-
tee the equipment will operate to the users satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecom-
munications company. The equipment must also be installed using an acceptable means of connection. The customer should be
aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any
repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications
company cause to request the user to disconnect the equipment.
Users should ensure, for their own protection, that the electrical ground connections of the power utility, telephone lines, and
internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural
areas.
CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspec-
tion authority, or electrician, as appropriate.
DOC Registration Number: 1736 4507 A
Notice:
The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone
loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices
subject only to the requirement that the sum of the load numbers of all the devices does not exceed 100.
Notice:
DoorKing does not provide a power transformer on units sold into Canada. Use only transformers that are CSA listed to power
the telephone entry system. The Access Plus system requires a 16.5-volt, 20 VA transformer.
Important Notices

1838-066-E-12-16
4
1. If the clear floor space allows only forward approach to the system, the maximum high forward reach allowed is
48inches above grade to the top of the keypad.
2. If the high forward reach to the system is over an obstruction of greater than 20 inches but less than 25 inches,
the maximum high forward reach allowed is 44 inches above grade to the top of the keypad.
3. If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach shall
be 54 inches above grade to the top of the keypad.
4. If the high side reach is over an obstruction of 24 inches or less, the maximum high side reach allowed is 46
inches above grade to the top of the keypad.
•Prior to beginning the installation of the telephone entry system, we suggest that you become familiar with the
instructions, illustrations, and wiring guidelines in this manual. This will help insure that you installation is performed in
an efficient and professional manner.
•The proper installation of the telephone entry panel is an extremely important and integral part of the overall access
control system. Check all local building ordinances and building codes prior to installing this system. Be sure your
installation is in compliance with local codes.
•When used to control a door or pedestrian gate, try to locate the telephone entry system as near as possible to the entry
point. The unit should be mounted on a rigid wall to prevent excessive shock and vibration from closing doors or gates.
Continuous vibration and shock from slamming doors or spring-loaded pedestrian gates will damage the circuit board.
Under no circumstances should the unit be mounted directly to a moving door or gate.
• ADA mounting requirements for door control. The requirements below apply only when the telephone entry system is
being used to control entry through a public door only. If this system is used to control entry through a vehicular gate or
private entrance, the dimensions noted below do not apply.
•When used to control a vehicular gate with an automatic gate operator, the telephone entry system must be
mounted a minimum of ten (10) feet away from the gate and gate operator, or in such a way that a person cannot
operate the entry system and/or touch the gate or gate operator at the same time.
•Be sure that the system is installed so that it is not directly in the traffic lane. Goose neck mounting post and kiosks
work well for these type systems. When planning where to locate the system, take into consideration traffic lane layouts,
turn around lanes for rejected access, conduit runs, power availability, etc.
•Environmental factors must also be taken into account. Surface mount units are designed for direct outdoor
installations, however it is preferable to protect them from direct exposure to driven rain or snow whenever possible.
Flush mount units must be protected from direct exposure to the elements.
•This telephone entry system contains a number of static sensitive components that can be damaged or destroyed by
static discharges during installation or use. Discharge any static prior to removing the circuit board from the lobby panel
by touching a proper ground device.
•Instruct the end user to read and follow these instructions. Instruct the end user to never let children play with or
operate any access control device. This Owner’s Manual is the property of the end user and must be left with them
when installation is complete.
General Information

1838-066-E-12-16 5
SECTION 1 - INSTALLATION
Installation of the Access Plus Access Control System involves the installation of the hardware and the wiring of these compo-
nents. Be sure that all dirt, metal or wood debris is removed from inside after mounting it. Any debris inside could damage the
control board and cause the 1838to malfunction during operation.
When the 1838is used to control a vehicular gate with an automatic gate operator, it must be mounted a
minimum of ten (10) feet away from the gate and gate operator, or in such a way that a person cannot
operate the 1838and/or touch the gate or gate operator at the same time.
1.1 Remove Control Board
1. Unlock and open the door.
2. Disconnect the keypad plug and
door accessories plug from the
control board.
3. Remove the 4 screws from board.
Carefully remove control board.
Keep the control board in a protected
area during the mounting installation.
4. Mount enclosure, see next page for
specific mounting of the 1838
enclosure.
CAUTION The control board contains
static sensitive components. Discharge
any static electricity from your hands
by touching a proper ground device
before removing the control board.
WARNING
Included with the system is an extra random keyed cabinet lock. If desired, for added security against unauthorized entry into the system,
the standard lock may be replaced with the random lock. Note: DoorKing cannot replace this specific lock or keys if lost.
SPEAKER
VOL
MIC VOL
KEYPAD
OV
MASTER
CODE
1970-010
18
11
12345678910
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
J2
J1
J3
J3
J
MODEM
1972-010
SW1
1
2
3
4
5
6
7
8
BAD
DNS
LAN
DOWN
RS-485
RX
J4
ON
J1
SW2
ON
0
123
456
789
Keypad
Plug
Door
Accessories
Plug
Enclosure

1838-066-E-12-16
6
Surface
Knock-Out
Conduit
Enclosure
Note: Enclosure door not
shown in illustration to better
clarify mounting holes.
Use appropriate hardware to
secure enclosure to the
surface (not supplied).
1.2 Install Enclosure
1. Mount the enclosure using the mounting holes provided in the corners (see section 1.3 for dimensions). Be sure that
mounting screws (Not supplied) do not protrude into the enclosure where they could cause a short on the back of the circuit
board. Make any necessary conduit connections through the bottom of the enclosure using the existing conduit knock-outs.
DO NOT make any new conduit holes in the enclosure.
2. Route all wiring through conduit into enclosure.
3. Clean out the enclosure. Make sure that all dirt, metal and/or wood debris is removed.
4. Re-install circuit board back into the enclosure (Reverse section 1.1 steps). Use the wiring schematics in the back of this
manual to help re-install the circuit board if necessary. DO NOT apply any power at this time.

1838-066-E-12-16 7
1.3 Mounting Dimensions
If used to control a door or pedestrian gate, try to locate the access controller as close as possible to the entry point. The unit
should be mounted on a rigid wall to prevent excessive shock and vibration from closing doors or gates. Continuous vibration
and shock from slamming doors or spring-loaded pedestrian gates will damage the circuit board. Under no circumstances
should the unit be mounted directly to a moving door or gate.
10.25”
10”
12” 4”
Bottom View
Side ViewBack View Front View
WARNING! If the 1838is used to control a
vehicular gate with an automatic gate operator,
the entry system must be mounted a minimum of
ten (10) feet away from the gate and gate
operator, or in such a way that a person cannot
operate the entry system and touch the gate or
gate operator at the same time.
DoorKing recommends replacing the Standard Key Lock with the “Random” Key Lock that is included.
.25” Dia. Mounting Holes
Mounting Hole Mounting Hole
10.75”
9”
.875” Dia 1.125” Dia 2.125” Dia
1.5”
3.75”
8.25”
10.5”
6”
2”
12.25”
Use appropriate hardware to secure
enclosure to surface (not supplied).

1838-066-E-12-16
8
1.4 16.5 VAC Power Wiring ONLY!
The 1838operates ONLY on 16.5 VAC. DO NOT power the unit with 24 volt AC power. Use the supplied power transformer, 16
VAC, 20 VA (or U.L. listed equivalent) to power the system. DO NOT power any other devices (electric strikes, magnetic
locks, etc.) from the unit’s power transformer. See table below for wire run distances.
Power Interruption Note: The Time
and Date calendar chip (Section 2,
2.7.1) in the 1838will keep time for
approximately 48hours if power to
the system is lost or removed. If
power is off longer than this, the
Time and Date will need to be
reprogrammed into the system. All
other specific programming that has
been done will remain intact after
power has been restored.
DoorKing offers a 12 volt .8 amp
hour gel cell battery that can
connect to the main terminals 9 and
10 to provide back-up power during
power interruptions.
(DoorKing P/N 1801-008)
Over Voltage Power Note: LED located on
bottom left corner of board will light up if
too much power is applied to circuit board.
Wire Size Max Distance
18AWG
16 AWG
100 ft
200 ft
Power Transformer Wire Run Table
1.5 Grounding and Surge Suppression
Power Transformer Wires
(Not supplied)
Supplied Transformer
Polarity does
not matter.
Output
16.5 VAC
20 VA
CAUTION
DO NOT power the unit from a 24-Volt
source (Such as a gate operator).
Damage will occur to the unit that is
NOT covered under DoorKing’s warranty.
Proper Grounding and the use of surge suppressors can significantly reduce the chance of component failure because of static
charges or surges. To be effective, ground connections should be made with a minimum 12 AWG wire to a ground point within
10 feet of the device being protected. The ground point can be at an electrical panel, a metallic cold water pipe that runs in the
earth or a grounding rod driven at least 10 feet into the soil. A gooseneck mounting post anchored in concrete does NOT make
a good ground.
Telephone Line Surge Suppressor
It is highly recommended that telephone line surge
suppressor (DoorKing P/N 1877-010) be installed
to help protect the system from phone line power
surges. Surge suppressor must be positioned 3 ft
or less from the ground source, 12 AWG min.
Low Voltage Surge Suppressor
It is highly recommended that a low voltage surge
suppressor (DoorKing P/N 1878-010) be installed to
help protect the telephone entry system from power
surges. Surge suppressor must be positioned 3 ft or
less from the ground source, 12 AWG min.
Some Acceptable Ground Sources
Ground to metallic cold water pipe.
Ground
Wire
Ground
Wire
Phone Company
Transformer
Ground to existing electrical system.
Electrical
Panel
Grounding rod 10 feet in soil.
IMPORTANT: Ground wire shown without
safety protection for clarity. Make sure
ground wire is protected from being
touched or electrical shock could occur!
Surge suppressor within
3 ft of ground source.
PHONE LINE
1877-010
Surge suppressor
within 10 ft of unit.
Surge suppressor within
3 ft of ground source.
POWER LINE
1878-010
Surge suppressor
within 10 ft of unit.
OV

1838-066-E-12-16 9
Telephone
Wire Conduit
High Voltage
Power Wire
Conduit
Electrical field from power wires.
18” minimum
Underground Cutaway
Note: Do not run telephone wires and high voltage power
wires in the same conduit. Separate the high voltage
conduit and the telephone conduit by at least 18inches to
prevent any electrical field interference that could occur.
“Tip” and “Ring” Definition. Common terms in the telephone service industry referring to the two wires or sides of
an ordinary telephone line. Tip is the ground side (positive) and Ring is the battery (negative) side of a phone circuit. The
ground side is common with the central office of the telephone company (telco); the battery side carries -48volts of DC voltage
when in an “Idle” or “On Hook” state.
Phone Line Polarity. Tip and ring reversal is mostly immaterial, except for special circuits including DID (Direct Inward
Dialing) trunks, T-1 lines, and ground start lines where the field side (“terminal”) equipment (a company's PBX switch, for
example) can only function correctly with correct tip and ring polarity.
Wire Type. It is extremely important to use the correct type of wire in telephone applications. Since the Access Plus system
requires phone lines to be run outdoors or in an underground environment, we recommend that you use only wire that is
rated for direct underground burial. For example, use Cat5e Gel Filled (flooded) UV Resistant Direct Burial Cable run in
conduit for your Access Plus system phone line requirements. Do not use thinly insulated brown-jacketed telephone wire (the
type found in the walls of a structure) for outdoor or underground phone line wiring. Using improper wire can cause noise and
hum on the phone line. Be sure that phone wire pairs are twisted.
Wire Size and Distance. Phone lines can be run up to 3600 feet, provided that the proper wire size is used.
1.6 “OPTIONAL” Telephone Line Wire
Be sure to observe electrical safety when working with phone lines. Phone lines carry electricity and the ring voltage can deliver
a substantial jolt.
In most older residences and buildings, the phone cable contains four wires; green, red, black, yellow. The green and red are
twisted to make one pair and the black and yellow are twisted to make another pair (This allowed for the addition of a second
phone line since telephones use only two wires). Most phone lines installed in the U.S. in the second half of the 20th Century
have this type of wire. This type of wire is now obsolete. All new telephone projects are using Cat5 wire. If you have Cat5 wiring
in your residence, the conversion is simple:
The convention for Cat5 wire is as follows:
•Colored pairs match; e.g., WHITE/blue mark (Tip +) wire goes
with BLUE/white mark (Ring -) wire for one phone line, etc.
•The pairs are used in the order pictured: for the first line, you
use BLUE, for the second line you use ORANGE, etc.
•An easy way to remember this is that the colors run from the
sky to the earth. BLUE sky comes first; ORANGE sunset second;
GREEN grass third; BROWN earth last.
Cat5 Wire
Four Conductor
Wire
Tip (+)
1st Line
Wire
Conversion
2nd Line
3rd Line
4th Line
Green
Red
Black
Yellow
Blue Pair
Orange Pair
Green Pair
Brown Pair
Ring (-)
(+) Tip
(-) Ring
(+) Tip
(-) Ring
(+) Tip
(-) Ring
Older Residences
Modern Residences
Wire Size Max Distance
24 AWG
22 AWG
20 AWG
18AWG
800 ft
1600 ft
2200 ft
3600 ft
Telephone Wire Run Table

1838-066-E-12-16
10
J1
1
2
3
4
5
6
7
8
J4
The Access Plus system operates ONLY
on 16.5 VAC. DO NOT power the unit
with 24 Volt transformer or source
voltage. Use the supplied power
transformer, 16.5 VAC, 20 VA (or UL
listed equivalent) to power the
telephone entry system. DO NOT power
any other devices (electric strikes,
magnetic locks, additional units etc.)
from the unit’s power transformer.
See section 1.4 for wire size and run
distances.
1.7 Wire 1838 to “OPTIONAL” Telco Line
Use minimum 18
AWG wire for runs
up to 100 feet.
16 AWG wire for
runs up to 200 feet.
(Term. 11 and 13)
“Normally Open”
Vehicular
Gate Operator
INPUT
PHONE LINE
TIP RING
1877-010
OUTPUT
TIP RING GND GND
LOW VOLTAGE LINE
OUTOUT
1878-010
ININGNDGND
INPUT
OUTPUT
Telephone
Company
Demarcation
Point
Access Control Devices
1838 Circuit Board
Locate unit’s Phone Line
Inside Device
Cat5e
Cat5e
Recommended
1838
Access Plus
Phone at
APT #11
Phone at
APT #13
Tip
Ring
Tip
Ring
Tip
Ring
Pedestrian
Gate/Door
Maglock
Electric
Strike
WARNING
MOVINGGATECANCAUSE
Operategateonlywhengateareaisinsight
andfreeofpeopleandobstructions.
Donotallowchildrentoplayingatearea
oroperategate.
Donotstandingatepathorwalkthrough
pathwhilegateismoving.
Readowner’smanualandsafetyinstructions.
SERIOUSINJURYOR DEATH
CLASS
CERTIFIEDTO
CAN/CSAC22.2NO.247
CONFORMSTO
ANSI/UL-325
VEHICULARGATEOPERATOR
HP
53382
MODEL
SERIAL
VOLTSPHASE
AMPS60Hz
MAXGATELOAD
DoorKing,Inc.,Inglewood,CA
Be sure to properly
ground ALL boards.
See section 1.5 for
acceptable
grounding sources.
TIP (+): White/blue mark
RING (-): Blue/white mark
Magnetic locks or electric strikes must be
powered from a separate UL Listed power
transformer. DO NOT power strikes or magnetic
locks from the unit’s power transformer. Use
minimum 18AWG wire for runs up to 100 feet;
16 AWG wire for runs up to 200 feet. It is
recommended to keep power wire runs as short
as possible.
Optional Phone Line Surge Suppressor
DoorKing Surge Suppressor
P/N 1877-010 (or equivalent) is optional but
highly recommended.
For best protection, surge suppressor ground
wire MUST be 3-ft. or less in length. Use
minimum 12 AWG wire. Refer to instruction
sheet included with surge board and section
1.5 for complete information.
Optional Low Voltage Surge Suppressor
DoorKing Surge Suppressor P/N 1878-010 (or
equivalent) is optional but highly recommended.
For best protection, surge suppressor ground wire
MUST be 3-ft. or less in length. Use minimum 12 AWG
wire. Refer to instruction sheet included with surge
board for complete information.
Separate UL
Listed Power
Transformer
Connect to Incoming Telephone Company’s
Phone Line
Locate the telephone company demarcation device.
IMPORTANT Identify the telephone line that will connect to the Access Plus
unit and wire as shown.
Use only twisted pair telephone wire that is rated for direct underground
burial. DO NOT use wire that is intended for indoor applications.
Recommend Cat5e Gel Filled (flooded) UV Resistant Direct Burial Cable in
conduit. DO NOT run telephone wires and high voltage wires in the same
conduit. For complete info, see section 1.6.
Check Polarity of Telephone Line
Check for polarity on the phone “IN” wires, terminals 1 and
2. Terminal 2 must be positive with respect to terminal 1. Set
a VOM meter to measure DC volts. Place the positive lead on
terminal 2 and the negative lead on terminal 1. If the meter
shows a positive voltage - OK. If the meter shows a negative
voltage (needle moves off scale to the left), reverse the wires
on terminals 1 and 2.
Telephone Line
(Twisted Pair)
For complete info,
see section 1.6.
J
1
Main
Terminal
1970-010
Supplied Transformer
Polarity does not matter.
Output
16.5 VAC
20 VA
18
17
16 Com
15 N.C.
14 N.O.
13 Com
12 N.C.
11 N.O.
10
9
8
7
6
5
4
3 GND
2 TIP
1 RING
16.5
VAC
Central Office (C.O.)
Demarcation Device
Ground
12 AWG Min.
Within 3 ft
of Surge Board
Ground
12 AWG Min.
Phone In
(1-2)
Relay 1
(11-13) Note: Each relay can control a
normally open OR normally close
access control device. Relay
contacts are rated for 3 amps @
30 VAC maximum.
Relay 2
(14-16)
Power
(17-18)
Recommended
Recommended
“Normally Close” with Maglock
(Terminal 15 and 16)
“Normally Open” with Electric Strike
(Terminal 14 and 16)
Cat5e Without
Surge Board
Ground 12 AWG
Min. Within 3 ft
of Surge Board
OV
Telco
If the 1838will be programmed from your computer using a Phone modem or programmed and/or relay activation from a
remote touch-tone telephone, a dedicated telephone line MUST be connected to the 1838. Note: All 1838RJ-45 jack connec-
tions (direct or internet) to program the unit DO NOT use a “Telco” telephone line.

1838-066-E-12-16 11
J1 1
2
3
4
5
6
7
8
J4
1.8 Main Terminal Description
1.9 1838 Interface Board
1970-010
Relay 1
(Access Control Device)
Relay 2
(Access Control Device)
Optional Back-Up
Battery Power
Emergency
and/or Postal
Entry Switch
1. Phone In (Negative - Ring)
2. Phone In (Positive - Tip)
3. Ground (Required)
4. Not Used
5. Not Used
6. Not Used
7. Switch Input Relay 1. A switch closure across terminals 7 & 9
will activate relay 1 for its programmed strike time.
8. Switch Input Relay 2. A switch closure across terminals 8& 9
will activate relay 2 for its programmed strike time.
9. - 12 VDC Battery Negative. Also Common for terminals 7 & 8.
10. + 12 VDC Battery Positive.
11. Relay 1 Normally Open
12. Relay 1 Normally Closed
13. Relay 1 Common
14. Relay 2 Normally Open
15. Relay 2 Normally Closed
16. Relay 2 Common
17. 16.5 VAC Input Power
18. 16.5 VAC Input Power
The 1838interface board (1972-010) is piggybacked onto the main unit’s Plus circuit board (1970-010). The interface board
provides additional connections to the unit for keypads, card readers and/or RF receivers using RS-485 communication
protocol.
The 1838can be programmed via a PC using a network or modem connection. An RJ-45 jack (Cat5) is provided on the
interface board for network connections.
Use the RS-485 terminals to add up to six (6) card readers, keypads and/or RF receivers to the 1838. These devices must be
wired in a daisy-chain format with a maximum wire run distance of 4000 feet. We recommend that you use Cat5e wire for all
RS-485 wire runs.
DO NOT power RS-485 devices from the 1838. These devices must be supplied with their own power source. Refer to the
individual device wiring instructions for connection information and wiring guidelines for these products.
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
MIC VOL
KEYPAD
MASTER
CODE
J1
J3
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1.9.1 RS-485 8-Pin Connector Description
RS-485 DATA A (+)
RS-485 DATA B (-)
RS-485 Common
M
M
ON
MODEM / TCP ENB
1972-010
SW1
ON
SW2
TERMINATION
1
2
3
4
5
6
7
8
J1
RJ-45
Jack
(Cat5)
J4
LAN CONNECTION DATA TRANSMIT
BAD DNS LAN DOWN
RS-485 RX
PHONE LINE
IN USE
1970-010
WARNING
Maximum
input voltage to terminals
9 and 10 is 14.5 Volts DC.
BATT
CHARGE
BATT CHARGE LED: When
battery is connected to 9
and 10, Green LED will
light when charging and
turn OFF when charged.
Over Voltage Power Note:
OV LED will light up if too much
power is applied to circuit board.
OV
Input Power
(Transformer)
(Optional - Phone modem
programming or remote
touch-tone phone control only)
Terminals 4-8
are not used
with the 1838.
Phone In
(Twisted Pair)
Wireless
Adapter
OR
DO NOT use 24V.

1838-066-E-12-16
12
SPEAKER
VOL
MIC VOL
KEYPAD
MASTER
CODE
1970-010
1112345678910
J2
J1
J3
1970-010
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
MIC VOL
V
MI
MASTER
M
E
R
CODE
D
E
J1
J3
J3
J3
J
1970-01
0
12
11
1
0
9
8
7
6
5
4
3
2
1
ON
ON
MODEM / TCP ENB
1972-010
SW1
SW2
J1
RJ-45
Jack
(Cat5)
J4
LAN CONNECTION
TERMINATION
DATA TRANSMIT
BAD DNS
TERMINATION LAN DOWN
RS-485 RX
PHONE LINE
IN USE
ON
ON
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
SW1
ON
1
0
OFF
BOARD ADDRESS
1513-010
1098765
4
321
TERMINATION
8053-010
SW4 SW5SW2 SW3
ON
ON
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
BOARD ADDRESS
2354-010
SW1
SW4 SW2 SW3
ON
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
RS-485 Daisy Chain Wiring
RS-485
Keypad
RS-485
Cardreader
+
-
Com
Terminals 1 and 2
MUST be twisted.
Terminals 7 and 8
MUST be twisted.
Terminals 7 and 8 MUST be twisted.
Terminals 7 and 8
MUST be twisted.
Com
+
-
Com
+
-
Com
+
-
678 10954321
1
2
3
4
5
6
7
8
The wires connecting terminals 1 & 2 from
the 1838to terminals 7 & 8on the
DoorKing RS-485 boards MUST be
twisted. We recommend that you use
Cat5e cable for all the RS-485 connec-
tions (See section 1.6 for wire size and
run distances table). Use one twisted pair
to connect these terminals (terminal 1
connects to RS-485 terminal 8; terminal 2
connects to RS-485 terminal 7) and then
one wire from another twisted pair to
connect the common terminal (terminal 3
from the 1838to terminal 6 on the RS-485
board).
If wiring will be
outdoors or under-
ground, use Cat5e
Gel Filled (flooded)
UV Resistant Direct
Burial Cable.
Any RS-485 Keypad, Cardreader and
MicroPlus RF Receiver sequence
allowed. Maximum distance from end
to end is 4000 feet in a Daisy Chain
format as shown, see next page for
different RS-485 wiring configurations.
Do Not power RS-485 devices from the 1838.
RS-485 devices must be powered from their
own power source. Refer to the individual device
wiring instructions for connection information
and wiring guidelines for these products.
Cat5e
Cat5e
Cat5e
TERMINATION
RS-485 DATA A (+)
RS-485 DATA B (-)
RS-485 Common
67854321
RS-485
MicroPlus
RF Receiver
When 3 RS-485 wires are
connected to terminal, then
SW 5 termination switch
MUST be ON (End of chain).
2
354-010
When 6 RS-485 wires are
connected to terminal,
then SW1 termination
switch MUST be OFF.
13-010
3-
3-
When 6 RS-485 wires are
connected to terminal,
then SW1 termination
switch MUST be OFF.
J1
R
J
-4
5
J
ack
(C
at5
)
LAN CONNECTION
O
AN
T
C
E
DATA
ATA
When 3 RS-485 wires are
connected to terminal
(end of daisy chain), then
SW2 termination switch
MUST be ON.
When 6 RS-485 wires are
connected to terminal
(middle of daisy chain),
then SW2 termination
switch MUST be OFF.
OFF
8053-010
SW4S
W5
SW2 SW3
ON
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
ON
Device Address
Set to 003
Device Address
Set to 004 Device Address
Set to 005
10987654321
4
7
0
1
5
8
2
6
9
3

1838-066-E-12-16 13
ON
ON
RS-485 Configurations
RS-485 Device Addresses
Termination Switches
4000 ft Maximum (3/4 Mile)
CORRECT Configuration Samples
INCORRECT Configuration
4000 ft Maximum (3/4 Mile)
ONON
SW2
Terminated
End Device
Address
003
Term Sw
OFF
Address
003
Term Sw
ON
Terminated
End Device
Terminated
End Device
Terminated
End Device
Terminated
End Device
Address
004
Term Sw
OFF
Address
003
Term Sw
Term Sw
Term Sw
Term Sw
OFF
Address
004
Term Sw
OFF
Address
005
Term Sw
OFF
Address
006
Term Sw
OFF
Address
007
Term Sw
Terminated
End Device
ON
Address
008
Term Sw
ON
Terminated
End Device
Address
003
Term Sw
ON
Terminated
End Device
Address
004
Term Sw
OFF
Address
003
Term Sw
OFF
Address
006
Term Sw
OFF
Address
005
Term Sw
ON
Terminated
End Device
Address
004
Term Sw
ON
Terminated
End Device
Address
007
Term Sw
ON
Terminated
End Device
Address
008
Term Sw
OFF
Address
003
Term Sw
OFF
Address
004
Term Sw
OFF
Address
005
Term Sw
OFF
Address
006
Term Sw
Terminated
End Device
ON
Address
007
Term Sw
1
ON
Terminated
Device
Address
005
Term Sw
2 Devices “Daisy Chain”
OFF
Address
004
Term Sw
Address
008
Term Sw
OFF
Address
003
Term Sw
Address
003
Term Sw
Terminated
End Device
ON
Address
004
Term Sw
ON
Address
007
Term Sw
Internal Addresses
001 for Relay 1
002 for Relay 2
(Factory Set)
Maximum of two (2)
terminated end
devices allowed.
Maximum of six (6)
RS-485 devices allowed.
Any RS-485 Keypad,
Card Reader,
MicroPlus RF
Receiver and Access
Plus system “Daisy
Chain” wiring
sequence allowed.
Access Plus system on
end of “Daisy Chain”
wiring sequence has the
strongest signal strength.
The Access Plus system can be wired in the middle of the “Daisy Chain” if needed. It is
important that the distance restriction (4000 ft) be observed and that the devices at the end
of the chain have their termination switches ON. The devices in the middle of the chain have
their termination switches turned OFF.
Every RS-485 device (keypad, card reader, MicroPlus RF
receiver) must have a unique address assigned to it, starting
with 003. The address selector switches are located on the
RS-485 circuit board (see instruction sheets that come with
each RS-485 device). The address order of the devices
connected to the 1838does not matter. What is important is
that the addresses must be numbered in sequence. Do not
skip a number in the address sequence and start the
sequence with 003
(e.g. If three (3) RS-485 devices are daisy chain wired to the
1838and their addresses are 003, 004 and 006, this is wrong.
They must be addressed 003, 004 and 005).
The 2 internal relays on the 1838circuit board are 001 and
002. Valid RS-485 external device addresses for use with
the 1838 are 003, 004, 005, 006, 007 and 008.
Important Note: The device address is referred to as a
“Relay Number” in the programming software.
A termination switch is located on every circuit board. The
termination switch must be OFF for every device wired in
the middle of the daisy chain. The devices at each end of
the daisy chain must have their termination switches ON.
Some Configuration Problems to Avoid:
The total distance for the complete wire run is greater than
4000 ft.
There are more than 6 RS-485 devices.
There are more than 2 wire runs coming out of the 1838.
There are more than 2 end devices
terminated and/or incorrect end device
terminations (Not turned ON).
There are more than 6 addresses and/or
duplicate or skipped addresses.
An RS-485 device can not have 2 RS-485
devices separately continued from it.
The 1838must have it’s SW2 termination
switch turned OFF when 2 terminated end
devices are being used.
2
1
2
3
4
44
4
5
5 5
6
7
6
7
ON
ON
SW2
ON
SW2
Internal Addresses
001 for Relay 1
002 for Relay 2
(Factory Set)
OFF
SW2
FF
Term Sw
Internal Addresses
001 for Relay 1
002 for Relay 2
(Factory Set)
OFF
SW2
FF
Term Sw
Internal Addresses
001 for Relay 1
002 for Relay 2
(Factory Set)
OFF
SW2
FF
Term Sw
ON
SW2
Term Sw
3
“Daisy Chain”
End
“Daisy Chain”
End
“Daisy Chain”
End
“Daisy Chain”
Middle
“Daisy Chain”
Middle
“Daisy Chain”
Middle
Access Plus
Access Plus
Access Plus
Access Plus
Access Plus
Access Plus
ON
OFF
FF
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
1
0
00 3
BOARD ADDRESS
First Rotary Switch
Toggle
Switch
Second Rotary Switch
Setting Board Address

1838-066-E-12-16
14
Internet
1234
There are a number of ways to communicate with the 1838via a network connection. Before any programming can be
attempted, you need to install the Access Plus programming software on the computer you want to use for this purpose. The
computer must have a network card installed. Follow the instructions in the Access Plus programming software help guide and
refer to section 2.3 for setup information.
Using a network connection, you can connect to the 1838in different ways:
Locally with a direct connection from the computer to the 1838using a commercially available crossover cable.
1.9.2 Network Connections
Direct Connection Using a Crossover Cable
MODEM / TCP ENB
1972-010
SW1
1
2
3
4
5
6
7
8
BAD
DNS
LAN
DOWN
RS-485
RX
J4
ON
J1
RJ-45
Jack
(Cat5)
SW2
ON
SOFTWARE
INSTALLED
SOFTWARE
INSTALLED
Maximum distance on
Cat5 wire run is limited
to 325 feet (100 meters).
Maximum distance on Cat5 wire
run (Crossover cable) is limited
to 325 feet (100 meters).
Note: Router address is set to 192.168.001.001
(See 2.3.3 Set the gateway (router) IP address).
Note: 1838address is
set to 192.168.001.030
(See 2.3.1 Set the 1838
IP address).
Note: Notebook OR PC address is set to 192.168.001.107
(Notebook OR PC searches for 192.168.001.030 in LAN network).
RJ-45
RJ-45
RJ-45
RJ-45 Wired or Wireless Router
(Wireless shown)
RJ-45
Cable
(Cat5)
RJ-45
Cable
(Cat5)
Locally by connecting the computer to the 1838through a router. This is a Local Area Network (LAN) connection.
Direct Connection Using a Router (LAN)
MODEM / TCP ENB
1972-010
SW1
1
2
3
4
5
6
7
8
BAD
DNS
LAN
DOWN
RS-485
RX
J4
ON
J1
RJ-45
Jack
(Cat5)
SW1
ON
Cat5
Cat5 for LAN Connection
Wired to a PC
for LAN Connection
Wireless
When using a
Wireless Router
SOFTWARE
INSTALLED

1838-066-E-12-16 15
•Through the internet with a static IP address. This is a Wide Area Network (WAN) connection and will require a router
and a DSL or cable modem with an internet connection.
•Through the internet with a dynamic IP address. This is a Wide Area Network (WAN) connection and will require a
router and a DSL or cable modem with an internet connection. You will also need a registered DDNS host name.
SOFTWARE
INSTALLED
Through the Internet (WAN)
MODEM / TCP ENB
1972-010
SW1
1
2
3
4
5
6
7
8
BAD
DNS
LAN
DOWN
RS-485
RX
J4
ON
J1
RJ-45
Jack
(Cat5)
SOFTWARE
INSTALLED
PC with Internet Access
Laptop with Internet Access
(Wireless is optional)
Internet
Phone Company or
Cable Company Input
RJ-45
RJ-45
RJ-45
RJ-45
Cable
(Cat5)
Internet
1234
Cat5
Cat5 for LAN Connection
Cat5 for WAN Connection
Wired or Wireless Router
(Wireless shown)
Maximum distance on
Cat5 wire run is limited
to 325 feet (100 meters).
Router address: 192.168.001.001
Note: 1838address is set
to 192.168.001.030
(See 2.3.1 Set the unit’s IP
address).
Note: The gateway address must set into the
1838. This allows the unit to “register” with the
LAN 192.168.001.001
(See 2.3.3 Set the gateway (router) IP address).
SW2
ON
DSL Modem or
Cable Modem
The static IP address or the
DDNS host IP address is
needed for modem.

1838-066-E-12-16
16
The 1838has a dedicated phone line. A PC MUST be connected to a separate phone line to program the 1838.
1.9.3 Phone Modem Connection
Phone Cable
DEDICATED Phone Line
Phone Modem
Phone Modem Connection: 1838 and PC connected on DIFFERENT phone lines.
External
phone modem
connection to
the PC shown.
To Phone Company Telephone Lines
RJ-11
To Phone Company
Telephone Lines.
Telephone
Company
SOFTWARE
INSTALLED
To “Phone In”
Terminal
Table of contents
Other DKS IP Access Controllers manuals