XR150/550 LAB GUIDE
Instructor-Led Training
IDENTIFY PANEL COMPONENTS
1. Identify the following panel components using the
panels in front of you, or the on-screen photo of the
XR.
êReset header
êProgramming
header
êOutputs
êAC Power terminals
êCellular pins
ê1100 Series antenna
connection
êOn-board zone
terminals
êNetwork connection
êEXP header
POWER UP THE CONTROL PANEL
1. Connect AC power to terminals 1 & 2
êTransformer type: 16.5VAC 50VA
2. Connect battery backup to terminals 3 & 4
3. Connect alarm bell to terminals 5 & 6
êNormal 12VDC is supplied to terminal 5, terminal 6 is ground reference
ê1/2 W 1K Ohm resistor should be added across the bell circuit for supervision
ENTER PANEL PROGRAMMER
1. Reset the panel using the RESET JUMPER
2. Enter 6653 (PROG) and press CMD
3. Press CMD to navigate through the panel programmer
menus:
êInitialization
êCommunication
êNetwork Options
êMessaging Setup
êDevice Setup
êRemote Options
êSystem Reports
êSystem Options
êBell Options
êOutput Options
êOutput Information
êOutput Groups
êStatus List
êMenu Display
êPC Log Reports
êArea Information
êZone Information
êStop
êSet Lockout Code
êFeature Upgrade
ADJUST COMMUNICATION TYPE
1. Navigate to COMMUNICATION and press a top-row
select area
2. Press a top-row select area to clear the default
ACCOUNT NUMBER
3. Enter in an ACCOUNT NUMBER
4. Press CMD to navigate to PATH
5. Press 1to program PATH 1
6. Press a top-row select area to display the
COMMUNICATION types
7. Select NET
8. Press CMD to navigate to RECEIVER IP
9. Press a top-row select area and enter in the DMP Tech
Support receiver IP Address
ê209.248.148.051 (Port 2001)
10. Press CMD to exit COMMUNICATION
ADD A KEYPAD
1. Navigate to DEVICE SETUP and press a top-row
select area
2. Enter a DEVICE NUMBER and press CMD
êThe valid range for an XR150 panel is 1-8, XR550 is 1-16
3. Press a top-row select area and enter a DEVICE NAME
4. Press CMD to confirm the DEVICE TYPE
5. Press CMD to exit DEVICE SETUP
ADJUST THE KEYPAD ADDRESS
GRAPHIC TOUCHSCREEN KEYPAD
1. Select OPTIONS from the carousel
2. Select the INSTALLER OPTIONS icon
3. Enter 3577 (INST) and press CMD
4. Select KEYPAD OPTIONS (KPT OPT)
5. Press a top-row select area and enter a new
keypad address
6. Press CMD to exit Keypad Options
7. Select STOP to save keypad programming
THINLINE KEYPAD
1. Press and hold the BACK ARROW and CMD for 2
seconds
2. Enter 3577 (INST) and CMD
3. Select KEYPAD OPTIONS (KPD OPT)
4. Press a top-row select area or key to change the
keypad address
5. Press CMD to exit KEYPAD OPTIONS
6. Select STOP to save keypad programming
CONFIGURE SYSTEM OPTIONS
1. Navigate to SYSTEM OPTIONS and press a top-row
select area
2. Press CMD to navigate to ENTRY DELAY 1
3. Press a top-row select area and choose a time from
30 to 250 seconds
4. Repeat this process for ENTRY DELAY 2
5. Press CMD to navigate to HOURS FROM GMT
6. Press a top-row select area, enter in the hours from
GMT for your location and press CMD
7. Using CMD, navigate to HOUSE CODE
8. Press a top-row select area and enter a house code
from 1-50 and press CMD
9. Using CMD, navigate to ENTER WEATHER ZIP CODE
10. Press a top-row select area and enter a local ZIP code
to display weather alerts on the keypad
©2021 Digital Monitoring Products, Inc. | 21041 | LT-2351©2021 Digital Monitoring Products, Inc. | 21041 | LT-2351
ADD AN AREA
1. Navigate to AREA INFORMATION and press a top-
row select area
2. Enter an AREA NUMBER and press CMD
3. Press CMD until EXIT DELAY displays
4. Press a top row select key or area and enter a time
between 45 and 250 seconds
5. Press a top-row select area to clear any text and enter
in a new area name
6. Exit AREA INFORMATION and navigate to STOP to
save changes
ADD A WIRELESS ZONE
1. Navigate to ZONE INFORMATION and press a top-
row select area
2. Enter a ZONE NUMBER and press CMD
3. Press a top-row select area and enter a ZONE NAME
4. Press a top-row select area and select a ZONE TYPE
5. Press top-row select area to display the list of
available areas and select the appropriate area
6. At the NEXT ZONE? prompt, select NO to program a
wireless zone
7. At the WIRELESS? prompt, select YES and press CMD
8. Enter a SERIAL NUMBER and press CMD to navigate
to the NEXT ZONE? Prompt
ADD A WIRED ZONE
1. Add ZONE 1 as a hard-wired zone in the ZONE
INFORMATION menu
êEOL resistor value is defaulted to 1k, but you can change the value up to 2.2k for taking
over an existing panel in System Options.
STANDARD WALK TEST
1. At the keypad, enter 8144 (WALK) to enter the WALK
TEST menu
2. Select STD to begin the standard walk test
3. Trip wired and wireless zones to complete the
standard walk test
WIRELESS WALK TEST
1. At the keypad, enter 8144 (WALK)
2. Select WLS to begin the wireless check-in test
PIR WALK TEST
1. At the keypad, enter 8144 (WALK)
2. Select PIR to begin the PIR walk test
DIAGNOSTIC MENU
1. At the keypad, enter 2313 (DIAG) to enter the
DIAGNOSTIC MENU
2. Press CMD until the keypad displays COMM STATUS
and press a top row select area
3. Press 1to test COMMUNICATION PATH 1
4. When the signal strength is displayed, select YES to
continue the test
êCellular Communcation Only
5. Press CMD and select STOP to exit the DIAGNOSTIC
MENU
EDIT AREA NAMES
1. Press CMD to navigate to AREA INFORMATION
2. Press a top-row select area to enter AREA
INFORMATION
3. Enter an AREA NUMBER and press CMD
4. Press CMD until EXIT DELAY displays
5. Press a top row select key or area and enter a time
between 45 and 250 seconds
6. Press a top-row select area to clear any text and enter
in a new area name
7. Exit AREA INFORMATION and navigate to STOP to
save changes
8. Arm, disarm and trip an alarm in Area system type
ARM & DISARM
1. Arm the system, trip an alarm and disarm
CHANGE THE SYSTEM TYPE TO A/P
1. Enter the panel programmer by entering 6653
(PROG) at the keypad
2. Navigate to SYSTEM OPTIONS and press a top-row
select area
3. Press a top-row select area to display the list of
system types
4. Select A/P as the system type
5. Exit SYSTEM OPTIONS and navigate to STOP to save
changes
6. Arm, disarm and trip an alarm in A/P system type
CHANGE THE SYSTEM TYPE TO H/S/A
1. Enter the panel programmer by entering 6653
(PROG) at the keypad
2. Navigate to SYSTEM OPTIONS and press a top-row
select area
3. Press a top-row select area to display the list of
system types
4. Select H/S/A as the system type
5. Exit SYSTEM OPTIONS and navigate to STOP to save
changes
6. Arm, disarm and trip an alarm in H/S/A system type
XR150/550 LAB GUIDE
CREATE A SCHEDULE
1. At the keypad, press CMD until the USER MENU?
prompt displays
2. Select YES and enter 99+CMD to enter the USER
MENU
3. Using CMD, navigate to SCHEDULES? and press a
top-row select area
4. Select TIMES
5. To create a time schedule, select ADD
6. Press 1to create Schedule 1
7. Press a top row area to name the schedule ACCESS
8. Press CMD and select a day of the week.
9. Enter the BEGIN and END times for the chosen day
10. Set times for each day of the week
11. Create another schedule named LIGHTS
CREATE A PROFILE
1. At the keypad, press CMD until the USER MENU?
prompt displays
2. Select YES and enter 99+CMD to enter the USER
MENU
3. Using CMD, navigate to PROFILES? and press a top-
row select area
4. Select ADD and enter 11 to create Profile 11
5. Press a top row area to name the profile ACCESS
6. Assign ARM/DISARM AREA 2 and press CMD
7. Assign ACCESS AREA 2 and press CMD
8. Press CMD until DISARM? displays and select YES
9. Navigate to DOOR ACCESS and confirm it is set to
YES
10. Navigate to FIRST ACCESS SCHEDULE and press the
third select area to enter the schedule number for the
access schedule
11. LIST will show the schedule names
12. Press CMD until PROFILE 11 ADDED is displayed
13. Create another profile named MANAGEMENT using
Profile 12
êThe instructor will provide settings for this profile
ADD A USER CODE WITH PIN
14. Enter the USER MENU and navigate to the USER
CODES? prompt
15. Press a top-row select area to add a USER CODE
16. Select ADD
17. Select the USER NUMBER and press CMD
êThe fourth top row select area will display the lowest available user number
18. Enter in a 5-digit user code and press CMD
19. Press a top-row select area to add a USER NAME and
press CMD
20. Press a top row select area enter 12 to assign
PROFILE 12 to this user
êLIST will display the profile names
21. Press CMD until USER ADDED displays
ADD A USER CODE WITH CARD
1. Enter the USER MENU and go to USER CODES?
2. Press a top-row select area to add a USER CODE
3. Select ADD
4. Select the USER NUMBER and press CMD
5. Scan card by waving it over the blue status LED
6. Press a top-row select area and add a USER NAME
and press CMD
7. Press a top-row select area and enter 11 to assign
PROFILE 11 to this user.
8. Press CMD until USER ADDED displays
PROGRAM AN ANNUNCIATOR OUTPUT
1. Remove all power from the panel
2. Connect a 4-wire harness to the OUTPUTS header on
the panel
3. Connect the POSITIVE leg of the LED to the RED
terminal on the panel
4. Connect the other leg of the LED to OUTPUT 3 on the
panel
5. Power the panel back up
6. Enter the Programmer by entering 6653 (PROG) at
the keypad
7. Navigate to AREA INFORMATION and press a top-
row select area
8. Navigate to settings for AREA 1
9. Navigate to ARMED OUTPUT and press a select area
to clear the current setting
10. Set the output to 3
11. Navigate to STOP to save changes and exit the
Programmer
12. Arm AREA 1 to confirm the output is working
PROGRAM A RELAY
1. Remove all power from the panel
2. Plug a MODEL 305 relay into the socket for OUTPUT 1
êMake sure the relay is oriented correctly
3. Connect the MODEL 431 harness to the header
between the output sockets
XR150/550 LAB GUIDE
4. Connect the POSITIVE leg of the LED to the RED
terminal on the panel
5. Connect the other leg of the LED to the second
ORANGE wire on the harness
6. Connect the second GRAY wire to the BLACK terminal
on the panel
7. Power the panel back up
8. Enter the Programmer by entering 6653 (PROG) at
the keypad
9. Navigate to ZONE INFORMATION and press a top-
row select area
10. Navigate to settings for ZONE 1
11. Program ZONE 1 as a NIGHT type zone in AREA 1
12. At the NEXT ZN? prompt, select NO
13. Navigate to DISARMED SHORT and press CMD until
OUTPUT NO is displayed
14. Press a select area to set the output to 1.
15. Set the output action to FOLLOW
16. Navigate to STOP to save changes and exit the
Programmer
17. Press the button to trip ZONE 1.
êNotice the output state follows the zone state.
CREATE AN OUTPUT SCHEDULE
1. Enter the user menu and press CMD until
SCHEDULES? is displayed.
2. Press a select area, then select TIMES, then ADD.
3. Enter 1 for the schedule number, then name the
schedule LED.
4. Set begin and end times for each day of the week.
5. When all times are set, press the BACK ARROW until
SAVING SCHEDULES is displayed on the keypad.
6. Re-enter the schedule programming section. Press
CMD and select OUTPUT.
7. Enter output 1, then schedule 1.
8. Press the BACK ARROW to exit schedule
programming.
9. Advance panel time to test the begin and end times
for the schedule.
QUESTIONS
What else would you like to learn about the XR series?
NOTES:
XR150/550 LAB GUIDE

Other manuals for XR150 series

6

This manual suits for next models

1

Other DMP Electronics Control Panel manuals

DMP Electronics XR200 Operating instructions

DMP Electronics

DMP Electronics XR200 Operating instructions

DMP Electronics XT30INT User manual

DMP Electronics

DMP Electronics XT30INT User manual

DMP Electronics XR20ATM User manual

DMP Electronics

DMP Electronics XR20ATM User manual

DMP Electronics XR2400F User manual

DMP Electronics

DMP Electronics XR2400F User manual

DMP Electronics XR100 User manual

DMP Electronics

DMP Electronics XR100 User manual

DMP Electronics XR6 COMMAND PROCESSOR User manual

DMP Electronics

DMP Electronics XR6 COMMAND PROCESSOR User manual

DMP Electronics XT Series User manual

DMP Electronics

DMP Electronics XT Series User manual

DMP Electronics XTLtouch User manual

DMP Electronics

DMP Electronics XTLtouch User manual

DMP Electronics XT30 Series User manual

DMP Electronics

DMP Electronics XT30 Series User manual

DMP Electronics XT Series Operating instructions

DMP Electronics

DMP Electronics XT Series Operating instructions

DMP Electronics XT50 Series User manual

DMP Electronics

DMP Electronics XT50 Series User manual

DMP Electronics XRSuper6 User manual

DMP Electronics

DMP Electronics XRSuper6 User manual

DMP Electronics XR5FC Operating instructions

DMP Electronics

DMP Electronics XR5FC Operating instructions

DMP Electronics XR550 series User manual

DMP Electronics

DMP Electronics XR550 series User manual

DMP Electronics XR150CAN Series User manual

DMP Electronics

DMP Electronics XR150CAN Series User manual

DMP Electronics XR550INT Series User manual

DMP Electronics

DMP Electronics XR550INT Series User manual

DMP Electronics XT Series Datasheet

DMP Electronics

DMP Electronics XT Series Datasheet

DMP Electronics XR500N SERIES User manual

DMP Electronics

DMP Electronics XR500N SERIES User manual

DMP Electronics XT Lite User manual

DMP Electronics

DMP Electronics XT Lite User manual

DMP Electronics XTLN User manual

DMP Electronics

DMP Electronics XTLN User manual

DMP Electronics PC0128 User manual

DMP Electronics

DMP Electronics PC0128 User manual

DMP Electronics XTLplus User manual

DMP Electronics

DMP Electronics XTLplus User manual

DMP Electronics XT Series Operating instructions

DMP Electronics

DMP Electronics XT Series Operating instructions

DMP Electronics Addressable Fire Alarm Control Panel XR2500F User manual

DMP Electronics

DMP Electronics Addressable Fire Alarm Control Panel XR2500F User manual

Popular Control Panel manuals by other brands

Teknim VAP404 Installation & operation manuals

Teknim

Teknim VAP404 Installation & operation manuals

Scame S81-HS Installation and user manual

Scame

Scame S81-HS Installation and user manual

EUROSEC CP8 installation instructions

EUROSEC

EUROSEC CP8 installation instructions

SALUPO INVERTER PLUS 3 Instruction and installation manual

SALUPO

SALUPO INVERTER PLUS 3 Instruction and installation manual

CAME ZL19N installation manual

CAME

CAME ZL19N installation manual

Bosch DS6R2 Installation and operation guide

Bosch

Bosch DS6R2 Installation and operation guide

Smarteh LMP-1.MP1B user manual

Smarteh

Smarteh LMP-1.MP1B user manual

Ross Touch Drive Guide

Ross

Ross Touch Drive Guide

Honeywell MINI-ZONE 69-1361 Schematic diagram

Honeywell

Honeywell MINI-ZONE 69-1361 Schematic diagram

Midea KJRM-120H2/BMWKO-E owner's manual

Midea

Midea KJRM-120H2/BMWKO-E owner's manual

Becker SWS52 manual

Becker

Becker SWS52 manual

Panduit ATLONA AT-VSP-800-BL installation guide

Panduit

Panduit ATLONA AT-VSP-800-BL installation guide

Frick Quantum ACUair Service manual

Frick

Frick Quantum ACUair Service manual

rako RCM100 Installation, Programming and Operating Instructions

rako

rako RCM100 Installation, Programming and Operating Instructions

fisair CCE2.0 Installation and operation manual

fisair

fisair CCE2.0 Installation and operation manual

RIB K 2007 CRX manual

RIB

RIB K 2007 CRX manual

CityGrow Systems CG800H-SKY Series user manual

CityGrow Systems

CityGrow Systems CG800H-SKY Series user manual

Azbil Infilex AC Series Specifications & instructions

Azbil

Azbil Infilex AC Series Specifications & instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.