Domestia DMC-012-003 S User manual

Manual
DMC-012-003 S
www.domestia.be

2
Table of contents
Table of contents ................................................................................................................ 2
1DESCRIPTION ................................................................................................................ 2
2CONNECTION .............................................................................................................. 3
2.1 Basic Wiring......................................................................................................................................3
2.2 Chaining the modules ..................................................................................................................4
3Addressing of the module .......................................................................................... 5
3.1 Automatical addressing from the application Domestia Home Manager (via the
master module).........................................................................................................................................5
3.2 Half-automatical addressing from the application Domestia Home Manager (via
the master module) .................................................................................................................................5
3.3 Manual addressing........................................................................................................................5
3.4 Reset to factory settings...............................................................................................................5
4TECHNICAL CHARACTERISTICS.................................................................................... 6
5WARRANTIES................................................................................................................. 6
1DESCRIPTION
The module DMC-012-003S is equipped with12 bipolar relay outputs and it can work as a slave module. A
master module is necessary to make it work.
Its relays can be used for lighting as for shutters/stores.
Its programming is done from the master module (for example DMC-012-003, DMC-008-001, DME-LAN-002)
DMC-012-003
AP www.domestia.be
CLI
RS485
AGND
B
Each contact 8A/250VAC
LN
100-240Vac 50/60Hz
BP
Adres
OUT7 OUT8OUT6OUT5OUT4OUT3OUT2OUT1 OUT9 OUT10 OUT11 OUT12
IN7 IN8IN6IN5IN4IN3IN2IN1 IN9 IN10 IN11 IN12
BACK ENTER
BUS
DMI
Each contact 8A/250VAC
4
31 2
2
3
1
6
54
8
9
DMC-012-003S
www.domestia.be
RS485
AGND
B
Each contact 10A/250VAC
LN
100-240Vac 50/60Hz
BP
Adres
OUT7 OUT8OUT6OUT5OUT4OUT3OUT2OUT1 OUT9 OUT10 OUT11 OUT12
IN7 IN8IN6IN5IN4IN3IN2IN1 IN9 IN10 IN11 IN12
Each contact 10A/250VAC
LED4
LED3
Legend :
(1) Module power
(2) Input of the bipolar potential-free contacts (usually connected to circuit breakers)
(3) Outputs of the potential-free contacts (generally for the connection to lights, stores …)
(4) Do not connect anything
(5) RS485 bus for connection to other modules : blue LED = communication between the modules
(6) Addressing-button/configuration –blue LED = internet connection –network traffic

3
2CONNECTION
The module DMC-012-003S is designed to operate as a slave module with one of these master modules :
-A module with 12-output relays (DMC-012-003)
-A module with 8-output relays (DMC-008-001)
-A management unit control module (DME-LAN-002 or DME-LAN-001)
The DMI bus loop (identification modules for pushbuttons) must only be connected to the master module.
The modules must be connected together using 3 wires : Bus RS485 (A, B et GND).
The GND wire of the RS485 bus cannot be connected to ground.
NB : It is possible to move modules to several switchboards (for example : one module in the basement and
another in the attic) by interconnecting the RS485 bus between the different switchboards. The identifcation
modules must always return to the master module.
2.1 Basic Wiring
NL
RS485 to master
module
A B GND
NLNL
DMC-012-003S
www.domestia.be
RS485
AGND
B
Each contact 10A/250VAC
LN
100-240Vac 50/60Hz
BP
Adres
OUT7 OUT8OUT6OUT5OUT4OUT3OUT2OUT1 OUT9 OUT10 OUT11 OUT12
IN7 IN8IN6IN5IN4IN3IN2IN1 IN9 IN10 IN11 IN12
Each contact 10A/250VAC
LED4
LED3

4
2.2 Chaining the modules
An example of chained modules :
BUS
DMI
DMC-012-003
AP www.domestia.be
CLI
RS485
AGND
B
Each contact 10A/250VAC
LN
100-240Vac 50/60Hz
BP
Adres
OUT7 OUT8OUT6OUT5OUT4OUT3OUT2OUT1 OUT9 OUT10 OUT11 OUT12
IN7 IN8IN6IN5IN4IN3IN2IN1 IN9 IN10 IN11 IN12
BACK ENTER
BUS
DMI
Each contact 10A/250VAC
4
31 2
DMC-012-003S
www.domestia.be
RS485
AGND
B
Each contact 10A/250VAC
LN
100-240Vac 50/60Hz
BP
Adres
OUT7 OUT8OUT6OUT5OUT4OUT3OUT2OUT1 OUT9 OUT10 OUT11 OUT12
IN7 IN8IN6IN5IN4IN3IN2IN1 IN9 IN10 IN11 IN12
Each contact 10A/250VAC
LED4
LED3
Input: 100-240V~ 50/60 Hz
2,6W ta -10°c to +40°c
LN
T1 T2 T3 T4
charge setting
1 2 3 4
ON DIP
IN1
IN2
IN3
IN4
ALL OFF
ALL ON
Standalone Inputs
OUT1
150W OUT2
150W
OUT3
150W OUT4
150W RS485
AGND
B
BP
Settings BP
Adres
DML-004-003
www.domestia.be
Made in Belgium
Disclaimer: Domestia assumes no responsibility and
will not accept any liability for damage that may affect
your product following the use of loads that are not in
accordance with the use of the product. Please refer
to the instructions in the manual for more information
or go to www.domestia.be

5
3Addressing of the module
By default the module has no address. The module needs to be addressed
sothat it can work.
3.1 Automatical addressing from the application
Domestia Home Manager (via the master module)
When the module is connected to a master module of the type DMC-008-001
(from firmware V1.28), DMC-012-003 or DME-LAN-002 (from firmware V3.0) the
module DMC-012-003S can be addressed from the programming application
« Domestia Home Manager ». The programming Software scans the bus RS485
to detect the connected modules. It is then possible to choose the module’s
address directly from this application. Refer to the installation and user manual
of these modules for more informations.
3.2 Half-automatical addressing from the application
Domestia Home Manager (via the master module)
When the module is connected to a master module of the type DMC-008-
001 (from firmware V1.28 or superior), DMC-012-003 or DME-LAN-002 (from
firmware V3.0. or superior) the module DMC-012-003S can be addressed by
simply pressing once the addressing button.
Refer to the installation and user manual of these modules for more
informations.
3.3 Manual addressing
To make the DMC-012-003 compatible with the older master modules (DMC-
012-002, DME-LAN-001) the module can be addressed via the addressing
button (By default the module has no address).
1) Press during 4 seconds on the addressing button (till the blue LED
goes off)
2) Then press as many times as the wished address requires (see
addressing table). The LED indicator lights up at each press. (max.
delay of 2 seconds between the successive pushes)
3) After a delay of 2 seconds following the last press the blue LED flashes
the number of times that the button has been pushed to confirm the
address.
3.4 Reset to factory settings
To reset the module to factory settings press the addressing button during a
time between 10 and 14 seconds. When the button is released the LED
flashes 10 times after a delay of 3 seconds to confirm the action.
Note : during the press on that button the LED lights up during 4 seconds then
goes off and lights up every two seconds as long as the button is pressed.
Addressing table
Module’s
address
Output
range
1
1-12
2
5-16
3
9-20
4
13-24
5
17-28
6
21-32
7
25-36
8
29-40
9
33-44
10
37-48
11
41-52
12
45-56
13
49-60
14
53-64
15
57-69
16
61-72
17
65-76
18
69-80
19
73-84
20
77-88
21
81-92
22
85-96
23
89-100
24
93-104
25
97-108
26
101-112
27
105-116
28
109-120
29
113-124
30
117-128
31
121-132
32
125-136
33
129-140
34
133-144
35
137-148
36
141-152
37
145-156
38
149-160
39
153-164
40
157-168
41
161-172
42
165-176
43
169-180
44
173-184
45
177-188
46
181-192

6
4TECHNICAL CHARACTERISTICS
Electrical characteristics :
•Dimensions : Width 213mm (12 modules DIN)
Height 60mm
•Voltage : 100-240V ~50/60Hz (internal fuse 1A)
•Input/Output terminals :
oSection of single stranded conductors: 6mm²
oMulti-strand conductor - Cross-section : 4mm².
•Bipolar relays 10A/250V~ :
oMaximum AC breaking capacity : 2500 VA resistive load
oMaximum AC load : 750 VA inductive load
oSingle-phase motor 230V~ : max 370W
oMaximum boot current : 120A max 5ms
The sum of the currents flowing through the 12 relays must not exceed 40A
•Insulation level : Double insulation according to the IEC/EN60601-1
•CE marking : This product complies with all applicable directives. The EU Declaration of Conformity is
available on www.domestia.be
Operating temperature :
•Storage : -30°C à + 65°C
•Operation : -10°C à +40°C
5WARRANTIES
Warranty conditions :
The duration of your product’s basic warranty is 2 years from the purchase date, which must be confirmed
with an invoice bearing the name of the seller and the date on which the sale took place and the serial
number(s) of your product(s) clearly indicated on the invoice .
In addition, so that the warranty is valid and can be used, the professional installation and commissioning of
the device must be carried out exclusively by a qualified person who, in the cases set out, must provide the
owner of the installation with an installation compliance statement.
Excluded from this warranty are all malfunctions and/or damage to the device due to the following causes:
• All defective parts due to negligent use, incorrect maintenance, installation that does not comply with that
specified by the manufacturer (always refer to the installation and user manual provided with the device)
• Damage caused by transport and/or handling
• Additional damage caused by incorrect interventions by the user trying to repair the initial fault
• Damage caused by inappropriate use, improper use, poor maintenance or failure to respect the instructions
given by the manufacturer in this user manual
• Damage due to electrical installation faults
• Repair attempts made by the customer or a third party which are not permitted
• Damage caused by accident, force majeure or other causes for which Domestia cannot be held
responsible
• Fault not affecting the proper functioning or proper use of the equipment.
Domestia
176, rue Jean-Jaurès
4430 Ans
Tél : 04/ 372 07 16
Fax : 04/ 372 07 19

7
System chart
Output’s name
Toggle
Impulse
Timer
Dimmer
Shutter
control
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

8
Output’s name
Toggle
Impulse
Timer
Dimmer
Shutter
control
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48