1 Preface
This installation guide describes how to install a PSS 5000 system. It is
assumed that the system is already configured correctly. If not, please refer to
the appropriate documentation.
2 Conditions
Temperature range (MID, 2004/22/EC:2004) operation -10 - +50
o
C
Storage temperature -20 - +80
o
C
Ambient humidity, H1 (OIML D11:2004) max. 90% RH, non-condensing
Mains power voltage max. 230VAC +10% = 253VAC
min. 230VAC -15% = 195VAC
Electromagnetic Environment Class (OIML D11:2004) E1
(residential, commercial and light industrial building)
Mechanical Environment (MID, 2004/22/EC) M1
(locations with vibration and shocks of low significance)
It is recommended that power is supplied from the same mains phase as:
the POS (Point Of Sale) and BOS (Back Office System) equipment,
the connected pump electronic, CC/BNT terminals, tank level gauge,
price signs etc.
Mains power is switched off by removing the mains cable plug from the inlet.
The mains cable must be installed according to local regulations. See section
5.1 for further information.
All external units, such as POS/BOS or pumps, must be connected using
shielded cables. The cables should be twisted pair with plaited shield with min.
80% cover. It is very important that the cable shield is connected properly in
both ends of the cable. See Fig. 4 for shield connection instructions.
Only Doms HIM (Hardware Interface Modules) may be installed in the PSS
5000 cabinet.
3 Technical data
Dimensions (H x W x D) 600 x 200 x 124mm
Weight approx. 8kg
Supply voltage, nominal 230VAC
Max. power consumption 43W
Fuse, 5 x 20mm, slow blow T400mA
Degree of protection IP 30