DoorKing 1603-210 User manual

Support
Post
Bracket
Bracket
Cover
U-Bolt
Clamp
U-Bolt
Clamp
Route wire
through
conduit.
Support Post Assembly
Use existing
circuit board
bracket bolts
to mount
support post
bracket.
Drill 7/8” hole
centered where
elbow touches
operator housing
(Approximately 18” down
from the top of operator).
Secure 3/4” conduit nipple
in drilled hole with
conduit nut .
2” conduit nut to secure elbow.
Use 2” conduit
nuts to secure
traffic light
assembly to
support post.
Route wire through
support post.
Traffic Light
Assembly
2” Elbow
Shut off AC power to operator.
Turn off DC power switch on certain models.
This kit is designed for the 1600 model barrier gate operators. Recommended for the 1603 auto spike system. The traffic signal is
synchronized with the gate operator’s up/down cycle. The red light stays on and only changes to green when the operator’s arm is
fully raised.
2” Threaded Elbow
2” Conduit Nut (3)
5/8” Cover Bracket
bolt and lockwasher
(2 sets)
3/4” Conduit Nipple
and Conduit Nut
U-Bolt Clamp with
lockwashers and nuts
(2 sets)
KitIncludes:
Plastic Traffic Light Assembly (Factory wired)
2” Threaded Support Post
Support Post Bracket
Bracket Cover.
Hardware:
TRAFFICLIGHTANDMOUNTINGKIT
Installation
DoorKing Part Number
1603-210
120 Glasgow Avenue
Inglewood, California 90301 U.S.A.
AssembleSupportPost MountSupportPostAssemblytoOperator
Support Post
1 2
www.leedan.com [email protected] Toll-Free: 800-231-1414
REVERSE
SENSITIVITY
TIME
DELAY
SW 1
SW 2
POWER
1
ON
2 3 4 5 6 7 81
ON
2 3 4 5 6 7 8
NC NO
NONCC
UP
LOOP
DOWN
LOOP
1234567891011121314
1601
Chassis Ground
ON
OFF
AC POWER DC POWER
ON
AUTO
DOWN
UP
OFF
NEU HOT
Red Wire (Com)
Brown Wire (N.O.)
Note: To reverse
light sequence
change to N.C.
(Ground) Green Wire
(Neutral) White Wire
(Hot) Black Wire
3/4” Conduit nipple
installed in operator housing.
Circuit Board
Bracket Bolt
Circuit Board
Bracket Bolt
115VAC
DANGER
HIGH VOLTAGE!
Chassis Ground
230/460VAC
115 VAC Hot
Neutral
Neutral
12345
(Ground) Green
(Neutral) White
(Hot) Black
Red and Brown
wire are the
same as the
115 VAC
installation.
Keep wire clear of all moving parts.
Note: This light has been designed to wire to operators that use 115 volt power
and a FORM C dry relay contact that activates when the operator is fully open.
1603-265-B-6-08
DoorKing Part Number
1603-210
Copyright 2008 DoorKing, Inc. All rights reserved.
120 Glasgow Avenue
Inglewood, California 90301 U.S.A.
WireTrafficLighttoOperator
Circuit Board Bracket
3
www.leedan.com [email protected] Toll-Free: 800-231-1414

Other DoorKing Control System manuals

DoorKing 1620 Series User manual

DoorKing

DoorKing 1620 Series User manual

DoorKing 2112 Operating instructions

DoorKing

DoorKing 2112 Operating instructions

DoorKing 1610 User manual

DoorKing

DoorKing 1610 User manual

DoorKing 1625 User manual

DoorKing

DoorKing 1625 User manual

DoorKing 1602-162 User manual

DoorKing

DoorKing 1602-162 User manual

DoorKing 80 Series Operating instructions

DoorKing

DoorKing 80 Series Operating instructions

DoorKing 1601-083 User manual

DoorKing

DoorKing 1601-083 User manual

DoorKing 1802 User manual

DoorKing

DoorKing 1802 User manual

Popular Control System manuals by other brands

U-Prox HUB LTE user manual

U-Prox

U-Prox HUB LTE user manual

Idex Knight DoseTech DMS instruction manual

Idex

Idex Knight DoseTech DMS instruction manual

Nibe SMO 10 Installation and maintenance instructions

Nibe

Nibe SMO 10 Installation and maintenance instructions

Schwing VECTOR Service manual

Schwing

Schwing VECTOR Service manual

Intellitec Generator Logic Control operating guide

Intellitec

Intellitec Generator Logic Control operating guide

NEC ElectraElite 48 System hardware manual

NEC

NEC ElectraElite 48 System hardware manual

DriSteem VAPOR-LOGIC 3 Installation and operation manual

DriSteem

DriSteem VAPOR-LOGIC 3 Installation and operation manual

Kenwood C-V500 instruction manual

Kenwood

Kenwood C-V500 instruction manual

Polyaire Zonemaster Unipoint RF Owner’s Manual & Setup Guide

Polyaire

Polyaire Zonemaster Unipoint RF Owner’s Manual & Setup Guide

CAME CAT Series quick start guide

CAME

CAME CAT Series quick start guide

That Little Box GpiO BOX USB manual

That Little Box

That Little Box GpiO BOX USB manual

Fröling SPS 4000 Service manual

Fröling

Fröling SPS 4000 Service manual

E-T-A SCS1000 Operation manual

E-T-A

E-T-A SCS1000 Operation manual

GasTech GTA-VSD20i Operator's manual

GasTech

GasTech GTA-VSD20i Operator's manual

Axis P1445-LE-3 user manual

Axis

Axis P1445-LE-3 user manual

ABL eM4 Twin installation manual

ABL

ABL eM4 Twin installation manual

Aprilaire 6000 Series Safety & installation instructions

Aprilaire

Aprilaire 6000 Series Safety & installation instructions

Mi-Light fullwat LENNY-MD-092 owner's manual

Mi-Light

Mi-Light fullwat LENNY-MD-092 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.