Doughboy PowerLine XP III User manual

365-2074
PowerLine XP III
Swimming Pool Pump (Black color model)
UL Models w/GFCI
0-3496-200 (1 HP), 0-3497-200 (1-1/2 HP)
NEC Models
0-3496-206 (1 HP), 0-3497-206 (1-1/2 HP)
Owner's Guide

2
PREPARATION
IMPORTANT SAFETY INSTRUCTIONS
FOR ALL MODELS:
When installing and using this electrical equipment,
basic safety precautions should always be fol-
lowed, including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. WARNING: To reduce the risk of injury, do not
permit children to use this product unless they are
closely supervised at all times.
3. WARNING: Risk of electric shock. Connect only to
a grounding type receptacle protected by a Ground
Fault Interrupter (GFCI).
(For storable pool pumps) This product is provided
with a ground-fault circuit-interrupter. If replacement
of the plug or cord is needed, use only identical
replacement parts.
(For all permanently installed units) Connect only to
a branch circuit protected by a ground-fault circuit-
interrupter (GFCI).
Contact a qualified electrician if you cannot verify that
the receptacle is protected by a GFCI.
4. Do not bury cord. Locate cord to minimize abuse
from lawn mowers, hedge trimmers, and other equip-
ment.
5. WARNING: To reduce the risk of electric shock,
replace damaged cord immediately.
6. WARNING: To reduce the risk of electric shock, do
not use an extension cord to connect unit to the
electrical supply; provide a properly located outlet.
FOR UL MODELS: (25 Ft. cord)
7. CAUTION: This pump is for use with storable pools
only. Do not use with permanently installed pools. A
storable pool is constructed so it may be readily disas-
sembled for storage and reassembled to its original
integrity. A permanently installed pool is constructed in
or on the ground or in a building such that it cannot be
readily disassembled for storage.
(For storable pools) The unit is provided with a
ground-fault circuit-interrupter (GFCI). To test the
GFCI, push the test button. The GFCI should
interrupt power. Push the reset button. Power should
be restored. If the GFCI fails to operate in this
manner, the GFCI is defective. If the GFCI interrupts
power to the pump without the test button being
pushed, a ground current is flowing, indicating the
possibility of an electric shock. Do not use the pump.
Disconnect the pump and have the problem
corrected by a qualified service represenative before
using.
FOR NEC/UL MODELS ONLY: (3 Ft. cord)
8. CAUTION: This pump is for use with permanently
installed pools and may also be used with hot tubs and
spas if so marked. Do not use with storable pools. A
permanently installed pool is constructed in or on the
ground or in a building such that it cannot be readily
disassembled for storage. A storable pool is con-
structed so that it may be readily disassembled for
storage and reassembled to its original integrity.
FOR ALL MODELS:
9. SAVE THESE INSTRUCTIONS.
ELECTRICAL SOURCE
FOR UL MODELS: (25 Ft. cord)
Your pump is supplied with a 25 foot, 3-wire electrical
cord and a 3-pronged plug. The pump is double insu-
lated and grounded. The pump electrical cord must be
connected to a grounded, 3-wire, 115 VAC electrical
receptacle.
The pump should be connected to a receptalce on a
dedicated circuit protected by a 20 AMP circuit breaker.
DO NOT use a grounding adaptor.
The receptacle must be protected by a Ground Fault
Circuit Interrupter (GFCI) in accordance with Article 680-
31 of the National Electrical Code (NEC), (Section 68-
204 of the Canadian Electrical Code (CSA) and local
codes or ordinances. For runs greater than 25 feet,
consult your local licensed electrical contractor.
FOR NEC/UL MODELS ONLY: (25 Ft. cord)
Your pump is suppplied with a 3-foot, 3-wire electrical
cord and a 3-prong flanged, twist-lock plug.
The pump electrical cord must be connected to a single
twist lock, grounding type receptalcle that is located a
minimum of 6 feet from the inside pool wall.
A qualified electrical contractor must install this recep-
tacle in accordance with Article 680-6 of the National
Electrical Code (NEC). A Ground Fault Interrupter
(GFCI) must be used. An ON/OFF Switch must be
installed at the receptacle.
Use a Hubbell No. 2310 Receptacle, 20 AMP 125 Volt
A.C. or an equivalent receptalcle that meets NEMA
Configuration L5-20R.
This pump is double insulated and grounded. Dead
metal parts are not in contact with pool water.
CAUTION
1.
DO NOT install the pump on a deck, it could fall into the
water, causing severe electrical shock. Do not install on
any surface at, above, or slightly below the top rail of the
pool.
2. DO NOT allow children or adults to climb, sit, or stand on
the pump unit. They could easily fall. Position the filter
and pump approximately 6 feet from the pool wall so they
may not be used as steps by children.
3. Always keep the water level in your pool between the water
level markers on the skimmer face plate. If the pump is run
with water level too low, the pump seal may overheat and
cause permanent damage to the pump.
4. Your Powerline pump must sit in it's pump base, on
a patio block, or on any firm surface that slightly
elevates the pump off the ground. This keeps water
away from the motor and prevents the vents of the
Power Pak from becoming blocked, which could
cause the motor to overheat.
SUCTION AND DISCHARGE CONNECTIONS
Your Powerline pump is provided with two union socket
connections for hard plumbing to 1-1/2" PVC pipe or flex
pipe and two union hose adaptors for connecting to 1-1/2"
inside diameter hose. Install o-ring into groove on end of
the body outlets, then position either the union socket or
hose adaptor and secure in place with the union nut.

3
Rotate valve knob counter-clockwise until it stops (open
position) for normal pumping operation.
Rotate valve knob clockwise until it stops (closed
position) when cleaning out the strainer basket or
servicing the pump.
MAINTENANCE
Make sure the pump is disconnected from the
electrical source before attempting any maintenance
work.
LUBRICATION
Periodically lubricate the O-Ring under the strainer
cover with a NON-PETROLEUM lubricant recom-
mended for A.B.S. and Lexan plastics. Consult your
pool dealer for lubricant selections.
If you have any questions or require assistance, contact
your Doughboy pool dealer.
CAUTION
Fingers can become wedged where Strainer Lid and
Union Fitting intersect. Please use caution when
removing the Strainer Lid.
SERVICING SAFETY TIPS
A. ALWAYS TURN “OFF” the main power switch and
the Ground Fault Circuit Interrupter (GFCI) breaker
switch so power is completely off before servicing
your unit.
B. ALWAYS BE SURE THE GROUND UNDER YOUR
FEET AND YOUR BODY IS DRY before you touch
electrical equipment. Failure to heed this warning
may cause personal injury due to severe electrical
shock.
C. ALWAYS have a qualified electrician service your
system if electrical problems occur. This system is
UL listed and must be serviced by a qualified electri-
cian to insure that the electrical integrity is main-
tained. Failure to do so may cause personal injury
due to severe electrical shock and may void the
listing and warranty.
D. ALWAYS have a qualified electrician install a
Ground Fault Circuit Interrupter (GFCI) breaker at
the electrical service or supply panel. Follow GFCI
manufacturer’s operating instructions for testing.
Failure to do so may cause personal injury due to
severe electrical shock.
CAUTION: To reduce the risk of electrical shock,
connect only to grounding type receptacles. A
Ground Fault Circuit Interrupter (GFCI) must be
provided in accordance with local codes or
ordinances.
CAUTION: To reduce the risk of electrical shock,
use only Original Equipment Manufactured (OEM)
replacement parts when servicing.
NOTE: Use ABS to PVC solvent cement when using the
union socket connections for hard plumbing installa-
tions. Refer to the solvent manufacturer's instructions for
preparations of socket and pipe end and solvent welding
of the joints.
SHUT-OFF VALVE
Your Powerline pump features a shut-off valve in the
pump suction inlet. This feature allows you to shut off
the flow from the skimmer when removing strainer
basket for cleaning or servicing the pump.

ITEM P/N QTY DESCRIPTION ITEM P/N QTY DESCRIPTION
1 1121-2038 1 Strainer Housing w/Suction Tube
2 1121-1980 1 Pump Base
3 340-1988 1 Strainer Basket
4 340-2590 1 Motor Housing
5 — 1 Elbow Suction Tube
(Part of 1121-2038)
6 340-2591 1 Valve Shut-off Knob
7 340-2004 1 Timer Cover
8 340-1991 1 Diffuser
9 340-2585 4 Strainer Knob
10 1121-2008 1 1/4" Pipe Plug w/o-ring
10a 308-1011 1 Pipe plug O-ring
11 1121-1497 1 Motor Housing Bumper - Top
12 340-2054 1 Motor Housing Bumper - Bottom
13 1107-2482 1 Backplate
14 1107-1513 1 Impeller Assembly - 1 H.P.
1107-1514 1 Impeller Assembly - 1-1/2 H.P.
15 1107-2483 1 Strainer Lid Assembly
16 303-1109 1 Switch (UL/CSA)
17 1100-1696 1 Power Cord - 25' GFCI
1100-1115 1 Power Cord - UL/NEC
• 340-2607 1 Strainer cover wrench (not shown)
18 303-1110 1 Knurled Ring Nut (UL/CSA)
19 300-1091 1 Motor - 1 H.P.
300-1092 1 Motor - 1-1/2 H.P.
20 308-1227 1 O-Ring - 2.609 I.D.
21 308-1228 1 O-Ring - 6.975 I.D.
22 308-1229 1 O-Ring - 8.475 I.D.
23 308-1009 1 O-Ring - .487 I.D.
24 308-1202 1 3/4" Shaft Seal
25 308-1231 1 3/4" Pump Seal Seat
26 1121-1495 1 3/4" Pump Seal Set
27 310-1054 1 Foam Baffle
28 330-1239 4 3/8-16 x 2-1/2" Carriage Bolt
29 330-1219 4 5/16-18 x 1" Bolt
30 330-1240 1 #10-24 x 1" Screw
31 330-1241 5 #10 x 5/8" Screw
32 327-1020 4 5/16" Flat Washer
33 327-1063 1 #10 Flat Washer
34 327-1036 1 #8 Ext. Tooth Lockwasher
35 340-2485 2 Union Socket
36 340-2484 2 Union Nut
37 308-1241 2 O-Ring - 1.984 I.D.
38 340-2502 2 Union Hose Adaptor
39 303-1715 1 Strain Relief Bushing
40 1100-1400 1 Jumper Wire (UL/CSA)
41 387-1023 1 #28 Band Clamp
42 348-1036 1 Hard Plumb Adaptor
43 387-1024 1 #36 Band Clamp
44 — 1 Warranty Card
45 365-2074 1 Owner's Guide
4
OWNER'S GUIDE
WARRANTY CARD
45
44
EXPLODEDVIEW
UL Models: 0-3496-200 (1 HP), 0-3497-200 (1-1/2 HP) w/GFCI
NEC Models: 0-3496-206 (1 HP), 0-3497-206 (1-1/2 HP)
Note: Items 41, 42 & 43 are for hard plumbing 1-1/2" PVC pipe or flex pipe to the skimmer bottom.

DOUGHBOY RECREATIONAL • 315 North Sebastian St. • West Helena, AR 72390
Visit our website at: www.doughboy-pools.com
DB0912-624 Made in the United States of America Copyright © 2012
Change of Design: Doughboy Recreational expressly reserves the right to changeor modify thedesign and construction
ofanyproductinduecourseofourmanufacturingprocedures,withoutincurringanyobligationorliabilitytofurnishorinstall
such changes or modifications on products previously or subsequently sold.
This manual suits for next models
4
Table of contents
Other Doughboy Swimming Pool Pump manuals
Popular Swimming Pool Pump manuals by other brands

Davey
Davey Silensor SLS100 Installation and operating instructions

hydro-s
hydro-s 7029988 User and service manual

Pentair
Pentair WhisperFlo Installation and user guide

Everbilt
Everbilt SPP15002 Use and care guide

Oasis Aquatics
Oasis Aquatics V Series Installation and operation manual

Pulsar
Pulsar 79214 1 HP owner's manual

DPL Pool Equipment
DPL Pool Equipment 50HPRA-410 owner's manual

Outbound
Outbound SKIMMERPLUS SFX600 operating instructions

Pentair
Pentair PUMP Installation and user guide

Waterway
Waterway SVL56 owner's manual

Calpeda
Calpeda MPC operating instructions

Pacific hydrostar
Pacific hydrostar 95591 - .75 HP Set up and operating instructions