07-00213C 1 Dri-Eaz Products, Inc.
F174-230V, -230V AU, -230V BE, -230V BLU, -230V PB, -UK
Axial Airmover Owner’s Manual
Models: F174-230V, -230V AU, -230V BE, -230V BLU, -230V PB, -UK
DRI-EAZ PRODUCTS, INC.
LEGEND BRANDS EUROPE
15180 Josh Wilson Road, Burlington, WA 98233, USA
22 Plover Close, Interchange Park, Newport Pagnell, MK16 9PS
Phone: 800-932-3030 Fax: 360-757-7950
www.DriEaz.com
Tel: +44 (0)1908-611-211 Fax: +44 (0)1908-611-363
www.LegendBrandsEurope.com
The Vortex™airmover ventilates confined spaces and propels dry air across large open areas to aid in drying. It may also be
used to improve indoor air quality and remove unwanted odors. Suitable for use with up to 125 ft. of semi-rigid ducting.
Patents: http://www.LBpatents.com
R E A D A N D S A V E T H E S E I N S TR U C T I O N S
WARNING! Do not alter or modify
your dehumidifier in any way. Use
only replacement parts authorized
by Dri-Eaz Products, Inc.
Modifications or use of unapproved parts could
create a hazard and will void your warranty. Contact
your authorized distributor for assistance.
WARNING! Electric shock hazard, rotating fan
hazard and hot surface hazards.
Inspect the power cord before use. If cord is
damaged, do not use. Always grasp the plug (not
the cord) to unplug.
Must be earthed. Insert three-prong plug on power
cord into a matching electrically earthed outlet. Do
not use adapter. Never cut off third prong. Do not
use an extension cord.
The unit must be operated on a 230V/50 Hz circuit
protected by a Residual Current Device (RCD)
device.
Keep motor and wiring dry.
Always unplug unit before cleaning or servicing.
Do not attempt to repair the unit. For service, contact
your local distributor.
FIRE HAZARD
Keep away from open flames and heat sources.
Do not use or store where vapors from gasoline,
solvents, thinners or other flammable materials may
be present.
GROUNDING INSTRUCTIONS
This unit’s plug must be inserted into an appropriate
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
WARNING! Improper connection of the equipment-
grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service
person if you are in doubt as to whether the outlets
are properly grounded. Do not modify the plugs
provided with the appliance –if the plugs do not fit
the outlets, have proper outlets installed by a
qualified electrician.
This equipment is for use on circuits with a nominal
rating of no more than 230V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do
not drop, throw, or place where it could fall. Rough
treatment can damage the unit, and may create a
hazardous condition or void the warranty.
07-00213C 2 Dri-Eaz Products, Inc.
F174-230V, -230V AU, -230V BE, -230V BLU, -230V PB, -UK
This unit intended for household and commercial use.
BEFORE YOU BEGIN
Warranty registration
Warranty registration procedures vary by region. Contact
your local distributor for assistance. Registration allows
us to better assist you with using, maintaining or
servicing your equipment and to contact you in case we
have important safety information concerning your Dri-
Eaz product. If you determine service is required, have
your equipment model, serial number and original proof
of purchase available and ask for assistance with
obtaining a return material authorization (RMA).
OPERATING INSTRUCTIONS
The Vortex Axial Fan is designed for air ventilation,
circulation, and extraction, and for drying of wet
materials and structures with airflow.
The Vortex can be used with or without attached ducting.
It is useful for either positive or negative airflow, that is,
blowing air into or extracting air from spaces. An arrow
on the housing indicates air direction.
Inspect the inlet and outlet screens before plugging in
the unit, and remove any debris that may restrict airflow.
When Used with Ducting
Do not install ducting when the Vortex is operating. To
install ducting, first note the direction of airflow. Place
end of ducting over the duct ring and attach securely.
Ducting to fit the Vortex is available from your Dri-Eaz
distributor. Ducting has quick connect straps plus a
snap-in ring used to fasten two sections of ducting
together.
Confined Space Ventilation
Position the Vortex at least five feet away from the entry
to the confined space. Place it upwind so that purged
gases do not re-enter the unit. Make sure the inlet is not
blocked by a wall or other obstruction.
Place the other end of the ducting in the confined space,
angled so it points at an end wall. Keep it pointed at an
end wall to prevent pockets of unmoving air, and to keep
fresh air circulating to all locations.
MAINTENANCE
CAUTION: Internal repair procedures should be
performed by a qualified technician from an
authorized service center.
WARNING: Disconnect from electrical supply prior to
servicing or cleaning.
Cord Inspection: Inspect the electrical cord for damage.
Units with damaged cords must be removed from
service and repaired before use. Failure to do so may
lead to electrical shock or a fire hazard.
Exterior Inspection: Evaluate exterior components and
make sure that all are in proper operating condition.
Repair or replace components as required. Run the unit
briefly; listen for abnormal sounds and repair as needed.
Clean Exterior: Clean the exterior plastic housing with
mild detergent and water. For deep cleaning and a
lasting, protective shine, use a vinyl cleaner and
protectant.
Motor Bearings: The bearings on the Dri-Eaz Vortex
are permanently lubricated. No oiling is necessary.
For parts and service, contact your local Dri-Eaz
distributor
ADDITIONAL PRODUCT INFORMATION and current
documentation is available at
www.DriEaz.com
www.LegendBrandsEurope.com
FOR PARTS AND SERVICE contact your local
distributor.
SPECIFICATIONS
Fan speed
2850 RPM
Max. static pressure
5.6 cm | 2.2 in. H2O
Dimensions (D × W × H)
24.6 × 26.2 × 18.2 in.
18 × 15 × 19 in.
Weight
15 kg | 33 lbs.
Amps
2.2 amps
Volts
230V
Frequency
50Hz
Power (motor rating)
1.0 HP
Cord length
20 ft. | 6.1 m
Control
1 speed toggle switch
Safety
Listed to UL/ULc standards
Specifications are subject to change without notice. Some values
may be approximate.

This manual suits for next models

5

Other Drieaz Fan manuals

Drieaz Ace TurboDryer F259-115V User manual

Drieaz

Drieaz Ace TurboDryer F259-115V User manual

Drieaz Velo User manual

Drieaz

Drieaz Velo User manual

Drieaz Stealth AV3000 User manual

Drieaz

Drieaz Stealth AV3000 User manual

Drieaz VORTEX F174 User manual

Drieaz

Drieaz VORTEX F174 User manual

Drieaz Vortex User manual

Drieaz

Drieaz Vortex User manual

Drieaz TurboDryer Sahara E User manual

Drieaz

Drieaz TurboDryer Sahara E User manual

Drieaz Velo User manual

Drieaz

Drieaz Velo User manual

Drieaz Velo User manual

Drieaz

Drieaz Velo User manual

Drieaz TurboDryer Vortex User manual

Drieaz

Drieaz TurboDryer Vortex User manual

Drieaz Ace TurboDryer User manual

Drieaz

Drieaz Ace TurboDryer User manual

Popular Fan manuals by other brands

DuraVent DURATECH PREMIUM Installation and operation instructions

DuraVent

DuraVent DURATECH PREMIUM Installation and operation instructions

Ellington WOD52ABZ5PC1 installation guide

Ellington

Ellington WOD52ABZ5PC1 installation guide

Hunter 9800001139 Parts guide

Hunter

Hunter 9800001139 Parts guide

Greenheck AER Installation, operation and maintenance manual

Greenheck

Greenheck AER Installation, operation and maintenance manual

Mars Comfort-Aire FB-2430DT-MBL Series owner's manual

Mars

Mars Comfort-Aire FB-2430DT-MBL Series owner's manual

BRAYER BR4960 instruction manual

BRAYER

BRAYER BR4960 instruction manual

Panasonic Whisper Green FV-08VK1 installation instructions

Panasonic

Panasonic Whisper Green FV-08VK1 installation instructions

mtts Beluga-V1 user manual

mtts

mtts Beluga-V1 user manual

Hunter Parkview 50999 installation manual

Hunter

Hunter Parkview 50999 installation manual

Panasonic F-56MPG Operating and installation instructions

Panasonic

Panasonic F-56MPG Operating and installation instructions

Draper FAN7C user manual

Draper

Draper FAN7C user manual

Soleus Air FC3-35R-12 owner's manual

Soleus Air

Soleus Air FC3-35R-12 owner's manual

Lasko 1850 Important instructions & operating manual

Lasko

Lasko 1850 Important instructions & operating manual

UNITED UUF-611 instruction manual

UNITED

UNITED UUF-611 instruction manual

Euromatic TF116RC user manual

Euromatic

Euromatic TF116RC user manual

Xtricity 4-80322 instructions

Xtricity

Xtricity 4-80322 instructions

comfort air CH-V4 instruction manual

comfort air

comfort air CH-V4 instruction manual

Rubine FABIO Series user manual

Rubine

Rubine FABIO Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.