OPERATING MANUAL

DuraSprayerII™ OPERATING MANUAL
Thank you and Congratulations on your choice of the DuraSprayerII™, a
revolutionary disinfectant delivery system that uniquely combines the
technology of foggers, misters, refillable sprayers, and prepackaged aerosols.
This refillable unit eliminates the need for costly prepackaged aerosols by
mechanically generating the most optimum-sized, uniform disinfectant particles.
Its unique design allows you to treat more area per ounce than with pre-packaged
aerosol products.
Its handy size and its portability make it an invaluable tool for use in your home,
office, gym both residential and light commercial accounts. In addition, it gives
you the flexibility of using a variety of disinfectants that are EPA approved for
use in this type of equipment.
Manufactured for:
39 Western Highway
West Nyack, NY 10994
877-561-0500

Page 1
Table of Contents
OPERATING INSTRUCTIONS Page 2-4
DISINFECTANTS Page 2
RECHARGING Page 4
EQUIPMENT SPECIFICATIONS Page 5
PARTS AND SERVICE Page 6-7
DIAGNOSIS AND FIELD SERVICE Page 6
WARRANTY Page 8

Page 2
OPERATING INSTRUCTIONS
Handle with care.
Always wear personal protective equipment (PPE)
When filling these units always wear protective eyewear and protective gloves.
When operating these units, always wear protective clothing, eyewear, chemical
resistant rubber gloves, and a respirator. Refer to the disinfectant label for
specific instructions and other precautions.
Preparations and Guidelines when applying Aerosol Disinfectants.
Refer to disinfectant label for directions on proper preparation for area to be
treated before operating this equipment. General preparation includes:
Everyone in the treatment area must wear an approved respirator during
treatment and when re-entering a treated area when the aerosol may still be
present. Turn off all pilot lights or sources of open flame. Ventilation systems
and air moving systems should be turned off. Appliances that routinely create
high heat should be turned off. Computers and other electrical equipment should
be turned off, covered, or removed from the treatment area.
All personnel without proper PPE must leave the treatment area. Cover or
remove ornamental plants. Cover and seal all aquariums. Aquarium filters must
be shut off and not turned back on until the aerosol is no longer present. Pets,
including exotic pets (birds, amphibians, reptiles, arachnids) must be removed.
Re-entry for exotic pets is not recommended for a period of 24 hours.
All exposed food must be removed or placed in containers that will prevent
contact with the disinfectant. Food preparation utensils and surfaces must be
covered or cleaned thoroughly before reuse. Close and lock all entry ways.

Page 3
Professionals may want to consider posting warning signs on doors opening into
the treatment site. Open all doors, cabinets, storage areas, and drawers in the
treatment area.
Observe Label Directions of Disinfectant Solution:
Do not operate the DuraSprayerII™ with disinfectants that are not labeled for
aerosol, fog, or mist applications. Read the disinfectant label to determine if the
disinfectant is EPA-approved for use in this type of equipment. Contact your
chosen distributor for information on disinfectants currently labeled for use in
equipment such as DuraSprayerII™
Prepare Disinfectant Solution:
Must follow all directions on the packaging of the disinfectant. Some solution
comes ready to use. Some needs to be pre-mixed.
Fill Tank with Disinfectant:
Remove white container by unscrewing from the main sprayer unit. Once
container is filled, place the tubing into container and carefully screw the
container back on to the sprayer unit until it is hand tight. There is no filter, so
be sure to remove any debris that you notice that may clog or damage the
DuraSprayerII™ equipment.
Turn the unit on to begin use:
Push the On/Off button on the back of the unit. The solution will start to flow;
keep the sprayer in motion, making sure to cover all areas.
Flush System After Every Use to Remove Chemicals
This procedure is highly recommended and is the most important maintenance
you can do for your sprayer. Simply place the tubing into a water and run for
one minute to clean out the disinfectant from the sprayer.
Draining the Container.
Empty the DuraSprayerII™ container when changing disinfectants or storing for
an extended period of time. Also wash with water and let it dry before storing.
Transporting the Unit.
If transporting the DuraSprayerII™ with disinfectant in the container, it must be
kept in an upright position. Container must be emptied if this is not possible. If
the solution leaks into the motor, it could damage it (This is not covered under
the warranty).

Page 4
Recharging the DuraSprayerII™
When fully charged, the four lights on the back light up. If only one or no light
is showing, the unit needs to be recharged for 4 hours. Simply lift up on the back
of the battery and pull it out. Plug the charger into the battery and leave until
fully charged.
Battery LED lights

Page 5
DuraSprayerII™ SPECIFICATIONS
Length
13.8”
Width
3.2”
Height
5.9”
Weight (empty)
3 lbs.
Weight (full)
6 lbs.
Shipping Weight
4 lbs.
Tank Capacity
1/2 gallon (1.8 liters)
Voltage
20V
Spraying Distance
9-16 feet
Motor
6 amps, 129 watts
Noise Level
~75 DB
Operating Time
25-30 minutes

Page 6
PARTS
Parts for the DuraSprayerII™ can be ordered through your chosen distributor.
Or, for your convenience, we maintain a large inventory of replacement parts
which can easily be ordered and shipped directly from our factory to you.
Call Today: 1-877-561-0500 we accept:
SERVICE
If the DuraSprayerII™ requires factory service be sure to drain the tank, back
flush the wand and hose, and pack the unit in its original carton and packing
material for shipping. If the original carton is not available, pack the unit a
durable box and protect the unit as best you can. If using foam packing materials
be sure to place the unit in a plastic bag before adding materials to carton.
Ship the unit with a description of the problem, a contact name and phone
number, and a return shipping address to:
Duraline Systems, Inc.
39 Western Highway
West Nyack, NY 10994
NOTE: Post Warranty service will be billed for parts, labor, packaging (if
needed), and freight.
DIAGNOSIS AND FIELD SERVICE
If none of these solutions corrects your problem, there may be something more
serious wrong with the unit. For additional technical assistance please contact
Duraline Systems, Inc. Help Desk at 877-561-0500.

Page 7
DuraSprayerII™ Parts List
Description
Reorder No.
Sprayer Unit
C-DSDII-SU
Battery Pack
C-DSDII-BP
1.8 Liter Bottle
C-DSDII-B
Charger
C-DSDII-C

PRODUCT LIMITED WARRANTY
Duraline Systems, Inc. products are warranted to be defect free in materials and
workmanship under normal use, for a period of 90 days from the date of
purchase.
Duraline Systems, Inc. shall not be liable for freight damage incurred during
shipping. Package returns carefully. If the original carton is not available, pack
the unit in a durable box and protect the unit as best you can.
Duraline Systems, Inc.’s obligation under this warranty policy is limited to the
repair or replacement ofthe unit. All returns will be tested per Duraline Systems,
Inc. factory criteria. Units found not defective, under the terms of this limited
warranty, are subject to the charges paid by the returnee.
Warranty replacement will be shipped on a freight allowed basis Duraline
Systems, Inc. reserves the right to choose the method of transportation.
This limited warranty is in lieu of all other warranties, expressed or implied, and
no other person is authorized to give any other warranty or assume obligation or
liability on Duraline Systems, Inc.’s behalf. Duraline Systems, Inc. shall not be
liable for any labor, damage or other expense, nor Duraline Systems, Inc. be
liable for any indirect, incidental or consequential damages of any kind incurred
by the reason of the use or sale of any defective product or part.
Return Policy
All units must be flushed of any chemicals before shipping. Carriers, including
U.S.P.S., airlines, UPS, ground freight, etc. require specific identification of any
hazardous materials to be shipped. Failure to do so may result in a substantial
fine and/or prison term. Check with your shipping company for specific
instructions.
All Units must be flushed of any chemical (ref. OSHA Section 1910.1200
(d)(e)(f)(g)(h)) and NO hazardous chemicals will be accepted for service or
warranty consideration Duraline Systems, Inc. reserves the right to request a
Material Safety Data Sheet from the returnee for any product it deems necessary.
Duraline Systems, Inc. reserves the right to “disposition as scrap” any products
returned which contain unknown fluids. Duraline Systems, Inc. reserves the right
to charge the returnee for all costs incurred for chemical testing and proper
disposal of components containing unknown fluids. Duraline Systems, Inc.
requests this in order to protect the environment and personnel from the hazards
of handling unknown fluids

Manufactured for:
39 Western Highway
West Nyack, NY 10994
877-561-0500
Copyright© 2020 Duraline Systems,
Table of contents
Other Duraline Systems Paint Sprayer manuals