Dynacord | DCS 412R
DCS 412R
www.dynacord.com
▪12 inputs
▪The polarity for each input can be freely selected
▪Each input is isolated by separating the wire
jumpers
▪Pluggable connection terminals for power supply to
the buttons, contacts, and sensors
The module is fitted on the back of the DCS 400 rack
plug-in board. The module is used to connect control
cables, buttons, switches, and sensors in order to
check their status (on, off) in the PROMATRIX 8000
system.
Additional properties:
• Pluggable connection terminals with screwed flange
for all inputs
• A maximum of 5 DCS 412R modules can be cascaded
Parts included
No. Component
1 DCS 412R
2 Plug, 15-pin (Phoenix MC 1.5/15-STF-3.81 - 1827839)
Technical specifications
Operating voltage 24 V DC, -10%/+30%
Operating current, all inputs open
• Standby/Idle/
Announcement/Alert
24 V, 83 mA, 2.00 W
Electromagnetical environment E1, E2, E3
Operating temperature -5 °C to 45 °C
Product dimensions (Width by
Height by Depth)
37.5 by 80.6 by 245 mm
Net weight 175 g
Input level
• Input voltage for off (Low) U_IN < ±5 V
• Input voltage for on (High) U_IN > ±10 V
• Input current at U_IN = 24 V I_IN = 4.8 mA
• Input voltage max. U_IN max = ±31 V
Output source 24 V
• Output current max. 90 mA