Page 8
3101B-TJ101 INSTALLATION MANUAL
MODEL3101B-TJ101
ELECTROMAGNETIC LOCK
MOUNTING INSTRUCTIONS
02/11
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
Page 1
3101B-TJ101 INSTALLATION MANUAL
MODEL 3101B-TJ101
ELECTROMAGNETIC LOCK
MOUNTING INSTRUCTIONS
02/11
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
FOR PRODUCT SUPPORT AND PARTS
ORDERING INFORMATION CONTACT:
DynaLock Corp.
705 Emmett Street
Bristol, CT 06010
Bus: (877) 396-2562 Toll-Free
(860) 582-4761
Fax: (860) 585-0338
DYNALOCK ON THE INTERNET:
E-mail: [email protected]
Website: www.dynalock.com
PLEASE DELIVER THIS MANUAL
TO THE END-USER UPON COMPLETION
OF THE INSTALLATION
Familiarize yourself with the door and frame conditions. The lock must mount rigidly to the face of the door frame
header. The door mounted armature is supplied with an adjustable mounting bracket and hardware that allows it
to pivot slightly to compensate for reasonable misalignment.
NOTE: If this lock is supplied with the DSM option be certain that disc magnets are present inside the
armature housing.
Care must be taken that the lock face and armature face are kept free of dirt, rust, paint, or any other obstruction
which may interfere with the lock and armature making good contact. These faces may be cleaned with a non-
abrasive pad and wiped with an oil dampened cloth.
The Series 3101B-TJ101 is a 1500 pound holding force delay egress top jamb-mounted electromagnetic lock designed
to secure a single-inswinging door. The lock requires both installation procedures as described herein and in the
separate wiring instructions included.
Note: This device is not intended for use on emergency exit doors.
Typical installations of the lock on single-inswing doors:
HANDLING
MECHANICAL INSTALLATION
ELECTRICAL INSTALLATION
After mechanical installation is complete the lock needs to be wired to a 12 or 24 VDC/VAC power source. Once low
voltage power is supplied the unit is fully operational. All other wiring is for selected options. Refer to the separate
wiring instructions included for further information.
INSTALLATION DESCRIPTION
LEFT HAND DOOR RIGHT HAND DOOR
GWXT Auxiliary Lock
FWAX Special Locking Arrangements
CSFM California State Fire Marshal
Page 2
3101B-TJ101 INSTALLATION MANUAL
MODEL 3101B-TJ101
ELECTROMAGNETIC LOCK
MOUNTING INSTRUCTIONS
02/11
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
Page 7
3101B-TJ101 INSTALLATION MANUAL
MODEL 3101B-TJ101
ELECTROMAGNETIC LOCK
MOUNTING INSTRUCTIONS
02/11
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
MOUNTING CONSIDERATIONS
INSTALL THE LOCK ASSEMBLY
Individual door and frame
conditions may vary. Dimensions
shown at right are for a typical
hollow metal door and frame.
The lock assembly should be
mounted closest to the strike
jamb of the frame for maximum
performance. Verify that there
is proper clearance for the
lock assembly at the planned
mounting location.
1.
2.
Drill out the four dimpled mounting hole locations inside the
back of the lock housing using a 5/32” drill. Position the lock
assembly on the face of the frame header, on the pull side of
the door, as shown. Locate and mark the centers of the four
mounting holes.
Drill the marked holes in the face of the frame header:
Four (4) 5/32” dia. mounting holes.
Attach the lock assembly to the frame header using four (4)
#14-1½ pan head wood screws or 10/32 x 1¾ philips pan head
machine screws. Firmly tighten the screws using a #2 phillips
screwdriver.
1.
2.
3.
4-7/16” 1/4”
TYP.
1-1/4”
1/4”
REF. 2-3/4”
REF.
5-1/8”
REF.
ARMATURE BRACKET
MOUNTING SCREW
DOOR
SEX NUT
1/8”
GAP
1/8”
GAP
LOCK ASSEMBLY
ARMATURE
EXPLODED PARTS VIEW
Note: Refer to Page 6 for parts legend.
MOUNTING HOLES MOUNTING HOLES
1/8”
ABOVE
HEADER RABBETT
1/8”
ABOVE
HEADER RABBETT
FLUSH WITH
FRAME RABBETT
FLUSH WITH
FRAME RABBETT
LEFT HAND DOOR
HINGE SIDE HINGE SIDE
RIGHT HAND DOOR
LED & KEYSWITCH
PLUG INTO CIRCUIT BOARD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18 19 20
26
22
21
25
24
23
Page 6
3101B-TJ101 INSTALLATION MANUAL
MODEL 3101B-TJ101
ELECTROMAGNETIC LOCK
MOUNTING INSTRUCTIONS
02/11
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
Page 3
3101B-TJ101 INSTALLATION
MODEL 3101B-TJ101
ELECTROMAGNETIC LOCK
MOUNTING INSTRUCTIONS
02/11
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
EXPLODED PARTS VIEW LEGEND
Refer to Page 7 for parts locations.
ATTACH THE ARMATURE TO THE ARMATURE MOUNTING BRACKET
ASSEMBLE THE ARMATURE MOUNTING BRACKET
Locate the two armature mounting bracket
assembly screws and lock washers from
the hardware kit and assemble the bracket
as shown.
Firmly tighten the mounting screws with a
5/32” hex wrench. They may be loosened
later for adjustment, as necessary.
Attach the Armature Housing to the top Armature Mounting Bracket as shown below. (See Exploded Parts View
on page 7).
Failure to properly secure the armature to the bracket could result in serious injury or possible security
breach.
UPPER ARMATURE
BRACKET
LOWER ARMATURE BRACKET
LOCK WASHER
BRACKET ASSEMBLY SCREW
ITEM DESCRIPTION PART #
**1
**2
8-32 x ¼” PHILIPS FLAT HEAD 300541
*14 1½” PAN HEAD SCREWS 301218
3END COVER 300010
4
ACCESS COVER / EGRESS SENSOR
LOCK HOUSING N/A
5301037
66-32 x 5/16” STANDOFFS 301231
77050xLEDxUS32D N/A
86-32 x 7/8” STANDOFFS 301232
9ELECTRONICS COVER 300353
10 6-32 x ½” SECURITY SCREW 700058
**11
¼-20 x ½” HEX BOLT
300738
**12 ¼” TOOTH LOCK WASHER 300742
13 UPPER ARMATURE BRACKET 301254
14 ARMATURE MOUNTING PLATE ASSEMBLY 301038
15 WHEEL KIT ASSEMBLY 301393
16 ARMATURE HOUSING 301334
**17 8-32 x ½” PHILIPS FLAT HEAD 301005
18 ARMATURE 300373
**19 ARMATURE SPRING 300753
**20 ARMATURE SPACER 300002
**21 5/16-18x2” FHS 300018
22 BOTTOM ARMATURE BRACKET 301260
*#10/32x1” TYPE F PHILIPS PAN HEAD (FOR METAL APPLICATION)
** PART OF HARDWARE PACK 301417
23 3101B-TJ SPACER SHIM 301411
**24 SEX NUT 300004
**25 SPACER TUBE 300001
**26 5/16”-18x1” FHS TURNED 300374
Page 4
3101B-TJ101 INSTALLATION MANUAL
MODEL 3101B-TJ101
ELECTROMAGNETIC LOCK
MOUNTING INSTRUCTIONS
02/11
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
Page 5
3101B-TJ101 INSTALLATION MANUAL
MODEL 3101B-TJ101
ELECTROMAGNETIC LOCK
MOUNTING INSTRUCTIONS
02/11
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
INSTALL THE ARMATURE MOUNTING BRACKET
Drill an 11/32” diameter hole
through door. From sex nut
side only enlarge the 11/32”
hole to 21/32” diameter.
Drill an 11/32” diameter hole
through door. From sex nut
side only drill 1/2” diameter
hole to 1” depth.
Drill an 11/64” diameter hole
and tap for 5/16”-18 thread.
GLASS & ALUMINUM
OR HOLLOW METAL DOOR
SOLID CORE DOOR REINFORCED DOOR
Use the gures below to identify and mark the locations of the armature mounting bracket screw holes on the door.
Refer to door and frame prep drawing #301416 for further information.
1.
From the illustrations below select the one that resembles your door type and follow the instructions for drilling the
two (2) armature mounting bracket screw holes.
2.
Mount the armature and mounting bracket assembly to the door using the appropriate hardware for you door type.
Firmly tighten the mounting screws with a 3/16” hex wrench.
3.
ARMATURE ADJUSTMENT
Using a 5/32” hex wrench, temporarily
loosen the armature bracket assembly
screws roughly 1-1/2 turns to allow the
upper armature bracket to move in and out
freely (Ref. Figure “A”).
Close and latch the door. The mating
surfaces of the lock and armature should
fully contact each other. If necessary, slide
the armature in or out to ensure full contact
is made with the lock while still allowing the
door to properly close and latch.
When the desired adjustment is achieved,
slowly open the door taking care to maintain
the position of the armature. Firmly tighten
the armature bracket assembly screws,
making sure that the locking ribs on the
upper and lower bracket halves properly
mesh (Ref. Figure “A”)
1.
2.
3.
Figure “A”
ASSEMBLY
SCREW
UPPER ARMATURE BRACKET
LOWER
ARMATURE
BRACKET
NOTE:
Make sure the door hits the frame just
before the armature hits the maglock, to
prevent loosening over time (armature not
slamming against the lock).
1-5/8”
FROM
FRAME
RABBETT
7-3/4”
1-3/8”
FROM
HEADER
RABBETT
HINGE SIDE OF DOOR
1-3/8”
FROM
HEADER
RABBETT
1-5/8”
FROM
FRAME
RABBETT
7-3/4”
HINGE SIDE OF DOOR
LEFT HAND DOOR RIGHT HAND DOOR
DOOR
LOCK ASSEMBLY
ARMATURE
SHIM PLATE
ARMATURE BRACKET
ADJUSTMENT RANGE
1/8” 1”
^^^^^^^^^^^^^^^^^^^^^^^^^^^^
DOOR
SPACER
LOWER ARMATURE
MOUNTING BRACKET
ARMATURE BRACKET
MOUNTING SCREW
SEX NUT
21/32”
SHIM PLATE
^^^^^^^^^^^^^^^^^^^^^^^^^^^^
LOWER ARMATURE
MOUNTING BRACKET
ARMATURE BRACKET
MOUNTING SCREW
½”
1” SHIM PLATE
^^^^^^^^^^^^^^^^^^^^^^^^^^^^
1/4” MIN
LOWER ARMATURE
MOUNTING BRACKET
ARMATURE BRACKET
MOUNTING SCREW
SHIM PLATE
5/16”-18
THREAD

Other manuals for 3101B-TJ101

1

Other DynaLock Lock manuals

DynaLock 3101B-TJ101 User manual

DynaLock

DynaLock 3101B-TJ101 User manual

DynaLock 3101C-TJ101 User manual

DynaLock

DynaLock 3101C-TJ101 User manual

DynaLock 3000 Series User manual

DynaLock

DynaLock 3000 Series User manual

DynaLock 3000LC Series User manual

DynaLock

DynaLock 3000LC Series User manual

DynaLock 2013 User manual

DynaLock

DynaLock 2013 User manual

Popular Lock manuals by other brands

Primera SAFEHINGE RHINO-LOCK PR-6304-RB-RK-LL manual

Primera

Primera SAFEHINGE RHINO-LOCK PR-6304-RB-RK-LL manual

Accuride Senseon 10EL quick reference

Accuride

Accuride Senseon 10EL quick reference

National Cabinet Lock C8113 Dimensional drawing

National Cabinet Lock

National Cabinet Lock C8113 Dimensional drawing

COMPX Timberline CB-234 instruction sheet

COMPX

COMPX Timberline CB-234 instruction sheet

DOM E10S-mini instructions

DOM

DOM E10S-mini instructions

Schlage B-Series installation instructions

Schlage

Schlage B-Series installation instructions

Weiser kevo Touch-to-Open quick start guide

Weiser

Weiser kevo Touch-to-Open quick start guide

Trilock G2 Series installation instructions

Trilock

Trilock G2 Series installation instructions

GEONFINO G4PRO installation instructions

GEONFINO

GEONFINO G4PRO installation instructions

Soyal AR-1207A-29 quick start guide

Soyal

Soyal AR-1207A-29 quick start guide

Securam ProLogic B22 Operation instructions

Securam

Securam ProLogic B22 Operation instructions

Simons Voss Technologies Cylinder AX Modularity manual

Simons Voss Technologies

Simons Voss Technologies Cylinder AX Modularity manual

M-LOCKS Straightbolt EM3520 Mounting instructions

M-LOCKS

M-LOCKS Straightbolt EM3520 Mounting instructions

Windsor 1390 Programming instructions

Windsor

Windsor 1390 Programming instructions

Cal-Royal ES1520 Series installation instructions

Cal-Royal

Cal-Royal ES1520 Series installation instructions

Motormate Yamaha 10-303A SHO installation instructions

Motormate

Motormate Yamaha 10-303A SHO installation instructions

Kaba Simplex 7104 Series instructions

Kaba

Kaba Simplex 7104 Series instructions

Moulure Alexandria Moulding PDA02-00CSN installation instructions

Moulure Alexandria Moulding

Moulure Alexandria Moulding PDA02-00CSN installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.