E-Tech ET8 User manual

USER’S MANUAL
Versions commencing November 2001A$12.00 INC GST
E-TECH ET8 CONTROL PANEL V4 – USER’S MANUAL, REVISION 1
E-TECH ET8 ALARM CONTROL PANEL AND DIALLER

“Australia’s largest
designer and
manufacturer of
high quality
security products”
E-Tech Security Products Pty Ltd
Quality
Endorsed Fictional
Company
ISO9001
LIC.No. QEC2074
NSW Head Office only
HEAD OFFICE:
E-Tech Security Products Pty Ltd
ABN 000 110 110
12 Security Close
Safe Hills NSW 2147 Australia
Ph +61 23 9988 7766
Fax +61 23 9988 7765
ET8 V4 INSTALLER MANUAL
Revision 1, November 2001
Document Part Number: 890–265
For product:
100–191 ET8 LED Control Panel (V4)
100–688 ET8 LCD Control Panel (V4)
© 2001 E-Tech Security Products Pty Ltd ACN 000 110 110
ET8 V4 installer
Specifications may change without notice.
E-TECH SECURITY PRODUCTS
TELECOMMUNICATIONS COMPLIANCE
Australian Communications Authority

CONTENTS
Features ...................................................................... 4
Introduction ................................................................. 5
Keypad ........................................................................ 6
Keypad Indicators ...................................................... 7
OPERATION by KEYPAD ........................................... 8
Arming ...................................................................... 9
Disarming .............................................................. 10
Resetting Alarms ................................................... 10
Monitor Mode ........................................................ 11
Panic ...................................................................... 12
Duress .................................................................... 12
Fire Alarm .............................................................. 13
Medical Alarm ....................................................... 13
Excluding Zones ................................................... 14
Alarm Memory ....................................................... 15
OPERATION by RADIO KEY..................................... 16
PROGRAMMING ....................................................... 17
Programming Options Table ................................ 17
User Code programming ...................................... 18
Entry/Exit Timer programming ............................. 18
Telephone Number programming ....................... 19
Monitoring, Central Station ...................................... 20
Monitoring, Audible .................................................. 21
Wireless Accessories ............................................... 20
Remote Operation by Telephone ............................ 22
E-TECH ACCESSORIES ......................................... 24
Wireless Accessories ........................................... 25
Troubleshooting ........................................................ 26
Installation Record.................................................... 27
OPERATION SUMMARY .......................................... 28

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL
4
• 8 Fully programmable zones
• Any combination of hardwire or radio
zones
• Full radio supervision
• Contact ID Dialler Format
• Ultra-Modern and Impact resistant
Housing
• E-Tech Audible Dialler Format
• "Follow Me" Audible Dialler Option
• Separate 24 HourTamper input
• Single or DoubleTrigger Zones
• Remote LED or LCD Keypads (Max 3)
• Fully programmable via the system
Keypad - Eliminates the need for
expensive programmers or Proms.
• InbuiltVibration Sensor Analyser
• All programming data is permanently
stored in a non-volatile EEprom
memory
• Windows based Up\Down load
Software allows remote programming
and event status
• True Dynamic BatteryTest every time
the Panel is armed / disarmed and
every hour
• Area Partitionable (2 Areas).Any Zone
can be programmed to any area, as
well as common areas
• Comes complete with an AC plug
pack and supports a 12V 7Ah
battery to maintain systems security
under all power supply conditions
• Monitor Mode (Home Mode)
• Outputs are separately fused with
Automatic Reset Fuses
• Day Mode and Door Chime feature.
• 30 Event Memory
• Supports 8 Radio Devices (Radio
PIRs, Radio Reeds etc)
• Supports 14 Radio Keys
• All inputs and outputs are heavily
protected against lightning and high
voltage supply transients.An earth
terminal is provided for extra protec-
tion
• 15 User Codes
• ‘Arm only’codes can be programmed
• Programmable Inputs to activate
selectable Outputs
• Designed utilising the latest SMD
Technology
• Simple to Program and Use.
E-TECH ET8 FEATURES

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL 5
INTRODUCTION
The E-Tech ET8 micro computer based 8 zone
control panel is the heart of your security
system to which all your detection devices
connect.
Each Zone of the panel can be connected to
one or more detection devices to protect
separate rooms of your premises.
Detection devices may be connected to the
ET8 control system directly by cabling or with
optional wireless (Radio) devices.
Detection devices called Passive Infra-Red
Detectors (or P.I.R’s for short) can detect the
movement of an intruder by sensing their body
heat. P.I.R’s are used to cover various critical
areas of your premises where an intruder may
enter or trespass. Another detection device used
is called a Reed Switch. Reed Switches are
attached to windows and doors to detect if a
window or door has been opened. A Reed
Switch consists of a magnet which is normally
attached to the moving part of a window or door
and the Reed switch which mounts to the door
or window frame.
The panel is “Armed” when it is set to detect an
intruder. At other times it is “Disarmed”.
Normally a zone is considered Sealed.
Activation of a detection device will cause the
zone to be Unsealed and may cause an alarm.
Detectors such as fire detectors and panic
buttons must be able to generate an alarm at all
times regardless of the panel setting. A zone
with this assignment is called a 24 hour zone.
Some detection devices may be required to
generate an alarm or warning only when the
panel is Disarmed. A zone with this assignment
is called a Day zone.
Before leaving the premises you must Arm the
panel to enable it to detect intruders and
generate an alarm. After arming, the panel will
ignore detectors during the Exit Delay Time to
enable you to depart without triggering an alarm.
Arming the system may be done through the
keypad or with the use of optional Radio Keys
for Arming by remote control from outside the
premises.
When you enter the premises the panel will
ignore selected zones for the Entry Delay Time
and will not alarm unless you don’t Disarm the
panel during this allowed time.
Disarming the system may be done by keypad
or with the use of optional Radio Keys.
Monitor mode allows you to Arm selected zones
while others are ignored. Typically, perimeter
zones (doors and windows) can be monitored
while you are at home.
If you wish to split your alarm system into two
areas with access limited to each area by code
numbers then Area operation is used. Radio
Keys can also Arm and Disarm Areas.
The control panel housing and the covers over
external sirens are protected by tamper
switches to detect someone attempting to
disable the security system. Activation of these
switches will cause an instant tamper alarm.
If a detector becomes faulty, you can Exclude
the associated zone so that it is totally ignored
and cannot generate an alarm. Including the
zone will enable it to generate an alarm again.
The control panel is fitted with a rechargeable
stand-by battery to ensure your security system
continues to operate if the mains power is
interrupted. This control panel automatically
tests the battery every hour and whenever you
Arm/Disarm the panel. (Dynamic Battery test).
Whenever an alarm occurs, it may be silenced
with a User Code or by optional Radio Keys,
otherwise it will reset at the end of Alarm Reset
Time.
All alarms are stored in memory and may be
viewed at any time by entering Memory Mode.

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL
6
KEYPAD
The ET8 control panel may be supplied with either the LED keypad (100-192) or the E-Tech LCD
Keypad (100-667).
The keypad provides important visual and audible indications and is the main interface for operating
and programming the ET8 control panel.
2
5
8
0
1
4
7
P
3
6
9
E
ARM
MONITOR
EXCLUDE
MEMORY
Not Ready
Backlit LCD
icon display
PANIC buttons
PANIC buttons
“Not Ready”light
The “Not Ready” light is on when the panel is not ready to Arm.
i.e, a zone is unsealed, there may still be movement in the
premises or a door or window left open
ARM button
ARM button MONITOR button
MONITOR button EXCLUDE button
EXCLUDE button
PROGRAM button
ENTER button
MEMORY button
MEMORY button
LED KEYPAD LCD KEYPAD
PROGRAM button
Protective flap not shown
Protective flap not shown
ENTER button
PANIC
ARM
1
4
7
0
2
5
8
ENTER
3
6
9
MONITOR
EXCLUDE
PROGRAM
PANICMEMORY
105mm 90mm
150mm
135mm
DISPLAY TEST (LCD Keypad only)
To display all the keypad icons press and hold
the button for at least 2 seconds. All the
icons will be on whilst the button is held
down.
Display Test can be activated at any time either
in operating mode or any program mode.

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL 7
KEYPAD INDICATORS
Zone is sealed
Zone is unsealed, or Power fault
or System is Armed,
or phone line fault
Disarmed
Disarmed
Disarmed
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Ready to Arm
Zone is unsealed
Ready to Arm
Armed (AREA 1)
Armed (AREA 2)
Monitor Mode
Memory Mode selected
Receiving radio signal
Dialler is on line
(And in Memory Mode indicates a
low battery alarm from a radio device)
Indicates that a Radio Key or
other radio device has a
low battery
Phone line fault or
failure to communicate
User Program Mode
Not ready to Arm
Zone alarm
Monitor Mode
(
LED Keypad only)
Mains Power is off
The panel’s backup
battery is low
New alarms in memory
Zones are excluded
Tamper alarm
Installer Program Mode
ZONES 1~8
ARMED
ARM2
MAINS
BATTERY
MEMORY
EXCLUDE
TAMPER
PROGRAM
LINE
READY
RADIO
Not Ready
OFF ON FLASHING
STATUS
LED KEYPAD LCD KEYPAD
1 beep
3 beeps
1 long beep
10 beeps
10
Each key press
Valid command
Error
Mains Power is off
or
Panel Battery is low
KEYPAD BEEPER SOUNDS

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL
8
OPERATION
This section describes the operation of a
typical control panel installation. Keep in
mind that your installation may vary
depending on the selected options and
equipment. The operating instructions which
follow will cover the most common options.
Consult your installation company if you
require further information.
All control panel operations are controlled by
the ET8 LED or LCD keypad except if an
optional key switch or radio control equipment
is installed.
OPERATING RULES
Generally, the panel will be Disarmed. Armed
or Monitor modes provide different levels of
security for your premises when you are home
or away. Three other temporary modes;
Program, Memory and Exclude, allow you to
perform various operations. The panel will
automatically exit from these temporary modes
if you do not press any buttons on the keypad
in a 4 minute period.
If you make a mistake while entering any codes,
press the Enter or E button and start again.
When you are required to enter your access
code, you are given five opportunities to enter it
correctly. After the fifth invalid attempt the alarm
is activated (requiring the correct code to silence
the alarm). This prevents anyone trying to guess
your code by entering random numbers.
AREA OPERATION
Area Partitioning allows the 8 zones to be split
into two partitions; Area1 and Area2.
The panel then effectively operates as two
separate systems sharing only the siren outputs
and dialler.
USER CODE ASSIGNMENT
A User Code assigned to an Area can Arm and
Disarm only that Area. User Codes assigned to
both Areas will operate both Areas
simultaneously.
COMMON AREA ZONES
Zones assigned to both Areas are Armed only
when Area1 and Area2 are both Armed. This
allows the Common Area zone/s to be shared
by both Areas.
For example, Office A and Office B operate as
separate areas but the entrance foyer used by
both offices is assigned to both areas meaning
it will automatically Arm when both Areas have
Armed. The Common Area then automatically
disarms when either Area1 or Area2 Disarms.
OPERATION
Arming and Disarming is carried out as normal
from a single keypad or separate keypads
installed in both areas or by Radio Key.
Area operation only applies to zones when they
are in the Armed state. This means that Day,
24hr and Monitor zones are independent of the
area operations.
Note: Area partitioning is in addition to Monitor
Mode. Any zone may be allocated to any area.

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL 9
OPERATION
The control panel must be Armed prior to
vacating the premises in order to detect
intruders. Ensure that the panel is not in
Program, Memory or Exclude modes.
Note:If the panel is already in alarm, you must first
silence the alarm before you can Arm.
If something is wrong when Arming the control
panel, the normal 3 beeps will be replaced by
other warnings.
10
10 beeps means Mains Power is
turned off or the Backup Battery is low.
One long beep indicates an invalid
entry or an alarm is outstanding and needs to
be reset by entering your User Code first.
SIREN WARNING:
At the end of the exit time, all zones should be
Sealed. If any are Unsealed, the siren will sound
for 2 seconds as a warning to indicate that those
zones have been automatically excluded. For
maximum security, you should return, Disarm,
check the premises and then Arm again.
Continual warnings could mean that a detector
is faulty and may have to be manually excluded.
If the auto-exclude option is disabled, the siren
will sound for the duration of reset time if a zone
is Unsealed at the end of exit time.
or...
[User Code]
ARM
ARM
ENTER
ENTER
or...
The light must be offNot ReadyThe light must be onReady
Press...Press...
The Armed light will turn on
•Leave the premises within the Exit Delay Time
•3 beeps will sound at the end of Exit Delay Time
The icon will turn on
•Leave the premises within the Exit Delay Time
•3 beeps will sound at the end of Exit Delay Time
[User Code]
LED KEYPAD
ARMING
LCD KEYPAD

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL
10
When you enter the protected premises through
a delay zone, the keypad responds with regular
beeps* as a reminder to Disarm. You then have
your programmed entry delay time to Disarm
the panel by entering one of your user codes. If
the panel is not Disarmed by the end of the entry
delay time, an alarm will occur.
By using the optional radio keys you may
Disarm your system from within your premises
or from outside your entrance door. There is also
the option to ‘Chirp’the outside siren three times
and to flash the strobe light for two seconds as
an indication that you have Disarmed your
system.
If you make a mistake in entering your code,
then you must press enter and start again. Five
incorrect entries will cause an alarm.
* If Entry Beeps are programmed on.
OPERATION
Your panel can be reset and the alarm silenced
by the same key sequence as Disarming the
panel.
If you arrive at your premises and find the strobe
light flashing (if installed), reset the panel as
above. To check the cause of the alarm, you
can view the alarms in memory by entering
Memory Mode.
[User Code] [User Code]
ENTER
Enter the premises through a delay zoneEnter the premises through a delay zone
Press...Press...
The Armed light will turn off The icon will turn off
LED KEYPAD
DISARMING
LCD KEYPAD
RESETTING ALARMS
Alarms may be caused by:
•A zone has been triggered while Armed
•A Tamper has been triggered
•A PANIC button has been triggered
All of these may cause your sirens and strobe
to operate. Various visual indications relevant
to the alarm will be retained in the memory. If
this occurs, Disarming your control panel will
reset the alarm. The cause of the alarm can be
identified by entering the Alarm Memory Mode
as described on page 15.
ALARMS, DEFINITION

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL 11
OPERATION
Monitor mode allows you to Arm selected zones
while others are ignored. Typically, perimeter
zones (doors and windows) can be monitored
while you are at home.
Your installer must program which zones will be
active in Monitor mode.
The panel must be fully Disarmed before Arming
in Monitor Mode.
If an alarm occurs while in Monitor mode,
entering
[User Code]
will silence the alarm.
This will also Disarm the panel, so remember to
enter monitor again if needed.
By using the optional Radio Keys you can enter
Monitor Mode by pressing the OFF button twice
within 4 seconds. (Your installer must enable
Radio Key Monitor Arming for this to work).
or...
[User Code]
ENTER
ENTER
or...
Press...Press...
The Monitor light will turn on
•Only the zones which have been programmed
by your installer as Monitor zones will be Armed
•Only the zones which have been programmed
by your installer as Monitor zones will be Armed
The MONITOR icon will turn on
[User Code]
MONITOR
MONITOR
LED KEYPAD
MONITOR MODE
LCD KEYPAD

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL
12
The keypad PANIC function may have been
programmed to be either AUDIBLE - activates
siren or buzzers, or SILENT - If your system is
monitored by a Central Station, sends a PANIC
report by dialler. (If PANIC reports have been
enabled by your installer).
OPERATION
PANIC cannot be used while the panel is in
Program, Memory or Exclude mode.
Note: Your installer may have installed a separate
PANIC button. To activate the panic alarm simply
press that button.
Press...Press...
or...
or...
Both keys together
(If Keypad Panic Shortcut has been enabled by your installer) (If Keypad Panic Shortcut has been enabled by your installer)
[User Code]
PANIC
PANIC
PANIC
PANIC
ENTER
ENTER
Both keys together
or...
or...
[User Code]
LED KEYPAD
KEYPAD PANIC
LCD KEYPAD
A DURESS alarm can be triggered to alert the
Central Station that you are being forced to
Disarm the panel against your will.
To Disarm and send a DURESS alarm, prefix
your User Code with one of the digits 5, 6, 8 or
9 when Disarming.
DURESS alarms are only used if your system is
monitored by a Central Station.
DURESS IS NORMALLY NOT ENABLED. TO
ENABLE THE DURESS FUNCTION, CONSULT
YOUR INSTALLER
2. If Duress Alarm Report has been enabled by your installer 2. If Duress Alarm Report has been enabled by your installer
1. If your system is monitored by a central monitoring station 1. If your system is monitored by a central monitoring station
1. By default, Duress Alarm does not sound the RESET output 1. By default, Duress Alarm does not sound the RESET output
Disarms and sends a Duress Alarm report by dialler. Disarms and sends a Duress Alarm report by dialler.
Duress Alarm can be programmed to sound
the RESET output.
Digits 5, 6 & 8 in front of the user code can also
be used trigger the Duress alarm Digits 5, 6 & 8 in front of the user code can also
be used trigger the Duress alarm
Duress Alarm can be programmed to sound
the RESET output.
Press... Press...
9
[User Code] [User Code]
LED KEYPAD
KEYPAD DURESS ALARM
LCD KEYPAD

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL 13
1. If Keypad Fire Alarm has been enabled by your installer 1. If Keypad Fire Alarm has been enabled by your installer
2. If Fire Alarm Report has been enabled by your installer 2. If Fire Alarm Report has been enabled by your installer
1. If your system is monitored by a central monitoring station 1. If your system is monitored by a central monitoring station
Sounds the siren (Fire Alarm siren sound) Sounds the siren (Fire Alarm siren sound)
Sends a Fire Alarm report by dialler. Sends a Fire Alarm report by dialler.
Press... Press...
LED KEYPAD
KEYPAD FIRE ALARM
LCD KEYPAD
2. If Medical Alarm Report has been enabled by your installer 2. If Medical Alarm Report has been enabled by your installer
1. If your system is monitored by a central monitoring station 1. If your system is monitored by a central monitoring station
Sends a Medical Alarm report by dialler. Sends a Medical Alarm report by dialler.
Press... Press...
Medical Alarm does not sound sirens. Medical Alarm does not sound sirens.
LED KEYPAD
KEYPAD MEDICAL ALARM
LCD KEYPAD
OPERATION

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL
14
OPERATION
If a detector becomes faulty and cannot be
Sealed when arming the panel, then its zone
may be Excluded so that it does not generate
alarms.
When zones have been Excluded, the EXCLUDE
light flashes continuously while the panel is
Disarmed and also when Armed.
Zones can only be Excluded when the panel is
Disarmed.
Zone Exclude IS not permanent. Excluded
zones are automatically INCLUDED next time the
panel is Disarmed.
Zones can be manually included by the same
method as Excluding. Simply use the
[ZONE NUMBER] sequence to turn OFF the
zone lights to be Included.
The zone light of each Excluded zone will turn on The zone light of each Excluded zone will turn on
or... [User Code]
[Zone No.] [Zone No.][Zone No.] [Zone No.]
ENTER
ENTER
ENTER
ENTER
ENTER
or...
Press...Press...
Press... Press...
The
The The
Enter the zone number of the zone/s to be Excluded
to exit Exclude mode to exit Exclude mode
Enter the zone number of the zone/s to be Excluded
Exclude light will turn on
Exclude light will flash continuously
The EXCLUDE icon will turn on
EXCLUDE icon will flash continuously
[User Code]
LED KEYPAD
EXCLUDING ZONES
LCD KEYPAD
NOTES
•EXCLUDE E works only when the panel is Disarmed.
•EXCLUDE [User Code] E works in any state.
•EXCLUDE [User Code] E can only exclude the zones in the Area assigned to that code.

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL 15
OPERATION
The ET8 Control Panel stores a comprehensive
Alarm Memory, including Arming, Disarming,
Low Battery, Mains Fail and Alarm events.
The memory is constantly upgraded and the last
30 events are always available for viewing.
This Memory display can only be selected while
the panel is in the Disarmed state.
TO CLEAR THE MEMORY LIGHT
The MEMORY light flashes continuously when
an alarm has occurred as a reminder to view
the alarm memory.
The MEMORY light stops flashing after the
memory is viewed as shown above.
The MEMORY light is automatically cleared
next time the panel is Armed.
MEMORY MODE - EVENTS INDICATED BY KEYPAD LIGHTS:
LIGHT ALARM EVENT
Zone lights 1~8 Zone alarm
ARM Panel Armed
(no lights) Panel Disarmed
TAMPER Tamper alarm (Siren cover, panel etc)
EXCLUDE Panic alarm
BATTERY Low Battery
MAINS Mains power failure
RADIO, BATTERY, ZONE Radio Device battery low
RADIO, BATTERY, ARM Radio Key battery low
The most recent event will be displayed The most recent event will be displayed
The next most recent event will be displayed The next most recent event will be displayed
...and so on (up to 30 events) ...and so on (up to 30 events)
or... or...
[User Code] [User Code]
ENTER
ENTER
ENTER
Press... Press...
Press... Press...
Press... Press...
Press... Press...
Press... Press...
The The
to exit Memory mode to exit Memory mode
Memory light will turn on MEMORY icon will turn on
LED KEYPAD
VIEWING EVENT MEMORY
LCD KEYPAD

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL
16
RADIO KEY OPERATION
E-TECH RADIO KEY 3 BUTTON
The optional E-Tech Radio Key allows you to Arm, Disarm and
activate PANIC. The Radio Key can also Arm Monitor Mode, (if this
has been enabled by your installer).
ARMING
Press the ON button.
• The keypad will give 3 beeps.
• The outside siren will give 1 ‘chirp’. (If enabled by your installer)
• The strobe light will flash briefly
DISARMING
Press the OFF button.
• The keypad will give 3 beeps.
• The outside siren will give 3 ‘chirps’. (If enabled by your installer).
• The strobe light will flash briefly.
ARMING MONITOR MODE
Press the OFF button twice within 4 seconds.
• The keypad will give 9 beeps.
• The outside siren will NOT ‘chirp’.
• The strobe light will flash briefly.
PANIC
Press and hold the PANIC button for at least 4 seconds.
• The siren and strobe will activate, (If enabled by your installer)
• The dialler will report a Panic alarm, (If enabled by your installer
and if your system is monitored by a central station).
Press the OFF button to reset a Panic alarm
* The E-Tech Radio Key is optional and is not supplied with any E-Tech control panels as standard
* E-Tech radio products require a E-Tech Radio Interface (100-200) to be fitted to the control panel.

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL 17
OPTION OPTION No PROGRAMMEDRANGE
FACTORY
DEFAULT
User Code 1 (Master Code) P11E 123 3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
1 to 99 sec
10 to 990 sec
1 to 99 sec
Up to 15 digits
User Code 2 P12E
User Code 3 P13E
User Code 4 P14E
User Code 5 P15E
User Code 6 P16E
User Code 7 P17E
User Code 8 P18E
User Code 9 P19E
User Code 10 P20E
User Code 11 P21E
User Code 12 P22E
User Code 13 P23E
User Code 14 P24E
User Code 15 P25E
Entry Delay 1
Entry Delay 2
Exit Delay
Follow Me Telephone No.
P26E
P27E
P28E
P00E
20 seconds
60 seconds
60 seconds
NOTE: The Entry Delay 2 timer programs in 10 second intervals.
Example: if a value of 6 is programmed, the time is 60 seconds.
PROGRAMMING OPTIONS TABLE
PROGRAMMING
Various system options, as listed below, can
be programmed by the user. These options
can only be accessed from Program Mode.
User Codes may need to be re-programmed
if a person has forgotten their code, to give a
new user access to the system or to give
someone temporary access.
User Codes 2-15 can be set as Arm Only
Codes. These codes can Arm but cannot
Disarm the panel. (Useful for assigning to
cleaners, tradesmen etc.)
You may need to change the Entry and Exit
timers if you find the delays are too long or
short.
If Audible Monitoring is programmed by your
installer, the ‘Follow Me’Telephone Number is
the telephone number the dialler will call in the
event of an alarm.
If your E-Tech ET8 panel is monitored by a
Central Station, the Follow Me number is
ignored.
For all other programming changes, talk to
your installer.
The panel will automatically exit Program
Mode is no buttons are pressed within a 4
minute period.
FACTORY DEFAULT MASTER CODE IS: 123

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL
18
PROGRAMMING
Enters Program Mode. The PROGRAM light will be on. Enters Program Mode. The PROGRAM light will be on.
The two digit option number for the code to be programmed.
The existing code (if any) will be displayed. The existing code (if any) will be displayed.
The two digit option number for the code to be programmed.
To exit Program Mode
The panel must be in Program Mode. (Program light ON)
When an is displayed, the ARM light or icon is displayed, followed by the digits of the codeArm Only code
To exit Program Mode
Enter the new code twice. The new code will be displayed.
Enter the new code twice. The new code will be displayed.
[Master Code] [Master Code]
[Option No.] [Option No.]
[NEW CODE] [NEW CODE] [NEW CODE]
[NEW CODE]
ENTER
ENTER
ENTER
ENTER
ENTER
Press... Press...
Press... Press...
Press...
To program User Code 1 (The Master Code) to be 1234:
To program User Code 2 as an ARM ONLY code to be 5678:
Press...
Press... Press...
P12E ARM E E E5678 5678
P11E E E1234 1234
EXAMPLES
LED KEYPAD
PROGRAMMING USER CODES
LCD KEYPAD
Enters Program Mode. The PROGRAM light will be on. Enters Program Mode. The PROGRAM light will be on.
The existing time will be displayed.
The new time will be displayed.
The existing time will be displayed.
The new time will be displayed.
To exit Program Mode To exit Program Mode
The panel must be in Program Mode. (Program light ON)
[Master Code] [Master Code]
[Option No.*] [Option No.*]
[NEW TIME] [NEW TIME]
ENTER
ENTER
ENTER
ENTER
Press... Press...
Press... Press...
Press... Press...
To program Entry Delay Time1 to be 15 seconds:
To program Exit Delay Time to be 40 seconds:
Press... Press...
P28E E40
P26E E15
EXAMPLES
LED KEYPAD
PROGRAMMING TIMERS
LCD KEYPAD

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL 19
PROGRAMMING
Enters Program Mode. The PROGRAM light will be on. Enters Program Mode. The PROGRAM light will be on.
The existing telephone number (if any) will be displayed. The existing telephone number (if any) will be displayed.
The new telephone number will be displayed. The new telephone number will be displayed.
To exit Program Mode To exit Program Mode
The panel must be in Program Mode. (Program light ON)
[Master Code]
[Option No.*]
[NEW TELEPHONE NUMBER] [NEW TELEPHONE NUMBER]
ENTER
ENTER
ENTER
ENTER
Press... Press...
Press... Press...
Press... Press...
To program the Follow Me Telephone Number to be 9123 1234:
To the Follow Me Telephone Number:DELETE
Press... Press...
[Master Code]
[Option No.*]
P00E E912341234
P00E MEMORY E
EXAMPLES
LED KEYPAD
PROGRAMMING THE FOLLOW-ME TELEPHONE NUMBER
LCD KEYPAD
* For a list of option numbers, see the Programming Options Table on page 17
[Master Code]
[Master Code]
ENTER
To enter PROGRAM MODE
ENTER
To exit PROGRAM MODE

E-TECH ET8 V4 CONTROL PANEL - USER MANUAL
20
MONITORING
CENTRAL STATION MONITORING
The ET8 control panel has an on-board digital
dialler which can send detailed alarm messages
to a Central Monitoring Station.
The digital messages can include information
about the zone or zones which caused the
alarm, tamper alarms, low battery or mains
failure reports, and it can also (by user number)
identify the users who Arm and Disarm the
system.
Central Station Monitoring is highly
recommended and is the most effective method
of monitoring your ET8 alarm system. For
further information about 24 hour monitoring,
contact your installer or E-Tech Security
Products.
MONITORED PREMISES
CENTRAL STATION MONITORING
TELEPHONE LINE MONITORING STATION
Table of contents