Eaton COOPER POWER SERIES User manual

600 A 15 kV class PUSH-OP™
insulated adapter cap
General
Eaton's Cooper Power™ series 600 A, 15 kV Class
PUSH-OP™ adapter cap is a factory assembled
LRTP and T-body with a stainless steel shroud
and tin-plated copper probe. It meets all the
requirements of IEEE Std 386™-2006 standard,
Separable Connector Systems.
The PUSH-OP adapter cap has a non-bolted
connection that eliminates any need for threading
and its associated problems.
The device is used to cap a 600 A PUSH-OP type
bushing tap interface with the 200 A loadbreak
interface allowing for live testing and visible
grounding. The 200 A tap is three-phase switching
and three-phase fault close rated. Used with a
200A insulated protective cap, Eaton's Cooper
Power series M.O.V.E. arrester or grounding
elbow, a PUSH-OP adapter cap provides a fully
shielded, submersible unit.
Installation
The PUSH-OP adapter cap is installed on a
de-energized 600 A special PUSH-OP bushing
interface using a clampstick. Refer to Service
Information S600-19-1 600 A 15, 25, and 35 kV
Class PUSH-OP Bushing Adapter Cap Installation
Instructions for details. Installation of the factory
assembled LRTP and T-body to the 600 A
PUSH-OP bushing requires no threading.
Production tests
Tests are conducted in accordance with IEEE Std
386™-2006 standard.
• ac 60 Hz 1 Minute Withstand
• 34 kV
• Minimum Corona Voltage Level
• 11 kV
Tests are conducted in accordance with Eaton
requirements.
• Physical Inspection
• Periodic Dissection
• Periodic Fluoroscopic Analysis
Deadbreak Connector
Catalog Data
CA650019EN Effective April 2015
Supersedes 600-19 January 1990
COOPER POWER
SERIES
Figure 1. Cutaway illustration shows design detail and dimensions.
ote:N Dimensions given are for reference only.
600 A
PUSH-OP
BUSHING
LOCATING PINS
CATCH ASSEMBLY
prevents unit from falling
off of PUSH-OP mating
apparatus upon removal.
SHOTGUN
STICK EYE
GROUNDING TAB
Grounding tab provides a convenient
point to connect ground wire to
ensure grounding of the connector
shield.
COPPER PROBE
Field Replaceable Tin Plated
Copper Probe ensures
reliable electrical
connection.
EPDM INSULATION
High quality peroxide cured EPDM
Insulation is mixed and formulated
in-house for complete control of raw
rubber characteristics.
COMPRESSION
CONNECTOR 11/16 Inch
Unthreaded CopperTop
Compression Connector is
sized to ensure a cool
running connector with
maximum current transfer.
GROUNDING LEAD
48 Inch #14 Stranded Plated
Copper Ground Lead ensures
deadfront construction and
avoids low energy discharge
from the molded semi-
conducting shields.
SERIES 300 SHROUD
Stainless Steel Shroud
provides hotstick pulling
eye and locating pins for
PUSH-OP type bushing.
200 A INTERFACE
LOADBREAK
REDUCING
TAP PLUG
SEMI-CONDUCTING
SHIELD
Molded Semi-Conducting
EPDM Shield meets the
requirements of IEEE Std
592™-2007 standard.
DELRIN PLUG
12.8 "
(326 mm)
14.05 "
(358 mm)
Table 1. Voltage Ratings and Characteristics
Description kV
Standard Voltage Class 15
Maximum Rating Phase-to-Phase (LRTP 200 A interface only) 14.4
Maximum Rating Phase-to-Ground 8.3
ac 60 Hz 1 Minute Withstand 34
dc 15 Minute Withstand 53
BIL and Full Wave Crest 95
Minimum Corona Voltage Level 11
Table 2. Current Ratings and Characteristics
Description Amperes
200 A Interface*
Continuous 200 A rms
Switching 10 operations at 200 A rms at 14.4 kV
Fault Closure 10,000 A rms symmetrical at 14.4 kV after 10 switching
operations for 0.17 s
Short Time 10,000 A rms symmetrical for 0.17 s
3,500 A rms symmetrical for 3.0 s
Voltage ratings and characteristics are in accordance with IEEE Std 386™-2006 standard.
Current ratings and characteristics are in accordance with IEEE Std 386™-2006 standard.
* If available system fault current exceeds 10 kA, current limiting fusing must be used upstream,
otherwise fault close and short time ratings of the 200 A interface will be exceeded.
2
Catalog Data CA650019EN
Effective April 2015
600 A 15 kV class PUSH-OP insulated adapter cap
www.eaton.com/cooperpowerseries
Ordering information
To order a 15 kV Class PUSH-OP Insulated Adapter Cap Kit, refer to
Table 3.
Each kit contains:
• Assembled Adapter Cap
• Shipping Cap (not for energized operation)
• Silicone Lubricant
• Installation Instruction Sheet
Table 4. Replacement Parts
Description Catalog Number
Loadbreak Reducing Tap Plug (includes STUD-T) LRTP615
Probe 2638198B01B
Extended Length Stud STUD-T
Catch Assembly 2638191B01
Shipping Cap (for 200 A interface) 2637123B01
Table 3. Insulated Adapter Cap Kits
Description Catalog Number
Adapter Cap PDBA615
Adapter Cap with 200 A Insulated Protective Cap PDBA615C
3
Catalog Data CA650019EN
Effective April 2015
600 A 15 kV class PUSH-OP insulated adapter cap
www.eaton.com/cooperpowerseries
Eaton and Cooper Power are valuable
trademarks of Eaton in the U.S. and other
countries. You are not permitted to use these
trademarks without the prior written consent
of Eaton.
IEEE Std 386™-2006 standard is a trademark
of the Institute of Electrical and Electronics
Engineers, Inc., (IEEE). This publication/
product is not endorsed or approved by the
IEEE.
600 A 15 kV class PUSH-OP insulated adapter capCatalog Data CA650019EN
Effective April 2015
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Power Systems Division
2300 Badger Drive
Waukesha, WI 53188
United States
Eaton.com/cooperpowerseries
© 2015 Eaton
All Rights Reserved
Printed in USA
Publication No. CA650019EN
For Eaton's Cooper Power series PUSH-OP
deadbreak connector product information
call 1-877-277-4636 or visit:
www.eaton.com/cooperpowerseries.

Other manuals for COOPER POWER SERIES

75

This manual suits for next models

1

Other Eaton Cables And Connectors manuals

Eaton Crouse-Hinds ARKTITE CPP Series Setup guide

Eaton

Eaton Crouse-Hinds ARKTITE CPP Series Setup guide

Eaton DMM-125 SE4 Series Manual

Eaton

Eaton DMM-125 SE4 Series Manual

Eaton Crouse-Hinds ARK-GARD M97 Series Setup guide

Eaton

Eaton Crouse-Hinds ARK-GARD M97 Series Setup guide

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton HotSwap MBP - 115 User manual

Eaton

Eaton HotSwap MBP - 115 User manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton EZ II Series User manual

Eaton

Eaton EZ II Series User manual

Eaton NZM2-4-XKA Manual

Eaton

Eaton NZM2-4-XKA Manual

Eaton DX-SPL-RJ45-3SL Manual

Eaton

Eaton DX-SPL-RJ45-3SL Manual

Eaton EU4A-RJ45-CAB2 Manual

Eaton

Eaton EU4A-RJ45-CAB2 Manual

Eaton Moeller SmartWire-Darwin Series User manual

Eaton

Eaton Moeller SmartWire-Darwin Series User manual

Eaton Roughneck IF 1683 Setup guide

Eaton

Eaton Roughneck IF 1683 Setup guide

Eaton DMVS-160 SE5 Series Manual

Eaton

Eaton DMVS-160 SE5 Series Manual

Eaton EU4A-RJ45-CAB2 Manual

Eaton

Eaton EU4A-RJ45-CAB2 Manual

Eaton 600 A 15 kV class T-OP II Programming manual

Eaton

Eaton 600 A 15 kV class T-OP II Programming manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton Crouse-Hinds Ark-Gard ENR Series Setup guide

Eaton

Eaton Crouse-Hinds Ark-Gard ENR Series Setup guide

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton Crouse-Hinds GRUE Series Setup guide

Eaton

Eaton Crouse-Hinds GRUE Series Setup guide

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton NZM1 Series Manual

Eaton

Eaton NZM1 Series Manual

Eaton ZADEL-16 Manual

Eaton

Eaton ZADEL-16 Manual

Eaton Crouse-hinds series Setup guide

Eaton

Eaton Crouse-hinds series Setup guide

Popular Cables And Connectors manuals by other brands

Vicon V4400QS-1 Installation & operation manual

Vicon

Vicon V4400QS-1 Installation & operation manual

LedSpot P2-NF Series instructions

LedSpot

LedSpot P2-NF Series instructions

Hubbell INSULGRIP HBL3200RS2W manual

Hubbell

Hubbell INSULGRIP HBL3200RS2W manual

Denon AK-HM500/300/100 Specifications

Denon

Denon AK-HM500/300/100 Specifications

geratech EGE-SP118-4K manual

geratech

geratech EGE-SP118-4K manual

volkano Smart Series instruction manual

volkano

volkano Smart Series instruction manual

Netio PowerCable 101 Series manual

Netio

Netio PowerCable 101 Series manual

gofanco DPMST2HDMI user guide

gofanco

gofanco DPMST2HDMI user guide

Audio Technica ATW-49CB quick start guide

Audio Technica

Audio Technica ATW-49CB quick start guide

Eminent AB7812 user manual

Eminent

Eminent AB7812 user manual

EINHELL HSP 6/104 operating instructions

EINHELL

EINHELL HSP 6/104 operating instructions

Philips SDW5204W Specifications

Philips

Philips SDW5204W Specifications

NEUTRIK powerCON TRUE1 TOP NAC3FX-W-TOP Application Instruction

NEUTRIK

NEUTRIK powerCON TRUE1 TOP NAC3FX-W-TOP Application Instruction

Siemens 3RK1911-2B 0 Series operating instructions

Siemens

Siemens 3RK1911-2B 0 Series operating instructions

enphase QD-CONN-10F Quick install guide

enphase

enphase QD-CONN-10F Quick install guide

Baaske Medical MI 1005 user manual

Baaske Medical

Baaske Medical MI 1005 user manual

METALSUB KL1256 manual

METALSUB

METALSUB KL1256 manual

Gleason Reel Direct Drive Electric Cable Reels S-18 Installation and maintenance instructions

Gleason Reel

Gleason Reel Direct Drive Electric Cable Reels S-18 Installation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.