manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Eaton
  6. •
  7. Cables And Connectors
  8. •
  9. Eaton NZM2-4-XKA Manual

Eaton NZM2-4-XKA Manual

This manual suits for next models

8

Other Eaton Cables And Connectors manuals

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton DMM-125 SE4 Series Manual

Eaton

Eaton DMM-125 SE4 Series Manual

Eaton ZB4-209-DS2 Manual

Eaton

Eaton ZB4-209-DS2 Manual

Eaton 200 A 25 kV class User manual

Eaton

Eaton 200 A 25 kV class User manual

Eaton 200 A 15 kV class User manual

Eaton

Eaton 200 A 15 kV class User manual

Eaton 200 A 15 kV class User manual

Eaton

Eaton 200 A 15 kV class User manual

Eaton 600 A 35 kV Class Insulated Standoff Bushing User manual

Eaton

Eaton 600 A 35 kV Class Insulated Standoff Bushing User manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton COOPER POWER SERIES Programming manual

Eaton

Eaton COOPER POWER SERIES Programming manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton EM4PBLSC User manual

Eaton

Eaton EM4PBLSC User manual

Eaton 600 A 35 kV Class Insulated Standoff Bushing User manual

Eaton

Eaton 600 A 35 kV Class Insulated Standoff Bushing User manual

Eaton COOPER POWER SERIES User manual

Eaton

Eaton COOPER POWER SERIES User manual

Eaton Roughneck IF 1683 Setup guide

Eaton

Eaton Roughneck IF 1683 Setup guide

Eaton DX-SPL-RJ45-3SL Manual

Eaton

Eaton DX-SPL-RJ45-3SL Manual

Eaton MSC-R Series Manual

Eaton

Eaton MSC-R Series Manual

Eaton NZM1 Series Manual

Eaton

Eaton NZM1 Series Manual

Eaton RMQ-Titan C22-PV Series User manual

Eaton

Eaton RMQ-Titan C22-PV Series User manual

Popular Cables And Connectors manuals by other brands

StarTech.com ST124HD20 quick start guide

StarTech.com

StarTech.com ST124HD20 quick start guide

Philips SWV4543S/10 Features

Philips

Philips SWV4543S/10 Features

Larson Electronics 10-50C instruction manual

Larson Electronics

Larson Electronics 10-50C instruction manual

Grip MEK-PM Assembly and operating manual

Grip

Grip MEK-PM Assembly and operating manual

Ultra Products Travel Pack #3 ULT31436 Specifications

Ultra Products

Ultra Products Travel Pack #3 ULT31436 Specifications

Surpass QCH-F Operation manual

Surpass

Surpass QCH-F Operation manual

Philips SWA6310 Specifications

Philips

Philips SWA6310 Specifications

StarTech.com CRJ4550PK quick start guide

StarTech.com

StarTech.com CRJ4550PK quick start guide

Nohau EMUL-IP2K-PC user guide

Nohau

Nohau EMUL-IP2K-PC user guide

Foxun SX-SP144E-HD4K2K operating instructions

Foxun

Foxun SX-SP144E-HD4K2K operating instructions

Philips SWA3305W Specifications

Philips

Philips SWA3305W Specifications

opticis Stretch DVIM1-1P0x user manual

opticis

opticis Stretch DVIM1-1P0x user manual

Volkswagen VAS 6558A operating manual

Volkswagen

Volkswagen VAS 6558A operating manual

NEXIBO N-13 user manual

NEXIBO

NEXIBO N-13 user manual

CYP PU-1H3HBTL Operation manual

CYP

CYP PU-1H3HBTL Operation manual

Allen-Bradley 1784-u2dhp installation instructions

Allen-Bradley

Allen-Bradley 1784-u2dhp installation instructions

Global Caché Flex Link Blaster quick start

Global Caché

Global Caché Flex Link Blaster quick start

Hauppauge USB-Live2 Quick installation guide

Hauppauge

Hauppauge USB-Live2 Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Emergency On Call Service: Local representative (http://www.eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en) 1/3
Electric current! Danger to life!
Only skilled or instructed persons may carry out the
following operations.
Lebensgefahr durch elektrischen Strom!
Nur Elektrofachkräfte und elektrotechnisch unterwiesene
Personen dürfen die im Folgenden beschriebenen Arbeiten
ausführen.
Tension électrique dangereuse !
Seules les personnes qualifiées et averties doivent
exécuter les travaux ci-après.
¡Corriente eléctrica! ¡Peligro de muerte!
El trabajo a continuación descrito debe ser realizado por
personas cualificadas y advertidas.
Tensione elettrica: Pericolo di morte!
Solo persone abilitate e qualificate possono eseguire le
operazioni di seguito riportate.
触电危险!
只允许专业人员和受过专业训练的人员进行
下列工作。
Э ! Оа я !
Т   
   щ .
en
de
fr
es
it
zh
ru
Instruction Leaflet
Montageanweisung
Notice d’installation
Instrucciones de montaje
Istruzioni per il montaggio
安装说明
Ия  а
04/16 IL01210007Z
(AWA1230-2050, AWA1230-2652)
NZM2(-4)-XKA
NZM2-1-XKA
NZM3(-4)-XKA1
NZM3-1-XKA1
NZM3(-4)-XKA2
NZM3-1-XKA2
…XKA… Mechanical (Tunnel) Lug Connector Kits for NZM2 and NZM3 Molded Case Circuit-Breakers and Switches
Control circuit terminal
Steuerleitungsanschluss
Borne pour conducteur de commande
Tornillo para cable de mando
Collegamento cavo di comando
Ïðèñîåäèíåíèå ê ëèíèè
óïðàâëåíèÿ
For aluminium (Al) and copper (Cu) connection.
Für Aluminium-(Al) und Kupferanschluss (Cu).
Pour le raccordement aluminium (Al) et cuivre (Cu).
Para conexión de aluminio (Al) y de cobre (Cu).
Per collegamento di alluminio (Al) e rame (Cu).
Äëÿ àëþìèíèåâîãî (Al) è ìåäíîãî ïðèñîåäèíåíèÿ (Cu).
-NA , -CNA
(UL/CSA models)
The barrier (shown shaded in the diagrams) is held
tightly into grooves on top and bottom sides of the
breaker or switch and must be removed in order to
mount …-XKA… Mechanical (Tunnel) lug connectors
on NZM2 and NZM3 Circuit-Breakers and switches.
To remove:
From the back of the device, use thumb pressure to
push, or an appropriate tool to gently tap each side of
the barrier to help slide it out.
NZM2(-4)-XKA = 185 mm2/350 kcmil
NZM2-1-XKA
NZM3(-4)-XKA1 = 185 mm2/350 kcmil
NZM3-1-XKA1
NZM3(-4)-XKA2 = 240 mm2/500 kcmil
NZM3-1-XKA2
Recommended max. conductor
Empfohlener max. Leiter
Section max. recommandée
Conductor máx. recomendado
Conduttore max. raccomandato
Ðåêîìåíäóåìûé ìàêñ. ïðîâîäíèê
Caution!
The removal or exchange of parts during mounting may become necessary.
Refer to installation instructions for proper assembly and to maintain electrical
clearances.
Attenzione!
Per l’esecuzione degli interventi descritti potrebbe essere necessaria la rimozione o
sostituzione di alcuni pezzi. Attenersi alle istruzioni d’installazione per garantire dopo
l’assemblaggio le vie di dispersione necessarie.
Vorsicht!
Für die Durchführung der beschriebenen Arbeiten kann das Entfernen oder
der Austausch von Teilen notwendig sein.
Bitte alle Installations-Anweisungen beachten, um die erforderlichen Luft- und
Kriechstrecken nach dem Zusammenbau zu gewährleisten.
Attention !
L’enlèvement où l’échange de certaines pièces pendant le montage est parfois
nécessaire. Consultez l’instruction d’assemblage pour assurer une installation
conforme aux normes.
Îñòîðîæíî!
Ïðè ïðîâåäåíèè îïèñàííûõ ïðîöåäóð ìîæåò âîçíèêíóòü íåîáõîäèìîñòü äåìîíòèðîâàòü èëè çàìåíèòü
äåòàëè. Äëÿ îáåñïå÷åíèÿ íàäëåæàùèõ çàçîðîâ è âûâîäà òîêà óòå÷êè, ñîáëþäàéòå âñå
èíñòðóêöèè ïî ìîíòàæó.
¡Atención!
Con el fin de llevar a cabo los trabajos descritos, puede ser necesario eliminar
o cambiar alguna pieza. Le rogamos tenga en cuenta todas las instrucciones de
instalación para así garantizar las líneas de fuga y efluvio necesarias tras el montaje.
Cu
1 x 0.75 - 2.5 mm21.2 Nm
2 x 0.75 - 1.5 mm211 lb-in
1 x AWG 18 - 14
2 x AWG 18 - 16
push
en
it
de
zh
fr
ru
es
2/3 Emergency On Call Service: Local representative (http://www.eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en)
04/16 IL01210007Z
NZM2(-4)-XKA
NZM2-1-XKA
*Max. 185 mm² can be connected depending on the
cable manufacturer.
Je nach Kabelhersteller bis zu 185 mm² anschließbar.
Selon le fabricant de câble, possibilité de raccorder
jusqu’à 185 mm².
Dependiendo del fabricante del cable pueden
conectarse hasta 185 mm².
Sezione max collegabile 185 mm² in base al produttore
del cavo.
 çàâèñèìîñòè îò ïðîèçâîäèòåëÿ êàáåëÿ ìîæíî
ïîäêëþ÷àòü äî 185 ìì².
NZM3(-4)-XKA2
NZM3-1-XKA1
NZM3-1-XKA2
1
2
3a
Z 2
8 mm
1
ON
3
1
2
5 mm
14 Nm rNZM2-XKA
(123.9 lb-in)
8 mm
31 Nm rNZM3-XKA1
(274.37 lb-in)
XKSA
f80 mm
f(3.15“)
4a
ON
Z 2
1.2 Nm (10.6 lb-in)
5a
2
1
ON
35 mm
(1.38 ”)
8 mm
31 Nm
(265.5 lb-in)
1 x 16 - 185 mm2 *
1 x AWG 6 - 350 kcmil
95 mm
2
185 mm²
3b
2
1
1b
2 x
1a
8 mm
31 Nm (274.37 lb-in)
f80 mm
f(3.15“)
4b
Z2
1.2 Nm (10.6 lb-in)
Emergency On Call Service: Local representative (http://www.eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en) 3/3
04/16 IL01210007Z
Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Germany
© 2002 by Eaton Industries GmbH, www.eaton.eu/documentation All Rights Reserved
04/16 IL01210007Z 12256584/DE17 Doku
Printed in Germany (04/16)
Use ferrules with flexible and highly flexible conductors.
Bei feindrähtigen und hochflexiblen Leitern Aderendhülsen verwenden.
Pour les conducteurs souples et extra-souples, utiliser des embouts.
Para conductores flexibles y muy flexibles deben utilizarse terminales.
Per conduttori flessibili e altamente flessibili utilizzare capicorda.
对于多股和非常容易弯曲的线缆可以使用线缆衬套
Д      
.
Use of Terminal Cover NZM3-XKSA on UL/CSA models:
– Mechanical (tunnel) lug connector kits …XKA… come supplied with terminal cover NZM3-XKSA.
Top and bottom portions of the terminal cover are mounted as shown in above diagrams and installation is always required.
– Terminal cover NZM3-XKSA maintains electrical clearances and provides protection against accidental contact
with live parts in the incoming and outgoing supply circuit terminations of the Circuit-Breaker or switch
–NZM3-XKA2 Maximum allowed rated current: 400 A
5b
1
2
31 Nm (274.37 lb-in)
35 mm
(1.38 ”)
60 mm
(2.36 ”)
8 mm
1 x 50 - 240 mm2
2 x 50 - 240 mm2
1 x AWG 0 - 500 kcmil
2 x AWG 0 - 500 kcmil
6
Z 2
1 Nm
(8.85 lb-in)
XKSA
XKSA
1
2