
START-S7LT Operating guide
-2-
Premises
Thismanualprovidesallthespecicinformationyou
need to familiarize yourself with and correctly ope-
rate your unit. Read it very carefully when you pur-
chase the instrument and consult it whenever you
have doubts regarding use and before performing
any maintenance operations.
Environmental protection
measures
Information regarding the environment
for customers within the European
Union. European Directive EC 2002/96
requires that units bearing this symbol
on the unit and/or on the packaging be
disposed of separately from undifferenti-
ated urban wastes.
The symbol indicates that the product must not be
disposed of with the ormal household wastes. The
owner is responsible for disposing of this prod-
uct and other electrical and electronic equipment
throughspecicwastecollectionfacilitiesindicated
by the government or local public agencies. Correct
disposal and recycling help prevent any potentially
negative impact on the environment and human
health. To receive more detailed information regard-
ing disposal of your unit, we recommend that you
contact the competent public agencies, them waste
collection service or the shop where you purchased
the product.
Piccol
Small legend
LSO or FCA Open limit switch
LSC or FCC Close limit switch
START control to drive the door AUTO-choice
PARTIAL OP. in sliding units: control partial opening
Vac alternate current
Vdc direct current
NC normally closed
NO normally open
Isolated contact isolated from power supply
Index
Par. Description Page
1 Introduction 3
1.1 Safety precautions
1.2 Symbols and warning
1.3 Type of installation
2 Description of the connections 4
2.1 Product description
2.2 Field of application
2.3 Technical description
3 Premises 5
3.1 Preliminary checks
3.2 Type of electrical wires
3.3 Notes on connections
4 Installation 6
4.1 Scheme of the control unit and electrical connections
4.2 Adjustment of the FORCE, SPEED and SLOWING DOWN
4.3 Description of the electrical connections
4.4 Checking connections
4.5 Connection of the POWER SUPPLY and BATTERY 8
4.6 Connection of the MOTOR
4.7 Connection of the encoder
4.8 CONNECTION OF THE LAMPS
4.9 Connection of the LIGHT 9
4.10 Connection of the electrical lock
4.11 Connection of the STOP
4.12 Connection of the Open and Close limt switches 10
4.13 Connection of the PHOTO A (only closing)
4.14 Connection of the START commands 11
4.15 Connection of the CLOSING / PEDESTRIAN
4.16 Power supply of the accessories
4.17 Connection of the ANTENNA
5 Function 13
5.1 Logic of function DIPA 14
5.2 Exclusion of the inputs STOP-FOTO-FCA-FCC DIPB 15
6 Managing of the REMOTE CONTROL DIP9 OFF 16
6.1 Cancellation of the memory
6.2 Activation of the codes
6.3 Memorization of the codes 17
7 Turn on and programm 18
7.1 Memorization of the working time
7.2 Memorization of the working time with a command START 19
7.3 Use the input CLOSE for PARTIAL OPENING 20
7.4 Go back to the INPUT CLOSE for CLOSE FUNCTION
7.5 Increase the PAUSE TIME 21
7.6 Fixed light or ashing
8 Note
9 Dichiarazione CE di conformità 22