• 12/24Vdc control board for one motor
• For Sliding gates, roll up doors, rolling shutters
• Connection with encoder
Manual and operating guide for the installer
-1-
2002/95/EC
RoHS
C O M P L I A N T
*Power supply of the photo-beams:
Terminal Boards 5-6
Max absorption 1.6 A
-2-
-3-
-4-
-5-
-6-
-7-
-8-
-9-
-10-
-11-
-12-
-13-
-14-
-15-
-16-
-17-
-18-
-19-
-20-
-21-
Input for LOW TENSION
Motor
Input for LOW TENSION
Motor
Power supply of the accessories (max 1,6 A)
Isolated contact for lamps
Power supply of the accessories (max 1,6 A)
Isolated contact for lamps
Isolated contact for key lock or signal light
STOP
Isolated contact for key lock or signal light
PHOTO when closing
LSC
LSO
START
- Antena / Com. contact for services and securities
CLOSE
+ Antena
Signal for ENCODER
+ 5Vdc power supply of the ENCODER
- power supply for ENCODER
M
MOT 1
Signal light
12/24 Vac/dc
N.O. N.O. N.C. N.C. N.C.
TX RX
Photocell
activated
when
closing
*
- + - +
*
+ BAT
Fastom for the connection of the battery
- BAT

START-S7LT Operating guide
-2-
Premises
Thismanualprovidesallthespecicinformationyou
need to familiarize yourself with and correctly ope-
rate your unit. Read it very carefully when you pur-
chase the instrument and consult it whenever you
have doubts regarding use and before performing
any maintenance operations.
Environmental protection
measures
Information regarding the environment
for customers within the European
Union. European Directive EC 2002/96
requires that units bearing this symbol
on the unit and/or on the packaging be
disposed of separately from undifferenti-
ated urban wastes.
The symbol indicates that the product must not be
disposed of with the ormal household wastes. The
owner is responsible for disposing of this prod-
uct and other electrical and electronic equipment
throughspecicwastecollectionfacilitiesindicated
by the government or local public agencies. Correct
disposal and recycling help prevent any potentially
negative impact on the environment and human
health. To receive more detailed information regard-
ing disposal of your unit, we recommend that you
contact the competent public agencies, them waste
collection service or the shop where you purchased
the product.
Piccol
Small legend
LSO or FCA Open limit switch
LSC or FCC Close limit switch
START control to drive the door AUTO-choice
PARTIAL OP. in sliding units: control partial opening
Vac alternate current
Vdc direct current
NC normally closed
NO normally open
Isolated contact isolated from power supply
Index
Par. Description Page
1 Introduction 3
1.1 Safety precautions
1.2 Symbols and warning
1.3 Type of installation
2 Description of the connections 4
2.1 Product description
2.2 Field of application
2.3 Technical description
3 Premises 5
3.1 Preliminary checks
3.2 Type of electrical wires
3.3 Notes on connections
4 Installation 6
4.1 Scheme of the control unit and electrical connections
4.2 Adjustment of the FORCE, SPEED and SLOWING DOWN
4.3 Description of the electrical connections
4.4 Checking connections
4.5 Connection of the POWER SUPPLY and BATTERY 8
4.6 Connection of the MOTOR
4.7 Connection of the encoder
4.8 CONNECTION OF THE LAMPS
4.9 Connection of the LIGHT 9
4.10 Connection of the electrical lock
4.11 Connection of the STOP
4.12 Connection of the Open and Close limt switches 10
4.13 Connection of the PHOTO A (only closing)
4.14 Connection of the START commands 11
4.15 Connection of the CLOSING / PEDESTRIAN
4.16 Power supply of the accessories
4.17 Connection of the ANTENNA
5 Function 13
5.1 Logic of function DIPA 14
5.2 Exclusion of the inputs STOP-FOTO-FCA-FCC DIPB 15
6 Managing of the REMOTE CONTROL DIP9 OFF 16
6.1 Cancellation of the memory
6.2 Activation of the codes
6.3 Memorization of the codes 17
7 Turn on and programm 18
7.1 Memorization of the working time
7.2 Memorization of the working time with a command START 19
7.3 Use the input CLOSE for PARTIAL OPENING 20
7.4 Go back to the INPUT CLOSE for CLOSE FUNCTION
7.5 Increase the PAUSE TIME 21
7.6 Fixed light or ashing
8 Note
9 Dichiarazione CE di conformità 22

START-S7LT Operating guide
-3-
DANGEROUS
This is a warning and if it is not
respec it can provoque material
damage.
DEVICE UNDER TENSION
The installation should be done
only from professional installer.
Usingtheunitimproperlyandperformingrepairsormodicationspersonallywillvoidthewarranty.Theprodu-
cer declines any responsibility for damages due to inappropriate use of the product and due to any use other
than the use the product was designed for. The producer declines any responsibility for consequential damages
except civil liability for the products.
Rememberthatsystemsforautomaticgatesanddoorsmustbeinstalledbyhighlyqualiedtechniciansonly
and in full compliance with current law. Before starting installation, check that the mechanical consistency and
sturdiness of the gate or door, check that the mechanical stops are suitable to stop the movement of the gate
or door even if the electrical limit switches should fail or during manual operations.
1.1 Safety precautions
READ CAREFULLY THE
OPERATING MANUAL
Read carefully this manul before
installation and keep it for the fu-
ture.
1.2 Symbols and warning
1.3 Type of installation
1 Introduction
It is important to make an important risk analysis of the “MACHINE” and of the customers requirements in order
to decide how many products should be installed. All NOLOGO photocells dispose of a synchronisation system
which permit to avoid any interference between two couples of photocells (look the photocell’s instructions for
details) In the diagram, photocells “FOTO A” in opening they have no effect, while it provoque a complete
inversion during closing. “FOTO A2” is the serial connection of “FOTO A” or “ALT, FOTO B” is the photocell
working by closing and opening.
Installations for swing gates Example in a roll-up door
We recommend to install a STOP switch which stops immediatelly the gate. The switch has a normally close
contact which opens the contact when it is working. See Par. 4.11
PHOTO A
PHOTO A2
PHOTO A2

START-S7LT Operating guide
-4-
Speed adjustment of slowing down.
Self-learning of operating times
Electronic regulation of the motive force
4 operating modes (condominium included)
Functions set with dip switches
Small size
2.1 Product description
2 Description of the connections
START-S7 LT is a new generation electronic circuit board with times count and digital deceleration. It has been
built to meet many needs: for sliding gates, swinging and roller systems. Its reduced size makes it suitable
for use it in all motors that are designed for internal electronics. The design has adapted the most advanced
techniquestoguaranteeutmostimmunityvs.noise,maximumoperatingexibilityandtomakeawidechoice
of functions available.
The START-S7 LT electronic control unit is used to control the movement of entrances, swinging gateways,
rolling gates and automatic doors.
2.2 Field of application
Dimensions 106 x 78 x 35 mm
Weight 150 g
Power supply 12 / 24
selectable by jumper J12 Vac
Maximum motor power Check that the transformer delivers adequate power,
for the motor installed on the system.
Maximum signal light power 25 W
Absorption MAX isolated contact 2 A
Absorption MAX
Accessories 1.6 A
2.3 Technical description

START-S7LT Operating guide
-5-
3.2 Type of electrical wires
Depending on the installation, the type and number of devices installed, the number of cables needed can vary.
The table below shows the cables needed for a typical installation. The cables used in the installation must be
IEC 60335 compliant.
Motor cable (if not equipped) Cable 2 x 2 mm2
Flashing signal Cable 2x1,5 mm2
Antena Shielded cable type RG58
Key selector Cable 3x0,5 o 0,75 mm2
Photocell receiver Cable 4x0,5 o 0,75 mm2
Photocell transmitter Cable 2x0,5 o 0,75 mm2
3.3 Notes on connections
To guarantee operator safety and to prevent damaging the components, never make connections or insert
wireless receiver boards while the control unit is powered. Power the control unit through a 3 x 1.5 mm cable. If
the distance between the control unit and the ground systemconnection is more than 30 m, a ground plate must
be installed in proximity to the control unit.
•Ifthemotorsdonothaveacable,usethe4x1.5mmcable(open+close+common+ground).
•Inconnectingthepartwithanextremelylowsafetyvoltage,
use cables with a minimum section of 0.5 or 0.75 mm2.
•Useshieldedcablesifthelengthexceeds30m
and connecting the ground braid only from the side of the control unit.
•Donotconnectthecablesinundergroundcaseseveniftheyarewater-tight.
•Iftheyarenotused,theinputstotheNormallyClosed(NC)contactsmustbejumperedtothecommon”.
•Ifthesameinputhasmorethanonecontact(NC),theyareplacedinseries.
•Iftheyarenotused,theinputstotheNormallyOpen(NO)contactsareleftloose.
•Ifthesameinputhasmorethanonecontact(NO),theyaretobeplacedinseries.
•Thecontactsmustbemechanicalandfreeofanypotential.
Making the correct choice of installation is essential to ensuring adequate safety and good protection against
atmospheric agents. Remember that the control unit contains powered parts and electronic components which
bytheirverynaturearesensitivetoinltrationsandmoisture.Thecontrolunitissuppliedinacontainerwhich
guarantees an IP55 protection rating if adequately installed. Install the control unit on a permanent surface that
isperfectlyat,adequatelyprotectedagainstimpactsandatleast40cmofftheground.Thecablesmustenter
the control unit from the bottom only; we recommend using wire leads and water-tight connections. When using
tubingthatcouldllupwithwaterorifthetubingcomesfromanundergroundwell,thewiresmustentera
rst shunting box placed at the same height as the control unit and then, from there, the wires must be passed
into the container holding the control unit, again entering from the bottom. This prevents any evaporation of the
water in the tubing from forming condensation inside the control unit itself.
3.1 Preliminary checks
3 Premises

START-S7LT Operating guide
-6-
4.1 Scheme of the control unit and electrical connections
4 Installation
BLOCK HIGH SPEED LOW SPEED
Adjustment of the force Adjustmen of the speed Adjustment of the
slowing down
FORCE Max
FORCE Min SPEED
Min
OFF
slowing
MAX
slowing
SPEED
Max
4.2 Adjustment of the FORCE, SPEED and SLOWING DOWN
1 2 3 4
J12V
+ BAT
- BAT
Use the correct
cable to connect
the battery and re-
spect the polarity.
DON’T CONNECT
DIRECTLY THE
BATTERY.
As the cable has
a charge circuit,
fuse and diode of
power suplly.
WARNING: The
control unit has
an emergency
module, connect
the battery to the
emergency modu-
le as shown in the
scheme.
!

12/24 Vac/dc 1Input for low tension: set up the JUMPER J12
2
Motor 3Output for the connection of the MOTOR
4
- 12/24 Vdc 5 Output for the connection of the accessories: Absorption max 1.6 A
+ 12/24 Vdc 6
i.c. Lamp 7Isolated contact for LAMP
8
contact for elec.
lock / signal light
9Isolated contact for ELEC. LOCK or SIGNAL LIGHT
10
Stop 11 Ingresso STOP
Photo CL 12 Input photocell PHOTO: operating only when closing
OLS 13 Input for Open Limit Switch
CLS 14 Input for Close Limit Switch
Start 15 Input for START command: set up DIP 1 and DIP2
Close 16 Input CLOSE command
Common 17 Common, services and securities
+ Antena 18 Positive pole antena
+ 5 Vdc 19 Power supply of the Encoder
Sgn Encoder 20 Encoder signal
- 5 Vdc 21 Power supply of the Encoder
START-S7LT Operating guide
-7-
4.3 Description of the electrical connections
We remind you that in
case some inputs are not
used, (STOP, FOTO) you
need to be deactivated
with DIPB as shown in the
Par 5.2
!
TheLEDL1indicatethecorrectlogicofthecontrolboard.Itasheseachsecondanditindicates
that the micro-chip is activated and it is waiting for a command.
When the control board is powered, the led are lit on when the input is a closed contact.
Normally the red led STOP - PHOTO - OLS - CLS are lit on
Normally the green led in in the START - CLOSE are switched off
STOP PHOTO OLS CLS START CLOSE
4.4 Checking connections

4.7 Connection of the ENCODER
START-S7LT Operating guide
-8-
4.5 Connection of the POWER SUPPLY and BATTERY
4.8 Connection of the LAMPS
4.6 Connection of the MOTOR
34
1
Pay attention not invert the poles OPEN and CLOSE.
In case of doubts out manually the gate in the middle of the stroke.Keep ready
to stop the gate with a STOP COMMANDE.
Interrupt the photocells if you want to check the correct open, if the gate starts
closing , the connection is wrong and you need to invert the cables OPEN with
CLOSE of the motor. MOTOR
6 7 85 10 11 129 14 15 1613 1817
Connection
of the LAMP
!
19 2120
Signal for encoder
- power supply of the ENCODER
+ 5V power supply of the ENCODER
For a correct use of the encoder,
we recommend to ready the man-
ual.
!
The following control board can be
powered 12/24Vac/dc. To set up
the power supply put the jumper
12V as shown:
12 Vac/dc 24 Vac/dc
2
34
1 2
Power Supply
In case you activate the pre-
lighting see Par. 5.1
!Use the correct cable to connect the
battery and respect the polarity. DON’T
CONNECT DIRECTLY THE BATTERY.
As the cable has a charge circuit, fuse
and diode of power suplly. WARNING:
The control unit has an emergency
module, connect the battery to the
emergency module as shown in the
scheme.
It is possible to activate or
deactivate the ashing light
for the output of the Light
during the memorization of
the working time Par. 7.2

START-S7LT Operating guide
-9-
4.9 Connection of the LIGHT
DIP 8 - ON
ON
CTS
2
143 6
587 10
91211
4.11 Connection of the STOP
11 12 13 14 15 16 17 18
Connection of the STOP control
Push-button: stops and temporarily prevents all control
unit function until it is pressed again.
Switch: keeps the automation blocked until it is reset.
Connection of the safety devices requires the use of any push-
button or N.C. (normally closed) contact. When there are
several safety devices, they are connected in series.
If the input STOP is
not used bring DIP 1B
in ON
!
If you bring DIP8 in ON you can connect
a signa light which will be lit on before
opening and two minutes after closing.
Signal light activated
with the second channel
of the remote control
10
6 7 85 10 11 129 14 15 1613 1817
GROUP OF
LIGHT Besides the second channel of the remo-
te control doesn’t close but it activate or
deactivate the signal light.
4.10 Connection of the ELECTRICAL LOCK
6 7 85 10 11 129 14 15 1613 1817
DIP 8 - OFF
ON
CTS
2
143 6
587 10
91211
If you put DIP8 in OFF you can connect
an electric lock. If you install a signal light
(Courtesy light) it is not possible to con-
nect an electrical lock.

START-S7LT Operating guide
-10-
4.12 Connection of the Open and Close limt switches
It is shown in the picture the connection of both limit switches:
The contacts of limit switches
are normally closed
If the open and close limit
switche are not used, bring
DIP 3B in ON (open limit
switch) and DIP 4B in ON
for close limit switch.
!
6 7 85 10 11 129 14 15 1613 1817
CLOSE
OPEN
power supply of
the photo -beam (TX)
+
-
+
-
4.13 Connection of the PHOTO A (only closing)
Photo-beam receivers.
N.C. terminal board.
The normally closed contact of
the receiver should be isolated
from tension.
If you you more couples of
photobeams the connection
should be serial.
If the input PHOTO
is not used bring DIP
2B in ON
!
6 7 85 10 11 129 14 15 1613 1817
+-
power supply of
the photo -beam

START-S7LT Operating guide
-11-
4.14 Connection of the START commands
The START command can be can be connected with each
button or normally open contact to the terminal board no.
15-17 . If more devices are available, connect them in pa-
rallel.
You can connect a TIMER to the terminal board to pro-
gramm the opening time of the gate. The contact of the ti-
mer should be normally open and it should be closed for all
time the gate is open. If the open command is connected to
the terminal board 15, connect it in parallel.
10 11 12 14 15 1613 1817
4.15 Connection of the CLOSING / PEDESTRIAN
The CLOSE input can be used as PEDESTRIAN com-
mand, a command to switch to CLOSE PEDESTRIAN
and vice versa, refer to Page 20
The connection of the closing can be connected to each
button or a n.o. contact.
10 11 12 14 15 1613 1817
16 17 18
4.16 Power supply of the accessories
If you use a cable for the antenna cut it at 17cm
for the 433.92MHz frequency and connect it to
the terminal board no.18.
Coaxial cable
4.17 Connection of the ANTENNA
Absorption Max: 1.6 A
6 7 85 10 11 129
CONNECT THE ANTENNA ONLY AFTER
LEARNING OF REMOTE CONTROL CODES!


START-S7LT Operating guide
-13-
5 Function
The control unit START S7LT is for automatic doors, too. Now we can see the correct installation. First of all
there are two functions: STANDARD function and AUTOMATIC DOOR function.
STANDARD FUNCTION (Default)
Encoder
The control unit opens and closes with an addi-
tonal time of 2 sec to support the latch.
Obstacle detection
The intervention of the obstacle detection is
consider as limit switch
AUTOMATIC DOOR FUNCTION
Encoder
The control panel stops the motor in the position set
during learning.
Obstacle detection
During the opening phase, the central reverses the
motor direction and executes a closure at low speed.
During the closing phase of the central reverses the
motor direction. Whether OPENS CLOSES during the
slowdown that the intervention is considered as limit
switches.
The control unit START-S7LT has two versions available. Make as follow to program the different versions:
1Turn off the control unit, take out the 230V tension
2Connect the control unit START-S7LT after a while again
3LED1 remains lit for 5 seconds LED1
4Press and release the button P1 in 5 seconds
5CounttheashoftheLED L1
LED1
61 ash: it has been activated the STANDARD VERSION (Default)
2 ashes: it has been activated the AUTOMATIC DOOR VERSION
7If you want to change the version, go back to point NO. 4
otherwise choose from the list P1.
P1

5.1 Logic of function DIPA
The control unit has a number of micro-switches which activate different functions for a safety installation and
suitable to the customer’s requirements:
1-OFF 2-OFF automatico By every order it inverts: open and close. It clo-
ses automatically at the end of the pause time
1-ON 2-OFF collective use
It doesn’t accept any order in pause and ope-
ning, it recloses automatically at the end of the
pause time.
1-OFF 2-ON step by step At the end of each comand follow the logic:
open-stop-close-stop-open… etc
1-ON 2-ON
bistable
with automatic
reclosing
Each commande the logic is: open-stop-close-
stop-open. It recloses automatically at the end
of the pause time.
3-ON
reversing and
closing stroke
(DIP 8)
With DIP 8 in ON
It activate the reversing stroke when it reaches
the close limit switch.
With DIP 8 in OFF
It activate the reversing stroke and closing stroke.
4-ON “death man“
function Itactivatethe“deathman”function
5 - ON torque relay Set up of the torque relay:
aceleration and deceleration
ON
2
143 6
587 10
9
ON
2
143 6
587 10
9
ON
2
143 6
587 10
9
ON
2
143 6
587 10
9
ON
2
143 6
587 10
9
ON
2
143 6
587 10
9
ON
2
143 6
587 10
9
5-OFF torque relay The motor starts after 1 sec.
after the re-start of the motor
6 - ON prelighting It activate pre-lighting of 2 sec
ON
2
143 6
587 10
9
ON
2
143 6
587 10
9
START-S7LT Operating guide
-14-

START-S7LT Operating guide
-15-
7-ON allow the
encoder input
Put in ON to allow the input of the encoder.
In case it doesn’t connect,
put the dip switch in OFF
8 - ON signal light
It is possiblE to connect a signal light, which it
will be turned on from the gate opening after 2
minutes after closing. Besides the second chan-
nel of the transmitter activate or deactivate the
courtesy light.
ON
2
143 6
587 10
9
ON
2
143 6
587 10
9
8-OFF electrical lock It permet the electrical lock
9 - ON
memorization
of the time and
position
Memorization of the working time and position
ON
2
143 6
587 10
9
ON
2
143 6
587 10
9
10 -Not used
ON
2
143 6
587 10
9
5.2 Exclusion of the inputs STOP-FOTO-FCA-FCC DIPB
1-ON STOP Exclusion of the input STOP
2-ON FOTO Exclusion of the input PHOTO
3-ON OLS Exclusion of the input OLS
4-ON CLS Exclusion of the input CLS
ON
2
143
ON
2
143
ON
2
143
ON
2
143

START-S7LT Operating guide
-16-
6 Managing of the REMOTE CONTROL DIP9 OFF
Thisreceivercanmanagestandardcodesfrom12till64bitandrollingcodesHCS©.Therstlearnedtransmit-
ter establish the code’s type taht the receiver has to manage, it means that the transmitter has to have the same
code’s type. Concerning the rolling codes it is possible to activate or disactivate the key’scontrol and the rolling
counter. With this function you can choose the security level of the receiver.
6.1 Cancellation of the memory
The control unit dispose of a button P1 to cancel the memory of the remote controls.
To do this operation make as follow:
The outputs are deactivated, so no contacts available, the connected lights should be switched off.
This operation is possible only when the gate is closed.
1 Press and keep presse the button P on the control board, LED L1 will lit on
2
After 6 seconds the LED L1 will turned off and now you can release the button P1.
LEDL1willash4timesthenitwillashregularlyanditisreadytomanagethexedcode
(1regularashseenextchapter).Thememoryiscancelled.
1Press and keep presse the button P on the control board, LED L1 will lit on.
2In these 6 seconds press and release button P,LEDL1willashoneanditwilllitonfor6seconds.
3In 6 seconds press and release P1again,LEDL1ashestwiceandthenitashesconstantly,
this memorize the rolling code remote controls.
ThereceiveroftheSTART-S7LTcanmanagexedandrollingcode.Theoutputsshouldbedeactivated,nocontacts
available, lights turned off. This operation is possible only when the gate is closed
LED L1 in normal condition indicates the type of code you are managing
1 regular ash:itwillbemanagedcompatiblexedcode
2 regular ash: it will be managed only rolling code remote like: serie Smile, Smart”
In case you need to manage the compatible xed code follow the passages 1 and 2 and wait until LED L1 will be
switchedoff.Inthiscasetherstmemorizedcodedeterminestheytypeofcodewhichshouldbememorized.Ifyouhad
to memorize a 12bit remote control (for example dip switch) it will be memorized 12 bits of the same version
6.2 Activation of the codes

START-S7LT Operating guide
-17-
The control unit dispose of a BUTTON P1 to programm the time and the memorization of the remote controls.
If you memorize a SMILE-C, make sure that all buttons have a code otherwise you need to generate a
new code. If you need to memorize a rolling code SMILE-H you don’t need to self-generate a code.
The ouputs need to be dactivated, so no contacts available and lights should be turned off.
This procedure is possible only when the gate is closed. LED L1 has to ash regularly see
“Activation of codes” in the previous paragraph.
CONNECT THE ANTENNA ONLY AFTER LEARNING OF REMOTE CONTROL CODES!
1Press and release button P1 in the control board, LED L1 will lit on for 6 seconds. Then...
2
In6secondspressthebuttonoftheremotecontrolswhichOPENS(START)wesuggesttherst
channel.LEDL1willash5timestoconrmtheoperationanditwillashregularly.CodeOPENS
memorized.
If LED L1 will ash regularly without ashing 5 times, it means that the memory
code is full and it doesn’t accept any remote controls.
For 20 bits the capacity of the code is 22 codes,
If you need to memorize more codes you need to install a supplementary receiver RX2 or RX4
with a capacity of 3000 codes.
If you are not sure that this procedure is correct start from point no.1 again but cancel the memory before.
It is important to start from the previous chapter (Cancellation of the memory)
ThisfunctionworksintheDIPA1and2see“Logicoffunction”:
1Press and release button P1 in the control board, LED L1 will lit on for 6 seconds. Then...
2In this time press and release button P1 in the control board, LED L1 will lit on for 6 seconds and then..
3
Press and release the button of the remote control which CLOSE we suggest the 2nd channel.
This function has the following logic: CLOSE-STOP-CLOSE it cannot be changed.
LedL1willashfor5timesanditwillashasinthebeignning.Thecodehasbenenmemorized
This function has the following logic: CLOSE-STOP-CLOSE and it cannot be changed:
MemorizetherstchanneloftheremoteOPEN(START)
Memorize the second channel of the remote CLOSE
6.3 Memorization of the codes

7 Turn on and programm
Whenthecontrolunitwillturnonagain,ifeverythingwillbeconnectedintherightway,ledL1(red)shouldash
while the led of inputs STOP - PHOTO - OLS - CLS - ALT - SAFETY EDGE should turned off (if the gate is
closed OLS is turned off). The led START and PED should turned off. When you turned off the control unit, the
gate is opening it means that the control card has been previously turned off while it was open .
If you had to set up the working time. Turn off the control card, close the
gate, put DIP9 in ON and give power supply to the control card.
Put in ON the DIP9 and you can set up
- working time and pause time
- position of the slow down
- activation or deactivation of the lamp in pause time
7.1 Memorization of the working time
Here you can memorize the working time.You need to use the START command. Those commands can be
used with a device connected to the terminal board 15-17 or from a memorized remote control (see MEMORI-
ZATION OF THE REMOTE CONTROL)
This operation is possible only when the gate is closed. Start from the initial condi-
tion of the control unit.
Put DIP9 in ON before powering the control unit.
It is necessary to set up the mechanical closing limit switches (when closing and opening)
START-S7LT Operating guide
-18-
ON
2
143 6
587 10
9

START-S7LT Operating guide
-19-
7.2 Memorization of the working time with a command START
2
143 6
587 10
9
1Take the power supply and put DIP9 in ON.
The gate is
CLOSED
2 Give power supply to the control unit.
3Press the START button (all which is connected to the terminal
board no.15 or in the 1st channel of the remote control)
The gate is
OPENING
4Press STARTtodenywhentheautomationstartsslowing
down otherwise read the next passage.
The gate is
SLOWING
DOWN
5A If the open limit switch is not available, when the gate reach the
stroke, press the START comand. The gate
STOPS
5B If the open limit switch is connected, you don’t need to do
nothing as the limit switch boost the programm.
6Let the time goes until the gate is opening.
This is the
automation
“PAUSETIME”
7The automation is in PAUSE TIME
The automation
starts in
CLOSING mode
9Press START when the gate starts to slowing down, otherwise
you need to read the next passage.
The gate is
SLOWING
DOWN
10 Wait until the gate stops automatically. The gate is
CLOSED
11 Put in OFF the DIP9 to return in the standard function. The
signal light turned off and LED L1 will starts again.
End of the
memorization of
the working time
2
143 6
587 10
9
IF YOU DON’T USE AN ENCODER:
Memorize the time with the trimmers (speed)

START-S7LT Operating guide
-20-
7.3 Use the input CLOSE for PARTIAL OPENING
1Take the power supply and put DIP9 in ON. The gate is
CLOSED
2 Give power supply to the control unit. (Led L1 is
turned off when the control board is programming)
The gate is
OPENING
3
Press the CLOSE command (everything connected
to input 16 or the 2nd channel of the compatible
remote control that has been learned)
The gate is
OPENING
4Press the CLOSE command to stop the automation
at the desired point (end of partial opening).
The gate is
SLOWING DOWN
5Let the time elapse during which the automation
must remain open.
This is the
automation
“PAUSETIME”
6Press CLOSE command to start closing
The automation
starts in
CLOSING mode
7Wait for the automation to stop automatically The gate is
CLOSED
8
Put in OFF the DIP9 to return in the standard
function. The signal light turned off and LED L1 will
starts again.
End of the
memorization of the
working time
4
2
143 6
587 10
9
2
143 6
587 10
9
7.4 Go back to the INPUT CLOSE for CLOSE FUNCTION
1Take the power supply and put DIP9 in ON.
2 Give power supply to the control unit.
(Led L1 is turned off when the control board is programming)
3Press and hold the CLOSE command (everything connected to input 16 or the 2nd
channel of the compatible remote control that has been learned)
4Wait until the LED1 starts blinking (about 5 seconds)
5Release the button CLOSE
6Put in OFF the DIP9 to return in the standard function. The signal light turned off and
LED L1 will starts again.
4
2
143 6
587 10
9
2
143 6
587 10
9
In case you need to use the input CLOSE for PARTIAL OPENING, make as follow: