The first week
Regular maintenance
Trouble shooting
Beware!
1. Monitor the unit every day
– Bulking agent should be porous and have a moderately moist texture
–The mixing mechanism should automatically activate with each use
–The mixing mechanism may activate occasionally when the unit is not in use
2. The compost tray may be full of dry humus, which can be emptied back into the top chamber.
3. Add a handful of bulking agent for every #2 you do – or about 1 litre once a week
4. Check the uid level indictor tube on the side of the unit
–If you can see liquid in the tube, turn the thermostat up one click
–The thermostat setting may vary depending on the use patterns and climate
1. Check the uid level indicator tube regularly and adjust thermostat accordingly
–Fluid showing = turn thermostat up
2. Add bulking agent regularly
3. Empty the compost tray BEFORE it is full
–Most people empty it once a month to avoid overlling
1. Odours detected
□Urine/damp odour
■Turn thermostat up one click and monitor
■Ensure vent pipe is well insulated (to prevent condensation issues)
□Strange burnt odour
■Turn thermostat down one click and monitor
■Check moisture level of the pile
– Sprinkle 500ml of water on bulking agent if it appears dry
2. Liquid leaking onto oor
□Check uid level indicator tube on side of unit
□If liquid is visible in the tube, turn the thermostat up one click and monitor
□Ensure the vent pipe is well insulated (to prevent condensation in the vent pipe)
□ONLY USE wood shavings and/or peat moss in your EcoLet
□Do NOT use sugarcane mulch or other stringy brous material
4
EcoLet bulking agent
EcoLet
bulking agent