manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Econex
  6. •
  7. Control Unit
  8. •
  9. Econex BSV Series User manual

Econex BSV Series User manual

The buttery valves of the series BSV are DVGW ap-
proved to the Norm EN 161 with product identi-
cation number.
They are suitable to be used on residential and in-
dustrial combustion systems. They are particularly
suitable for both manual and automatic control of
gases belonging to the rst, second and third family
and of air.
Installation with two threaded anges from Rp 3/4
to Rp 2.
Buttery valve
series BSV
• Sturdy, compact construction, especially suitable for industrial applications
• Installation in any position
• Mechanical position indicator
• Lockable rotation angle from 0° to 90°
• Low leakage at valve in closed position 1% of max. kv
• Wide range of accessories on request:
Body and anges Aluminium
Stem Stainless steel AISI 303
Buttery disc Aluminium or AISI 304
Threaded anges From Rp 3/4 to Rp 2 according to norms EN 10226
Max. pressure 500 mbar
Temperature -10 ÷ +60°C for gas -10 ÷ +80°C for air
Temperature on request -10 ÷ +110°C or +200°C for air
Control ratio 10:1
Valves ow Bidirectional
FEATURES
TECHNICAL FEATURES
• manual control lever
• 1 o 2 internal reductions with respect to the nominal diameter of the valve
• buttery disc AISI 304 for air temperature up to 200 °C
4
MODELS
Molle di taratura pressione
DN Connection
Rp Orice diameter
(mm)
MODEL
Manual control Free sharft
20 3/4 20 BSV20.A BSV20.B
25 120
25
BSV25/20.A
BSV25.A
BSV25/20.B
BSV/25.B
32 1.1/4
20
25
32
BSV32/20.A
BSV32/25.A
BSV32.A
BSV32/20.B
BSV32/25.B
BSV32.B
40 1.1/2
25
32
40
BSV40/25.A
BSV40/32.A
BSV40.A
BSV40/25.B
BSV40/32.B
BSV40.B
50 2
32
40
50
BSV50/32.A
BSV50/40.A
BSV50.A
BSV50/32.B
BSV50/40.B
BSV50.B
NOTE For max. temperature of 110 °C add “1” to letters “A” or “B”
For max. temperature of 200 °C add “2” to letters “A” or “B”
FLOW CHART
p (mbar)
VN (m3/h)
Aria
Metano
Gas di città
Propano
Butano
G.P.L.
dv=1
dv=0,64
dv=0,45
dv=1,56
dv=2,09
dv=1,70
Air
Methane
Town gas
Propane
Butane
L.G.P.
DN F A B C H I L CH Weight Kg
20 Rp 3/4 60 86 22 98,5 42 42,4 42 0,8
25 Rp 1 60 86 22 98,5 42 42,4 42 0,7
32 Rp 1.1/4 90 95 25 128,5 45 70,7 60 1,5
40 Rp 1.1/2 90 95 25 128,5 45 70,7 60 1,4
50 Rp 2 90 95 25 128,5 45 70,7 74 1,6
DIMENSIONS
Dimensions in mm
1. WARNING
Installation, adjustment and maintenance of the valve must be carried out exclusively by skilled and authorized ser
vice technicians. Non-proper installation, adjustment, changes, use and maintenance may cause damages to the per
sonnel or to the equipment. Consequently, it is necessary to respect strictly the following instructions and local pre
scriptions for both the installation of electric devices, in case of motorized valves, and of gas systems.
2. INSTALLATION
2.1 Make sure that all operating data indicated on the valve label correspond to those of the system.
2.2 When installing the valve be sure that there is sufcient clearance above the gear cover and that it can be easily accessible in
order to perform manual servicing, automatic servicing by means of a gear motor or servicing by means of levers.
2.3 For the valves of the BSV series proceed as follows:
remove the protection plugs from the threaded anges,
screw the threaded anges to the inlet and outlet pipes, using exclusively sealing materials suitable for gases,
insert the BSV valve between the two anges with “O” rings,
tighten the anges to the valve body by means of the respective bolts.
2.4 The installation of the BSV valves can be performed in any position.
2.5 The valve can be installed in any location except where acid fumes or other deteriorating vapour may attack its metal parts or
where gas leaks or explosive vapours are present in the atmosphere.
2.6 Do not use the valve as a lever.
3. OPERATING
3.1 Before operating the following points must be checked carefully:
tightness of the external gas pipes;
that valve adjustment is performed within the requested angle range;
that mechanical locks or other retainers, which may damage the valve, have been removed.
3.2 Once these preliminary checks have been performed, the main gas tap can be opened and the operation test can be curried
out.
4. MAINTENANCE AND CHECKS
4.1 The BSV valves do not require any particular current maintenance because they do not need lubrication.
4.2 It is recommendable to check at least once a year that the mechanical connections have not been modied, especially in case
of systems, which do not function vibration-free.
5. REPLACEMENT
In case replacement of the BFV valve is necessary, proceed as follows:
5.1 Close the main gas tap.
5.2 Remove the mechanical connections from the valve axis.
5.3 Remove the valve body from the inlet and outlet anges by loosening the fastening screws from the respective nuts.
5.4 Install the new valve proceeding as per instructions reported in the foregoing chapters.
All the reported data are subject to be changed without notice. form140906
Econex s.r.l. - Via Francesco De Sanctis, 53 - I-20141 Milano
Tel. +39 0289502912 - Fax +39 028463084 - www.econex.it - [email protected]
INSTALLATION AND OPERATING INSTRUCTIONS

This manual suits for next models

24

Other Econex Control Unit manuals

Econex MPV Series Instruction Manual

Econex

Econex MPV Series Instruction Manual

Econex VSB Series User manual

Econex

Econex VSB Series User manual

Econex MDV Series User guide

Econex

Econex MDV Series User guide

Popular Control Unit manuals by other brands

Axxess AX-DSPX-HD2-WR installation instructions

Axxess

Axxess AX-DSPX-HD2-WR installation instructions

Quectel UG96 manual

Quectel

Quectel UG96 manual

Hallco 56-4896 Operational & Service Manual

Hallco

Hallco 56-4896 Operational & Service Manual

Enclustra Mercury+ XU9 user manual

Enclustra

Enclustra Mercury+ XU9 user manual

SPX APV CU4 instruction manual

SPX

SPX APV CU4 instruction manual

Bailey Infi 90 IMCPM02 instructions

Bailey

Bailey Infi 90 IMCPM02 instructions

ABB FCAN-01 user manual

ABB

ABB FCAN-01 user manual

Ebyte E22-900M30S user manual

Ebyte

Ebyte E22-900M30S user manual

joke ENESKAmicro 600 operating instructions

joke

joke ENESKAmicro 600 operating instructions

WAGO 750-513 Series manual

WAGO

WAGO 750-513 Series manual

Carel E3V-C Series quick start guide

Carel

Carel E3V-C Series quick start guide

NCR 7703-K168 instructions

NCR

NCR 7703-K168 instructions

Nibe VVM 325 Installer manual

Nibe

Nibe VVM 325 Installer manual

CAME ZBX74-78 Spare parts

CAME

CAME ZBX74-78 Spare parts

Omron 3G3AX-RX-ECT instruction manual

Omron

Omron 3G3AX-RX-ECT instruction manual

Parker U131B01 Installation, operating,  & maintenance instructions

Parker

Parker U131B01 Installation, operating, & maintenance instructions

Genius JA388 Use and Installation Instructions

Genius

Genius JA388 Use and Installation Instructions

Comunello CU 230V HP Installation and user manual

Comunello

Comunello CU 230V HP Installation and user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.