Eden HA2000CO User manual

Carbon
Carbon Carbon
Carbon Monoxide Detector (
Monoxide Detector (Monoxide Detector (
Monoxide Detector (HA2000
HA2000HA2000
HA2000CO)
CO)CO)
CO)

LED
When the battery voltage is low, the AMBER LED will flash every 30
sec.
While the Carbon Monoxide Detector is transmitting the signal, the
RED LED will perform a long flash with “Ding Dong” melody.
While the batteries are inserted and the Carbon Monoxide Detector is
in warming period, the GREEN LED will flashes once every seconds
for 2 ~ 10 minutes.
While the sensor is taking CO concentration reading from the air, the GREEN LED will flashes
once every 30 seconds.

Installation Procedures
Step 1 Insert the 3 “AA” batteries into the battery compartment taking care that the connection
respects correct polarity showing on the battery holder.
Step 2 While the 3 batteries are inserted; the HA2000CO will sound a “Ding-Dong” melody and
the GREEN LED stays on.
Step 3 The warming up process takes between 2~10 minutes. The GREEN LED flashes every
second indicates that the warming up process is taking place. After the warming up period
is complete, the GREEN LED then flashes once every 30 seconds.
<NOTE>

While it is under the warming up period, if the Test Button has been pressed, it will send a
test code to the Control Panel and the RED LED will perform a long flash and “Ding Dong”
melody. After the transmitting process finishes, the GREEN comes back on.

If the Test Button has been pressed during the Stand-by mode, then the HA2000CO will be
transmitting a Test signal to report to the Control Panel. This is performed by a long flash of
RED LED and “Ding Dong” melody.
Step 4 Put the Control Panel into “Device +/-“ menu and then select “Add Device” menu.
Step 5 Press the CO detector’s test button on the front cover.
Step 6 Refer to the operation manual of your control panel under the section of “Device +/-“ to
complete the learn-in process.
Step 7 After the detector is learnt-in, put the Control Panel into “Walk Test” mode, hold the CO
detector in the desired location, and press the Test button to confirm this location is within
signal range of the Control Panel.
Step 8 When you are satisfied that the CO detector work in the chosen location, you can proceed
with installation.
While the HA2000CO is alarming, with the press of the Test Button will result to ‘cancel’ the
alarm signal and terminate the reporting process. This is performed by a long flash of RED
LED and “Ding Dong” melody.
 The alarm will be activated by:
<NOTE>

When the CO sensor detected any
unusual CO concentration in the air that
CO concentration
level Time taken before
alarming
30 ppm 120 minutes
50 ppm 50 minutes
100 ppm 10 minutes
300 ppm 2 minutes
500 ppm 30 seconds
matches with the above table, it will notify the control panel and trigger the alarm.

While alarming
LED: The RED LED will perform continuous fast flashes
BEEP: The buzzer will sound continuous short beeping
Signal: The alarm signal will be send out every 10 minutes to inform the control panel.
<NOTE>

While the HA2000CO is alarming, with the press of the Test Button will result to ‘cancel’ the
alarm signal and terminate the reporting process. This is performed by a long flash of RED
LED and “Ding Dong” melody.

If the CO concentration in the Air is less than 30 ppm, then the CO detector will automatically
cancels the alarm warning signal and re-start the detection again.

Specifications:
Common Technical Specification:
Radio frequency: 868.6375MHz +-2.5ppm
Modulation/ Demodulation: Narrow band FM @ 15KHz
bandwidth with VCTCXO (Temperature compensated
Crystal)
Sensitivity: >105dbm @S/N +20db
Transmission power: E.I.R.P. -8dbm +-3db
Operation range: 300 meters in open space
Code combinations: 16 777 216 codes
Temperature range:-20°C +45°C
Humidity: up to 90%
Carbon Monoxide Detector HA2000CO
Sensitivity: following EN50291
Detection Mode : electrochemical cell CO
Self diagnostic
Test button
Supervision: Random signals 30 min to 50 min
Weak battery detection
3 color LED : normal, alarm, default.
Integrated siren
Power: alkaline battery 3 xAA
Battery life: over 2 years
Detection cell life : 5 years
Detection range: 0 ~ 999 PPM
Alarm Concentration: 30 ~ 999 PPM

Guaranty
This product is guarantee 4 years except the
batteries. The first year is by standard exchange.
The 3 years left, the guarantee is for parts and
labours.
Please contact, the technical line, following your country, to
confirm the default and the guarantee process.
France:
Eden: 0825 560 650
Web site: www.eden.fr
Holland:
Elro: 0900 208 8888
Web site: www.elro-nl.com
Belgium:
Dutch speaking
Elro: 070 2330031
French Speaking
Eden: 0033 825 560 650
Germany:
Elro: 0049 17755 24123
England:
Byron: 0845 230 1231
Website: www.chbyron.com

Popular Gas Detector manuals by other brands

Beghelli Salvalavita manual

Beghelli

Beghelli Salvalavita manual

SENKO SP-MGTP user manual

SENKO

SENKO SP-MGTP user manual

BEINAT CO922 Guide

BEINAT

BEINAT CO922 Guide

MSA Ultima OPIR-5 Safety manual

MSA

MSA Ultima OPIR-5 Safety manual

Bosean Electronic Technology BH-90a user manual

Bosean Electronic Technology

Bosean Electronic Technology BH-90a user manual

Macurco GD-6 Operation manual

Macurco

Macurco GD-6 Operation manual

isweek AS8900 manual

isweek

isweek AS8900 manual

Coster RGS 328 instructions

Coster

Coster RGS 328 instructions

UFO Proline 0330002 user manual

UFO

UFO Proline 0330002 user manual

Crowcon IRmax Installation, operating and maintenance instructions

Crowcon

Crowcon IRmax Installation, operating and maintenance instructions

RPB GX4 08-400 instruction manual

RPB

RPB GX4 08-400 instruction manual

BEP Marine 600 Series Installation and operating instructions

BEP Marine

BEP Marine 600 Series Installation and operating instructions

Cool Air LBW-420-RLV manual

Cool Air

Cool Air LBW-420-RLV manual

König SAS-GD100 manual

König

König SAS-GD100 manual

AGS Mini Merlin Installation & operation manual

AGS

AGS Mini Merlin Installation & operation manual

Carel GLD Series user manual

Carel

Carel GLD Series user manual

Evikon PluraSens E2658-C2H4 user manual

Evikon

Evikon PluraSens E2658-C2H4 user manual

Seitron RGY 000 MBP4 Operation, installation, and maintenance manual

Seitron

Seitron RGY 000 MBP4 Operation, installation, and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.