SAFETY WARNINGS
Check that the voltage shown on the label of the unit corresponds to the voltage of the
mains supply. Connect the unit only to power supplies with residual current circuit breaker
(RCCD) with sensitivity of 30mA. Always disconnect all electrical appliances from the mains
before placing your hands in the water. The line cord cannot be replaced or repaired.
Should the cord become damaged the appliance must be discarded. Units marked with on
the label are for indoor use only. This unit must not be used in swimming pools or
bathrooms. This appliance has been designed for use in fluids up to 35°C. Keep these
instructions for future reference.
MAINTENANCE
Follow these instructions carefully for any maintenance, replacement of filter media,
cleaning operation, etc.
-Always disconnect all electrical appliances before placing your hands in water.
- Unlock the screw nuts and detach the hoses from the intake and outlet spigots (fig. 8) to
avoid siphoning of the tank.
- Move the complete filter on to a sink or similar place.
- Open the filter by pushing first the orange safety device and then sliding the clips toward
the right side (fig. 2).
- Open the pump chamber (fig. 9).
- Take off the rotor system and carefully wash under running water together with the other
components.
- Reassemble the parts paying care to the right positioning of the hose (fig. 9) that must be
oriented towards the upper side of the filter.
A special internal device (fig. 9) discharges the air that remains in the upper part of the filter
head. The length of this operation depends on the quantity of air inside and may take a few
minutes. The noise will disappear as soon as the system has discharged all the air.
Disposal: (in accordance with RL2002/96/EC) the product must not be added to normal
household waste. It must be disposed of properly.
INSTALLATION
Identify the parts you have found in the box and in the accessories bag.
Assemble the suction cups (G1) onto the clips (G2).
Mount the screw-nuts (E) onto the hard elbows (I) and on the filter head.
Insert the strainer (H) onto the intake tube (N).
Close one end of the spray bar tube (tube with holes P) with the tap supplied.
Mount the rubber elbow (M) onto the one hard elbow (I).
If you prefer to use the diverter (L) mount it directly onto the rubber elbow (M).
Insert the feet in their locations.
Open the filter by pushing first on the orange safety device, and
then slide the clip towards the right end side.
Open the ceramic media bag, wash them under running water
and insert them in the filter chamber.
Close the filter by pressing down the head completely and slide
each locking clip from right to left.
Open the top cap and fill up completely. To close the tap, rotate
it until the locking device clicks.
Thoroughly clean the wall before pressing the suction cups and
tube against it.
Press the suckers on the spray bar against the thoroughly
cleaned wall.
Push the pipes onto their spigots and lock with the screw nuts.
A - 9922-01 F - 9922-05 N - 9922-10
B - 9922-02 G - 9922-06 P - 9922-11
C - 9922-03 H - 9922-07 Q - 9908-04
D1 -50Hz 9901-01 I - 9922-08 R - 9922-12
D2 -60Hz 9901-02 L - 9901-07 S - 9922-13
E - 9922-04 M - 9922-09 T - 9922-14
It is recommended that the filter is placed on the same level as
the tank.
For best performance place the filter in an upright position
beside the tank.
Avoid tight bends or kinks in the (inlet or outlet) pipes.
The filter will be closed only after pushing fully down the head
and the clips from the right to the left hand side.
WARRANTY
With this product we offer you a guarantee of 36 months from the date of purchase on
materials and manufacturing faults. This unit has been manufactured according to the IEC
EN 60 335-2-41, EN 60 335-2-55 Safety Standards, using high quality materials and the
most accurate manufacturing processes to grant the highest satisfaction and long lasting.
This guarantee does not cover any mishandling, damage or technical modification to the
unit. No replacement will be given for units that have not been properly maintained. The
guarantee will be honoured only if the unit is returned in its whole and together with the
receipt of proof or purchase. In case of returning under guarantee please return it
accompanied by this certificate of guarantee and the proof of purchase to your supplier. We
do reserve the right to repair or replace the unit. The guarantee does not cover cases of
damages that may result from misuse, tampering and negligence or from not observing of
the Safety Warnings. This guarantee does not cover parts subjected to natural wearing and
tear (i.e. rotors).

Other manuals for 501

1

Other Eden Water Filtration System manuals

Eden 511 User manual

Eden

Eden 511 User manual

Eden 373 User manual

Eden

Eden 373 User manual

Eden 501 User manual

Eden

Eden 501 User manual

Eden 304S User manual

Eden

Eden 304S User manual

Popular Water Filtration System manuals by other brands

Atlantic Ultraviolet Mighty Pure MP16A owner's manual

Atlantic Ultraviolet

Atlantic Ultraviolet Mighty Pure MP16A owner's manual

SunSun CBG-500 Operation manual

SunSun

SunSun CBG-500 Operation manual

Hayward XStream Filtration Series owner's manual

Hayward

Hayward XStream Filtration Series owner's manual

Contech DownSpout StormFilter Operation and maintenance

Contech

Contech DownSpout StormFilter Operation and maintenance

Teka Airfilter MINI operating instructions

Teka

Teka Airfilter MINI operating instructions

Wisy LineAir 100 Installation and operating instructions

Wisy

Wisy LineAir 100 Installation and operating instructions

Schaffner Ecosine FN3446 Series User and installation manual

Schaffner

Schaffner Ecosine FN3446 Series User and installation manual

Pentair FLECK 4600 SXT Installer manual

Pentair

Pentair FLECK 4600 SXT Installer manual

H2O International H20-500 product manual

H2O International

H2O International H20-500 product manual

Renkforce 2306241 operating instructions

Renkforce

Renkforce 2306241 operating instructions

Neo-Pure TL3-A502 manual

Neo-Pure

Neo-Pure TL3-A502 manual

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

STA-RITE

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

Applied Membranes W-G844EM Operation and maintenance manual

Applied Membranes

Applied Membranes W-G844EM Operation and maintenance manual

BEGA 116 Instructions for use

BEGA

BEGA 116 Instructions for use

WATA Standard operating instructions

WATA

WATA Standard operating instructions

Price FFU series Installation and service manual

Price

Price FFU series Installation and service manual

Gaggenau BRITA INTENZA 467873 manual

Gaggenau

Gaggenau BRITA INTENZA 467873 manual

Brita SAFF-100 user guide

Brita

Brita SAFF-100 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.