Quick Start Guide
– 2 –
Mount the Switch
Ground the Switch
Warning:
For a safe and reliable installation, use only
the accessories and screws provided with the AS9926-
24D. Use of other accessories and screws could result in
damage to the unit. Any damages incurred by using
unapproved accessories are not covered by the warranty.
Avertissement:
Pour une installation sûre et fiable,
utilisez uniquement les accessoires et les vis fournies avec
le AS9926-24D. L’utilisation d’autres accessoires et vis
pourrait endommager l’appareil. Les dommages causés
par l’utilisation d’accessoires non approuvés ne sont pas
couverts par la garantie.
Caution:
The switch includes plug-in power supply (PSU) and
fan tray modules that are installed into its chassis. Make sure all
installed modules have a matching airflow direction (front-to-
back or back-to-front).
Attention:
Le commutateur comprend des modules
d’alimentation et de modules de ventilation installés dans son
châssis. Assurez-vous que tous les modules installés ont une
direction d’air adaptée (avant-arrière ou arrière-arrière).
Note:
The switch has the Open Network Install Environment
(ONIE) software installer preloaded on the switch, but no switch
software image. Information about compatible switch software
can be found at www.edge-core.com.
Note:
The drawings in this document are for illustration only
and may not match your particular model.
Caution:
This device must be installed in a
telecommunications room or a server room.
Attention:
Cet appareil doit être installé dans une salle de
télécommunication ou une salle de serveur.
1. Attach the Brackets
Use the included screws to attach the front- and rear-post brackets.
2. Mount the Switch
Mount the switch in the rack and secure it with rack screws.
3. Lock the Rear-Post Brackets
Use the included screws to lock the position of the rear-post brackets.
Optional Slide-Rail Installation
An optional slide-rail kit is available for rack installation. Follow the
installation procedure provided with the kit.
Verify Rack Ground
Ensure the rack on which the switch is to be mounted is properly
grounded and in compliance with ETSI ETS 300 253. Verify that there is
a good electrical connection to the grounding point on the rack (no
paint or isolating surface treatment).
Attach Grounding Wire
Attach a lug (not provided) to a #12 AWG minimum grounding wire
(not provided), and connect it to the grounding point on the switch rear
panel. Then connect the other end of the wire to rack ground.
Installation