EDM Solution 6+6 Wireless-AE User manual

Solution 6+6
Operators Manual
ISSUE 1.23


Solution 6+6
Operators Manual
Copyright 1997 by Electronics Design and Manufacturing Pty Limited,
SYDNEY, AUSTRALIA
Document Part Number MA600O
Document ISSUE 1.23
Printed 01 December 1997
This documentation is provided to suit Solution 6+6 (CC600/LP600)
Firmware Revision 1.20 – 1.27
Hardware Revision A
Copyright Notice
All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval
system in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise,
without the prior written permission of Electronics Design and Manufacturing Pty Limited.
Trademarks
Throughout this document trademark names may have been used. Rather than put a trademark symbol
in every occurrence of a trademark name, we state that we are using the names only in an editorial
fashion and to the benefit of the trademark owner with no intention of infringement of the trademark.
Notice of Liability
While every precaution has been taken in the preparation of this document, neither Electronics Design
and Manufacturing Pty Limited nor any of its official representatives shall have any liability to any
person or entity with respect to any liability, loss or damage caused or alleged to be caused directly or
indirectly by the information contained in this book.
Electronics Design and Manufacturing Pty Limited reserves the right to make changes to features and
specifications at any time without prior notification in the interest of ongoing product development and
improvement.


Table Of Contents
Introduction........................................................................................................................................9
Features............................................................................................................................................10
Basic System Operation ....................................................................................................................11
Code Retries......................................................................................................................................12
Codepad Lockout Time ............................................................................................................................12
Codepad Extinguish Mode................................................................................................................12
Alarm Memory..................................................................................................................................13
Sensor Watch Time...........................................................................................................................13
Day Alarm.........................................................................................................................................14
Day Alarm Resetting.................................................................................................................................14
Day Alarm Latching .................................................................................................................................14
Operation...............................................................................................................................................................14
Entry Time........................................................................................................................................15
Exit Time ..........................................................................................................................................15
System Date and Time.......................................................................................................................15
User Codes ................................................................................................................................................ 16
User Code Priority .................................................................................................................................................17
System Indicators and Operations ....................................................................................................19
CP5 Eight Zone Codepad .........................................................................................................................19
Zone Indicators......................................................................................................................................................19
AWAY Indicator ...................................................................................................................................................19
STAY Indicator.....................................................................................................................................................19
MAINS Indicator...................................................................................................................................................20
FAULT Indicator...................................................................................................................................................20
Audible Indicators .................................................................................................................................................20
CP5 Eight Zone LCD Codepad ................................................................................................................21
Zone Indicators......................................................................................................................................................21
AWAY Indicator ...................................................................................................................................................21
STAY Indicator.....................................................................................................................................................21
System Disarmed...................................................................................................................................................22
MAINS Indicator...................................................................................................................................................22
Zone Isolating Mode..............................................................................................................................................22
FAULT Indicator...................................................................................................................................................22
Programming Mode...............................................................................................................................................22
Off Indicator/Zone Sealed......................................................................................................................................23
On Indicator/Zone In Alarm...................................................................................................................................23
Audible Indicators .................................................................................................................................................23
System Operations.............................................................................................................................24
Arming The System In AWAY Mode ......................................................................................................24
Disarming The System From AWAY Mode.............................................................................................25
Arming The System In STAY Mode ........................................................................................................25
Disarming The System From STAY Mode ..............................................................................................27
Codepad Functions...........................................................................................................................28
Isolating Zones .................................................................................................................................29
Standard Isolating..................................................................................................................................... 29
Code To Isolate .........................................................................................................................................30

Fault Analysis Mode......................................................................................................................... 31
Fault Descriptions..................................................................................................................................... 32
Low Battery...........................................................................................................................................................32
Date and Time........................................................................................................................................................32
Sensor Watch.........................................................................................................................................................32
Horn Speaker Monitor............................................................................................................................................32
Reserved................................................................................................................................................................32
E2Fault..................................................................................................................................................................32
Reserved................................................................................................................................................................32
Communication Failure..........................................................................................................................................32
AC Mains Failure...................................................................................................................................................32
Codepad Duress Alarm............................................................................................................................. 33
Codepad Panic Alarm - Versions Up To 1.26.......................................................................................... 33
Codepad Panic Alarm – Version 1.27 Onwards ...................................................................................... 33
Codepad Fire Alarm – Version 1.27 Onwards......................................................................................... 33
Codepad Medical Alarm – Version 1.27 Onwards .................................................................................. 33
Master Code Functions .................................................................................................................... 34
Arm Or Disarm Both Areas At The Same Time......................................................................................................34
Changing and Deleting User Codes.........................................................................................................................35
Changing Domestic Phone Numbers.......................................................................................................................37
Event Memory Recall Mode...................................................................................................................................39
Walk Test Mode.....................................................................................................................................................40
Fault Analysis Mode...............................................................................................................................................41
Setting The Date and Time.....................................................................................................................................42
Turning Day Alarm On and Off..............................................................................................................................42
Reset Latching Outputs ..........................................................................................................................................43
Initiate A Modem Call............................................................................................................................................43
User Code Functions – Partitioned Systems Only............................................................................ 44
Arm Or Disarm Both Areas At The Same Time......................................................................................................44
Hold Down Functions ............................................................................................................................... 45
Arm The System In AWAY Mode..........................................................................................................................45
Arm The System In STAY Mode............................................................................................................................45
Horn Speaker Test..................................................................................................................................................45
Bell Test ................................................................................................................................................................45
Strobe Test.............................................................................................................................................................46
Turning Day Alarm On and Off..............................................................................................................................46
Fault Analysis Mode...............................................................................................................................................47
Initiate A Modem Call............................................................................................................................................47
Reset Latching Outputs ..........................................................................................................................................47
Codepad ID and Beeper Tone Change ....................................................................................................................48
Initiate A Test Report.............................................................................................................................................48
Partitioning ...................................................................................................................................... 49
Operating Codepads When Partitioned............................................................................................ 51
Communication Options................................................................................................................... 52
Remote Arming Via The Telephone......................................................................................................... 53
Domestic Dialling Reporting..................................................................................................................... 54
Basic Pager Reporting .............................................................................................................................. 55
Optional Equipment......................................................................................................................... 56
Glossary Of Terms............................................................................................................................ 58

Warranty...........................................................................................................................................61
Limitations ............................................................................................................................................................62
Maintenance ..........................................................................................................................................................62
Specifications ........................................................................................................................................................63
Advice To Users....................................................................................................................................................64
New Zealand Telepermit Notes..............................................................................................................................64
Quality Policy........................................................................................................................................................65
Installation Notes..............................................................................................................................66
Service Notes.....................................................................................................................................69
Index.................................................................................................................................................70

8Solution 6+6 Operators Manual
ISSUE123.DOC Electronics Design and Manufacturing Pty Limited

Introduction Congratulations on selecting the Solution 6+6 control panel to protect you
and your property. So that you can obtain the most from your unit, we suggest
that you take the time to read through this manual and familiarise yourself with
the numerous outstanding operating features of this system.
You will notice that in all aspects of planning, engineering, styling, operation,
convenience and adaptability, we have sought to anticipate your every possible
requirement. Programming simplicity and speed have been some of the major
considerations and we believe that our objectives in this area have been more
than satisfied.
This manual will explain all aspects of operating the control panel. All system
parameters and options are detailed, however suitability is left up to the
individual. Every system can be tailored to meet all requirements quickly and
easily.
The Solution range of control panels are very popular with thousands of
people throughout many countries of the globe, all of whom have various
levels of technical aptitude and ability. We have tried to aim this manual at all
levels of readers.
As Solution control panels continue to be improved over the years, they have
become very powerful. Some of its early first-time users have advanced to true
"power users" and we need to address their needs too, while maintaining the
simplicity of the manual and the product.
This operators manual is intended for BOTH the Solution 6+6 Dialler
(CC600) and Solution 6+6 Local (LP600) panels. If you have a local
panel (LP600), disregard all references and features in this manual which
involve telephone dialling.
Solution 6+6 Operators Manual 9
Electronics Design and Manufacturing Pty Limited ISSUE123.DOC

Features The Solution 6+6 control panel uses the very latest in microprocessor
technology to provide you with more useful features and superior reliability
and performance.
Following is a list of the main features that the control panel will provide.
ØEight Programmable User Codes
ØSTAY Mode and AWAY Mode Operation
ØEntry and Exit Warning Beeper
ØSix Programmable Burglary Zones
ØSix 24 Hour Tamper Zones
ØPartitionable To 2 Areas
ØZone Lockout
ØSensor Watch
ØDay Alarm
ØDynamic Battery Testing
ØRemote Arming
ØAnswering Machine Bypass
ØAC Fail and System Fault Indicators
ØEvent Memory Recall
ØWalk Test Mode
ØUpload/Download Programmable
ØMonitored Siren Output
ØStrobe Output
ØRelay Output
ØEDMSAT – Satellite Siren Compatible
ØSeparate Fire Alarm Sound
One option that can be programmed by your installer will prevent another
installer or technician from performing any service to your system. This should
be discussed with your installer.
Refer to "Optional Equipment" on page 56 for more information on accessories
and other features that can be used with your system.
10 Solution 6+6 Operators Manual
ISSUE123.DOC Electronics Design and Manufacturing Pty Limited

Basic System Operation
The overall purpose of your alarm system is to deter any would be intruder
from entering your premises.
Before leaving your home or office, make sure all windows and doors are
closed. Enter your designated followed by the button. Your alarm
system will now arm in AWAY Mode and commence counting down the exit
time.
After the exit time has expired, you will hear one long beep at the remote
codepad to indicate that the system has been armed in AWAY Mode. Any
unsealed zones will be automatically isolated. The control panel is now ready
to activate the sirens and strobe lights should an alarm occur.
If a zone that is sealed has triggered after exit time has expired, a number of
events will occur. Following is a typical sequence of events.
1. The control panel will activate any audible devices such as sirens,
flashing blue strobe light and the communications dialler.
2. The communication dialler will transmit all relevant alarm information
via the telephone line alerting the respective persons of the current state
of events.
3. The siren timer will commence counting down as soon as an alarm
occurs. When the siren run time expires, the siren will automatically
reset and be placed into a ready state for the next alarm.
4. Upon your return, the blue strobe light may still be operating to inform
you that there has been an alarm.
5. One or a number of zone indicators will be flashing, allowing you to
identify the particular zone(s) that caused the alarm condition.
This is a very basic outline of the general system operation. As there are many
features available in the Solution 6+6 control panel, there could be
numerous variations from the above sequence.
Solution 6+6 Operators Manual 11
Electronics Design and Manufacturing Pty Limited ISSUE123.DOC

Code Retries Code retries restricts the amount of times an invalid user code can be used in
an attempt to operate the system. An alarm caused by this is known as a
"Codepad Tamper Alarm". When a codepad tamper alarm occurs, the system
will carry out the following events;
1. Activate the sirens and strobe connected to the control panel. Contact
your installer if you require this to be silent.
2. Shutdown all codepads that are connected and automatically disable them
from operating the system. Your installer programs the length of time
they are disabled for.
3. Send an "Access Denied" report to the base station receiver (Optional).
This function operates when the system is in the armed or disarmed state. Each
time the system is armed or disarmed, the code retry counter will be reset. The
number of incorrect code attempts can be anywhere between 1 to 15. This
value is programmed by your installer. Refer to the "Installation Notes" on
page 66 for the number of code retries set by your installer.
Codepad Lockout Time
The codepad will be locked out for the time programmed by your installer if
the wrong code has been entered more times than allowed by the code retry
attempts.
Codepad Extinguish Mode
This option when programmed by your installer will allow the indicators on
your codepad to automatically extinguish when the codepad is not used for a
period of sixty seconds.
The indicators will illuminate once a button has been pressed on the remote
codepad, when an alarm has occurred or when the systems entry time has been
activated. The indicators will not illuminate when a silent alarm has been
triggered. This option can only be programmed by your installer.
12 Solution 6+6 Operators Manual
ISSUE123.DOC Electronics Design and Manufacturing Pty Limited

Alarm Memory If you return to your premises and you notice the strobe light flashing, then
care should be taken as this indicates that there has been an alarm condition
while you were away.
When you enter the building and disarm the system, you will notice one or a
number of zone indicators flashing rapidly. This indicates that the zone(s) in
question have triggered into alarm.
If the zone indicator is flashing fast (On 0.25 sec/Off 0.25 sec), this indicates
that one of the 6 burglary zones has activated into alarm. If the zone indicator
is flashing fast (On 0.1 sec/Off 0.1 sec), then this indicates that one of the 6
tamper zones has activated into alarm. You should take note of this
information so that it can be passed onto your installer should they require it.
It is also possible to interrogate your alarm system using the event memory
recall function. This will allow you or your installer to interpret the exact
sequence of events that had occurred. Refer to "Event Memory Recall Mode"
on page 39 for more information.
Sensor Watch Time
Sensor watch is part of the control panel's watchdog circuitry. It is a feature
designed to ensure that all your detection devices are working correctly.
Sensor watch time determines how many days (0-99) a zone may remain sealed
before registering as a fault. This feature is only active while the system is in
the disarmed state because while your system is armed, the detection devices
are on stand-by waiting to be activated.
If a zone programmed for sensor watch has not triggered and reset during this
time, the FAULT indicator will illuminate and the codepad will beep once every
minute. To cancel the codepad beeping once every minute, press the
button. Refer to "Fault Descriptions" on page 32 for more information. Refer
to "Installation Notes" on page 66 for the sensor watch time set by your
installer.
Solution 6+6 Operators Manual 13
Electronics Design and Manufacturing Pty Limited ISSUE123.DOC

Day Alarm Day alarm may be used to monitor the front door of a shop or a pool gate. Day
alarm enables a combination of zones to be monitored while the system is in
the disarmed state. An indication is available via any of the programmable
outputs including the codepad buzzer. Only zones 1 - 4 may be used as day
alarm monitored zones. Refer to the "Installation Notes" on page 66 to check
which zones have been allocated to operate for day alarm.
Day Alarm Resetting
An output that has been programmed for day alarm resetting will operate when
a zone selected for day alarm is triggered. The output will reset when the zone
returns to normal. This can only occur when the system is disarmed.
Day Alarm Latching
An output that has been programmed for day alarm latching will operate when
a zone selected for day alarm is triggered. The output will reset when the
button has been pressed. This can only occur when the system is disarmed.
Example If you have multiple zones programmed for day alarm and one of them has
triggered, it is difficult to know which zone caused the alarm. Using the option
of day alarm latching will solve the problem. When a day alarm zone triggers,
all zone indicators are turned off leaving only the zone or zones that caused the
day alarm illuminated. To clear the day alarm memory, press the button.
Operation
Day alarm is turned on and off by holding the 4button down for two seconds
or alternatively, you may enter the followed by 7and the
button. Refer to "Hold Down Functions" on page 45 for more information.
Three beeps indicate that day alarm is turned on, two beeps indicate that day
alarm is turned off.
If a zone has been programmed for day alarm, it can be isolated in the normal
way. The isolated zone therefore will not register as a day alarm zone.
14 Solution 6+6 Operators Manual
ISSUE123.DOC Electronics Design and Manufacturing Pty Limited

Entry Time Entry time is the amount of time allowed to disarm your system after you have
opened the entry delay zone. During the entry time, the codepad buzzer will
beep twice per second warning you to disarm your system. An alarm will
activate if you do not disarm your system before the entry time expires. Refer
to the "Installation Notes" on page 66 for the entry time set by your installer.
Exit Time Exit time is the amount of time you have to leave your premises after you have
entered your code to arm the system. You will hear a long beep from the
codepad to indicate the end of exit time. Make sure you exit your premises
before this time expires. Refer to "Installation Notes" on page 66 for the
programmed exit time set by your installer.
System Date and Time
The control panel has a real time 12 month calendar and 24 hour clock that
needs to be set and changed for daylight savings. This will allow the system to
log events and send test reports with accurate time stamping if programmed.
Refer to "Master Code Functions" on page 34 for more information on setting
the date and time.
Solution 6+6 Operators Manual 15
Electronics Design and Manufacturing Pty Limited ISSUE123.DOC

User Codes The purpose of user codes is to arm and disarm the system as well as perform
other specific functions as described in the Master Code Functions on page 34.
User codes can be any length between one to four digits long. Each user code
can have a different priority level allocated to it. This controls the behaviour of
the code, allowing it to arm only or to arm and disarm etc.
There are a total of 8 user codes available that can be altered or deleted at any
time by a Master Code holder. Multiple Master Codes may be programmed.
Refer to “Changing and Deleting User Codes”on page 35 for more information
on adding, deleting or changing user codes.
The priority level for each user code can only be programmed or changed by the
installer.
User Code 32 will report to the monitoring company when any of the following
methods for arming and disarming are used.
1. Arm and disarm via remote radio control equipment connected to the
optional Radio Key/Keyswitch Interface or Night Arm Station.
2. Arm the system remotely over the telephone.
3. Single button arming in AWAY Mode or STAY Mode.
4. Single button disarming from STAY Mode.
16 Solution 6+6 Operators Manual
ISSUE123.DOC Electronics Design and Manufacturing Pty Limited

User Code Priority There are seven different priority levels that can be allocated to the user code.
Each priority level allows or restricts the functions that different user code
holders may perform.
If user code priority levels 4, 6 or 12 have been programmed to any of the
available 8 user codes, the method of standard isolating will no longer operate.
Only those user codes with the priority level of 4, 6 or 12 will be able to isolate
zones using the method code to isolate.
Priority Description
0Arm and Disarm
1Arm Only
2Patrolman Code
4Arm and Disarm + Code To Isolate
6Patrolman Code + Code To Isolate
8Arm and Disarm + Master Code Functions
12 Arm and Disarm + Master Code Functions + Code To Isolate
Table 1: User Code Priority Levels
Arm and Disarm
This priority level allows the user code holder to arm and disarm the system.
Arm Only
This priority level allows the user code holder to arm the system but not disarm
it.
Patrolman Code
This priority level allows the patrolman to disarm the system only after an
alarm has occurred. This will prevent unauthorised use of the code. A
patrolman code can always arm the system.
Arm and Disarm + Code To Isolate
This priority level allows the user code holder to arm and disarm the system.
Isolating of zones will only be allowed by using the method “Code To Isolate”
once this priority level has been set. Refer to Isolating Zones on page 29 for
more information.
Patrolman Code + Code To Isolate
This priority level allows the patrolman to disarm the system only after an
alarm has occurred. This will prevent unauthorised use of the code. A
patrolman code can always arm the system.
Isolating of zones will only be allowed by using the method “Code To Isolate”
once this priority level has been set. Refer to Isolating Zones on page 29 for
more information.
0
1
2
4
6
Solution 6+6 Operators Manual 17
Electronics Design and Manufacturing Pty Limited ISSUE123.DOC

Arm and Disarm + Master Code Functions
This priority level allows arming and disarming of the system and the ability to
carry out any of the Master Code Functions described on page 34. More than
one user code can be allocated to this priority level.
Arm and Disarm + Master Code Functions + Code To Isolate
This priority level allows arming and disarming of the system and the ability to
carry out any of the Master Code Functions described on page 34.
Isolating zones will only be allowed by using the method "Code To Isolate"
once this priority level has been set. Refer to Isolating Zones on page 29 for
more information. More than one user code can be allocated to this priority
level.
8
12
18 Solution 6+6 Operators Manual
ISSUE123.DOC Electronics Design and Manufacturing Pty Limited

System Indicators and Operations
CP5 Eight Zone Codepad The codepad is the communications interface between you and
your alarm system. It allows you to issue commands and offers
both visual and audible indications that guide you through the
general operation.
The codepad incorporates numerous indicators. There are
ZONE indicators which are used to show the condition of each
zone and four others for general status. The following is a list
of situations and the relevant indications that will be seen.
Figure 1: CP5 Eight Zone Codepad
Zone Indicators The ZONE indicators are used to show the status of the zones. The following
table lists the various circumstances that the indicators will display (ie. Zone
Sealed, Zone Unsealed).
Indicator Definition
On Zone Is Unsealed
Off Zone Is Sealed
Flashing Very Fast
(0.1 Sec On – 0.1 Sec Off) 24 Hour Tamper Zone In Alarm Condition
Flashing Fast
(0.25 Sec On – 0.25 Sec Off) Zone Is In Alarm Condition
Flashing Slow
(1 Sec On – 1 Sec Off) Zone Is Manually Isolated
Flashing Very Slow
(2 Sec On – 1 Sec Off) 24 Hour Tamper Zone In The Unsealed State
Table 2: Zone Indicators
AWAY Indicator The AWAY indicator is used to indicate that the system is armed in the AWAY
Mode.
Indicator Definition
On System Is Armed In AWAY Mode
Off System Is Not Armed In AWAY Mode
Table 3: AWAY Indicator
STAY Indicator The STAY indicator is used to indicate that the system is armed in the STAY
Mode.
Indicator Definition
On System Is Armed In STAY Mode
Off System Is Not Armed In STAY Mode
Flashing System Is In Isolating Mode
Table 4: STAY Indicator
Solution 6+6 Operators Manual 19
Electronics Design and Manufacturing Pty Limited ISSUE123.DOC

MAINSIndicator The MAINS indicator is used to indicate that the systems AC mains supply is
normal or has failed.
Indicator Definition
On AC Mains Power Normal
Flashing AC Mains Failure
Table 5: MAINS Indicator
FAULT Indicator The FAULT indicator is used to indicate that the system has detected a system
fault. Refer to "Fault Analysis Mode" on page 31 for more information on
system faults.
Indicator Definition
On There Is A Fault That Needs To Be Rectified
Off The System Is Normal, There Are No Faults
Flashing There Is A Fault Waiting To Be Acknowledged
Table 6: FAULT Indicator
Audible Indicators In general, the audible indications given out by the codepad are as follows:
Indicator Definition
One Short Beep A Button Has Been Pressed On The Codepad Or
End Of Exit Time When Armed In STAY Mode
Two Short Beeps The System Has Accepted Your Code
Three Short Beeps The Requested Function Has Been Executed
One Long Beep Indicates End Of Exit Time For AWAY Mode Or
The Requested Operation Has Been Denied Or
Aborted
One Short Beep Every
Second Walk Test Mode Is Active
One Short Beep Every
Minute There Is A Fault Waiting To Be Acknowledged
Table 7: Audible Indications
20 Solution 6+6 Operators Manual
ISSUE123.DOC Electronics Design and Manufacturing Pty Limited
Other manuals for Solution 6+6 Wireless-AE
1
Table of contents
Other EDM Control Panel manuals
Popular Control Panel manuals by other brands

Twin-Star International
Twin-Star International DFS-220 quick guide

turck
turck TX710HB-P3CV01 quick start guide

Mircom
Mircom FA-300 Series Installation and operation manual

Vortice
Vortice TNF Instruction booklet

Exodraft
Exodraft EBC30 Installation and operation manual

WIKA
WIKA A2G-200 Operating instruction