4.) Setting the date & time
Lower the cover on the front of the unit. Move the
selector switch to the CLOCK SET position.
Press the or buttons to select the day.
Press the or buttons to select the month.
Press the or buttons to select the year.
Press the or buttons to select the hour.
Press the or buttons to select the minute.
Press the or buttons to select 5/2D, 7D or 24H
The date, time and function are now set. Move the selector switch
to the RUN position to run the program, or to the PROG SET position
to change the program setting.
1.) Factory default settings
Program: 5/2D
Backlight: On
Keypad: Unlocked
Frost Protection: O
Automatic Winter / Summer change over
24H
P1 ON P1 OFF P2 ON P2 OFF P3 ON P3 OFF
6:30 8:30 12:00 12:00 16:30 22:30
7D
P1 ON P1 OFF P2 ON P2 OFF P3 ON P3 OFF
6:30 8:30 12:00 12:00 16:30 22:30
All
7 days
5/2D
P1 ON P1 OFF P2 ON P2 OFF P3 ON P3 OFF
6:30 8:30 12:00 12:00 16:30 22:30
7:30 10:00 12:00 12:00 17:00 23:00
Mon-Fri
Sat-Sun 7.) Reviewing the program settings
Lower the cover on the front of the unit.
Move the selector switch to the PROG SET position.
By pressing this will review each of the ON/OFF times for P1 to P3.
When completed, move the selector switch to the RUN position.
8.) Boost function
This function allows the user to extend the ON period for 1, 2 or 3 hours.
If the zone that you wish to Boost is timed to be OFF, you have the
facility to switch it ON for 1, 2 or 3 hours.
Press once, twice or three times respectively.
To cancel the boost function, simply press the button again.
9.) Holiday mode
Lower the cover on the front of the unit.
Move the selector switch to the RUN position.
Press the button.
Press the or buttons to adjust the holiday period required. Press
The programmer is now switched OFF for the selected number of days.
By pressing again, this will cancel the holiday mode, thereby returning
the programmer to the normal settings.
6.) Adjusting the program settings
Lower the cover on the front of the unit.
Move the selector switch to the PROG SET position.
You can now program zone 1.
Press the or buttons to adjust the P1 ON time.
Press the or buttons to adjust the P1 OFF time.
Repeat this process to adjust the ON & OFF times for P2 & P3.
When completed, move the selector switch to the RUN position.
Every
day
2.) Factory program settings
3.) Resetting the timeswitch
It is necessary to press the RESET button prior to initial programming.
This button is located behind the cover on the front of the unit.
Contents
1.) Factory default settings
2.) Factory program settings
3.) Resetting the timeswitch
4.) Setting the date and time
5.) ON/OFF period selection
6.) Adjusting the program settings
7.) Reviewing the program settings
8.) Boost function
9.) Holiday mode
10.) Backlight mode selection
11.) Keypad lock and unlock
12.) Frost protection
13.) Copy function
14.) Master reset
Caution!
Before commencing, disconnect the
device from the mains. There are parts
that carry mains voltage behind the cover.
Never leave unsupervised when it is open.
(Prevent non specialists and especially
children from gaining access to it.)
This 1 zone timeswitch is designed to provide ON/OFF control for 1 zone, with the value added application of in built frost protection.
Never remove this product from the
electrical baseplate.
Disconnect from mains supply in the
event of any damage to any buttons.
Do not use sharp tools to push any
button.
Important: Keep this document
Press
Press
Press
Press
Press
Press
Press
Press
ZONE 1 SELECT
Zone
1
Boost Zone
1
Boost
5.) ON/OFF period selection
There are 4 modes available on this programmer for users to choose for their
individual application.
- The timeswitch operates 3 - ON/OFF periods per day.
ALL DAY - The timeswitch operates 1- ON/OFF period per day.
This operates from the rst ON time to the third OFF time.
ON - The timeswitch is permanently on. **ON**
OFF - The timeswitch is permanently o. **OFF**
Lower the cover on the front of the unit. By pressing the
button, you can change between AUTO - ALL DAY - ON - OFF for Zone 1.
AUTO
ok
ok
ok
ok
ok
+
-
+
-
+
-
+
-
+
-
+
-
+
-
ok
ok
ok
+
-
ok
ok
+
-
ok
10.) Backlight mode selection
There are two settings for selection. The factory default setting is ON.
ON - The backlight is permanently ON.
AUTO - On pressing any button the backlight stays on for 10 seconds.
To adjust the backlight setting, lower the cover on the front of the unit.
Move the selector switch to the RUN position.
Press the button for 5 seconds.
Press either the or buttons to select the ON or AUTO mode. Press
ok
+
-
ok
On
The Electric Heating Company Ltd. Unit 40, Block 5, Third Road, Blantyre Industrial Estate, Blantyre, Glasgow G72 0UP
Tel: 01698 820533 - Fax: 01698 825674 - Mail: info@electric-heatingcompany.co.uk - Web: www.electric-heatingcompany.co.uk
041216_AW1007_EC10001-OpIns_JW_RevA
EC10001 - 1 Zone Timeswitch
Operating Instructions Page 1 of 2
11.) Keypad lock and unlock
To lock the keypad, press and hold the and buttons for 5 seconds.
will appear on the screen. The keypad is now locked.
To unlock the keypad, press and hold the and buttons for 5 seconds.
will disappear from the screen. The keypad is now unlocked.
Holiday
14.) Master reset
Lower the cover on the front of the timeswitch.
There are four hinges holding the cover in place.
Between the 3rd and 4th hinges there is a circular hole.
Insert a ball point pen or similar object to master reset the timeswitch.
After pressing the master reset button, the date and time will now need to be
reprogrammed.
ok
ok Holiday
12.) Frost protection function
Selectable range 5~20°C
This function is set to protect pipes against freezing or
to prevent low room temperature when the timeswitch
is programmed to be OFF or is manually OFF.
Frost protection can be activated by following the procedure below.
Move the selector switch to the RUN position.
Press both the and buttons for 5 seconds, to enter selection mode.
Press either the or buttons to to turn On or turn O frost protection
Press button to conrm
Press either the or buttons to increase or decrease the desired
frost protection setpoint.
Press to select.
Zone 1 will be switched ON in the event of room temperature falling below
the frost protection setpoint.
+
-
+
-
ok
+
-
ok
Unlocked
O
The Electric Heating Company Ltd. Unit 40, Block 5, Third Road, Blantyre Industrial Estate, Blantyre, Glasgow G72 0UP
Tel: 01698 820533 - Fax: 01698 825674 - Mail: info@electric-heatingcompany.co.uk - Web: www.electric-heatingcompany.co.uk
Copy function may only be used if the timeswitch is in the 7D mode.
Lower the cover on the front of the timeswitch.
Move the selector switch to the PROG SET position.
First, program one of the days of the week with a schedule you wish to copy to
other days.
While still on that day press and hold the button.
This will take you into the Copy screen.
The day of the week that is to be copied is shown and the day it is to be copied
to is ashing.
Press the button to copy the schedule to this day.
Press the button to skip this day
Continue in this fashion by pressing the button to copy the schedule to the
day ashing and by pressing the button to skip that day.
When you are nished press the button and the timeswitch will return to the
standard schedule programming screen.
13.) Copy function
-
+
Copy
+
-
ok
EC10001 - 1 Zone Timeswitch
Operating Instructions Page 2 of 2
Pre-set Clock
3 On / O Periods
Lockable Keypad
1,2,3, Hour Boost
Frost Protection
Blue Backlight Display
Auto Winter / Summer Time
24Hour - 5/2 Day - 7 Day
Features:
041216_AW1007_EC10001-InsIns_JW_RevA
EC10001 - 1 Zone Timeswitch
Installation Instructions Page 1 of 2
1
2
3 4
56
Type
EN60730
1C IP20
EN60529
50
°C
0
122
°F
32
5-95%RH
Before commencing any work on the electrical connections, you must rst disconnect the device from the mains.
None of the 230V connections must be live until the installation has been completed and the housing is closed.
Only qualied electricians or authorised service sta are permitted to open the terminal box.
Caution! There are parts that carry mains voltage behind the cover. The terminal box must not be left
unsupervised when open. (Prevent non specialists and especially children from gaining access to it.)
For use in normal environments.
If the device is used in a way not specied by the manufacturer, its safety may be impaired.
This timeswitch can be mounted in the following ways:
1. Directly wall mounted
2. Mounted to a recessed conduit box
Installation and connection should only be carried out by a qualied person and in accordance with national wiring regulations.
160.5
100
The Electric Heating Company Ltd. Unit 40, Block 5, Third Road, Blantyre Industrial Estate, Blantyre, Glasgow G72 0UP
Tel: 01698 820533 - Fax: 01698 825674 - Mail: info@electric-heatingcompany.co.uk - Web: www.electric-heatingcompany.co.uk
EC10001 - 1 Zone Timeswitch
Installation Instructions Page 2 of 2
Contents
1.) Factory default settings
2.) Specications & wiring
3.) Master reset
Caution!
Before commencing, disconnect the
device from the mains. There are parts
that carry mains voltage behind the cover.
Never leave unsupervised when it is open.
(Prevent non specialists and especially
children from gaining access to it.)
This 1 zone timeswitch is designed to provide ON/OFF control for 1 zone, with the value added application of in built frost protection.
Never remove this product from the
electrical baseplate.
Disconnect from mains supply in the
event of any damage to any buttons.
Do not use sharp tools to push any
button.
Important: Keep this document
Prior to setting the timeswitch, it is
neccessary to complete all required
settings described in this section.
1.) Factory default settings
Contacts: Volt free contact
Program: 5/2D
Backlight: On
Keypad: Unlocked
Frost Protection: O
Clock type: 24 Hr Clock
Automatic Winter / Summer change over
Power Supply: 230 Vac
Ambient Temp: 0~35°C
Contact Rating: 250 Vac 3A(1A)
Program Memory backup: 1 year
Battery: 3Vdc Lithium LIR 2032
2.) Specications & wiring
Backlight: Blue
IP rating: IP20.
Backplate: British System Standard
Pollution degree 2: Resistance to
voltage surge 2000V; as per EN 60730
Automatic Action: Type 1.S
Software: Class A
L
N1
4
24
3
200-240Vac
50Hz-60Hz
CONTACT RATING: 250Vac~/3(1)A
OFF ON
If mains voltage output is required, terminals L & 1 must be electrically
linked. The cable link is provided with this programmer.
Lower the cover on the front of the programmer.
There are four hinges holding the cover in place.
Between the 3rd and 4th hinges there is a circular hole.
Insert a ball point pen or similar object to master reset the programmer.
After pressing the master reset button, the date and time will now need
to be reprogrammed.
3.) Master reset
The Electric Heating Company Ltd. Unit 40, Block 5, Third Road, Blantyre Industrial Estate, Blantyre, Glasgow G72 0UP
Tel: 01698 820533 - Fax: 01698 825674 - Mail: info@electric-heatingcompany.co.uk - Web: www.electric-heatingcompany.co.uk
Pre-set Clock
3 On / O Periods
Lockable Keypad
1,2,3, Hour Boost
Frost Protection
Blue Backlight Display
Auto Winter / Summer Time
24Hour - 5/2 Day - 7 Day
Features:

Popular Timer manuals by other brands

JARDIBRIC AQUA FLOW PNR11 instructions

JARDIBRIC

JARDIBRIC AQUA FLOW PNR11 instructions

Lencore LP-2 Installation & programming manual

Lencore

Lencore LP-2 Installation & programming manual

Amperes PT1800 instruction manual

Amperes

Amperes PT1800 instruction manual

Dewenwils HOYS16A1 instruction manual

Dewenwils

Dewenwils HOYS16A1 instruction manual

Utilitech TH06WHBL Instruction manual and warranty

Utilitech

Utilitech TH06WHBL Instruction manual and warranty

Switched on Products UK113 Installation & programming manual

Switched on Products

Switched on Products UK113 Installation & programming manual

TimerGPS PLUS2 quick guide

TimerGPS

TimerGPS PLUS2 quick guide

Powerwerx ITS-12 user manual

Powerwerx

Powerwerx ITS-12 user manual

Woods 50126 manual

Woods

Woods 50126 manual

TRU Components 2144022 operating instructions

TRU Components

TRU Components 2144022 operating instructions

REX MicroRex S11 quick start guide

REX

REX MicroRex S11 quick start guide

Intermatic E1010 Installation and operating

Intermatic

Intermatic E1010 Installation and operating

ETI SHT-1 instructions

ETI

ETI SHT-1 instructions

Steren TEMP­24H/MINI instruction manual

Steren

Steren TEMP­24H/MINI instruction manual

Inkel IPT-8254 Operation manual

Inkel

Inkel IPT-8254 Operation manual

Stanley TIMERMAX WEEKLY TWIN quick start guide

Stanley

Stanley TIMERMAX WEEKLY TWIN quick start guide

Clever Little Box TU-8A Programming guide

Clever Little Box

Clever Little Box TU-8A Programming guide

Rain Bird 1ZEHTMR instructions

Rain Bird

Rain Bird 1ZEHTMR instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.